Motaz Osman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Motaz Osman has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Mohamed Suliman
Department of Oral Maxillofacial Surgery, University of Khartoum, Khartoum, Sudan
3 shared publications - Hassan Ziada
Clinical Science Department, School of Dental Medicine, University of Nevada, 1001 Shadow Lane, Las Vegas, NV 89106, USA
3 shared publications - Neamat Hassan Abubakr
Biomedical Sciences Department, School of Dental Medicine, University of Nevada, Las Vegas, NV 89106, USA
3 shared publications - Fadia Awadalkreem
Department of Prosthodontics, RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al Khaimah, United Arab Emirates (UAE)
2 shared publications - Abdelnasir G Ahmad
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, International University of Africa, Khartoum, Sudan
1 shared publication - Abdelnasir Gafar Ahmad
International University of Africa, Oral and Maxillofacial Surgery Department, Khartoum, Sudan
1 shared publication
Latest Publications
- Open Access
- 10 October 2020
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 6 (1) , 1-10
The impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
Aim: This in vitro study aimed to evaluate the effect of implant impression coping geometrical designs on the accuracy of open and closed impression techniques and in the parallel and nonparallel implant positions. Material and methods: Three custom-made acrylic resin models of three tested implant systems (Straumann®, SIC Invent®, and Osstem®) with diverse coping geometrical designs were evaluated in simulated cases of two parallel and two nonparallel implants. The horizontal and vertical discrepancies were measured and analyzed. Results: No statistically significant differences between the two impression techniques in either parallel or nonparallel implants were observed. The high retentive design of the Osstem system showed a statistically significant difference. Conclusion: The geometrical design of the impression copings did not affect the accuracy for either the open and closed tray techniques. However, the high retentive coping design of the Osstem implant affected the accuracy in the open tray technique.
- 10 October 2020
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 6 (1) , 1-10
Open AccessThe impact of impression coping geometrical design on accuracy of implant impressions: an experimental study
Aim: This in vitro study aimed to evaluate the effect of implant impression coping geometrical designs on the accuracy of open and closed impression techniques and in the parallel and nonparallel implant positions. Material and methods: Three custom-made acrylic resin models of three tested implant systems (Straumann®, SIC Invent®, and Osstem®) with diverse coping geometrical designs were evaluated in simulated cases of two parallel and two nonparallel implants. The horizontal and vertical discrepancies were measured and analyzed. Results: No statistically significant differences between the two impression techniques in either parallel or nonparallel implants were observed. The high retentive design of the Osstem system showed a statistically significant difference. Conclusion: The geometrical design of the impression copings did not affect the accuracy for either the open and closed tray techniques. However, the high retentive coping design of the Osstem implant affected the accuracy in the open tray technique.
- Open Access
- 1 January 2020
- Published by Wiley in Case Reports in Dentistry
- Vol. 2020 (1) , 9650164
A Novel Approach for Rehabilitation of a Subtotal Maxillectomy Patient with Immediately Loaded Basal Implant‐Supported Prosthesis: 4 Years Follow‐Up
The prosthetic rehabilitation of maxillary defect can be achieved successfully by using an implant‐supported prosthesis. The use of remote bony areas such as the zygomatic bone in cases of large defects provides an innovative substitute for free vascularized osteocutaneous flaps and the solution to flap failures. This report describes the rehabilitation of a 22‐year‐old female with a subtotal maxillectomy using an immediately loaded basal implant‐supported prosthesis. Four basal cortical screw implants (BCS®) are inserted; 1 on the contralateral nasal floor, 2 implants in the pterygoid plates, and the last in the zygomatic bone using cone beam computed tomography scans. The prosthesis was constructed and cemented in 3 days. The surgical and prosthetic procedures were performed without any obstacles. After 4 years in function, the patient was highly satisfied with the treatment as it improved her mastication, speech, aesthetic and returned her self‐esteem. To our knowledge, this is the first clinical report detailing the use of basal implant‐retained obturator in a subtotal maxillectomy patient.
- 1 January 2020
- Published by Wiley in Case Reports in Dentistry
- Vol. 2020 (1) , 9650164
Open AccessA Novel Approach for Rehabilitation of a Subtotal Maxillectomy Patient with Immediately Loaded Basal Implant‐Supported Prosthesis: 4 Years Follow‐Up
The prosthetic rehabilitation of maxillary defect can be achieved successfully by using an implant‐supported prosthesis. The use of remote bony areas such as the zygomatic bone in cases of large defects provides an innovative substitute for free vascularized osteocutaneous flaps and the solution to flap failures. This report describes the rehabilitation of a 22‐year‐old female with a subtotal maxillectomy using an immediately loaded basal implant‐supported prosthesis. Four basal cortical screw implants (BCS®) are inserted; 1 on the contralateral nasal floor, 2 implants in the pterygoid plates, and the last in the zygomatic bone using cone beam computed tomography scans. The prosthesis was constructed and cemented in 3 days. The surgical and prosthetic procedures were performed without any obstacles. After 4 years in function, the patient was highly satisfied with the treatment as it improved her mastication, speech, aesthetic and returned her self‐esteem. To our knowledge, this is the first clinical report detailing the use of basal implant‐retained obturator in a subtotal maxillectomy patient.
- Open Access
- 19 November 2019
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 5 (1) , 1-7
A prospective clinical study on implant impression accuracy
Background: An accurate impression is crucial to the long-term success of dental implants. This investigation evaluated the accuracy of the open and closed implant impression techniques in partially edentulous patients who received two adjacent implants. Material and methods: Forty patients received Osstem Implants (Osstem Implant System, Seoul, Korea). Two impressions were made for each patient, one using an open tray and a second with a closed tray technique. The horizontal distances between two impression copings were measured and compared to similar measurements on the master casts. Also, under a stereomicroscope (AmScop14370, Myford Road, #150, Irvine, CA 92606 USA) at a 50-fold magnification, the presence or absence of the marginal discrepancies was evaluated. Results: There were no statistically significant differences regarding horizontal measurements and in the marginal relationship for the two impression techniques, except between the anterior and posterior regions, for the closed tray technique. There were also no statistically significant differences in the impression accuracy between maxillary and the mandibular arches. In addition, there were no statistically significant differences for the intraoral horizontal distances, compared to similar horizontal measurements on master casts, between the open and closed tray techniques. Conclusions: Within the limitations of the present study, there were generally no differences in the impression accuracy between the open and closed tray techniques in partially edentulous patients with two adjacent implants.
- 19 November 2019
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 5 (1) , 1-7
Open AccessA prospective clinical study on implant impression accuracy
Background: An accurate impression is crucial to the long-term success of dental implants. This investigation evaluated the accuracy of the open and closed implant impression techniques in partially edentulous patients who received two adjacent implants. Material and methods: Forty patients received Osstem Implants (Osstem Implant System, Seoul, Korea). Two impressions were made for each patient, one using an open tray and a second with a closed tray technique. The horizontal distances between two impression copings were measured and compared to similar measurements on the master casts. Also, under a stereomicroscope (AmScop14370, Myford Road, #150, Irvine, CA 92606 USA) at a 50-fold magnification, the presence or absence of the marginal discrepancies was evaluated. Results: There were no statistically significant differences regarding horizontal measurements and in the marginal relationship for the two impression techniques, except between the anterior and posterior regions, for the closed tray technique. There were also no statistically significant differences in the impression accuracy between maxillary and the mandibular arches. In addition, there were no statistically significant differences for the intraoral horizontal distances, compared to similar horizontal measurements on master casts, between the open and closed tray techniques. Conclusions: Within the limitations of the present study, there were generally no differences in the impression accuracy between the open and closed tray techniques in partially edentulous patients with two adjacent implants.
- Open Access
- 19 February 2019
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 5 (1) , 1-10
Implant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed tray techniques
The outcome of the evaluation of impression techniques accuracy may improve the selection criteria for an ideal technique. The aim was to evaluate the accuracy of the open and closed tray techniques for implant impressions, in a partially edentulous maxilla, replaced with a three-unit fixed partial denture, as well as to assess the effect of implants parallelism on accuracy. This is an experimental in vitro study to evaluate impressions accuracy of a simulated area restored with an implant retained FPD, using the open and closed tray implant impression techniques. The effect of implant position angulation, parallelism, and implant systems (Straumann, SIC Invent, Osstem) was also evaluated. Three custom-made acrylic resin test models were prepared with two parallel and two non-parallel implants, on either side of a maxillary arch. One hundred and ninety-two impressions were made using monophase VPS impression material. Their master casts were obtained and evaluated for the horizontal and vertical discrepancy. The casts were scanned using a model scanner. The distances between the two reference points were measured. The Straumann and SIC Invent implants showed no statistically significant differences (Mann-Whitney U test), regarding accuracy for both the open and closed tray impression techniques (P = 0.667 and P = 0.472). There were no significant differences for the parallel and non-parallel implants (P = 0.323 and P = 0.814), respectively, while the Osstem system showed statistically significant differences for both the open and closed tray impression techniques (P = 0.035) and between the parallel and non-parallel implants (P = 0.045). For the vertical discrepancies, significant differences were detected (chi-square test) between the open and closed tray impression techniques (P = 0.037). Within the limitations of this study, there were generally no significant differences between open and closed, although better results were obtained for the open tray techniques. On the use of the non-parallel implants, the open tray technique provided a better result than the closed tray technique.
- 19 February 2019
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 5 (1) , 1-10
Open AccessImplant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed tray techniques
The outcome of the evaluation of impression techniques accuracy may improve the selection criteria for an ideal technique. The aim was to evaluate the accuracy of the open and closed tray techniques for implant impressions, in a partially edentulous maxilla, replaced with a three-unit fixed partial denture, as well as to assess the effect of implants parallelism on accuracy. This is an experimental in vitro study to evaluate impressions accuracy of a simulated area restored with an implant retained FPD, using the open and closed tray implant impression techniques. The effect of implant position angulation, parallelism, and implant systems (Straumann, SIC Invent, Osstem) was also evaluated. Three custom-made acrylic resin test models were prepared with two parallel and two non-parallel implants, on either side of a maxillary arch. One hundred and ninety-two impressions were made using monophase VPS impression material. Their master casts were obtained and evaluated for the horizontal and vertical discrepancy. The casts were scanned using a model scanner. The distances between the two reference points were measured. The Straumann and SIC Invent implants showed no statistically significant differences (Mann-Whitney U test), regarding accuracy for both the open and closed tray impression techniques (P = 0.667 and P = 0.472). There were no significant differences for the parallel and non-parallel implants (P = 0.323 and P = 0.814), respectively, while the Osstem system showed statistically significant differences for both the open and closed tray impression techniques (P = 0.035) and between the parallel and non-parallel implants (P = 0.045). For the vertical discrepancies, significant differences were detected (chi-square test) between the open and closed tray impression techniques (P = 0.037). Within the limitations of this study, there were generally no significant differences between open and closed, although better results were obtained for the open tray techniques. On the use of the non-parallel implants, the open tray technique provided a better result than the closed tray technique.
- Open Access
- 1 January 2019
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 65 (C) , 344-348
Full-mouth rehabilitation of a patient with cleidocranial dysplasia using immediately loaded basal implant-supported fixed prostheses
Introduction: Cleidocranial dysplasia (CCD) is a rare congenital disease characterised by generalised skeletal and orofacial defects. The dental rehabilitation of patients with CCD is a case-sensitive procedure requiring a multidisciplinary approach. Presentation of case: A 24-year-old woman presented with the skeletal and oral manifestations of CCD, including multiple poorly erupted and impacted teeth. The patient was very depressed and rejected orthodontic treatment; therefore, we formulated a treatment plan involving extraction of all impacted and poorly erupted teeth under general anaesthesia, followed by fabrication and delivery of transitional complete dentures for cosmetic, functional, and psychological benefits. Three months later, 14 screw basal implants were inserted in the maxillary and mandibular jaws and subjected to immediate loading with fixed prostheses 3 days later. At the 3-year follow-up visit, the patient expressed satisfaction with the aesthetic and functional aspects of the prostheses and presented with excellent oral health. Discussion: The timing of diagnosis, patient’s age, willingness to undergo the planned treatment, and treatment duration are valuable considerations for establishing an appropriate treatment plan for the oral manifestations of CCD. Conclusion: To our knowledge, this is the first report on basal implant-based full-mouth rehabilitation in a patient with CCD. Basal implant-supported prostheses may be useful for patients with CCD who present with a limited bony foundation after tooth removal. The treatment requires lesser time than orthodontic treatment, eliminates the need for bone grafting, spares the patient from ill-fitting dentures, reduces the overall cost, and improves the quality of life. Highlights:
- 1 January 2019
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 65 (C) , 344-348
Open AccessFull-mouth rehabilitation of a patient with cleidocranial dysplasia using immediately loaded basal implant-supported fixed prostheses
Introduction: Cleidocranial dysplasia (CCD) is a rare congenital disease characterised by generalised skeletal and orofacial defects. The dental rehabilitation of patients with CCD is a case-sensitive procedure requiring a multidisciplinary approach. Presentation of case: A 24-year-old woman presented with the skeletal and oral manifestations of CCD, including multiple poorly erupted and impacted teeth. The patient was very depressed and rejected orthodontic treatment; therefore, we formulated a treatment plan involving extraction of all impacted and poorly erupted teeth under general anaesthesia, followed by fabrication and delivery of transitional complete dentures for cosmetic, functional, and psychological benefits. Three months later, 14 screw basal implants were inserted in the maxillary and mandibular jaws and subjected to immediate loading with fixed prostheses 3 days later. At the 3-year follow-up visit, the patient expressed satisfaction with the aesthetic and functional aspects of the prostheses and presented with excellent oral health. Discussion: The timing of diagnosis, patient’s age, willingness to undergo the planned treatment, and treatment duration are valuable considerations for establishing an appropriate treatment plan for the oral manifestations of CCD. Conclusion: To our knowledge, this is the first report on basal implant-based full-mouth rehabilitation in a patient with CCD. Basal implant-supported prostheses may be useful for patients with CCD who present with a limited bony foundation after tooth removal. The treatment requires lesser time than orthodontic treatment, eliminates the need for bone grafting, spares the patient from ill-fitting dentures, reduces the overall cost, and improves the quality of life. Highlights: