OOOlumuyiwa T. Ogunnika

Olumuyiwa T. Ogunnika

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olumuyiwa T. Ogunnika has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Seward B. Rutkove

    Department of Neurology, Beth Israel Deaconess Medical Center Harvard Medical School Boston Massachusetts USA

    2 shared publications
  • H. Ma

    †Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA

    1 shared publication
  • Hongshen Ma

    Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, 02139, USA

    1 shared publication
  • J. L. Dawson

    †Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA

    1 shared publication
  • Joel L. Dawson

    Microsystems Technology Laboratory, Massachusetts Institute of Technology, Cambridge, 02139 USA

    1 shared publication
  • M. Scharfstein

    †Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA

    1 shared publication

Latest Publications

  • A portable system for the assessment of neuromuscular diseases with electrical impedance myography

    by O. T. Ogunnika, S. B. Rutkove, H. Ma, P. M. Fogerson, M. Scharfstein, R. C. Cooper, J. L. Dawson

    Primary objective: To create a system for the acquisition of multi-angle, multifrequency muscle impedance data. Research design: Device development and preliminary testing. Methods and procedures: The system presented here employs an interrogating signal composed of multiple tones with frequencies between 10 kHz and 300 kHz. The use of a composite signal makes possible measurement of impedance at multiple frequencies simultaneously. In addition, this system takes impedance measurements at multiple orientations with respect to the muscle fibres by means of an electronically reconfigurable electrode array. The required measurement time is reduced by taking advantage of muscle's linearity with respect to the flow of electrical current. Main outcomes and results: The system was tested in normal subjects, a patient with amyotrophic lateral sclerosis, and one with inclusion body myositis; unique impedance signatures were identified the two patients. Conclusions: Early data suggest that this system is capable of high-quality data collection and may detect changes in neuromuscular disease; study of additional normal subjects and patients with a variety of neuromuscular diseases is warranted.


  • A handheld Electrical Impedance Myography probe for the assessment of neuromuscular disease

    by Olumuyiwa T. Ogunnika, Michael Scharfstein, Roshni C. Cooper, Hongshen Ma, Joel L. Dawson, Seward B. Rutkove

    Electrical Impedance Myography (EIM) is a non-invasive, painless clinical technique for the diagnosis and monitoring of a variety of neuromuscular diseases including amyotrophic lateral sclerosis and focal nerve injuries. It involves the application of a low-intensity alternating current to a muscle group and the measurement of the consequent surface voltage patterns. This paper presents a system for the rapid and accurate acquisition of data employing an interrogating signal composed of multiple tones with frequencies between 10 kHz and 4 MHz. The use of this composite signal makes possible measurement of impedance at multiple frequencies simultaneously. In addition, this system takes impedance measurements at multiple orientations with respect to the muscle fibers by means of an electronically reconfigurable electrode array and utilizes the linearity of muscle tissue to reduce the required measurement time. Testing of the EIM system on beef has established the capability of this system to rapidly detect the anisotropic conductive properties of muscle tissue at multiple frequencies.