Junqi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Junqi Wang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Robert Nidetz
Department of Mechanical Engineering, University of Michigan, Ann Arbor, USA
5 shared publications - Edward. T. Zellers
Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
3 shared publications - Sanketh Buggaveeti
Infinera Corporation, 140 Caspian Court, Sunnyvale, CA, 94089
3 shared publications Changhua Zhan
Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI 48109, USA
2 shared publicationsEdward T. Zellers
2 shared publicationsNicolas Nuñovero
Department of Environmental Health Sciences , University of Michigan , Ann Arbor , Michigan 48109 , United States
2 shared publications
Latest Publications
- 6 March 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (7) , 4747-4754
Belt-Mounted Micro-Gas-Chromatograph Prototype for Determining Personal Exposures to Volatile-Organic-Compound Mixture Components
We describe a belt-mountable prototype instrument containing a gas chromatographic microsystem (µGC) and demonstrate its capability for near-real-time recognition and quantification of volatile organic compounds (VOC) in moderately complex mixtures at concentrations encountered in industrial workplace environments. The µGC comprises three discrete, Si/Pyrex microfabricated chips: a dual-adsorbent µpreconcentrator/focuser for VOC capture and injection; a wall-coated μcolumn with thin-metal heaters and temperature sensors for temperature programmed separations; and an array of four µchemiresistors with thiolate-monolayer protected Au nanoparticle interface films for detection and recognition/discrimination. The battery-powered µGC prototype (20×15×9 cm, ~2.1 kg sans battery) has on-board microcontrollers and can autonomously analyze the components of a given VOC mixture several times per hour. Calibration curves bracketing the Threshold Limit Value® (TLV) of each VOC yielded detection limits of 16-600 parts-per-billion for air samples of 5-10 mL; well below respective TLVs. A 2:1 injection split improved the resolution of early eluting compounds by up to 63%. Responses and response patterns were stable for five days. Use of retention-time windows facilitated the chemometric recognition and discrimination of the components of a 21-VOC mixture sampled and analyzed in 3.5 min. Results from a “mock” field test, in which personal exposures to time-varying concentrations of a mixture of five VOCs were measured autonomously, agreed closely with those from a reference GC. Thus, reliable near-real-time determinations of worker exposures to multiple VOCs with this wearable µGC prototype appear feasible.
- 6 March 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (7) , 4747-4754
Belt-Mounted Micro-Gas-Chromatograph Prototype for Determining Personal Exposures to Volatile-Organic-Compound Mixture Components
We describe a belt-mountable prototype instrument containing a gas chromatographic microsystem (µGC) and demonstrate its capability for near-real-time recognition and quantification of volatile organic compounds (VOC) in moderately complex mixtures at concentrations encountered in industrial workplace environments. The µGC comprises three discrete, Si/Pyrex microfabricated chips: a dual-adsorbent µpreconcentrator/focuser for VOC capture and injection; a wall-coated μcolumn with thin-metal heaters and temperature sensors for temperature programmed separations; and an array of four µchemiresistors with thiolate-monolayer protected Au nanoparticle interface films for detection and recognition/discrimination. The battery-powered µGC prototype (20×15×9 cm, ~2.1 kg sans battery) has on-board microcontrollers and can autonomously analyze the components of a given VOC mixture several times per hour. Calibration curves bracketing the Threshold Limit Value® (TLV) of each VOC yielded detection limits of 16-600 parts-per-billion for air samples of 5-10 mL; well below respective TLVs. A 2:1 injection split improved the resolution of early eluting compounds by up to 63%. Responses and response patterns were stable for five days. Use of retention-time windows facilitated the chemometric recognition and discrimination of the components of a 21-VOC mixture sampled and analyzed in 3.5 min. Results from a “mock” field test, in which personal exposures to time-varying concentrations of a mixture of five VOCs were measured autonomously, agreed closely with those from a reference GC. Thus, reliable near-real-time determinations of worker exposures to multiple VOCs with this wearable µGC prototype appear feasible.
- Open Access
- 9 April 2018
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 4 (1) , 17101
Compact prototype microfabricated gas chromatographic analyzer for autonomous determinations of VOC mixtures at typical workplace concentrations
This report concerns a benchtop prototype instrument containing a gas chromatographic microanalytical system (μGC) designed for the selective determination of multiple airborne volatile organic compounds (VOCs) at concentrations in the vicinity of recommended occupational exposure limits. The core microsystem consists of a set of discrete Si-microfabricated devices: a dual-cavity, adsorbent-packed micro-preconcentrator-focuser (μPCF) chip that quantitatively captures and thermally desorbs/injects VOCs with vapor pressures between ~0.03 and 13 kPa; tandem micro-column (μcolumn) chips with cross-linked PDMS wall-coated stationary phases capable of temperature-programmed separations; and an integrated array of five μchemiresistors (μCR) coated with different thiolate-monolayer protected gold nanoparticle (MPN) interface films that quantifies and further differentiates among the analytes by virtue of the response patterns generated. Other key components include a pre-trap for low-volatility interferences, a split-flow injection valve, and an onboard He carrier–gas canister. The assembled unit measures 19×30×14 cm, weighs ~3.5 kg, operates on AC power, and is laptop/LabVIEW controlled. Component- and system-level tests of performance demonstrated injection bandwidths <1 s, a μcolumn capacity of ≥8 μg injected mass, linear calibration curves, no humidity effects, excellent medium-term (that is, 1 week) reproducibility, autonomous operation for 8 h, detection limits below Threshold Limit Values (TLV) for 10 mL air samples collected in 1 min, and response patterns that enhanced vapor recognition. The determination of a 17-VOC mixture in the presence of seven interferences was performed in 4 min. Results augur well for adapting the microsystem to an all-MEMS wearable μGC currently under parallel development.
- 9 April 2018
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 4 (1) , 17101
Open AccessCompact prototype microfabricated gas chromatographic analyzer for autonomous determinations of VOC mixtures at typical workplace concentrations
This report concerns a benchtop prototype instrument containing a gas chromatographic microanalytical system (μGC) designed for the selective determination of multiple airborne volatile organic compounds (VOCs) at concentrations in the vicinity of recommended occupational exposure limits. The core microsystem consists of a set of discrete Si-microfabricated devices: a dual-cavity, adsorbent-packed micro-preconcentrator-focuser (μPCF) chip that quantitatively captures and thermally desorbs/injects VOCs with vapor pressures between ~0.03 and 13 kPa; tandem micro-column (μcolumn) chips with cross-linked PDMS wall-coated stationary phases capable of temperature-programmed separations; and an integrated array of five μchemiresistors (μCR) coated with different thiolate-monolayer protected gold nanoparticle (MPN) interface films that quantifies and further differentiates among the analytes by virtue of the response patterns generated. Other key components include a pre-trap for low-volatility interferences, a split-flow injection valve, and an onboard He carrier–gas canister. The assembled unit measures 19×30×14 cm, weighs ~3.5 kg, operates on AC power, and is laptop/LabVIEW controlled. Component- and system-level tests of performance demonstrated injection bandwidths <1 s, a μcolumn capacity of ≥8 μg injected mass, linear calibration curves, no humidity effects, excellent medium-term (that is, 1 week) reproducibility, autonomous operation for 8 h, detection limits below Threshold Limit Values (TLV) for 10 mL air samples collected in 1 min, and response patterns that enhanced vapor recognition. The determination of a 17-VOC mixture in the presence of seven interferences was performed in 4 min. Results augur well for adapting the microsystem to an all-MEMS wearable μGC currently under parallel development.
- 1 January 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 254, 561-572
A zone-heated gas chromatographic microcolumn: Energy efficiency
- 1 January 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 254, 561-572
A zone-heated gas chromatographic microcolumn: Energy efficiency
- Open Access
- 16 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 633
Microscale Gas Chromatography with Microsensor Array Detection: Challenges and Prospects
The capability to analyze complex mixtures of airborne volatile organic compounds (VOCs) at low concentrations; in situ; has implications for environmental monitoring; worker exposure assessment; biomedical diagnostics; and population security. Since standalone microsensor arrays lack this capability; upstream separation of mixture components; often preceded by preconcentration; is required. Although significant advances have been made via MEMS technologies in the development of microscale gas chromatographic (μGC) systems; many challenges remain. This presentation will review selected aspects of the state-of-the-art in μGC for VOC mixture analysis. Here; we emphasize our progress toward a wearable μGC prototype.
- 16 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 633
Open AccessMicroscale Gas Chromatography with Microsensor Array Detection: Challenges and Prospects
The capability to analyze complex mixtures of airborne volatile organic compounds (VOCs) at low concentrations; in situ; has implications for environmental monitoring; worker exposure assessment; biomedical diagnostics; and population security. Since standalone microsensor arrays lack this capability; upstream separation of mixture components; often preceded by preconcentration; is required. Although significant advances have been made via MEMS technologies in the development of microscale gas chromatographic (μGC) systems; many challenges remain. This presentation will review selected aspects of the state-of-the-art in μGC for VOC mixture analysis. Here; we emphasize our progress toward a wearable μGC prototype.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 668-671
Micro vapor extractor for on-site determinations of volatile organic compounds in water and biofluids
A passive, membrane-mediated, microfabricated vapor extractor (μVE) chip for collecting volatile organic compounds (VOC) from water and biofluids is presented. Its performance when interfaced to a micro-scale gas chromatograph (μGC) prototype is demonstrated. A mixture of 4 VOCs spiked into synthetic urine at ppm concentrations was extracted by the 2.8×2.3 cm μVE chip from a 700-μL sample in 3.5 min, and then preconcentrated, injected, separated and detected by μGC in ~80 sec with detection limits as low as 660 ppb. Response patterns provided by the μGC sensor-array detector facilitated VOC identification. The hybrid μVEμGC microsystem may eventually permit rapid field/clinical analyses of water contaminants and urinary biomarkers of exposure and disease.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 668-671
Micro vapor extractor for on-site determinations of volatile organic compounds in water and biofluids
A passive, membrane-mediated, microfabricated vapor extractor (μVE) chip for collecting volatile organic compounds (VOC) from water and biofluids is presented. Its performance when interfaced to a micro-scale gas chromatograph (μGC) prototype is demonstrated. A mixture of 4 VOCs spiked into synthetic urine at ppm concentrations was extracted by the 2.8×2.3 cm μVE chip from a 700-μL sample in 3.5 min, and then preconcentrated, injected, separated and detected by μGC in ~80 sec with detection limits as low as 660 ppb. Response patterns provided by the μGC sensor-array detector facilitated VOC identification. The hybrid μVEμGC microsystem may eventually permit rapid field/clinical analyses of water contaminants and urinary biomarkers of exposure and disease.
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 1398-1401
A Wearable MEMS Gas Chromatograph for Multi-Vapor Determinations
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 1398-1401
Open AccessA Wearable MEMS Gas Chromatograph for Multi-Vapor Determinations
- 28 June 2012
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 10 (31) , 6271-6274
A new N-imidazolyl-1,8-naphthalimide based fluorescence sensor for fluoride detection
A chemosensor is reported with high sensitivity and selectivity for detection of fluoride anion. The recognition mechanism is attributed to a fluoride-triggered disruption of the hydrogen bond between imidazole and naphthalimide moieties, resulting in a noncoplanar geometry with low fluorescence.
- 28 June 2012
- Published by Royal Society of Chemistry (RSC) in Organic & Biomolecular Chemistry
- Vol. 10 (31) , 6271-6274
A new N-imidazolyl-1,8-naphthalimide based fluorescence sensor for fluoride detection
A chemosensor is reported with high sensitivity and selectivity for detection of fluoride anion. The recognition mechanism is attributed to a fluoride-triggered disruption of the hydrogen bond between imidazole and naphthalimide moieties, resulting in a noncoplanar geometry with low fluorescence.