AKAndrew Karellas

Andrew Karellas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew Karellas has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Sankararaman Suryanarayanan

    Department of Radiology and Winship Cancer Institute, Emory University School of Medicine, 1701 Uppergate Drive, Suite 5018, Atlanta, Georgia 30322

    6 shared publications
  • Srinivasan Vedantham

    University of Arizona, Department of Biomedical Engineering, Tucson, Arizona, United States

    6 shared publications
  • Ioannis Sechopoulos

    Department of Radiology and Winship Cancer Institute, Emory University School of Medicine, 1701 Uppergate Drive, Suite 5018, Atlanta, Georgia 30322, USA

    2 shared publications
  • Carl D'ORsi

    Emory University School of Medicine, Department of Radiology and Winship Cancer Institute, 1701 Uppergate Drive, Suite 5018, Atlanta, Georgia 30322

    1 shared publication
  • Carl J. D'ORsi

    Department of Radiology and Winship Cancer Institute, Emory University School of Medicine, 1701 Uppergate Drive, Suite 5018, Atlanta, Georgia 30322

    1 shared publication
  • Carl J. D’oRsi

    Emory University School of Medicine

    1 shared publication

Latest Publications

  • Scatter radiation in digital tomosynthesis of the breast

    by Ioannis Sechopoulos, Sankararaman Suryanarayanan, Srinivasan Vedantham, Carl J. D'ORsi, Andrew Karellas

    Digital tomosynthesis of the breast is being investigated as one possible solution to the problem of tissue superposition present in planar mammography. This imaging technique presents various advantages that would make it a feasible replacement for planar mammography, among them similar, if not lower, radiation glandular dose to the breast; implementation on conventional digital mammography technology via relatively simple modifications; and fast acquisition time. One significant problem that tomosynthesis of the breast must overcome, however, is the reduction of x‐ray scatter inclusion in the projection images. In tomosynthesis, due to the projection geometry and radiation dose considerations, the use of an antiscatter grid presents several challenges. Therefore, the use of postacquisition software‐based scatter reduction algorithms seems well justified, requiring a comprehensive evaluation of x‐ray scatter content in the tomosynthesis projections. This study aims to gain insight into the behavior of x‐ray scatter in tomosynthesis by characterizing the scatter point spread functions (PSFs) and the scatter to primary ratio (SPR) maps found in tomosynthesis of the breast. This characterization was performed using Monte Carlo simulations, based on the Geant4 toolkit, that simulate the conditions present in a digital tomosynthesis system, including the simulation of the compressed breast in both the cranio‐caudal (CC) and the medio‐lateral oblique (MLO) views. The variation of the scatter PSF with varying tomosynthesis projection angle, as well as the effects of varying breast glandular fraction and x‐ray spectrum, was analyzed. The behavior of the SPR for different projection angle, breast size, thickness, glandular fraction, and x‐ray spectrum was also analyzed, and computer fit equations for the magnitude of the SPR at the center of mass for both the CC and the MLO views were found. Within mammographic energies, the x‐ray spectrum was found to have no appreciable effect on the scatter PSF and on the SPR. Glandular fraction and compressed breast size were found to have a small effect, while compressed breast thickness and projection angle, as expected, introduced large variations in both the scatter PSF and SPR. The presence of the breast support plate and the detector cover plate in the simulations introduced important effects on the SPR, which are also relevant to the scatter content in planar mammography.


  • Open Access

    Computation of the glandular radiation dose in digital tomosynthesis of the breast

    by Ioannis Sechopoulos, Sankararaman Suryanarayanan, Srinivasan Vedantham, Carl D'ORsi, Andrew Karellas

    Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x‐ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the to the breast tissue was computed for varying x‐ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio‐caudal (CC) and medio‐lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammographic energies, the RGD was found to have a weak dependence on glandular fraction and x‐ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided.


  • Solid‐state fluoroscopic imager for high‐resolution angiography: Physical characteristics of an 8 cm×8 cm experimental prototype

    by Srinivasan Vedantham, Andrew Karellas, Sankararaman Suryanarayanan, Steven K. Onishi

    In this paper, the performance of an 8 cm×8 cm three‐side buttable charge‐coupled device (CCD)‐based imager specially designed for high‐resolution fluoroscopy and operating in fluoroscopic (30 frames/second) mode is presented in terms of the presampling modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). The 8 cm×8 cm CCD imager is coupled to a 450 μm thick CsI:Tl scintillator by nondemagnifying (straight, 1:1) fiberoptics. The CCD imager has a fundamental pixel pitch of 39 μm and incorporates an optically opaque interline (data) channel. The CCD imager was operated at 156 μm pixel pitch by binning 4×4 adjacent pixels prior to readout. The fluoroscopic image lag was measured and accounted for in the DQE estimate to provide lag‐corrected DQE. The measured limiting spatial resolution at 10% presampling MTF with the imager operated at 156 μm pixel pitch (Nyquist sampling limit: 3.21 cy/mm) was 3.6 cy/mm. In the pulsed fluoroscopic mode, the first‐frame image lag was less than 0.9%. The lag‐corrected DQE(0) of ∼0.62 was achieved even at a low fluoroscopic exposure rate of 1 μR/frame. Grid phantom measurements indicate no appreciable distortion. Results from DQE and image lag measurements at fluoroscopic exposure rates combined with the high spatial resolution observed from the MTF suggest that this type of imager or its variants may be a potential candidate for high‐resolution neuro‐interventional imaging, cardiovascular imaging, pediatric angiography, and small animal imaging. Since the CCD is three‐side buttable, four such CCD modules can be joined to form a 2×2 matrix providing a field of view of 16 cm×16 cm.


  • Solid‐state fluoroscopic imager for high‐resolution angiography: Parallel‐cascaded linear systems analysis

    by Srinivasan Vedantham, Andrew Karellas, Sankararaman Suryanarayanan

    Cascaded linear systems based modeling techniques have been used in the past to predict important system parameters that have a direct impact on image quality. Such models are also useful in optimizing system parameters to improve image quality. In this work, detailed analysis of a solid‐state fluoroscopic imaging system intended for high‐resolution angiography is presented with the use of such a model. The imaging system analyzed through this model uses four 8×8 cm three‐side buttable interlined charge‐coupled devices (CCDs) specifically designed for high‐resolution angiography and tiled in a seamless fashion to achieve a field of view (FOV) of 16×16 cm. Larger FOVs can be achieved by tiling more CCDs in a similar manner. The system employs a CsI:Tl scintillator coupled to the CCDs by straight (nontapering) fiberoptics and can potentially be operated in 78, 156, or 234 μm pixel pitch modes. The system parameters analyzed through this model include presampling modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE). The results of the simulations performed indicate that DQE(0) in excess of 0.6 is achievable, with the imager operating at 156 μm pixel pitch, 30 frames/s, and employing a 450‐μm‐thick CsI:Tl scintillator, even at a low fluoroscopic exposure rate of 1 μR/frame. Further, at a nominal fluoroscopic exposure rate of 2.5 μR/frame there was no noticeable degradation of the DQE even at the 78 μm pixel pitch mode suggesting that it is feasible to perform high‐resolution angiography hitherto unattainable in clinical practice.


  • A Perceptual Evaluation of JPEG 2000 Image Compression for Digital Mammography: Contrast-Detail Characteristics

    by Sankararaman Suryanarayanan, Andrew Karellas, Srinivasan Vedantham, Sandra M. Waldrop, Carl J. D’oRsi

    In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using a commercially available software product (JPEG 2000). Data compression was achieved at ratios of 1:1, 10:1, 20:1, and 30:1 and the images were reviewed by seven observers on a high-resolution display. Psychophysical detection characteristics were first computed by fitting perception data using a maximum-likelihood technique from which CD curves were derived at 50%, 62.5%, and 75% threshold levels. Statistical analysis indicated no significant difference in the perception of mean disk thickness up to 20:1 compression except for disk diameter of 1 mm. All other compression combinations exhibited significant degradation in CD characteristics.