Andrea Paolino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrea Paolino has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Savio
Cátedra de Radioquímica. Facultad de Química. Universidad de la República. Montevideo, Uruguay
3 shared publications - Antonio Malanga
Cátedra de Farmacotecnia. Facultad de Química. Universidad de la República. Montevideo, Uruguay
2 shared publications - Javier Gaudiano
Centro de Medicina Nuclear. Hospital de Clínicas. Facultad de Medicina. Universidad de la República. Montevideo, Uruguay
2 shared publications - María Cristina Ures
Cátedra de Radioquímica. Facultad de Química. Universidad de la República. Montevideo, Uruguay
2 shared publications - Malcolm Frier
Radiopharmacy Unit. Queen's Medical Centre, Nottingham University. Nottingham, UK
1 shared publication - Marcelo Fernández
Cátedra de Radioquímica. Facultad de Química. Universidad de la República. Montevideo, Uruguay
1 shared publication
Latest Publications
- Open Access
- 18 October 2005
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 5 (1) , 5
Hydrophilic and lipophilic radiopharmaceuticals as tracers in pharmaceutical development: In vitro – In vivo studies
Scintigraphic studies have been performed to assess the release, both in vitro and in vivo, of radiotracers from tablet formulations. Four different tracers with differing physicochemical characteristics have been evaluated to assess their suitability as models for drug delivery. In-vitro disintegration and dissolution studies have been performed at pH 1, 4 and 7. In-vivo studies have been performed by scintigraphic imaging in healthy volunteers. Two hydrophilic tracers, (99mTc-DTPA) and (99mTc-MDP), and two lipophilic tracers, (99mTc-ECD) and (99mTc-MIBI), were used as drug models. Dissolution and disintegration profiles, differed depending on the drug model chosen. In vitro dissolution velocity constants indicated a probable retention of the radiotracer in the formulation. In vivo disintegration velocity constants showed important variability for each radiopharmaceutical. Pearson statistical test showed no correlation between in vitro drug release, and in vivo behaviour, for 99mTc-DTPA, 99mTc-ECD and 99mTc-MIBI. High correlation coefficients were found for 99mTc-MDP not only for in vitro dissolution and disintegration studies but also for in vivo scintigraphic studies. Scintigraphic studies have made a significant contribution to the development of drug delivery systems. It is essential, however, to choose the appropriate radiotracers as models of drug behaviour. This study has demonstrated significant differences in release patterns, depending on the model chosen. It is likely that each formulation would require the development of a specific model, rather than being able to use a generic drug model on the basis of its physicochemical characteristics.
- 18 October 2005
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 5 (1) , 5
Open AccessHydrophilic and lipophilic radiopharmaceuticals as tracers in pharmaceutical development: In vitro – In vivo studies
Scintigraphic studies have been performed to assess the release, both in vitro and in vivo, of radiotracers from tablet formulations. Four different tracers with differing physicochemical characteristics have been evaluated to assess their suitability as models for drug delivery. In-vitro disintegration and dissolution studies have been performed at pH 1, 4 and 7. In-vivo studies have been performed by scintigraphic imaging in healthy volunteers. Two hydrophilic tracers, (99mTc-DTPA) and (99mTc-MDP), and two lipophilic tracers, (99mTc-ECD) and (99mTc-MIBI), were used as drug models. Dissolution and disintegration profiles, differed depending on the drug model chosen. In vitro dissolution velocity constants indicated a probable retention of the radiotracer in the formulation. In vivo disintegration velocity constants showed important variability for each radiopharmaceutical. Pearson statistical test showed no correlation between in vitro drug release, and in vivo behaviour, for 99mTc-DTPA, 99mTc-ECD and 99mTc-MIBI. High correlation coefficients were found for 99mTc-MDP not only for in vitro dissolution and disintegration studies but also for in vivo scintigraphic studies. Scintigraphic studies have made a significant contribution to the development of drug delivery systems. It is essential, however, to choose the appropriate radiotracers as models of drug behaviour. This study has demonstrated significant differences in release patterns, depending on the model chosen. It is likely that each formulation would require the development of a specific model, rather than being able to use a generic drug model on the basis of its physicochemical characteristics.
- Open Access
- 30 January 2004
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 4 (1) , 1
188Re radiopharmaceuticals for radiosynovectomy: evaluation and comparison of tin colloid, hydroxyapatite and tin-ferric hydroxide macroaggregates
- 30 January 2004
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 4 (1) , 1
Open Access188Re radiopharmaceuticals for radiosynovectomy: evaluation and comparison of tin colloid, hydroxyapatite and tin-ferric hydroxide macroaggregates
- Open Access
- 14 October 2002
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 2 (1) , 1
Physico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy
Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium (188Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans.
- 14 October 2002
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 2 (1) , 1
Open AccessPhysico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy
Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium (188Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans.