Yapa Mudiyanselage Nuwan Dhananjaya Yapa Bandara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yapa Mudiyanselage Nuwan Dhananjaya Yapa Bandara has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Buddini Iroshika Karawdeniya
Department of Chemistry and Biochemistry
20 shared publications - Jason Rodger Dwyer
Department of Chemistry, University of Rhode Island, 140 Flagg Road, Kingston, Rhode Island 02881, United States
13 shared publications Jugal Saharia
Department of Engineering
10 shared publications- Min Jun Kim
Department of Mechanical Engineering Southern Methodist University Dallas Texas USA
10 shared publications - Patrick Kluth
Australian National University
7 shared publications - Shankar Dutt
Australian National University
6 shared publications
Latest Publications
- Open Access
- 26 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
IR Light Induces a Switch of Protein Translocation Direction from Electroosmotic to Electrophoretic in Quartz Nanopore Sensing
Single-molecule nanopore sensing provides a high-resolution, label-free platform to probe biomolecular dynamics and transport phenomena. Here, we investigate the biophysical response of proteins to low-powered (~160 mW) near-infrared (NIR) radiation (1050 nm) — a spectral region traditionally considered silent due to minimal absorption by water and biomolecules. Using nanopore sensors, we record single-molecule translocation events under varying electrolyte conditions. In control conditions with 2 M LiCl as the electrolyte, proteins translocate in the electroosmotic flow (EOF) direction. However, after 1050 nm NIR exposure, single-molecule recordings reveal a distinct switch in the transport mechanism, marked by the emergence of events in the electrophoretic (EPF) direction. This behavioral shift is observed across five distinct proteins, demonstrating a generalized phenomenon. Furthermore, in EPF-favoring electrolytes (KCl, NaCl, and CsCl), NIR illumination leads to a clear increase in current blockade depth (). Together, these direct single-molecule observations suggest that 1050 nm NIR radiation can potentially induce non-covalent protein aggregation, fundamentally altering transport behavior despite operating within an optically silent window.
- 26 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessIR Light Induces a Switch of Protein Translocation Direction from Electroosmotic to Electrophoretic in Quartz Nanopore Sensing
Single-molecule nanopore sensing provides a high-resolution, label-free platform to probe biomolecular dynamics and transport phenomena. Here, we investigate the biophysical response of proteins to low-powered (~160 mW) near-infrared (NIR) radiation (1050 nm) — a spectral region traditionally considered silent due to minimal absorption by water and biomolecules. Using nanopore sensors, we record single-molecule translocation events under varying electrolyte conditions. In control conditions with 2 M LiCl as the electrolyte, proteins translocate in the electroosmotic flow (EOF) direction. However, after 1050 nm NIR exposure, single-molecule recordings reveal a distinct switch in the transport mechanism, marked by the emergence of events in the electrophoretic (EPF) direction. This behavioral shift is observed across five distinct proteins, demonstrating a generalized phenomenon. Furthermore, in EPF-favoring electrolytes (KCl, NaCl, and CsCl), NIR illumination leads to a clear increase in current blockade depth (). Together, these direct single-molecule observations suggest that 1050 nm NIR radiation can potentially induce non-covalent protein aggregation, fundamentally altering transport behavior despite operating within an optically silent window.
- Open Access
- 26 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Effect of UV and Visible LED Light on the Translocation Behavior of DNA through Quartz Nanopipettes
DNA translocation through solid-state nanopores has been investigated extensively as a powerful platform for label-free and single-molecule sensing. The molecular-level sensing resolution of these sensors can be leveraged to further our understanding of the interactions between environmental factors and biomolecules. Biomolecules are known to have wavelength-dependent structural and functional susceptibilities, and here we sought to primarily investigate the effect of visible and UV light on the canonical DNA molecule. In this study, we investigate the effects of visible light on DNA molecules using quartz nanopipettes—low-noise solid-state nanopores with a tapered geometry. We systematically exposed DNA to various controlled wavelengths of light and characterized the induced structural changes. We monitored waveform features such as ionic current blockades, rectangularity, and aspect ratio (among others) as indicators of photon-induced damage or conformational changes and compared them with the control parameters. Waveform patterns arising from DNA translocation showed both wavelength- and exposure-time dependence. These variations were attributed to photoproduct formation or local strand instabilities, which alter DNA conformation and influence dynamics through the nanopore. These findings position nanopore-based analysis as a promising platform for studying light-illuminated structural changes in biomolecules.
- 26 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEffect of UV and Visible LED Light on the Translocation Behavior of DNA through Quartz Nanopipettes
DNA translocation through solid-state nanopores has been investigated extensively as a powerful platform for label-free and single-molecule sensing. The molecular-level sensing resolution of these sensors can be leveraged to further our understanding of the interactions between environmental factors and biomolecules. Biomolecules are known to have wavelength-dependent structural and functional susceptibilities, and here we sought to primarily investigate the effect of visible and UV light on the canonical DNA molecule. In this study, we investigate the effects of visible light on DNA molecules using quartz nanopipettes—low-noise solid-state nanopores with a tapered geometry. We systematically exposed DNA to various controlled wavelengths of light and characterized the induced structural changes. We monitored waveform features such as ionic current blockades, rectangularity, and aspect ratio (among others) as indicators of photon-induced damage or conformational changes and compared them with the control parameters. Waveform patterns arising from DNA translocation showed both wavelength- and exposure-time dependence. These variations were attributed to photoproduct formation or local strand instabilities, which alter DNA conformation and influence dynamics through the nanopore. These findings position nanopore-based analysis as a promising platform for studying light-illuminated structural changes in biomolecules.
- Open Access
- 26 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Gateway to Data Visualization and Analysis in Solid-State Nanopores
Solid-state nanopores are a class of single-molecule sensors with a growing footprint in molecular fingerprinting. Given the unique nature of experiments, data extraction, visualization, and interpretation are often carried out using customized software: an unacknowledged legacy barrier that stifles overall productivity and hinders entry for early-career researchers. With concerted efforts to democratize the solid-state nanopore technology and make it more accessible to a broader audience, there is a need to create a roadmap for data handling and processing associated with solid-state nanopores. In this work, we present a suite of apps and methods engineered to transition from raw ionic current traces to actionable data metrics. Our platform provides an integrated framework for the rigorous characterization of translocation events through the HyperXtract 2.0 app (HX2.0), which extracts over 50 distinct waveform features per event. To ensure data integrity, the quality of the nanopore is quantified using a suite of health parameters that underpin the biophysical reliability of the resulting waveforms. To facilitate multi-dimensional analysis, the software integrates specialized visualization modules for scatter plots, histograms, and non-linear curve fitting. It also includes high-density contour and heat maps (with clustering and denoising options), which are essential for resolving overlapping molecular populations that standard 1D plots might obscure. Collectively, bivariate contouring of waveform features from HX introduces a new path for the construction of QR-like molecular fingerprinting architecture. These apps considerably accelerate the data treatment step, empowering rapid and confident post-experiment decision-making.
- 26 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessGateway to Data Visualization and Analysis in Solid-State Nanopores
Solid-state nanopores are a class of single-molecule sensors with a growing footprint in molecular fingerprinting. Given the unique nature of experiments, data extraction, visualization, and interpretation are often carried out using customized software: an unacknowledged legacy barrier that stifles overall productivity and hinders entry for early-career researchers. With concerted efforts to democratize the solid-state nanopore technology and make it more accessible to a broader audience, there is a need to create a roadmap for data handling and processing associated with solid-state nanopores. In this work, we present a suite of apps and methods engineered to transition from raw ionic current traces to actionable data metrics. Our platform provides an integrated framework for the rigorous characterization of translocation events through the HyperXtract 2.0 app (HX2.0), which extracts over 50 distinct waveform features per event. To ensure data integrity, the quality of the nanopore is quantified using a suite of health parameters that underpin the biophysical reliability of the resulting waveforms. To facilitate multi-dimensional analysis, the software integrates specialized visualization modules for scatter plots, histograms, and non-linear curve fitting. It also includes high-density contour and heat maps (with clustering and denoising options), which are essential for resolving overlapping molecular populations that standard 1D plots might obscure. Collectively, bivariate contouring of waveform features from HX introduces a new path for the construction of QR-like molecular fingerprinting architecture. These apps considerably accelerate the data treatment step, empowering rapid and confident post-experiment decision-making.
- Open Access
- 16 August 2026
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (5) , 1586-1596
Investigation of Shielding Strategies to Mitigate Noise in Nanopore Recordings
Shielding against electromagnetic interference (EMI), vibration, and mechanical noise is crucial for the reliable performance of sensitive electronics, especially in high-disturbance environments. While Faraday cages are ubiquitously used for this purpose, they are often implemented simply as metal boxes enclosing the measurement system without accounting for critical design factors such as skin depth. In this study, we investigated a range of factors to understand noise sources, coupling pathways, and systematic approaches for effective shielding beyond the common metal box approach, including the evaluation of power-line quality, grounding strategies for the Faraday cage, connectivity solutions to maintain Faraday cage integrity, and the relative positioning of the components in the measurement setup. Our findings have rendered the noise in the current measurements comparable to that of biological nanopores in the more ubiquitous 10 kHz lowpass filter setting. This low-noise floor has allowed us to detect DNA translocations under challenging low-electrolyte conditions (e.g., 10 mM KCl) using the highest lowpass filter setting of the Axopatch 200B (i.e., 100 kHz). Moreover, with necessary modifications, these findings were extended to the megahertz-level bandwidth regime, where sampling rates up to 10 MHz yielded extractable events with unfiltered traces. Although our findings broadly cater to solid-state nanopore (SSN) sensing, their applicability should extend beyond SSNs to other sensitive electronic systems.
- 16 August 2026
- Published by American Chemical Society (ACS) in ACS Measurement Science Au
- Vol. 6 (5) , 1586-1596
Open AccessInvestigation of Shielding Strategies to Mitigate Noise in Nanopore Recordings
Shielding against electromagnetic interference (EMI), vibration, and mechanical noise is crucial for the reliable performance of sensitive electronics, especially in high-disturbance environments. While Faraday cages are ubiquitously used for this purpose, they are often implemented simply as metal boxes enclosing the measurement system without accounting for critical design factors such as skin depth. In this study, we investigated a range of factors to understand noise sources, coupling pathways, and systematic approaches for effective shielding beyond the common metal box approach, including the evaluation of power-line quality, grounding strategies for the Faraday cage, connectivity solutions to maintain Faraday cage integrity, and the relative positioning of the components in the measurement setup. Our findings have rendered the noise in the current measurements comparable to that of biological nanopores in the more ubiquitous 10 kHz lowpass filter setting. This low-noise floor has allowed us to detect DNA translocations under challenging low-electrolyte conditions (e.g., 10 mM KCl) using the highest lowpass filter setting of the Axopatch 200B (i.e., 100 kHz). Moreover, with necessary modifications, these findings were extended to the megahertz-level bandwidth regime, where sampling rates up to 10 MHz yielded extractable events with unfiltered traces. Although our findings broadly cater to solid-state nanopore (SSN) sensing, their applicability should extend beyond SSNs to other sensitive electronic systems.
- Open Access
- 30 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Off-the-Shelf Coding-Free Low-Cost Approach for Temperature Control of Nanopore Experiments
Temperature significantly influences the kinetics and thermodynamics of molecular transport within solid-state nanopores with an inextricable link to translocation velocities, signal amplitudes, and event capture rates. However, dynamic thermal regulation is rarely implemented in solid-state nanopore systems largely due to high system costs (for both hardware and software) and exposure to electromagnetic interference due to breaching of the Faraday cage system. To address these challenges, a fully off-the-shelf, coding-free, and cost-effective closed-loop fluidic system was developed, enabling precise temperature control (±0.2°C) across a broad operational range from ~5 °C to 90 °C. The system employs a localized fluidic circulation loop powered by an external pump, a thermoelectric cooler, a heating block, and a relay operated via temperature logic, thereby eliminating the need for specialized microcontroller programming and achieving stable thermal conditions within a custom-insulated, nested Faraday cage. Electrical noise analysis demonstrates that the system maintains adequate noise shielding: with 100 kHz lowpass filtering of the Axopatch 200B, the root-mean-square current (Irms) increases by only ~11% (from ~28 pA to ~32 pA). The platform's effectiveness is further validated through single-molecule translocation experiments of the protein apo-transferrin in a 4 M LiCl electrolyte. Developed with a total hardware investment of under $400, this robust, plug-and-play methodology broadens access to temperature-controlled nanopore experiments and supports biophysical characterization of macromolecular conformation and transport kinetics.
- 30 July 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessOff-the-Shelf Coding-Free Low-Cost Approach for Temperature Control of Nanopore Experiments
Temperature significantly influences the kinetics and thermodynamics of molecular transport within solid-state nanopores with an inextricable link to translocation velocities, signal amplitudes, and event capture rates. However, dynamic thermal regulation is rarely implemented in solid-state nanopore systems largely due to high system costs (for both hardware and software) and exposure to electromagnetic interference due to breaching of the Faraday cage system. To address these challenges, a fully off-the-shelf, coding-free, and cost-effective closed-loop fluidic system was developed, enabling precise temperature control (±0.2°C) across a broad operational range from ~5 °C to 90 °C. The system employs a localized fluidic circulation loop powered by an external pump, a thermoelectric cooler, a heating block, and a relay operated via temperature logic, thereby eliminating the need for specialized microcontroller programming and achieving stable thermal conditions within a custom-insulated, nested Faraday cage. Electrical noise analysis demonstrates that the system maintains adequate noise shielding: with 100 kHz lowpass filtering of the Axopatch 200B, the root-mean-square current (Irms) increases by only ~11% (from ~28 pA to ~32 pA). The platform's effectiveness is further validated through single-molecule translocation experiments of the protein apo-transferrin in a 4 M LiCl electrolyte. Developed with a total hardware investment of under $400, this robust, plug-and-play methodology broadens access to temperature-controlled nanopore experiments and supports biophysical characterization of macromolecular conformation and transport kinetics.
- Open Access
- 18 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Leveraging the Stochastic Nature of Solid-State Nanopore Sensing for Random Number Generation: A Step Towards Cybersecurity Engineering
Unpredictability and entropy are key factors governing the success of cryptographic security, and true random numbers play a pivotal role in this space. While software-driven random numbers are easy and efficient to generate, their deterministic nature creates a vulnerability that could compromise the gate, barring entry to a sensitive system. Here, we propose using measurement randomness arising from physical and chemical aspects of transport (Layer 1), hardware characteristics (Layer 2), event features and extraction (Layer 3; facilitated by the HyperXtract 2.0), and cryptographic whitening via the secure hash algorithm (SHA-256; Layer 4) to create a high-entropy TRNG system. We demonstrate a host of unique experimental conditions (e.g., electrolyte chemistry, applied voltage, analyte type, transport direction, temperature, and amplifier type) across these four layers to generate ~480,000 256-bit long keys with 100% uniqueness in a Pearson-correlation-based statistical entropy harvesting method and most other methods reporting >99.9% unique keys in most instances. Furthermore, the randomness of these keys was evaluated using the NIST SP800-22b statistical test suite and yielded a success rate of ~99% at a 1% significance level. This study thus showcases the utility of solid-state nanopore sensing for generating high-entropy TRNGs and the potential as a robust, non-deterministic source for nextgeneration cybersecurity engineering.
- 18 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessLeveraging the Stochastic Nature of Solid-State Nanopore Sensing for Random Number Generation: A Step Towards Cybersecurity Engineering
Unpredictability and entropy are key factors governing the success of cryptographic security, and true random numbers play a pivotal role in this space. While software-driven random numbers are easy and efficient to generate, their deterministic nature creates a vulnerability that could compromise the gate, barring entry to a sensitive system. Here, we propose using measurement randomness arising from physical and chemical aspects of transport (Layer 1), hardware characteristics (Layer 2), event features and extraction (Layer 3; facilitated by the HyperXtract 2.0), and cryptographic whitening via the secure hash algorithm (SHA-256; Layer 4) to create a high-entropy TRNG system. We demonstrate a host of unique experimental conditions (e.g., electrolyte chemistry, applied voltage, analyte type, transport direction, temperature, and amplifier type) across these four layers to generate ~480,000 256-bit long keys with 100% uniqueness in a Pearson-correlation-based statistical entropy harvesting method and most other methods reporting >99.9% unique keys in most instances. Furthermore, the randomness of these keys was evaluated using the NIST SP800-22b statistical test suite and yielded a success rate of ~99% at a 1% significance level. This study thus showcases the utility of solid-state nanopore sensing for generating high-entropy TRNGs and the potential as a robust, non-deterministic source for nextgeneration cybersecurity engineering.
- Open Access
- 16 March 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Gateway to Data Visualization and Analysis in Solid-State Nanopores
Solid-state nanopores are a class of single-molecule sensors with a growing footprint in molecular fingerprinting. Given the unique nature of experiments, data extraction, visualization, and interpretation are often carried out using customized software: an unacknowledged legacy barrier that stifles overall productivity and hinders entry for early-career researchers. With concerted efforts to democratize the solid-state nanopore technology and make it more accessible to a broader audience, there is a need to create a roadmap for data handling and processing associated with solid-state nanopores. In this work, we present a suite of apps and methods engineered to transition from raw ionic current traces to actionable data metrics. Our platform provides an integrated framework for the rigorous characterization of translocation events through the HyperXtract 2.0 app (HX2.0), which extracts over 50 distinct waveform features per event. To ensure data integrity, the quality of the nanopore is quantified using a suite of health parameters that underpin the biophysical reliability of the resulting waveforms. To facilitate multi-dimensional analysis, the software integrates specialized visualization modules for scatter plots, histograms, and non-linear curve fitting. It also includes high-density contour and heat maps (with clustering and denoising options), which are essential for resolving overlapping molecular populations that standard 1D plots might obscure. Collectively, bivariate contouring of waveform features from HX introduces a new path for the construction of QR-like molecular fingerprinting architecture. These apps considerably accelerate the data treatment step, empowering rapid and confident post-experiment decision-making.
- 16 March 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessGateway to Data Visualization and Analysis in Solid-State Nanopores
Solid-state nanopores are a class of single-molecule sensors with a growing footprint in molecular fingerprinting. Given the unique nature of experiments, data extraction, visualization, and interpretation are often carried out using customized software: an unacknowledged legacy barrier that stifles overall productivity and hinders entry for early-career researchers. With concerted efforts to democratize the solid-state nanopore technology and make it more accessible to a broader audience, there is a need to create a roadmap for data handling and processing associated with solid-state nanopores. In this work, we present a suite of apps and methods engineered to transition from raw ionic current traces to actionable data metrics. Our platform provides an integrated framework for the rigorous characterization of translocation events through the HyperXtract 2.0 app (HX2.0), which extracts over 50 distinct waveform features per event. To ensure data integrity, the quality of the nanopore is quantified using a suite of health parameters that underpin the biophysical reliability of the resulting waveforms. To facilitate multi-dimensional analysis, the software integrates specialized visualization modules for scatter plots, histograms, and non-linear curve fitting. It also includes high-density contour and heat maps (with clustering and denoising options), which are essential for resolving overlapping molecular populations that standard 1D plots might obscure. Collectively, bivariate contouring of waveform features from HX introduces a new path for the construction of QR-like molecular fingerprinting architecture. These apps considerably accelerate the data treatment step, empowering rapid and confident post-experiment decision-making.
- Open Access
- 14 January 2026
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 54 (2)
Solid-state nanopore sensing reveals conformational changes induced by a mutation in a neuron-specific tRNAArg
We demonstrate that solid-state nanopore sensing is a powerful single-molecule method for analyzing RNA conformational ensembles. As a model, we employed n-Tr20, a neuron-specific cytoplasmic tRNA$_{\mathrm{UCU}}^{\mathrm{Arg}}$, whose C50U mutation is associated with neurodegeneration in C57BL/6J mice. Maturation of the n-Tr20$^{\mathrm{C50U}}$ precursor is impaired as the mutation stabilizes a conformational ensemble different from the wild type. To gain insights into how this mutation engenders structural differences, we used solid-state nanopore sensing for the real-time identification of metastable conformers that are not easily observable by ensemble methods. Ion-current traces recorded using an 8 nm nanopore revealed broad contours of the conformational landscape of n-Tr20/n-Tr20$^\mathrm{C50U}$ $\pm$ Mg$^{2+}$. Additionally, cryo-electron microscopy analysis and small-angle X-ray scattering studies revealed structural plasticity consistent with the nanopore-sensing data. Since dynamics undergird RNA (dys)function in cellular physiology and pathology, nanopore sensing to determine RNA conformational sampling is a valuable addition to the growing RNA structural analysis toolkit.- 14 January 2026
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 54 (2)
Open AccessSolid-state nanopore sensing reveals conformational changes induced by a mutation in a neuron-specific tRNAArg
We demonstrate that solid-state nanopore sensing is a powerful single-molecule method for analyzing RNA conformational ensembles. As a model, we employed n-Tr20, a neuron-specific cytoplasmic tRNA$_{\mathrm{UCU}}^{\mathrm{Arg}}$, whose C50U mutation is associated with neurodegeneration in C57BL/6J mice. Maturation of the n-Tr20$^{\mathrm{C50U}}$ precursor is impaired as the mutation stabilizes a conformational ensemble different from the wild type. To gain insights into how this mutation engenders structural differences, we used solid-state nanopore sensing for the real-time identification of metastable conformers that are not easily observable by ensemble methods. Ion-current traces recorded using an 8 nm nanopore revealed broad contours of the conformational landscape of n-Tr20/n-Tr20$^\mathrm{C50U}$ $\pm$ Mg$^{2+}$. Additionally, cryo-electron microscopy analysis and small-angle X-ray scattering studies revealed structural plasticity consistent with the nanopore-sensing data. Since dynamics undergird RNA (dys)function in cellular physiology and pathology, nanopore sensing to determine RNA conformational sampling is a valuable addition to the growing RNA structural analysis toolkit. - Open Access
- 31 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Investigation of Shielding Strategies to Mitigate Noise in Nanopore Recordings
Shielding against electromagnetic interference (EMI), vibration, and mechanical noise is crucial for reliable performance of sensitive electronics, especially in high-disturbance environments. While Faraday cages are ubiquitously used for this purpose, they are often implemented simply as metal boxes enclosing the measurement system, without accounting for critical design factors such as skin depth. In this study, we have investigated a host of factors to understand noise origins, noise coupling pathways, and systematic treatment for effective shielding against them beyond the common metal box treatment. To accomplish this, we pursued the construction of a nested Faraday system conducive for low-noise data acquisition, investigating powerline quality, grounding strategies for the Faraday cage, connectivity solutions for maintaining Faraday cage integrity, and relative positioning of the components in the measurement setup. Our findings have rendered noise in current measurements to be in the vicinity of biological nanopores. For example, with 100 mM KCl, the RMS current (Irms) at 10 kHz was found to be 4.1±0.1 pA, while that of α-hemolysin is reported to be ~2-3 pA. This low noise floor has allowed us to detect translocation of DNA under challenging low electrolyte conditions (i.e., 10 mM KCl) using the highest lowpass filter setting of the Axopatch 200B (i.e., 100 kHz). Moreover, with necessary modifications, these findings were extended to the MHz-level bandwidth regime, where events up to 10 MHz of sampling rate were observed with unfiltered traces. Although our findings broadly cater to solid-state nanopore (SSN) sensing, their applicability should extend beyond SSNs into other sensitive electronic systems.
- 31 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessInvestigation of Shielding Strategies to Mitigate Noise in Nanopore Recordings
Shielding against electromagnetic interference (EMI), vibration, and mechanical noise is crucial for reliable performance of sensitive electronics, especially in high-disturbance environments. While Faraday cages are ubiquitously used for this purpose, they are often implemented simply as metal boxes enclosing the measurement system, without accounting for critical design factors such as skin depth. In this study, we have investigated a host of factors to understand noise origins, noise coupling pathways, and systematic treatment for effective shielding against them beyond the common metal box treatment. To accomplish this, we pursued the construction of a nested Faraday system conducive for low-noise data acquisition, investigating powerline quality, grounding strategies for the Faraday cage, connectivity solutions for maintaining Faraday cage integrity, and relative positioning of the components in the measurement setup. Our findings have rendered noise in current measurements to be in the vicinity of biological nanopores. For example, with 100 mM KCl, the RMS current (Irms) at 10 kHz was found to be 4.1±0.1 pA, while that of α-hemolysin is reported to be ~2-3 pA. This low noise floor has allowed us to detect translocation of DNA under challenging low electrolyte conditions (i.e., 10 mM KCl) using the highest lowpass filter setting of the Axopatch 200B (i.e., 100 kHz). Moreover, with necessary modifications, these findings were extended to the MHz-level bandwidth regime, where events up to 10 MHz of sampling rate were observed with unfiltered traces. Although our findings broadly cater to solid-state nanopore (SSN) sensing, their applicability should extend beyond SSNs into other sensitive electronic systems.
- 24 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
HyperXtract: Strategic Platform for Optimizing High-Bandwidth Nanopore Data Extraction Performance
High-bandwidth amplifiers that offer measurement capabilities on the submicrosecond scale to resonate with short-lived events have recently gained tremendous traction in solid-state nanopore (SSN) sensing. High acquisition rate data collection is a hallmark of such measurements, leading to oversized files. Such experimental needs warrant high-performance analysis platforms that can analyze large files in a reasonable time frame. This study introduces a new platform (coined HyperXtract, HX) that supersedes the capabilities of other readily available SSN analysis platforms. HX is benchmarked against its predecessor, NanoPlex (NP), which has demonstrated superior performance characteristics against other readily available SSN event extraction platforms. For example, a 1000 s-long file acquired at 40 MHz only takes 45× more time for the event extraction. The salient features underpinning the superior performance metrics of HX include using MEX functions, memory mapping, preallocation of storage vectors, optimizing standard functions, and event-free baseline segment isolation to determine the event detection coefficient. The ability to extract events <5% of the acquisition time places HX to assist with near real-time decision-making in challenging high-bandwidth experiments. These code optimizations allow HX to outperform NP even while using less powerful computers.
- 24 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
HyperXtract: Strategic Platform for Optimizing High-Bandwidth Nanopore Data Extraction Performance
High-bandwidth amplifiers that offer measurement capabilities on the submicrosecond scale to resonate with short-lived events have recently gained tremendous traction in solid-state nanopore (SSN) sensing. High acquisition rate data collection is a hallmark of such measurements, leading to oversized files. Such experimental needs warrant high-performance analysis platforms that can analyze large files in a reasonable time frame. This study introduces a new platform (coined HyperXtract, HX) that supersedes the capabilities of other readily available SSN analysis platforms. HX is benchmarked against its predecessor, NanoPlex (NP), which has demonstrated superior performance characteristics against other readily available SSN event extraction platforms. For example, a 1000 s-long file acquired at 40 MHz only takes 45× more time for the event extraction. The salient features underpinning the superior performance metrics of HX include using MEX functions, memory mapping, preallocation of storage vectors, optimizing standard functions, and event-free baseline segment isolation to determine the event detection coefficient. The ability to extract events <5% of the acquisition time places HX to assist with near real-time decision-making in challenging high-bandwidth experiments. These code optimizations allow HX to outperform NP even while using less powerful computers.