Brittney C. Muir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Brittney C. Muir has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Kimberly A. Nickerson
VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, 1660 S Columbian Way, MS 151, Seattle, WA, 98108, USA; Department of Mechanical Engineering, University of Washington, 3900 E Stevens Way NE, Box 352600, Seattle, WA, 98195, USA
6 shared publicationsScott Telfer
VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, 1660 S Columbian Way, MS 151, Seattle, WA, 98108, USA; Department of Mechanical Engineering, University of Washington, 3900 E Stevens Way NE, Box 352600, Seattle, WA, 98195, USA; Department of Orthopedics and Sports Medicine, University of Washington, 1959 NE Pacific St., Box 356500, Seattle, WA, 98195, USA
6 shared publicationsWilliam R. Ledoux
VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, 1660 S Columbian Way, MS 151, Seattle, WA, 98108, USA; Department of Mechanical Engineering, University of Washington, 3900 E Stevens Way NE, Box 352600, Seattle, WA, 98195, USA; Department of Orthopedics and Sports Medicine, University of Washington, 1959 NE Pacific St., Box 356500, Seattle, WA, 98195, USA
5 shared publicationsChristina Carranza
BRITTNEY C. MUIR, PhD; CHRISTINA CARRANZA; JING-SHENG LI; and PATRICK M. AUBIN, are affiliated with VA RR&D Center for Limb Loss and MoBility (CLiMB), VA Puget Sound Health Care System, Seattle, WA, USA
4 shared publicationsJ.M. Haddad
Department of Health and Kinesiology, Purdue University, West Lafayette, IN, USA; Center for Aging and the Life Course, Purdue University, West Lafayette, IN, USA
3 shared publicationsJing-Sheng Li
BRITTNEY C. MUIR, PhD; JING-SHENG LI; and PATRICK M. AUBIN, are affiliated with Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
3 shared publications
Latest Publications
- 23 June 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 181, 107515
Durability and offloading performance of 3D-printed multilayer lattice for accommodative insoles
- 23 June 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 181, 107515
Durability and offloading performance of 3D-printed multilayer lattice for accommodative insoles
- 1 June 2026
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
- Vol. 38  (3) , 178-184
Navigating Conservative Strategies for Ankle Osteoarthritis Treatment: Understanding Footwear Preference—Rocker Bottom Shoes and Ankle Foot Orthotics
Background: Ankle osteoarthritis (AOA) is a progressive condition that impairs mobility and reduces quality of life. Conservative treatments like rocker bottom (RB) shoes and ankle-foot orthoses (AFOs) are commonly prescribed, but their effectiveness in managing AOA is not well understood, and patient preferences are underexplored. Objectives: This is a pilot study aimed to evaluate the effect of RB shoes and AFOs in managing AOA and to identify factors influencing patient preferences for these conservative treatments. Study Design: This was a cross-over telehealth study involving 10 participants with doctor-diagnosed AOA. Each participant wore three footwear conditions: control shoes, RB shoes, and AFOs, each for 3 weeks. Methods: Participants completed baseline pain ratings and functional assessments using PROMIS and FAAM questionnaires. After each 3-week footwear session, participants reported pain levels and provided feedback on their preferred footwear. Results: Younger participants (aged 56–63) preferred AFOs for pain relief and improved mobility, while older (aged 66–75) and taller participants preferred RB shoes for their comfort. No significant differences were found in pain or function across footwear conditions, but AFO-preferred participants experienced significant reductions in maximum pain compared to the RB group. Conclusions: Footwear preferences were influenced by age and activity level. Younger participants preferred AFOs for functional benefits, while older participants prioritized comfort and selected RB shoes. These findings emphasize the need for personalized conservative treatment strategies in managing AOA. Clinical relevance statement: This pilot study highlights the importance of tailoring conservative treatments for AOA based on age and activity level. Understanding patient preferences can help guide clinical decisions and improve patient outcomes.
- 1 June 2026
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
- Vol. 38  (3) , 178-184
Navigating Conservative Strategies for Ankle Osteoarthritis Treatment: Understanding Footwear Preference—Rocker Bottom Shoes and Ankle Foot Orthotics
Background: Ankle osteoarthritis (AOA) is a progressive condition that impairs mobility and reduces quality of life. Conservative treatments like rocker bottom (RB) shoes and ankle-foot orthoses (AFOs) are commonly prescribed, but their effectiveness in managing AOA is not well understood, and patient preferences are underexplored. Objectives: This is a pilot study aimed to evaluate the effect of RB shoes and AFOs in managing AOA and to identify factors influencing patient preferences for these conservative treatments. Study Design: This was a cross-over telehealth study involving 10 participants with doctor-diagnosed AOA. Each participant wore three footwear conditions: control shoes, RB shoes, and AFOs, each for 3 weeks. Methods: Participants completed baseline pain ratings and functional assessments using PROMIS and FAAM questionnaires. After each 3-week footwear session, participants reported pain levels and provided feedback on their preferred footwear. Results: Younger participants (aged 56–63) preferred AFOs for pain relief and improved mobility, while older (aged 66–75) and taller participants preferred RB shoes for their comfort. No significant differences were found in pain or function across footwear conditions, but AFO-preferred participants experienced significant reductions in maximum pain compared to the RB group. Conclusions: Footwear preferences were influenced by age and activity level. Younger participants preferred AFOs for functional benefits, while older participants prioritized comfort and selected RB shoes. These findings emphasize the need for personalized conservative treatment strategies in managing AOA. Clinical relevance statement: This pilot study highlights the importance of tailoring conservative treatments for AOA based on age and activity level. Understanding patient preferences can help guide clinical decisions and improve patient outcomes.
- Open Access
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Durability and Offloading Performance of 3D-Printed Multilayer Lattice for Accommodative Insoles
Custom accommodative insoles fabricated from multilayer foams are the standard of care (SoC) for offloading elevated plantar pressures in individuals with diabetes at risk of foot ulceration. While SoC insoles have demonstrated short-term effectiveness, they are prone to permanent material deformation over time, reducing their offloading efficacy. Recent work has shown that 3D-printed multilayer lattice structures using elastomeric polyurethane (EPU) can match the mechanical properties of SoC foams and is effective in reducing plantar pressures. However, their long-term pressure offloading performance and durability have not been investigated. In this study, 3D-printed EPU multilayer lattice pucks and SoC multilayer foam pucks, with and without designed offloading regions, underwent one million cycles of sinusoidal compressive loading under both uniform and uneven loading conditions. Peak pressure (PP), pressure time integral (PTI), residual thickness, and elastic modulus were assessed at multiple timepoints throughout testing. Under uniform loading, both materials maintained stable PPs below the 200 kPa clinical threshold across one million cycles. Under uneven loading, SoC pucks exhibited progressive pressure increases and residual thickness reductions of up to 36%, while 3D-printed pucks maintained structural integrity with thickness reductions of 3% or less and demonstrated beneficial mechanical settling that reduced PP over time. Both materials with designed offloading regions effectively maintained PPs below 150 kPa throughout testing. These findings support 3D-printed multilayer lattice insole materials as a durable and effective long-term strategy for plantar pressure management in high-risk diabetic populations.
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDurability and Offloading Performance of 3D-Printed Multilayer Lattice for Accommodative Insoles
Custom accommodative insoles fabricated from multilayer foams are the standard of care (SoC) for offloading elevated plantar pressures in individuals with diabetes at risk of foot ulceration. While SoC insoles have demonstrated short-term effectiveness, they are prone to permanent material deformation over time, reducing their offloading efficacy. Recent work has shown that 3D-printed multilayer lattice structures using elastomeric polyurethane (EPU) can match the mechanical properties of SoC foams and is effective in reducing plantar pressures. However, their long-term pressure offloading performance and durability have not been investigated. In this study, 3D-printed EPU multilayer lattice pucks and SoC multilayer foam pucks, with and without designed offloading regions, underwent one million cycles of sinusoidal compressive loading under both uniform and uneven loading conditions. Peak pressure (PP), pressure time integral (PTI), residual thickness, and elastic modulus were assessed at multiple timepoints throughout testing. Under uniform loading, both materials maintained stable PPs below the 200 kPa clinical threshold across one million cycles. Under uneven loading, SoC pucks exhibited progressive pressure increases and residual thickness reductions of up to 36%, while 3D-printed pucks maintained structural integrity with thickness reductions of 3% or less and demonstrated beneficial mechanical settling that reduced PP over time. Both materials with designed offloading regions effectively maintained PPs below 150 kPa throughout testing. These findings support 3D-printed multilayer lattice insole materials as a durable and effective long-term strategy for plantar pressure management in high-risk diabetic populations.
- Open Access
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Predictive Performance of Static Plantar Pressure Measurements for Identifying High-Pressure Regions During Shod Walking
Foot ulceration is a serious complication of diabetes and associated with elevated plantar pressures during walking. Custom accommodative insoles are most effective when informed by dynamic pressure data; however, static pressure collection offers a faster and more clinically feasible alternative. The ability of static pressure measurements to predict dynamic high-pressure regions remains unclear and needs investigation.This study compared peak plantar pressure, sensor-level correlations, and predictive performance of static pressure thresholds from static in-shoe and static barefoot data relative to dynamic in-shoe data. Plantar pressures were collected from 31 feet in 18 participants with elevated dynamic in-shoe forefoot pressures. Dynamic high-pressure regions were defined as regions exceeding 200 kPa. Sensor-level correlations were calculated, and receiver operating characteristic curves were used to determine static thresholds. Agreement metrics, including Dice coefficient, sensitivity, and positive predictive value, were evaluated.Sensor-level Pearson and Spearman correlations were higher for static versus dynamic in-shoe data than for static barefoot comparisons (p<0.001). Static thresholds were 40.4 and 55.8 kPa for in-shoe and barefoot data respectively. Despite moderate to strong correlations, Dice coefficients were low, indicating minimal spatial overlap between static and dynamic high-pressure regions. High sensitivity with low positive predictive value demonstrated that static thresholds overestimated the location and extent of dynamic high-pressure regions.These findings indicate that static pressure measurements, despite improved clinical feasibility, cannot reliably identify dynamic in-shoe high-pressure regions. Insole design based on static pressures may lead to overly conservative offloading and reduced specificity, reinforcing the need for dynamic pressure data in clinical practice.
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPredictive Performance of Static Plantar Pressure Measurements for Identifying High-Pressure Regions During Shod Walking
Foot ulceration is a serious complication of diabetes and associated with elevated plantar pressures during walking. Custom accommodative insoles are most effective when informed by dynamic pressure data; however, static pressure collection offers a faster and more clinically feasible alternative. The ability of static pressure measurements to predict dynamic high-pressure regions remains unclear and needs investigation.This study compared peak plantar pressure, sensor-level correlations, and predictive performance of static pressure thresholds from static in-shoe and static barefoot data relative to dynamic in-shoe data. Plantar pressures were collected from 31 feet in 18 participants with elevated dynamic in-shoe forefoot pressures. Dynamic high-pressure regions were defined as regions exceeding 200 kPa. Sensor-level correlations were calculated, and receiver operating characteristic curves were used to determine static thresholds. Agreement metrics, including Dice coefficient, sensitivity, and positive predictive value, were evaluated.Sensor-level Pearson and Spearman correlations were higher for static versus dynamic in-shoe data than for static barefoot comparisons (p<0.001). Static thresholds were 40.4 and 55.8 kPa for in-shoe and barefoot data respectively. Despite moderate to strong correlations, Dice coefficients were low, indicating minimal spatial overlap between static and dynamic high-pressure regions. High sensitivity with low positive predictive value demonstrated that static thresholds overestimated the location and extent of dynamic high-pressure regions.These findings indicate that static pressure measurements, despite improved clinical feasibility, cannot reliably identify dynamic in-shoe high-pressure regions. Insole design based on static pressures may lead to overly conservative offloading and reduced specificity, reinforcing the need for dynamic pressure data in clinical practice.
- 8 February 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 199, 113201
Quantifying differences in high-pressure region mapping between dynamic in-shoe and barefoot plantar pressure in diabetic subjects
- 8 February 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 199, 113201
Quantifying differences in high-pressure region mapping between dynamic in-shoe and barefoot plantar pressure in diabetic subjects
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29  (12) , 9259-9270
Deep Learning-Based Stride Segmentation With Wearable Sensors: Effects of Data Quantity, Sensor Location, and Task
Accurate stride segmentation from wearable sensors is foundational for digital gait assessment tools, yet systematic evaluations of deep learning approaches across varied mobility tasks remain limited. We developed and assessed Temporal Convolutional Network (TCN) models for stride segmentation using data from 121 older adults with and without Parkinson's disease, specifically evaluating how performance varies with model development data quantity, sensor location, and movement complexity. Using a fixed-size test set of 40 participants, we found that lower limb sensors achieved F1scores above95%duringwalking with just 5–10 training participants, but performance declined substantially during more complex movements such as 180° turns. Foot-mounted sensors maintained robust performance across tasks (F1: 99.3% walking, 96.7% turning, 88.4% stationary and transitional movements), while wrist sensors showed marked degradation (F1: 88.4% walking, 72.3% turning, 50.0% stationary and transitional movements). Our findings demonstrate that it is important to tailor performance testing for digital gait assessment tools to both sensor location and use case, as performance achieved during controlled walking may not generalize to complex movements in daily life.
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29  (12) , 9259-9270
Deep Learning-Based Stride Segmentation With Wearable Sensors: Effects of Data Quantity, Sensor Location, and Task
Accurate stride segmentation from wearable sensors is foundational for digital gait assessment tools, yet systematic evaluations of deep learning approaches across varied mobility tasks remain limited. We developed and assessed Temporal Convolutional Network (TCN) models for stride segmentation using data from 121 older adults with and without Parkinson's disease, specifically evaluating how performance varies with model development data quantity, sensor location, and movement complexity. Using a fixed-size test set of 40 participants, we found that lower limb sensors achieved F1scores above95%duringwalking with just 5–10 training participants, but performance declined substantially during more complex movements such as 180° turns. Foot-mounted sensors maintained robust performance across tasks (F1: 99.3% walking, 96.7% turning, 88.4% stationary and transitional movements), while wrist sensors showed marked degradation (F1: 88.4% walking, 72.3% turning, 50.0% stationary and transitional movements). Our findings demonstrate that it is important to tailor performance testing for digital gait assessment tools to both sensor location and use case, as performance achieved during controlled walking may not generalize to complex movements in daily life.
- 20 August 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 129, 106653
Effects of standard of care and pressure-based 3D-printed custom accommodative insoles on static balance in individuals with diabetes: A pilot study
- 20 August 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 129, 106653
Effects of standard of care and pressure-based 3D-printed custom accommodative insoles on static balance in individuals with diabetes: A pilot study
- Open Access
Improving Offloading in Diabetic Feet: 3D-Printed Custom Accommodative Insoles Outperform Standard of Care
Objective 3D-printed custom accommodative insoles may offer improved plantar pressure offloading compared to standard-of-care insoles for individuals with diabetes. We have developed two versions of 3D-printed accommodative insoles that have patient-specific geometries as well as patient-specific stiffnesses and structural behaviors. This study evaluated two 3D-printed custom accommodative insoles against standard-of-care and no insole. Research Design and Methods This in-laboratory clinical trial enrolled 25 adults with diabetes and high plantar pressure. Participants completed over-ground walking trials under the following conditions: no insole, standard-of-care insoles, pressure-based insoles, and finite element insoles. Peak plantar pressure and pressure-time integral were measured in high-risk regions of interest and adjacent regions. Participant comfort and preference were recorded. Results All insoles significantly reduced peak pressure and pressure-time integral in the regions of interest compared to no insole (pHighlights Why did we undertake this study? Individuals with diabetes and high plantar pressure are at risk for foot complications, and current insoles may not provide sufficient pressure relief. What is the specific question(s) we wanted to answer? Can two types of 3D-printed custom accommodative insoles—pressure-based and finite element designs—provide superior plantar pressure offloading compared to standard-of-care and no insole conditions? What did we find? Both 3D-printed insole types significantly outperformed standard-of-care insoles in reducing peak plantar pressure and pressure-time integral in the region of interest. Finite element designs also reduced pressure in adjacent regions. What are the implications of our findings? Personalized 3D-printed insoles may improve diabetic foot care by offering targeted offloading. Optimizing fit and comfort is needed before broader clinical use.
Open AccessImproving Offloading in Diabetic Feet: 3D-Printed Custom Accommodative Insoles Outperform Standard of Care
Objective 3D-printed custom accommodative insoles may offer improved plantar pressure offloading compared to standard-of-care insoles for individuals with diabetes. We have developed two versions of 3D-printed accommodative insoles that have patient-specific geometries as well as patient-specific stiffnesses and structural behaviors. This study evaluated two 3D-printed custom accommodative insoles against standard-of-care and no insole. Research Design and Methods This in-laboratory clinical trial enrolled 25 adults with diabetes and high plantar pressure. Participants completed over-ground walking trials under the following conditions: no insole, standard-of-care insoles, pressure-based insoles, and finite element insoles. Peak plantar pressure and pressure-time integral were measured in high-risk regions of interest and adjacent regions. Participant comfort and preference were recorded. Results All insoles significantly reduced peak pressure and pressure-time integral in the regions of interest compared to no insole (pHighlights Why did we undertake this study? Individuals with diabetes and high plantar pressure are at risk for foot complications, and current insoles may not provide sufficient pressure relief. What is the specific question(s) we wanted to answer? Can two types of 3D-printed custom accommodative insoles—pressure-based and finite element designs—provide superior plantar pressure offloading compared to standard-of-care and no insole conditions? What did we find? Both 3D-printed insole types significantly outperformed standard-of-care insoles in reducing peak plantar pressure and pressure-time integral in the region of interest. Finite element designs also reduced pressure in adjacent regions. What are the implications of our findings? Personalized 3D-printed insoles may improve diabetic foot care by offering targeted offloading. Optimizing fit and comfort is needed before broader clinical use.
- 5 August 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 129, 106645
Pathways of load transfer in custom accommodative insoles for people with diabetes
- 5 August 2025
- Published by Elsevier in Clinical Biomechanics
- Vol. 129, 106645
Pathways of load transfer in custom accommodative insoles for people with diabetes
- 12 April 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 185, 112692
Age-Related changes in joint power during gait: Adaptations in middle-aged adults to maintain walking speed
- 12 April 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 185, 112692
Age-Related changes in joint power during gait: Adaptations in middle-aged adults to maintain walking speed