JWJunqi Wang

Junqi Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Junqi Wang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Belt-Mounted Micro-Gas-Chromatograph Prototype for Determining Personal Exposures to Volatile-Organic-Compound Mixture Components

    by Junqi Wang, Nicolas Nuñovero, Robert Nidetz, Seth J. Peterson, Bryan M. Brookover, William H. Steinecker, Edward T. Zellers

    We describe a belt-mountable prototype instrument containing a gas chromatographic microsystem (µGC) and demonstrate its capability for near-real-time recognition and quantification of volatile organic compounds (VOC) in moderately complex mixtures at concentrations encountered in industrial workplace environments. The µGC comprises three discrete, Si/Pyrex microfabricated chips: a dual-adsorbent µpreconcentrator/focuser for VOC capture and injection; a wall-coated μcolumn with thin-metal heaters and temperature sensors for temperature programmed separations; and an array of four µchemiresistors with thiolate-monolayer protected Au nanoparticle interface films for detection and recognition/discrimination. The battery-powered µGC prototype (20×15×9 cm, ~2.1 kg sans battery) has on-board microcontrollers and can autonomously analyze the components of a given VOC mixture several times per hour. Calibration curves bracketing the Threshold Limit Value® (TLV) of each VOC yielded detection limits of 16-600 parts-per-billion for air samples of 5-10 mL; well below respective TLVs. A 2:1 injection split improved the resolution of early eluting compounds by up to 63%. Responses and response patterns were stable for five days. Use of retention-time windows facilitated the chemometric recognition and discrimination of the components of a 21-VOC mixture sampled and analyzed in 3.5 min. Results from a “mock” field test, in which personal exposures to time-varying concentrations of a mixture of five VOCs were measured autonomously, agreed closely with those from a reference GC. Thus, reliable near-real-time determinations of worker exposures to multiple VOCs with this wearable µGC prototype appear feasible.


  • Open Access

    Compact prototype microfabricated gas chromatographic analyzer for autonomous determinations of VOC mixtures at typical workplace concentrations

    by Junqi Wang, Jonathan Bryant-Genevier, Nicolas Nuñovero, Chengyi Zhang, Bruce Kraay, Changhua Zhan, Kee Scholten, Robert Nidetz, Sanketh Buggaveeti, Edward T. Zellers

    This report concerns a benchtop prototype instrument containing a gas chromatographic microanalytical system (μGC) designed for the selective determination of multiple airborne volatile organic compounds (VOCs) at concentrations in the vicinity of recommended occupational exposure limits. The core microsystem consists of a set of discrete Si-microfabricated devices: a dual-cavity, adsorbent-packed micro-preconcentrator-focuser (μPCF) chip that quantitatively captures and thermally desorbs/injects VOCs with vapor pressures between ~0.03 and 13 kPa; tandem micro-column (μcolumn) chips with cross-linked PDMS wall-coated stationary phases capable of temperature-programmed separations; and an integrated array of five μchemiresistors (μCR) coated with different thiolate-monolayer protected gold nanoparticle (MPN) interface films that quantifies and further differentiates among the analytes by virtue of the response patterns generated. Other key components include a pre-trap for low-volatility interferences, a split-flow injection valve, and an onboard He carrier–gas canister. The assembled unit measures 19×30×14 cm, weighs ~3.5 kg, operates on AC power, and is laptop/LabVIEW controlled. Component- and system-level tests of performance demonstrated injection bandwidths <1 s, a μcolumn capacity of ≥8 μg injected mass, linear calibration curves, no humidity effects, excellent medium-term (that is, 1 week) reproducibility, autonomous operation for 8 h, detection limits below Threshold Limit Values (TLV) for 10 mL air samples collected in 1 min, and response patterns that enhanced vapor recognition. The determination of a 17-VOC mixture in the presence of seven interferences was performed in 4 min. Results augur well for adapting the microsystem to an all-MEMS wearable μGC currently under parallel development.


  • A zone-heated gas chromatographic microcolumn: Energy efficiency

    by Zhijin Lin, Nicolás Nuñovero, Junqi Wang, Robert Nidetz, Sanketh Buggaveeti, Katsuo Kurabayashi, Edward T. Zellers


  • Open Access

    Microscale Gas Chromatography with Microsensor Array Detection: Challenges and Prospects

    by Junqi Wang, Nicolas Nuñovero, Changhua Zhan, Robert Nidetz, William H. Steinecker, Seth J. Peterson, Bryan M. Brookover, Edward T. Zellers

    The capability to analyze complex mixtures of airborne volatile organic compounds (VOCs) at low concentrations; in situ; has implications for environmental monitoring; worker exposure assessment; biomedical diagnostics; and population security. Since standalone microsensor arrays lack this capability; upstream separation of mixture components; often preceded by preconcentration; is required. Although significant advances have been made via MEMS technologies in the development of microscale gas chromatographic (μGC) systems; many challenges remain. This presentation will review selected aspects of the state-of-the-art in μGC for VOC mixture analysis. Here; we emphasize our progress toward a wearable μGC prototype.


  • Micro vapor extractor for on-site determinations of volatile organic compounds in water and biofluids

    by Junqi Wang, Changhua Zhan, Edward T. Zellers, Joseph A. Potkay

    A passive, membrane-mediated, microfabricated vapor extractor (μVE) chip for collecting volatile organic compounds (VOC) from water and biofluids is presented. Its performance when interfaced to a micro-scale gas chromatograph (μGC) prototype is demonstrated. A mixture of 4 VOCs spiked into synthetic urine at ppm concentrations was extracted by the 2.8×2.3 cm μVE chip from a 700-μL sample in 3.5 min, and then preconcentrated, injected, separated and detected by μGC in ~80 sec with detection limits as low as 660 ppb. Response patterns provided by the μGC sensor-array detector facilitated VOC identification. The hybrid μVEμGC microsystem may eventually permit rapid field/clinical analyses of water contaminants and urinary biomarkers of exposure and disease.


  • Open Access

    A Wearable MEMS Gas Chromatograph for Multi-Vapor Determinations

    by J. Wang, N. Nuñovero, Z. Lin, R. Nidetz, S. Buggaveeti, C. Zhan, K. Kurabayashi, W.H. Steinecker, E.T. Zellers


  • A new N-imidazolyl-1,8-naphthalimide based fluorescence sensor for fluoride detection

    by Junqi Wang, Lingyun Yang, Chen Hou, Haishi Cao

    A chemosensor is reported with high sensitivity and selectivity for detection of fluoride anion. The recognition mechanism is attributed to a fluoride-triggered disruption of the hydrogen bond between imidazole and naphthalimide moieties, resulting in a noncoplanar geometry with low fluorescence.