Shu-Lin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shu-Lin Zhang has a total of 182 co-authors. Here are the top co-authors by number of shared publications:
- Guofeng Zhang
Shanghai Key Laboratory of Superconductor Integrated Circuit Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
7 shared publications - Yongliang Wang
Shanghai Institute of Microsystem and Information Technology (SIMIT), Chinese Academy of Sciences (CAS), Shanghai, China
7 shared publications Xiaoming Xie
Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
6 shared publications- Dao-Zhen Xu
Center of Hepatology, Beijing Ditan Hospital, Capital Medical University, No. 8 Jingshun East Street, Chaoyang District, Beijing, 100015, China
5 shared publications - Yingren Zhao
Department of Infectious Diseases, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an City, Shaanxi Province, China
5 shared publications Zhi-Meng Lu
5 shared publications
Latest Publications
- Open Access
Performance Characterization and Optimization of a Miniaturized SERF Atomic Magnetometer via Tunable Laser Power
Spin-exchange relaxation-free (SERF) atomic magnetometers have emerged as highly promising candidates for ultra-weak magnetic field detection, particularly in biomagnetic imaging, owing to their exceptional sensitivity, amenability to miniaturization, and near-room-temperature operation. While current miniaturized magnetometers typically employ laser chips with fixed optical power, the quantitative impact of laser power on critical performance metrics remains to be fully elucidated. This study systematically investigates the influence of laser power on sensitivity, bandwidth, and dynamic range by incorporating considerations of power broadening, saturation absorption, and noise constraints. A miniaturized probe, integrated with an actively controlled vertical-cavity surface-emitting laser (VCSEL), was developed for experimental validation. Theoretical and experimental results consistently demonstrate that as optical power increases, sensitivity exhibits a non-monotonic dependence, whereas both bandwidth and dynamic range manifest a monotonic upward trend, aligning well with theoretical simulations. The optimized sensor achieved a peak sensitivity of 16 fT/√Hz at 300 μW, while the bandwidth and dynamic range reached 230 Hz and ±5.4 nT at 500 μW, respectively. This work establishes a robust theoretical and experimental framework for the comprehensive performance optimization of laser-integrated miniaturized atomic magnetometers.
Open AccessPerformance Characterization and Optimization of a Miniaturized SERF Atomic Magnetometer via Tunable Laser Power
Spin-exchange relaxation-free (SERF) atomic magnetometers have emerged as highly promising candidates for ultra-weak magnetic field detection, particularly in biomagnetic imaging, owing to their exceptional sensitivity, amenability to miniaturization, and near-room-temperature operation. While current miniaturized magnetometers typically employ laser chips with fixed optical power, the quantitative impact of laser power on critical performance metrics remains to be fully elucidated. This study systematically investigates the influence of laser power on sensitivity, bandwidth, and dynamic range by incorporating considerations of power broadening, saturation absorption, and noise constraints. A miniaturized probe, integrated with an actively controlled vertical-cavity surface-emitting laser (VCSEL), was developed for experimental validation. Theoretical and experimental results consistently demonstrate that as optical power increases, sensitivity exhibits a non-monotonic dependence, whereas both bandwidth and dynamic range manifest a monotonic upward trend, aligning well with theoretical simulations. The optimized sensor achieved a peak sensitivity of 16 fT/√Hz at 300 μW, while the bandwidth and dynamic range reached 230 Hz and ±5.4 nT at 500 μW, respectively. This work establishes a robust theoretical and experimental framework for the comprehensive performance optimization of laser-integrated miniaturized atomic magnetometers.
- Open Access
- 19 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
AI-enabled diagnosis and localization of myocardial ischemia and coronary artery stenosis from magnetocardiographic recordings
Early diagnosis and localization of myocardial ischemia (MS) and coronary artery stenosis (CAS) play a crucial role in the effective prevention and management of ischemic heart disease (IHD). Magnetocardiography (MCG) has emerged as a promising approach for non-invasive, non-contact, and high-sensitivity assessment of cardiac dysfunction. This study presents a multi-center, AI-enabled diagnosis and localization of myocardial ischemia and coronary artery stenosis from MCG data. To this end, we collected a large-scale dataset consisting of 2,158 MCG recordings from eight clinical centers. We then proposed a multiscale vision transformer-based network for extracting spatio-temporal information from multichannel MCG recordings. Anatomical prior knowledge of the coronary artery and the irrigated left ventricular regions was incorporated by a carefully designed graph convolutional network (GCN)-based feature fusion module. The proposed approach achieved an accuracy of 84.7%, a sensitivity of 83.8%, and a specificity of 85.6% in diagnosing IHD, an average accuracy of 78.4% in localization of five MS regions, and an average accuracy of 65.3% in localization of stenosis in three coronary arteries. Subsequent validation on an independent validation dataset consisting of 268 MCG recordings collected from four clinical centers demonstrated an accuracy of 82.3%, a sensitivity of 83.8%, and a specificity of 81.3% in diagnosing IHD, an average accuracy of 77.3% in localization of five myocardial ischemic regions, and an average accuracy of 65.6% in localization of stenosis in three coronary arteries. The proposed approach can be used as a fast and accurate diagnosis tool, boosting the integration of MCG examination into clinical routine.
- 19 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessAI-enabled diagnosis and localization of myocardial ischemia and coronary artery stenosis from magnetocardiographic recordings
Early diagnosis and localization of myocardial ischemia (MS) and coronary artery stenosis (CAS) play a crucial role in the effective prevention and management of ischemic heart disease (IHD). Magnetocardiography (MCG) has emerged as a promising approach for non-invasive, non-contact, and high-sensitivity assessment of cardiac dysfunction. This study presents a multi-center, AI-enabled diagnosis and localization of myocardial ischemia and coronary artery stenosis from MCG data. To this end, we collected a large-scale dataset consisting of 2,158 MCG recordings from eight clinical centers. We then proposed a multiscale vision transformer-based network for extracting spatio-temporal information from multichannel MCG recordings. Anatomical prior knowledge of the coronary artery and the irrigated left ventricular regions was incorporated by a carefully designed graph convolutional network (GCN)-based feature fusion module. The proposed approach achieved an accuracy of 84.7%, a sensitivity of 83.8%, and a specificity of 85.6% in diagnosing IHD, an average accuracy of 78.4% in localization of five MS regions, and an average accuracy of 65.3% in localization of stenosis in three coronary arteries. Subsequent validation on an independent validation dataset consisting of 268 MCG recordings collected from four clinical centers demonstrated an accuracy of 82.3%, a sensitivity of 83.8%, and a specificity of 81.3% in diagnosing IHD, an average accuracy of 77.3% in localization of five myocardial ischemic regions, and an average accuracy of 65.6% in localization of stenosis in three coronary arteries. The proposed approach can be used as a fast and accurate diagnosis tool, boosting the integration of MCG examination into clinical routine.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 4450-4459
A Metal Film Thickness Measurement System With a Large Range Based on High-Performance ME Sensors
The majority of traditional eddy current-based metal film thickness measurement systems measure the thickness of the metal film by detecting changes in the impedance or voltage of the detection coil, leading to limited measurement range and susceptibility to measurement errors caused by variations in lift-off distance. This article proposes a method for metal film thickness measurement across a wide range using a high-performance magnetoelectric (ME) sensor to directly detect the total magnetic field of the excitation field and the induced field. Numerical calculations based on the eddy current magnetic field model reveal a highly linear relationship within a specific range between this total magnetic field and the logarithm of the metal film thickness. If the detectable magnetic field range of the magnetic field sensor covers 32–51 nT with a bandwidth of up to 1.5 MHz, theoretically, the measurement of copper film thickness within the range of 0.65 nm–1000 $\mu$ m can be achieved by adjusting the excitation magnetic field frequency, and the measurement error introduced by the lift-off distance can also be ignored. The experimentally prepared ME sensor, covering a range of 30 pT–100 nT within a bandwidth of 1.5 kHz–1.5 MHz, was used to construct a metal film thickness measurement system. Measurements on copper films with thicknesses ranging from nanometers to micrometers, under excitation fields at six different frequency excitation fields within the range of 1.5 kHz–1.5 MHz, exhibited measurement errors within 1%, confirming the feasibility of this method for a wide range of copper film thicknesses from 60 nm–350 $\mu$ m.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 4450-4459
A Metal Film Thickness Measurement System With a Large Range Based on High-Performance ME Sensors
The majority of traditional eddy current-based metal film thickness measurement systems measure the thickness of the metal film by detecting changes in the impedance or voltage of the detection coil, leading to limited measurement range and susceptibility to measurement errors caused by variations in lift-off distance. This article proposes a method for metal film thickness measurement across a wide range using a high-performance magnetoelectric (ME) sensor to directly detect the total magnetic field of the excitation field and the induced field. Numerical calculations based on the eddy current magnetic field model reveal a highly linear relationship within a specific range between this total magnetic field and the logarithm of the metal film thickness. If the detectable magnetic field range of the magnetic field sensor covers 32–51 nT with a bandwidth of up to 1.5 MHz, theoretically, the measurement of copper film thickness within the range of 0.65 nm–1000 $\mu$ m can be achieved by adjusting the excitation magnetic field frequency, and the measurement error introduced by the lift-off distance can also be ignored. The experimentally prepared ME sensor, covering a range of 30 pT–100 nT within a bandwidth of 1.5 kHz–1.5 MHz, was used to construct a metal film thickness measurement system. Measurements on copper films with thicknesses ranging from nanometers to micrometers, under excitation fields at six different frequency excitation fields within the range of 1.5 kHz–1.5 MHz, exhibited measurement errors within 1%, confirming the feasibility of this method for a wide range of copper film thicknesses from 60 nm–350 $\mu$ m.
- 1 April 2024
- Published by Tsinghua University Press in Journal of Geriatric Cardiology
- Vol. 21 (4) , 407-420
Accurate diagnosis of severe coronary stenosis based on resting magnetocardiography: a prospective, single-center, cross-sectional analysis
OBJECTIVE To evaluate the role of resting magnetocardiography in identifying severe coronary artery stenosis in patients with suspected coronary artery disease. METHODS A total of 513 patients with angina symptoms were included and divided into two groups based on the extent of coronary artery disease determined by angiography: the non-severe coronary stenosis group (< 70% stenosis) and the severe coronary stenosis group (≥ 70% stenosis). The diagnostic model was constructed using magnetic field map (MFM) parameters, either individually or in combination with clinical indicators. The performance of the models was evaluated using receiver operating characteristic curves, accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Calibration plots and decision curve analysis were performed to investigate the clinical utility and performance of the models, respectively. RESULTS In the severe coronary stenosis group, QR_MCTDd, S_MDp, and TT_MAC50 were significantly higher than those in the non-severe coronary stenosis group (10.46 ± 10.66 vs. 5.11 ± 6.07, P < 0.001; 7.2 ± 8.64 vs. 4.68 ± 6.95, P = 0.003; 0.32 ± 57.29 vs. 0.26 ± 57.29, P < 0.001). While, QR_MVamp, R_MA, and T_MA in the severe coronary stenosis group were lower (0.23 ± 0.16 vs. 0.28 ± 0.16, P < 0.001; 55.06 ± 48.68 vs. 59.24 ± 53.01, P < 0.001; 51.67 ± 39.32 vs. 60.45 ± 51.33, P < 0.001). Seven MFM parameters were integrated into the model, resulting in an area under the curve of 0.810 (95% CI: 0.765–0.855). The sensitivity, specificity, PPV, NPV, and accuracy were 71.7%, 80.4%, 93.3%, 42.8%, and 73.5%; respectively. The combined model exhibited an area under the curve of 0.845 (95% CI: 0.798–0.892). The sensitivity, specificity, PPV, NPV, and accuracy were 84.3%, 73.8%, 92.6%, 54.6%, and 82.1%; respectively. Calibration curves demonstrated excellent agreement between the nomogram prediction and actual observation. The decision curve analysis showed that the combined model provided greater net benefit compared to the magnetocardiography model. CONCLUSIONS The novel quantitative MFM parameters, whether used individually or in combination with clinical indicators, have been shown to effectively predict the risk of severe coronary stenosis in patients presenting with angina-like symptoms. Magnetocardiography, an emerging non-invasive diagnostic tool, warrants further exploration for its potential in diagnosing coronary heart disease.
- 1 April 2024
- Published by Tsinghua University Press in Journal of Geriatric Cardiology
- Vol. 21 (4) , 407-420
Accurate diagnosis of severe coronary stenosis based on resting magnetocardiography: a prospective, single-center, cross-sectional analysis
OBJECTIVE To evaluate the role of resting magnetocardiography in identifying severe coronary artery stenosis in patients with suspected coronary artery disease. METHODS A total of 513 patients with angina symptoms were included and divided into two groups based on the extent of coronary artery disease determined by angiography: the non-severe coronary stenosis group (< 70% stenosis) and the severe coronary stenosis group (≥ 70% stenosis). The diagnostic model was constructed using magnetic field map (MFM) parameters, either individually or in combination with clinical indicators. The performance of the models was evaluated using receiver operating characteristic curves, accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Calibration plots and decision curve analysis were performed to investigate the clinical utility and performance of the models, respectively. RESULTS In the severe coronary stenosis group, QR_MCTDd, S_MDp, and TT_MAC50 were significantly higher than those in the non-severe coronary stenosis group (10.46 ± 10.66 vs. 5.11 ± 6.07, P < 0.001; 7.2 ± 8.64 vs. 4.68 ± 6.95, P = 0.003; 0.32 ± 57.29 vs. 0.26 ± 57.29, P < 0.001). While, QR_MVamp, R_MA, and T_MA in the severe coronary stenosis group were lower (0.23 ± 0.16 vs. 0.28 ± 0.16, P < 0.001; 55.06 ± 48.68 vs. 59.24 ± 53.01, P < 0.001; 51.67 ± 39.32 vs. 60.45 ± 51.33, P < 0.001). Seven MFM parameters were integrated into the model, resulting in an area under the curve of 0.810 (95% CI: 0.765–0.855). The sensitivity, specificity, PPV, NPV, and accuracy were 71.7%, 80.4%, 93.3%, 42.8%, and 73.5%; respectively. The combined model exhibited an area under the curve of 0.845 (95% CI: 0.798–0.892). The sensitivity, specificity, PPV, NPV, and accuracy were 84.3%, 73.8%, 92.6%, 54.6%, and 82.1%; respectively. Calibration curves demonstrated excellent agreement between the nomogram prediction and actual observation. The decision curve analysis showed that the combined model provided greater net benefit compared to the magnetocardiography model. CONCLUSIONS The novel quantitative MFM parameters, whether used individually or in combination with clinical indicators, have been shown to effectively predict the risk of severe coronary stenosis in patients presenting with angina-like symptoms. Magnetocardiography, an emerging non-invasive diagnostic tool, warrants further exploration for its potential in diagnosing coronary heart disease.
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (9) , 1-7
Simulations and Experiments on Crosstalk of Multichannel SQUID Sensor Array for Magnetoneurography
For complex SQUID biomagnetic systems, such as multi-channel magnetoneurography, channel crosstalk has been studied and solved to some extent, but the crosstalk effects of superconductors themselves are rarely considered. In this paper, the crosstalk characteristics of superconducting coils induced by electromagnetic mutual inductance and Meissner effect were studied. Through simulation calculation, the main influence range of superconductivity diamagnetic effect is within 1 mm. When coil distance <0.5 mm, diamagnetic effect becomes the dominant factor of coil crosstalk. The simulation theory and results are verified by a three-coil crosstalk experimental system. In addition, one new calibration method for the crosstalk errors compensation is proposed and the crosstalk rate is successfully suppressed below 5‰ under the Magnetoneurography measurement environment. It provides a way to analyze and solve the problem for the large complex systems with many dense superconductors.
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (9) , 1-7
Simulations and Experiments on Crosstalk of Multichannel SQUID Sensor Array for Magnetoneurography
For complex SQUID biomagnetic systems, such as multi-channel magnetoneurography, channel crosstalk has been studied and solved to some extent, but the crosstalk effects of superconductors themselves are rarely considered. In this paper, the crosstalk characteristics of superconducting coils induced by electromagnetic mutual inductance and Meissner effect were studied. Through simulation calculation, the main influence range of superconductivity diamagnetic effect is within 1 mm. When coil distance <0.5 mm, diamagnetic effect becomes the dominant factor of coil crosstalk. The simulation theory and results are verified by a three-coil crosstalk experimental system. In addition, one new calibration method for the crosstalk errors compensation is proposed and the crosstalk rate is successfully suppressed below 5‰ under the Magnetoneurography measurement environment. It provides a way to analyze and solve the problem for the large complex systems with many dense superconductors.
- 15 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (3) , 1057-1067
MCG-Net: End-to-End Fine-Grained Delineation and Diagnostic Classification of Cardiac Events From Magnetocardiographs
In this paper, we propose an end-to-end deep learning architecture, referred as MCG-Net, integrating convolutional neural network (CNN) with transformer-based global context block for fine-grained delineation and diagnostic classification of four cardiac events from magnetocardiogram (MCG) data, namely Q-, R-, S- and T-waves. MCG-Net takes advantage of a multi-resolution CNN backbone as well as the state-of-the-art (SOTA) transformer encoders that facilitate global temporal feature aggregation. Besides the novel network architecture, we introduce a multi-task learning scheme to achieve simultaneous delineation and classification. Specifically, the problem of MCG delineation is formulated as multi-class heatmap regression. Meanwhile, a binary diagnostic classification label as well as a duration are jointly estimated for each cardiac event using features that are temporally aligned by event heatmaps. The framework is evaluated on a clinical MCG dataset, containing data collected from 270 subjects with cardiac anomalies and 108 control subjects. We designed and conducted a two-fold cross-validation study to validate the proposed method and to compare its performance with the SOTA methods. Experimental results demonstrated that our method outperformed counterparts on both event delineation and diagnostic classification tasks, achieving respectively an average ECG-F1 of 0.987 and an average Event-F1 of 0.975 for MCG delineation, and an average accuracy of 0.870, an average sensitivity of 0.732, an average specificity of 0.914 and an average AUC of 0.903 for diagnostic classification. Comprehensive ablation experiments are additionally performed to investigate effectiveness of different network components.
- 15 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 26 (3) , 1057-1067
MCG-Net: End-to-End Fine-Grained Delineation and Diagnostic Classification of Cardiac Events From Magnetocardiographs
In this paper, we propose an end-to-end deep learning architecture, referred as MCG-Net, integrating convolutional neural network (CNN) with transformer-based global context block for fine-grained delineation and diagnostic classification of four cardiac events from magnetocardiogram (MCG) data, namely Q-, R-, S- and T-waves. MCG-Net takes advantage of a multi-resolution CNN backbone as well as the state-of-the-art (SOTA) transformer encoders that facilitate global temporal feature aggregation. Besides the novel network architecture, we introduce a multi-task learning scheme to achieve simultaneous delineation and classification. Specifically, the problem of MCG delineation is formulated as multi-class heatmap regression. Meanwhile, a binary diagnostic classification label as well as a duration are jointly estimated for each cardiac event using features that are temporally aligned by event heatmaps. The framework is evaluated on a clinical MCG dataset, containing data collected from 270 subjects with cardiac anomalies and 108 control subjects. We designed and conducted a two-fold cross-validation study to validate the proposed method and to compare its performance with the SOTA methods. Experimental results demonstrated that our method outperformed counterparts on both event delineation and diagnostic classification tasks, achieving respectively an average ECG-F1 of 0.987 and an average Event-F1 of 0.975 for MCG delineation, and an average accuracy of 0.870, an average sensitivity of 0.732, an average specificity of 0.914 and an average AUC of 0.903 for diagnostic classification. Comprehensive ablation experiments are additionally performed to investigate effectiveness of different network components.
- 24 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (7) , 1-7
Noise Performance Comparison Between Current- and Voltage-Bias Readout Schemes for DC SQUID
There are two bias schemes, namely current-bias and voltage-bias, for the directly coupled readout circuit of direct current superconducting quantum interference device (dc SQUID). In order to find out the difference between two bias schemes, we present the theoretical analyses on their equivalent circuits, working point locations, and noise performances. The theoretical analysis and experimental validation prove that the voltage-bias scheme achieves a larger transfer coefficient and exhibits a better noise performance than the current-bias scheme in the reading of conventional dc SQUID.
- 24 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (7) , 1-7
Noise Performance Comparison Between Current- and Voltage-Bias Readout Schemes for DC SQUID
There are two bias schemes, namely current-bias and voltage-bias, for the directly coupled readout circuit of direct current superconducting quantum interference device (dc SQUID). In order to find out the difference between two bias schemes, we present the theoretical analyses on their equivalent circuits, working point locations, and noise performances. The theoretical analysis and experimental validation prove that the voltage-bias scheme achieves a larger transfer coefficient and exhibits a better noise performance than the current-bias scheme in the reading of conventional dc SQUID.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (3) , 1-4
Simulation and Experimentation of Flux Jump in SQUID Magnetometer Under the Geomagnetic Field
It has been found that when superconducting quantum interference device magnetometers operate in a geomagnetic field environment, its output will occasionally show small momentary jumps with the change of the external magnetic field, which seriously affects the measurement accuracy of the geomagnetic field and needs to be eliminated. A magnetic flux jump model called the parasitic superconducting ring model was built to explain the causes of these small jumps, and Helmholtz coils were set up to study the jump and verify this model in the laboratory. The experimental results showed that the position and amplitude of the jumps were consistent with the model. It is believed that this model can guide the design of superconducting chips in geophysical applications.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (3) , 1-4
Simulation and Experimentation of Flux Jump in SQUID Magnetometer Under the Geomagnetic Field
It has been found that when superconducting quantum interference device magnetometers operate in a geomagnetic field environment, its output will occasionally show small momentary jumps with the change of the external magnetic field, which seriously affects the measurement accuracy of the geomagnetic field and needs to be eliminated. A magnetic flux jump model called the parasitic superconducting ring model was built to explain the causes of these small jumps, and Helmholtz coils were set up to study the jump and verify this model in the laboratory. The experimental results showed that the position and amplitude of the jumps were consistent with the model. It is believed that this model can guide the design of superconducting chips in geophysical applications.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (8) , 1-9
Analysis and Simulation of Multi-Loop SQUID-Based Electric Circuits With Mesh-Current Method
Practical superconducting quantum interference devices (SQUIDs) have been developed into multiloop hybrid electric circuits with Josephson junctions and normal elements such as resistor, inductor and capacitor. To find a common circuit analysis and simulation method for different types of SQUID hybrid circuits consist of both superconducting and normal components, we introduce a mesh-current method, which can derive both the general system model and uniform circuit equations directly from the equivalent circuit. The mesh-current method is demonstrated in the simulation of a SQUID additional positive feedback circuit. The numerical simulation results are presented and verified with the measurements. Compared with the conventional nodal analysis method, the mesh-current method is excellent in dealing with the relations including external flux, self and mutual inductances in multiloop hybrid circuit analysis; its final circuit equations directly exhibit the physical theorems; its general system model reveals the quantum interference mechanism inside SQUID circuits, and is applicable for further dynamics studies.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (8) , 1-9
Analysis and Simulation of Multi-Loop SQUID-Based Electric Circuits With Mesh-Current Method
Practical superconducting quantum interference devices (SQUIDs) have been developed into multiloop hybrid electric circuits with Josephson junctions and normal elements such as resistor, inductor and capacitor. To find a common circuit analysis and simulation method for different types of SQUID hybrid circuits consist of both superconducting and normal components, we introduce a mesh-current method, which can derive both the general system model and uniform circuit equations directly from the equivalent circuit. The mesh-current method is demonstrated in the simulation of a SQUID additional positive feedback circuit. The numerical simulation results are presented and verified with the measurements. Compared with the conventional nodal analysis method, the mesh-current method is excellent in dealing with the relations including external flux, self and mutual inductances in multiloop hybrid circuit analysis; its final circuit equations directly exhibit the physical theorems; its general system model reveals the quantum interference mechanism inside SQUID circuits, and is applicable for further dynamics studies.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (8) , 1-7
Analysis of LC-Resonance in DC SQUID Using Dynamic System Model
Direct current superconducting quantum interference device (dc SQUID) can be regarded as a hybrid system with two nonlinear Josephson currents driving a linear network consists of conventional resistors (R), inductors (L), and capacitors (C). There must be LC resonances inside the SQUID loop with influences on its static current-voltage characteristics. To study the working principle of the LC resonance, we build an equivalent dynamic system model transformed directly from the circuit equations of dc SQUID. With dynamic system analyses in both dc and alternating current (ac) domains, we derive the analytical expressions of the resonance point with only the RLC circuit parameters. The analytical derivation proves that the LC resonance inside a symmetrical dc SQUID with resonance frequency ω = 1/√LC results in the flux modulation suppression with I-V curves concentrated on one resonance point. Based on those mathematical expressions, the resonance point is easily indentified from the measured I-V curves, and can be utilized for practical SQUID parameters characterization.
- 15 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (8) , 1-7
Analysis of LC-Resonance in DC SQUID Using Dynamic System Model
Direct current superconducting quantum interference device (dc SQUID) can be regarded as a hybrid system with two nonlinear Josephson currents driving a linear network consists of conventional resistors (R), inductors (L), and capacitors (C). There must be LC resonances inside the SQUID loop with influences on its static current-voltage characteristics. To study the working principle of the LC resonance, we build an equivalent dynamic system model transformed directly from the circuit equations of dc SQUID. With dynamic system analyses in both dc and alternating current (ac) domains, we derive the analytical expressions of the resonance point with only the RLC circuit parameters. The analytical derivation proves that the LC resonance inside a symmetrical dc SQUID with resonance frequency ω = 1/√LC results in the flux modulation suppression with I-V curves concentrated on one resonance point. Based on those mathematical expressions, the resonance point is easily indentified from the measured I-V curves, and can be utilized for practical SQUID parameters characterization.