ASAhmed Mohamed Suliman

Ahmed Mohamed Suliman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed Mohamed Suliman has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Analysis of Salivary Tumor Marker CA-125 Among Oral Squamous Cell Carcinoma Patients and Healthy Individuals

    by Riham Mohammed, Mariam El Sheikh, Nada Tawfig Hashim, Nallan Csk Chaitanya, Ahmed Suleiman

    Background/Objectives: In Sudan, oral cancer is one of the top ten most common cancers, with OSCC representing the majority of the cases. To date, despite the fact that saliva can be collected simply and non-invasively, there is no approved salivary tumor marker for OSCC. This study aimed to investigate the reliability of salivary CA-125 as a tumor marker for OSCC by measuring and comparing its level among OSCC and healthy individuals as well as its level across different histopathological grades. Methods: A total of 100 subjects were enrolled; 50 were patients with OSCC, while the other 50 were matched healthy individuals. Non-stimulated whole saliva was collected before the administration of definitive treatment, and the concentration of salivary CA-125 was quantified using an automated immunoassay analyzer that employs a one-step sandwich fluorescent enzyme immunoassay (FEIA). Results: The level of salivary CA-125 was 342.65 U/mL in the cases group, which was significantly increased compared with 203.65 U/mL in the healthy controls (p = 0.017). Statistically significant differences in the level of salivary CA-125 among different histopathological grades were observed (p = 0.014). The sensitivity, specificity, accuracy, and positive and negative predictive values were 48%, 78%, 63%, 68.6%, and 60%, respectively. Conclusions: This study suggests that salivary CA-125 could serve as a potential tumor marker for OSCC. However, its clinical application requires further validation.


  • Platelet Lymphocyte Ratio as a Prognosticator in Oral Cancer Patients

    by Bahiya Elrashid Khalid Hamad, Yousif I. Eltohami, Ahmed Mohamed Suleiman

    Objective To study the prognostic predictive value of the platelet lymphocyte ratio as a clinical parameter of the outcome of the Sudanese OSCC patients. Method Forty two oral cancer patients were selected for the study. The patients surgically managed in the period December 2018 to June 2020. The PLR was recorded and correlated with :the status of surgical margins, the lymphovascular invasion, the extranodal extension, the microscopic depth and the patient’s survival (dead/ alive). Result A ratio of 170 was considered to be a cut off point of the PLR; as patients with a ratio higher than 170 were found to have a bad prognosis. Twenty-four patients (59.5%) had a PLR higher than 170. Patients with PLR equal to 170 or less have 45% decrease in the odds of survival and 57% decrease in the odds of having positive lymph nodes. Thirty-three percent passed away. Conclusion The PLR is an affordable, practical and efficient way to predict an OSCC patient’s overall survival.


  • Open Access

    The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study

    by Motaz Osman, Neamat Hassan Abubakr, Ahmed Suliman, Hassan Ziada

    Aim: This in vitro study aimed to evaluate the effect of implant impression coping geometrical designs on the accuracy of open and closed impression techniques and in the parallel and nonparallel implant positions. Material and methods: Three custom-made acrylic resin models of three tested implant systems (Straumann®, SIC Invent®, and Osstem®) with diverse coping geometrical designs were evaluated in simulated cases of two parallel and two nonparallel implants. The horizontal and vertical discrepancies were measured and analyzed. Results: No statistically significant differences between the two impression techniques in either parallel or nonparallel implants were observed. The high retentive design of the Osstem system showed a statistically significant difference. Conclusion: The geometrical design of the impression copings did not affect the accuracy for either the open and closed tray techniques. However, the high retentive coping design of the Osstem implant affected the accuracy in the open tray technique.


  • Open Access

    Rehabilitation of an irradiated marginal mandibulectomy patient using immediately loaded basal implant-supported fixed prostheses and hyperbaric oxygen therapy: A 2-year follow-up

    by Fadia Awadalkreem, Nadia Khalifa, Abdelnasir G. Ahmad, Ahmed Mohamed Suliman, Motaz Osman

    The prosthetic rehabilitation of mandibular defects owing to tumor resection is challenging, especially when the patient has undergone subsequent radiotherapy. A 46-year old male presented with a marginal mandibular resection. Following surgery, the patient received adjunctive radiation therapy with a total dose of 70 grays. On clinical examination, the patient presented with severely resorbed edentulous jaws, with an anterior marginal mandibular resection and an obliterated vestibular sulcus. The panoramic radiograph showed a hypocellularity of the maxillary and mandibular bones. A multidisciplinary team was formed, and a treatment plan was formulated which involved the construction of a vestibuloplast stent, and the application of 20 hyperbaric oxygen sessions before implant treatment and 10 more sessions after implant insertion. A total of 16 basal cortical screw implants were inserted to support the fixed prostheses, and a vestibuloplasty was performed to improve esthetics. No complications were observed, and at the 2-year follow-up, the patient presented with excellent peri-implant soft tissue health; increased bone-implant contact; and stable, well-functioning prostheses. The construction of a stable, retentive, well-supported removable prosthesis may be complicated in cases of comprehensive mandibular resection. Basal implants can eliminate the need for bone grafting, and reduce the treatment period required for providing a fixed prosthesis. To our knowledge this is the first evidence reporting the use of fixed basal implant-supported prostheses in irradiated bone, in conjunction with hyperbaric oxygen therapy. A treatment modality that significantly improves the peri-implant tissue health, and ensures an excellent implant-bone contact.


  • Open Access

    Prosthetic rehabilitation of maxillary and mandibular gunshot defects with fixed basal implant-supported prostheses

    by Fadia Awadalkreem, Nadia Khalifa, Abdelnasir G. Ahmad, Ahmed Mohamed Suliman, Motaz Osman

    Introduction: Gunshot injuries to the oral maxillofacial region have serious aesthetic and functional consequences. Presentation of case: A 32-year-old male patient presented with a marginal mandibular resection owing to a gunshot wound. A clinical examination revealed destroyed crowns in teeth 12, 11, and 21; extraction in teeth 13, 22, 24, 31, 32-45; a fracture in tooth 38; and severe pain. Further, he had multiple submental scars and a completely obliterated sulcus. Consequently, a multidisciplinary team was formed who devised the following treatment plan: stage 1, root canal treatment for the maxillary anterior teeth, followed by crown construction and transitional mandibular removable partial denture construction, and stage 2, placement of immediately loaded basal implant definitive prostheses supported by 6 corticobasal screw implants. After 5 years of use, the patient presented with excellent peri-implant soft tissue health, prosthesis stability, and great improvements in aesthetics and function. The patient was highly satisfied with the treatment and restoration of his quality of life. Discussion: Accurate treatment planning is vital for managing complicated cases, including gunshot defect cases, and should involve the selection of the most suitable reconstructive technique with lower susceptible complication rates and high success rates. The described treatment eliminates the need for bone grafting, reduces treatment duration, and involves fixed prosthesis placement. Conclusion: To our knowledge, this is the first report on basal implant-based full-mouth rehabilitation in a gunshot mandibular defect patient. The fixed hybrid basal implant-supported prosthesis produced highly acceptable aesthetic and phonetic results and greatly improved the patient’s life. Highlights:


  • Open Access

    A prospective clinical study on implant impression accuracy

    by Motaz Osman, Hassan Ziada, Ahmed Suliman, Neamat Hassan Abubakr

    Background: An accurate impression is crucial to the long-term success of dental implants. This investigation evaluated the accuracy of the open and closed implant impression techniques in partially edentulous patients who received two adjacent implants. Material and methods: Forty patients received Osstem Implants (Osstem Implant System, Seoul, Korea). Two impressions were made for each patient, one using an open tray and a second with a closed tray technique. The horizontal distances between two impression copings were measured and compared to similar measurements on the master casts. Also, under a stereomicroscope (AmScop14370, Myford Road, #150, Irvine, CA 92606 USA) at a 50-fold magnification, the presence or absence of the marginal discrepancies was evaluated. Results: There were no statistically significant differences regarding horizontal measurements and in the marginal relationship for the two impression techniques, except between the anterior and posterior regions, for the closed tray technique. There were also no statistically significant differences in the impression accuracy between maxillary and the mandibular arches. In addition, there were no statistically significant differences for the intraoral horizontal distances, compared to similar horizontal measurements on master casts, between the open and closed tray techniques. Conclusions: Within the limitations of the present study, there were generally no differences in the impression accuracy between the open and closed tray techniques in partially edentulous patients with two adjacent implants.


  • Open Access

    Implant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed tray techniques

    by Motaz S. Osman, Hassan M. Ziada, Neamat H. Abubakr, Ahmed M. Suliman

    The outcome of the evaluation of impression techniques accuracy may improve the selection criteria for an ideal technique. The aim was to evaluate the accuracy of the open and closed tray techniques for implant impressions, in a partially edentulous maxilla, replaced with a three-unit fixed partial denture, as well as to assess the effect of implants parallelism on accuracy. This is an experimental in vitro study to evaluate impressions accuracy of a simulated area restored with an implant retained FPD, using the open and closed tray implant impression techniques. The effect of implant position angulation, parallelism, and implant systems (Straumann, SIC Invent, Osstem) was also evaluated. Three custom-made acrylic resin test models were prepared with two parallel and two non-parallel implants, on either side of a maxillary arch. One hundred and ninety-two impressions were made using monophase VPS impression material. Their master casts were obtained and evaluated for the horizontal and vertical discrepancy. The casts were scanned using a model scanner. The distances between the two reference points were measured. The Straumann and SIC Invent implants showed no statistically significant differences (Mann-Whitney U test), regarding accuracy for both the open and closed tray impression techniques (P = 0.667 and P = 0.472). There were no significant differences for the parallel and non-parallel implants (P = 0.323 and P = 0.814), respectively, while the Osstem system showed statistically significant differences for both the open and closed tray impression techniques (P = 0.035) and between the parallel and non-parallel implants (P = 0.045). For the vertical discrepancies, significant differences were detected (chi-square test) between the open and closed tray impression techniques (P = 0.037). Within the limitations of this study, there were generally no significant differences between open and closed, although better results were obtained for the open tray techniques. On the use of the non-parallel implants, the open tray technique provided a better result than the closed tray technique.