Sanketh Buggaveeti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sanketh Buggaveeti has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
- Robert Nidetz
Department of Mechanical Engineering, University of Michigan, Ann Arbor, USA
4 shared publications - Junqi Wang
Department of Chemistry , University of Michigan , Ann Arbor , Michigan 48109 , United States
3 shared publications A. Karanicolas
Infinera Corporation, 140 Caspian Court, Sunnyvale, CA, 94089
2 shared publicationsBabak Behnia
2 shared publicationsDavid Welch
2 shared publicationsF. Kish
Infinera Corporation, 140 Caspian Court, Sunnyvale, CA, 94089
2 shared publications
Latest Publications
- 1 January 2019
- Published by Optica Publishing Group
- p. SpM4E.3
InP-based Coherent PICs for 100 Gbaud Operation
- 1 January 2019
- Published by Optica Publishing Group
- p. SpM4E.3
InP-based Coherent PICs for 100 Gbaud Operation
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
$4 \times 600$ Gb/s Photonic IC Transmitter and Receiver Modules
InP-based 4×600 Gb/s capable coherent transmitter and receiver assemblies with hybrid integrated SiGe drivers operate at 66GBd, 64QAM over a 200km link. Additionally, a fully packaged pair of modules with real-time DSP ASIC operates error free at 600Gb/s with 69GBd, DP-64QAM.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
$4 \times 600$ Gb/s Photonic IC Transmitter and Receiver Modules
InP-based 4×600 Gb/s capable coherent transmitter and receiver assemblies with hybrid integrated SiGe drivers operate at 66GBd, 64QAM over a 200km link. Additionally, a fully packaged pair of modules with real-time DSP ASIC operates error free at 600Gb/s with 69GBd, DP-64QAM.
- 24 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 54 (4) , 1-10
1.00 (0.88) Tb/s per Wave Capable Coherent Multi-Channel Transmitter (Receiver) InP-Based PICs With Hybrid Integrated SiGe Electronics
We demonstrate multi-channel InP-based coherent transmitter and receiver PICs hybrid integrated with SiGe driving and amplifying electronics both capable of operating at 880 Gb/s and the transmitter alone up to 1 Tb/s per wave. These hybrid assemblies demonstrate optical transmissions across a commercial line system at distances from 200 – 1400 km, with symbol rates between 66 – 100 GBd, utilizing 16, 32, and 64QAM modulation formats. Additionally, we demonstrate a back-to-back transmission from the TxPIC assembly to a reference receiver at 100 GBd x 32QAM, a 1 Tb/s per wavelength capability.
- 24 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 54 (4) , 1-10
1.00 (0.88) Tb/s per Wave Capable Coherent Multi-Channel Transmitter (Receiver) InP-Based PICs With Hybrid Integrated SiGe Electronics
We demonstrate multi-channel InP-based coherent transmitter and receiver PICs hybrid integrated with SiGe driving and amplifying electronics both capable of operating at 880 Gb/s and the transmitter alone up to 1 Tb/s per wave. These hybrid assemblies demonstrate optical transmissions across a commercial line system at distances from 200 – 1400 km, with symbol rates between 66 – 100 GBd, utilizing 16, 32, and 64QAM modulation formats. Additionally, we demonstrate a back-to-back transmission from the TxPIC assembly to a reference receiver at 100 GBd x 32QAM, a 1 Tb/s per wavelength capability.
- Open Access
- 9 April 2018
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 4 (1) , 17101
Compact prototype microfabricated gas chromatographic analyzer for autonomous determinations of VOC mixtures at typical workplace concentrations
This report concerns a benchtop prototype instrument containing a gas chromatographic microanalytical system (μGC) designed for the selective determination of multiple airborne volatile organic compounds (VOCs) at concentrations in the vicinity of recommended occupational exposure limits. The core microsystem consists of a set of discrete Si-microfabricated devices: a dual-cavity, adsorbent-packed micro-preconcentrator-focuser (μPCF) chip that quantitatively captures and thermally desorbs/injects VOCs with vapor pressures between ~0.03 and 13 kPa; tandem micro-column (μcolumn) chips with cross-linked PDMS wall-coated stationary phases capable of temperature-programmed separations; and an integrated array of five μchemiresistors (μCR) coated with different thiolate-monolayer protected gold nanoparticle (MPN) interface films that quantifies and further differentiates among the analytes by virtue of the response patterns generated. Other key components include a pre-trap for low-volatility interferences, a split-flow injection valve, and an onboard He carrier–gas canister. The assembled unit measures 19×30×14 cm, weighs ~3.5 kg, operates on AC power, and is laptop/LabVIEW controlled. Component- and system-level tests of performance demonstrated injection bandwidths <1 s, a μcolumn capacity of ≥8 μg injected mass, linear calibration curves, no humidity effects, excellent medium-term (that is, 1 week) reproducibility, autonomous operation for 8 h, detection limits below Threshold Limit Values (TLV) for 10 mL air samples collected in 1 min, and response patterns that enhanced vapor recognition. The determination of a 17-VOC mixture in the presence of seven interferences was performed in 4 min. Results augur well for adapting the microsystem to an all-MEMS wearable μGC currently under parallel development.
- 9 April 2018
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 4 (1) , 17101
Open AccessCompact prototype microfabricated gas chromatographic analyzer for autonomous determinations of VOC mixtures at typical workplace concentrations
This report concerns a benchtop prototype instrument containing a gas chromatographic microanalytical system (μGC) designed for the selective determination of multiple airborne volatile organic compounds (VOCs) at concentrations in the vicinity of recommended occupational exposure limits. The core microsystem consists of a set of discrete Si-microfabricated devices: a dual-cavity, adsorbent-packed micro-preconcentrator-focuser (μPCF) chip that quantitatively captures and thermally desorbs/injects VOCs with vapor pressures between ~0.03 and 13 kPa; tandem micro-column (μcolumn) chips with cross-linked PDMS wall-coated stationary phases capable of temperature-programmed separations; and an integrated array of five μchemiresistors (μCR) coated with different thiolate-monolayer protected gold nanoparticle (MPN) interface films that quantifies and further differentiates among the analytes by virtue of the response patterns generated. Other key components include a pre-trap for low-volatility interferences, a split-flow injection valve, and an onboard He carrier–gas canister. The assembled unit measures 19×30×14 cm, weighs ~3.5 kg, operates on AC power, and is laptop/LabVIEW controlled. Component- and system-level tests of performance demonstrated injection bandwidths <1 s, a μcolumn capacity of ≥8 μg injected mass, linear calibration curves, no humidity effects, excellent medium-term (that is, 1 week) reproducibility, autonomous operation for 8 h, detection limits below Threshold Limit Values (TLV) for 10 mL air samples collected in 1 min, and response patterns that enhanced vapor recognition. The determination of a 17-VOC mixture in the presence of seven interferences was performed in 4 min. Results augur well for adapting the microsystem to an all-MEMS wearable μGC currently under parallel development.
- 1 January 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 254, 561-572
A zone-heated gas chromatographic microcolumn: Energy efficiency
- 1 January 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 254, 561-572
A zone-heated gas chromatographic microcolumn: Energy efficiency
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Multi-channel InP-based Coherent PICs with Hybrid Integrated SiGe Electronics Operating up to 100 GBd, 32QAM
We report InP-based coherent transmitter PICs with hybrid integrated SiGe drivers operating at 100GBd, 32QAM back-to-back (1 Tb/wave capable), and at 100GBd, 16QAM over 1400km. Coherent Tx (Rx) PICs with hybrid integrated drivers (amplifiers) operate at 66GBd, 64QAM over 200km.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Multi-channel InP-based Coherent PICs with Hybrid Integrated SiGe Electronics Operating up to 100 GBd, 32QAM
We report InP-based coherent transmitter PICs with hybrid integrated SiGe drivers operating at 100GBd, 32QAM back-to-back (1 Tb/wave capable), and at 100GBd, 16QAM over 1400km. Coherent Tx (Rx) PICs with hybrid integrated drivers (amplifiers) operate at 66GBd, 64QAM over 200km.
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 1398-1401
A Wearable MEMS Gas Chromatograph for Multi-Vapor Determinations
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 1398-1401
Open AccessA Wearable MEMS Gas Chromatograph for Multi-Vapor Determinations
- 27 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (14) , 3021-3029
Flow-through microfluidic photoionization detectors for rapid and highly sensitive vapor detection
A photoionization detector (PID) is well known for its high sensitivity, large dynamic range, and non-destructive vapor detection capability. However, due to its tardy response, which results from the relatively large ionization chamber and dead volume, the application of the PID in gas chromatography (GC) has been limited. Here, we developed a rapid, flow-through, and highly sensitive microfluidic PID that was microfabricated directly on a conductive silicon wafer. The microfluidic PID has a significantly reduced ionization chamber volume of only 1.3 μL, nearly 10 times smaller than that of state-of-the-art PIDs and over 100 times smaller than that of commercial PIDs. Moreover, it has virtually zero dead volume due to its flow-through design. Consequently, the response time of the microfluidic PID can be considerably shortened, ultimately limited by its residence time (7.8 ms for 10 mL min−1 and 78 ms for 1 mL min−1). Experimentally, the response of the microfluidic PID was measured to be the same as that of the standard flame ionization detector with peak full-widths-at-half-maximum of 0.25 s and 0.085 s for flow rates of 2.3 mL min−1 and 10 mL min−1, respectively. Our studies further show that the microfluidic PID was able to detect analytes down to the picogram level (at 3σ of noise) and had a linear dynamic range of six orders of magnitude. Finally, because of the very short distance between the electrodes, low voltage (<10 VDC, over 10 times lower than that in a regular PID) can be used for microfluidic PID operation. This work will open a door to broad applications of PIDs in gas analyzers, in particular, micro-GC and multi-dimensional GC.
- 27 May 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (14) , 3021-3029
Flow-through microfluidic photoionization detectors for rapid and highly sensitive vapor detection
A photoionization detector (PID) is well known for its high sensitivity, large dynamic range, and non-destructive vapor detection capability. However, due to its tardy response, which results from the relatively large ionization chamber and dead volume, the application of the PID in gas chromatography (GC) has been limited. Here, we developed a rapid, flow-through, and highly sensitive microfluidic PID that was microfabricated directly on a conductive silicon wafer. The microfluidic PID has a significantly reduced ionization chamber volume of only 1.3 μL, nearly 10 times smaller than that of state-of-the-art PIDs and over 100 times smaller than that of commercial PIDs. Moreover, it has virtually zero dead volume due to its flow-through design. Consequently, the response time of the microfluidic PID can be considerably shortened, ultimately limited by its residence time (7.8 ms for 10 mL min−1 and 78 ms for 1 mL min−1). Experimentally, the response of the microfluidic PID was measured to be the same as that of the standard flame ionization detector with peak full-widths-at-half-maximum of 0.25 s and 0.085 s for flow rates of 2.3 mL min−1 and 10 mL min−1, respectively. Our studies further show that the microfluidic PID was able to detect analytes down to the picogram level (at 3σ of noise) and had a linear dynamic range of six orders of magnitude. Finally, because of the very short distance between the electrodes, low voltage (<10 VDC, over 10 times lower than that in a regular PID) can be used for microfluidic PID operation. This work will open a door to broad applications of PIDs in gas analyzers, in particular, micro-GC and multi-dimensional GC.