Joel L. Dawson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joel L. Dawson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ali Hadiashar
BitWave Semiconductor, Inc., 900 Chelmsford St., Tower 3, Floor 7, Lowell, MA 01851
1 shared publication - Hongshen Ma
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, 02139, USA
1 shared publication - Michael Scharfstein
Vecna Technologies, Inc. Cambridge, MA 02140, USA
1 shared publication - Olumuyiwa T. Ogunnika
Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
1 shared publication - Roshni C. Cooper
Microsystems Technology Laboratory, Massachusetts Institute of Technology, Cambridge, 02139 USA
1 shared publication - Seward B. Rutkove
Department of Neurology, Beth Israel Deaconess Medical Center Harvard Medical School Boston Massachusetts USA
1 shared publication
Latest Publications
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 3566-3569
A handheld Electrical Impedance Myography probe for the assessment of neuromuscular disease
Electrical Impedance Myography (EIM) is a non-invasive, painless clinical technique for the diagnosis and monitoring of a variety of neuromuscular diseases including amyotrophic lateral sclerosis and focal nerve injuries. It involves the application of a low-intensity alternating current to a muscle group and the measurement of the consequent surface voltage patterns. This paper presents a system for the rapid and accurate acquisition of data employing an interrogating signal composed of multiple tones with frequencies between 10 kHz and 4 MHz. The use of this composite signal makes possible measurement of impedance at multiple frequencies simultaneously. In addition, this system takes impedance measurements at multiple orientations with respect to the muscle fibers by means of an electronically reconfigurable electrode array and utilizes the linearity of muscle tissue to reduce the required measurement time. Testing of the EIM system on beef has established the capability of this system to rapidly detect the anisotropic conductive properties of muscle tissue at multiple frequencies.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 3566-3569
A handheld Electrical Impedance Myography probe for the assessment of neuromuscular disease
Electrical Impedance Myography (EIM) is a non-invasive, painless clinical technique for the diagnosis and monitoring of a variety of neuromuscular diseases including amyotrophic lateral sclerosis and focal nerve injuries. It involves the application of a low-intensity alternating current to a muscle group and the measurement of the consequent surface voltage patterns. This paper presents a system for the rapid and accurate acquisition of data employing an interrogating signal composed of multiple tones with frequencies between 10 kHz and 4 MHz. The use of this composite signal makes possible measurement of impedance at multiple frequencies simultaneously. In addition, this system takes impedance measurements at multiple orientations with respect to the muscle fibers by means of an electronically reconfigurable electrode array and utilizes the linearity of muscle tissue to reduce the required measurement time. Testing of the EIM system on beef has established the capability of this system to rapidly detect the anisotropic conductive properties of muscle tissue at multiple frequencies.
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19308833,p. 364-367
A Chopper Stabilized CMOS Analog Multiplier with Ultra Low DC Offsets
As with many analog building blocks, DC offsets limit the accuracy of analog multipliers. Chopper stabilization, long applied to precision amplifiers, has been recently modified to be applicable to analog multiplication (Dawson and Lee, 2003). In this paper we present a general approach to chopper stabilization for analog multiplication. An IC fabricated in National Semiconductor's 0.18mum process allowed us to characterize an array of the new multipliers, which represents the first thorough experimental characterization of the new technique. The prototype circuits exhibit an average output offset of 204muV, with a standard deviation of 23muV, while consuming 181muW of power each. These are the lowest reported measured offsets in the DC analog multiplier literature
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19308833,p. 364-367
A Chopper Stabilized CMOS Analog Multiplier with Ultra Low DC Offsets
As with many analog building blocks, DC offsets limit the accuracy of analog multipliers. Chopper stabilization, long applied to precision amplifiers, has been recently modified to be applicable to analog multiplication (Dawson and Lee, 2003). In this paper we present a general approach to chopper stabilization for analog multiplication. An IC fabricated in National Semiconductor's 0.18mum process allowed us to characterize an array of the new multipliers, which represents the first thorough experimental characterization of the new technique. The prototype circuits exhibit an average output offset of 204muV, with a standard deviation of 23muV, while consuming 181muW of power each. These are the lowest reported measured offsets in the DC analog multiplier literature