Dan Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dan Wu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Cecilia Persson
Department of Materials Science and Engineering Uppsala University Uppsala Sweden
2 shared publications- Cecilia Persson
Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
2 shared publications Per Isaksson
Solid Mechanics, Department of Materials Science and Engineering, Uppsala University, Sweden
2 shared publications- Alicja Bojan
Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
1 shared publication - Caroline Öhman
Department of Materials Science and Engineering, Uppsala University, 75121 Uppsala, Sweden
1 shared publication Caroline Öhman Mägi
Applied Materials Science, Department of Materials Science and Engineering, Uppsala University, Sweden
1 shared publication
Latest Publications
- Open Access
- 18 January 2022
- Published by Spandidos Publications in Experimental and Therapeutic Medicine
- Vol. 23 (3) , 1-9
Biological activity of a vascular endothelial cell‑hydroxyapatite orbital implant complex: An experimental study
The reduction in postoperative complications is a considerable concern after orbital reparation and reconstruction. Selecting the appropriate scaffold materials to improve the survival rates of the seeded cells is a challenge in tissue engineering. The aim of the present study was to evaluate the biological activity of a vascular endothelial cell‑hydroxyapatite orbital complex, which was constructed with tissue engineering and used as an implant after enucleation of the eyeNew Zealand white rabbits were randomly divided into two groups that underwent hydroxyapatite orbital implant surgery in the right eye. The primary orbital microvascular endothelial cells were collected from the microvascular tissue and subsequently cultured. Then, hydroxyapatite ocular implants were cultured with vascular endothelial cells in the endothelial cell (EC) group, and implants were cultured without vascular endothelial cells in the blank group. Characterization of the cells was performed with immunofluorescence staining and a Transwell migration and cell tube formation assay. The levels of interleukin‑8 (IL‑8) and vascular endothelial growth factor (VEGF) in the rabbit conjunctiva were measured with an ELISA. The results showed that the levels of IL‑8 were decreased in the EC group and increased in the blank group. The levels of VEGF were increased in the EC group when compared to the blank group with statistical significance. The average depth of the fibrovascular tissue was obviously thicker in the EC group compared with that found in the blank group. These findings suggest that the vascular endothelial cell‑hydroxyapatite orbital implant complex may be an effective strategy with which to accelerate vascularization and reduce complications of infection with satisfactory biological activity.
- 18 January 2022
- Published by Spandidos Publications in Experimental and Therapeutic Medicine
- Vol. 23 (3) , 1-9
Open AccessBiological activity of a vascular endothelial cell‑hydroxyapatite orbital implant complex: An experimental study
The reduction in postoperative complications is a considerable concern after orbital reparation and reconstruction. Selecting the appropriate scaffold materials to improve the survival rates of the seeded cells is a challenge in tissue engineering. The aim of the present study was to evaluate the biological activity of a vascular endothelial cell‑hydroxyapatite orbital complex, which was constructed with tissue engineering and used as an implant after enucleation of the eyeNew Zealand white rabbits were randomly divided into two groups that underwent hydroxyapatite orbital implant surgery in the right eye. The primary orbital microvascular endothelial cells were collected from the microvascular tissue and subsequently cultured. Then, hydroxyapatite ocular implants were cultured with vascular endothelial cells in the endothelial cell (EC) group, and implants were cultured without vascular endothelial cells in the blank group. Characterization of the cells was performed with immunofluorescence staining and a Transwell migration and cell tube formation assay. The levels of interleukin‑8 (IL‑8) and vascular endothelial growth factor (VEGF) in the rabbit conjunctiva were measured with an ELISA. The results showed that the levels of IL‑8 were decreased in the EC group and increased in the blank group. The levels of VEGF were increased in the EC group when compared to the blank group with statistical significance. The average depth of the fibrovascular tissue was obviously thicker in the EC group compared with that found in the blank group. These findings suggest that the vascular endothelial cell‑hydroxyapatite orbital implant complex may be an effective strategy with which to accelerate vascularization and reduce complications of infection with satisfactory biological activity.
- 1 January 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 125, 104879
A combined experimental and numerical method to estimate the elastic modulus of single trabeculae
- 1 January 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 125, 104879
A combined experimental and numerical method to estimate the elastic modulus of single trabeculae
- Open Access
Density and mechanical properties of vertebral trabecular bone—A review
Being able to predict the mechanical properties of vertebrae in patients with osteoporosis and other relevant pathologies is essential to prevent fractures and to develop the most favorable fracture treatments. Furthermore, a reliable prediction is important for developing more patient‐ and pathology‐specific biomaterials. A plethora of studies correlating bone density to mechanical properties has been reported; however, the results are variable, due to a variety of factors, including anatomical site and methodological differences. The aim of this study was to provide a comprehensive literature review on density and mechanical properties of human vertebral trabecular bone as well as relationships found between these properties. A literature search was performed to include studies, which investigated mechanical properties and bone density of trabecular bone. Only studies on vertebral trabecular bone tissue, reporting bone density or mechanical properties, were kept.A large variation in reported vertebral trabecular bone densities, mechanical properties, and relationships between the two was found, as exemplified by values varying between 0.09 and 0.35 g/cm3 for the wet apparent density and from 0.1 to 976 MPa for the elastic modulus. The differences were found to reflect variations in experimental and analytical processes that had been used, including testing protocol and specimen geometry. The variability in the data decreased in studies where bone tissue testing occurred in a standardized manner (eg, the reported differences in average elastic modulus decreased from 400% to 10%). It is important to take this variability into account when analyzing the predictions found in the literature, for example, to calculate fracture risk, and it is recommended to use the models suggested in the present review to reduce data variability.
Open AccessDensity and mechanical properties of vertebral trabecular bone—A review
Being able to predict the mechanical properties of vertebrae in patients with osteoporosis and other relevant pathologies is essential to prevent fractures and to develop the most favorable fracture treatments. Furthermore, a reliable prediction is important for developing more patient‐ and pathology‐specific biomaterials. A plethora of studies correlating bone density to mechanical properties has been reported; however, the results are variable, due to a variety of factors, including anatomical site and methodological differences. The aim of this study was to provide a comprehensive literature review on density and mechanical properties of human vertebral trabecular bone as well as relationships found between these properties. A literature search was performed to include studies, which investigated mechanical properties and bone density of trabecular bone. Only studies on vertebral trabecular bone tissue, reporting bone density or mechanical properties, were kept.A large variation in reported vertebral trabecular bone densities, mechanical properties, and relationships between the two was found, as exemplified by values varying between 0.09 and 0.35 g/cm3 for the wet apparent density and from 0.1 to 976 MPa for the elastic modulus. The differences were found to reflect variations in experimental and analytical processes that had been used, including testing protocol and specimen geometry. The variability in the data decreased in studies where bone tissue testing occurred in a standardized manner (eg, the reported differences in average elastic modulus decreased from 400% to 10%). It is important to take this variability into account when analyzing the predictions found in the literature, for example, to calculate fracture risk, and it is recommended to use the models suggested in the present review to reduce data variability.
- Open Access
- 1 August 2019
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 168, 211-227
A global digital volume correlation algorithm based on higher-order finite elements: Implementation and evaluation
- 1 August 2019
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 168, 211-227
Open AccessA global digital volume correlation algorithm based on higher-order finite elements: Implementation and evaluation
- 1 November 2014
- Published by Elsevier in Electrochimica Acta
- Vol. 146, 125-133
New Strategy for Electrochemical Micropatterning of Nafion Film in Sulfuric Acid Solution
- 1 November 2014
- Published by Elsevier in Electrochimica Acta
- Vol. 146, 125-133
New Strategy for Electrochemical Micropatterning of Nafion Film in Sulfuric Acid Solution