A Perceptual Evaluation of JPEG 2000 Image Compression for Digital Mammography: Contrast-Detail Characteristics
- 18 February 2004
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 17 (1) , 64-70
Abstract
In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using a commercially available software product (JPEG 2000). Data compression was achieved at ratios of 1:1, 10:1, 20:1, and 30:1 and the images were reviewed by seven observers on a high-resolution display. Psychophysical detection characteristics were first computed by fitting perception data using a maximum-likelihood technique from which CD curves were derived at 50%, 62.5%, and 75% threshold levels. Statistical analysis indicated no significant difference in the perception of mean disk thickness up to 20:1 compression except for disk diameter of 1 mm. All other compression combinations exhibited significant degradation in CD characteristics.Keywords
This publication has 22 references indexed in Scilit:
- The value of scatter removal by a grid in full field digital mammographyMedical Physics, 2003
- Flat-Panel Digital Mammography System: Contrast-Detail Comparison between Screen-Film Radiographs and Hard-Copy ImagesRadiology, 2002
- Clinical Evaluation of Compression Ratios using JPEG2000 on Computed Radiography Chest ImagesJournal of Digital Imaging, 2002
- Comparison of low contrast detectability between a digital amorphous silicon and a screen‐film based imaging system for thoracic radiographyMedical Physics, 1999
- Clinical evaluation of irreversible data compression for computed radiography of the chestJournal of Digital Imaging, 1998
- An introduction to wavelet theory and application for the radiological physicistMedical Physics, 1998
- A brief review of human perception factors in digital displays for picture archiving and communications systemsJournal of Digital Imaging, 1997
- Digital tomosynthesis in breast imaging.Radiology, 1997
- Contrast-detail detectability analysis: Comparison of a digital spot mammography system and an analog screen-film mammography systemAcademic Radiology, 1997
- Image compression in digital mammography: Effects on computerized detection of subtle microcalcificationsMedical Physics, 1996