María Cristina Ures
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
María Cristina Ures has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Paolino
Cátedra de Radioquímica. Facultad de Química. Universidad de la República. Montevideo, Uruguay
2 shared publications - Antonio Malanga
Cátedra de Farmacotecnia. Facultad de Química. Universidad de la República. Montevideo, Uruguay
2 shared publications - Eduardo Savio
Cátedra de Radioquímica. Facultad de Química. Universidad de la República. Montevideo, Uruguay
2 shared publications - Javier Gaudiano
Centro de Medicina Nuclear. Hospital de Clínicas. Facultad de Medicina. Universidad de la República. Montevideo, Uruguay
2 shared publications - Marcelo Fernández
Cátedra de Radioquímica. Facultad de Química. Universidad de la República. Montevideo, Uruguay
1 shared publication - Marcelo Fernández
Cátedra de Inmunología. Facultad de Química. Universidad de la República. Montevideo, Uruguay
1 shared publication
Latest Publications
- Open Access
- 30 January 2004
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 4 (1) , 1
188Re radiopharmaceuticals for radiosynovectomy: evaluation and comparison of tin colloid, hydroxyapatite and tin-ferric hydroxide macroaggregates
- 30 January 2004
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 4 (1) , 1
Open Access188Re radiopharmaceuticals for radiosynovectomy: evaluation and comparison of tin colloid, hydroxyapatite and tin-ferric hydroxide macroaggregates
- Open Access
- 14 October 2002
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 2 (1) , 1
Physico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy
Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium (188Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans.
- 14 October 2002
- Published by Springer Nature in BMC Nuclear Medicine
- Vol. 2 (1) , 1
Open AccessPhysico-chemical characterisation and biological evaluation of 188-Rhenium colloids for radiosynovectomy
Radiosynovectomy is a type of radiotherapy used to relieve pain and inflammation from rheumatoid arthritis. In this study, 188-Rhenium (188Re) colloids were characterized by physical and biological methodologies. This was used to assess which parameters of the kit formulation would be the basis in the development of a more effective radiopharmaceutical for synovectomy. Intraarticular injection in knees of rabbits assessed cavity leakage of activity. The physical characteristics of tin (Sn) and sulphur (S) colloids were determined to assess the formulation with suitable properties. Particles were grouped in three ranges for analyzing their distribution according to their number, volume and surface. The ideal particle size range was considered to be from 2 to 10 microns. Membrane filtration and laser diffraction characterization methodologies were used. While membrane filtration could give misleading data, laser diffraction proportions more reliable results. The Sn colloid showed a better distribution of particle volume and surface than S colloid, in the 2 to 10 microns range. The 188Re-Sn colloid was obtained with a radiochemical purity higher than 95% after 30 minutes of autoclaving. While Sn colloid kit stability was verified for 60 days, the 188Re-Sn preparation was stable in the first 24 hrs. No significant intrabatch variability (n = 3) was detected. Biodistribution and scintigraphic studies in rabbits after intraarticular injection showed relevant activity only in knee, being 90% at 48 hours. The 188Re-Sn colloid is easy to prepare, is stable for 24 hours and shows minimal cavity leakage after intraarticular injection into rabbit knees, suggesting this radiotherapeutical agent has suitable physical properties for evaluation for joint treatment in humans.