Nabil Kibriya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nabil Kibriya has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ben Stenberg
Freeman Hospital
1 shared publication D. Mullan
1 shared publicationD.W. Edwards
1 shared publication- Derek Manas
Freeman Hospital
1 shared publication - H.-U. Laasch
Academic Department of Gastrointestinal Radiology, South Manchester University Hospitals and University of Central Lancashire, UK
1 shared publication - Jen Jou Wong
Radiology Department, The Christie NHS Foundation Trust, Manchester, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 21 November 2018
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 42 (4) , 577-583
Percutaneous Irreversible Electroporation (IRE) of Hepatic Malignancy: A Bi-institutional Analysis of Safety and Outcomes
Irreversible electroporation (IRE) is a non-thermal ablative option in patients unsuitable for standard thermal ablation, due to its potential to preserve collagenous structures (vessels and ducts) and a reduced susceptibility to heat sink effects. In this series from two large tertiary referral hepatobiliary centres, we aim to assess the safety/outcomes of hepatic IRE.
- 21 November 2018
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 42 (4) , 577-583
Open AccessPercutaneous Irreversible Electroporation (IRE) of Hepatic Malignancy: A Bi-institutional Analysis of Safety and Outcomes
Irreversible electroporation (IRE) is a non-thermal ablative option in patients unsuitable for standard thermal ablation, due to its potential to preserve collagenous structures (vessels and ducts) and a reduced susceptibility to heat sink effects. In this series from two large tertiary referral hepatobiliary centres, we aim to assess the safety/outcomes of hepatic IRE.
- 1 November 2013
- Published by Elsevier in Clinical Radiology
- Vol. 68 (11) , 1128-1132
Disc-retained tubes for radiologically inserted gastrostomy (RIG): Not up to the job?
- 1 November 2013
- Published by Elsevier in Clinical Radiology
- Vol. 68 (11) , 1128-1132
Disc-retained tubes for radiologically inserted gastrostomy (RIG): Not up to the job?
- 26 January 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (4) , 1073-1078
French Sizing of Medical Devices is not Fit for Purpose
Purpose The purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology. Methods The labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity. Results A total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm. The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average. Conclusions Our results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed.
- 26 January 2013
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 36 (4) , 1073-1078
French Sizing of Medical Devices is not Fit for Purpose
Purpose The purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology. Methods The labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity. Results A total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm. The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average. Conclusions Our results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed.