APAndrea Paolino

Andrea Paolino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrea Paolino has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hydrophilic and lipophilic radiopharmaceuticals as tracers in pharmaceutical development: In vitro – In vivo studies

    by Mariella Terán, Eduardo Savio, Andrea Paolino, Malcolm Frier

    Scintigraphic studies have been performed to assess the release, both in vitro and in vivo, of radiotracers from tablet formulations. Four different tracers with differing physicochemical characteristics have been evaluated to assess their suitability as models for drug delivery. In-vitro disintegration and dissolution studies have been performed at pH 1, 4 and 7. In-vivo studies have been performed by scintigraphic imaging in healthy volunteers. Two hydrophilic tracers, (99mTc-DTPA) and (99mTc-MDP), and two lipophilic tracers, (99mTc-ECD) and (99mTc-MIBI), were used as drug models. Dissolution and disintegration profiles, differed depending on the drug model chosen. In vitro dissolution velocity constants indicated a probable retention of the radiotracer in the formulation. In vivo disintegration velocity constants showed important variability for each radiopharmaceutical. Pearson statistical test showed no correlation between in vitro drug release, and in vivo behaviour, for 99mTc-DTPA, 99mTc-ECD and 99mTc-MIBI. High correlation coefficients were found for 99mTc-MDP not only for in vitro dissolution and disintegration studies but also for in vivo scintigraphic studies. Scintigraphic studies have made a significant contribution to the development of drug delivery systems. It is essential, however, to choose the appropriate radiotracers as models of drug behaviour. This study has demonstrated significant differences in release patterns, depending on the model chosen. It is likely that each formulation would require the development of a specific model, rather than being able to use a generic drug model on the basis of its physicochemical characteristics.


  • Open Access

    188Re radiopharmaceuticals for radiosynovectomy: evaluation and comparison of tin colloid, hydroxyapatite and tin-ferric hydroxide macroaggregates

    by Eduardo Savio, María Cristina Ures, Patricia Zeledón, Victoria Trindade, Andrea Paolino, Virginia Mockford, Antonio Malanga, Marcelo Fernández, Javier Gaudiano


  • Open Access

    Physico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy

    by Ma Cristina Ures, Eduardo Savio, Antonio Malanga, Marcelo Fernández, Andrea Paolino, Javier Gaudiano

    Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium (188Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans.