Rüdiger Hoffmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rüdiger Hoffmann has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
Stephan Clasen
Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
10 shared publicationsKonstantin Nikolaou
Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
7 shared publicationsGunnar Blumenstock
Institute for Clinical Epidemiology and Applied Biometry, University Hospital of Tübingen, Silcherstraße 5, 72076, Tübingen, Germany
5 shared publicationsHansjörg Rempp
Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
5 shared publicationsJakob Weiß
Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
5 shared publications- Konstantin Nikolaou
Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
5 shared publications
Latest Publications
- Open Access
Evaluating Pre-Interventional Administration of a Liver-Specific Contrast Agent During MRI-Guided Thermal Ablation of Malignant Liver Lesions
Background/Objectives: Hepatocyte-specific contrast agent (Gd-EOB-DTPA) can improve the detection of liver lesions during MRI-guided thermal ablation. This study aimed to assess the impact of contrast agent administration on the delineation of the ablation zone during therapy monitoring. Methods: From 2010 to 2020, 358 patients with primary and secondary hepatic malignancies underwent MRI-guided thermoablation. A total of 27 patients with 30 liver lesions received Gd-EOB-DTPA during the procedure to improve target lesion visibility (Group 1), while 30 patients with 30 lesions underwent MRI-guided thermoablation without contrast administration (Group 2). T1-weighted volumetric interpolated breath-hold examination (VIBE) sequences were used for intraprocedural imaging, and post-procedural control imaging involved intravenous Gadobutrol administration in both groups. The contrast-to-noise ratio (CNR) was assessed for three key structures: the target lesion before applicator placement, the ablation zone during unenhanced therapy monitoring, and the ablation zone in contrast-enhanced control imaging. A statistical comparison of CNR values between the two groups was performed using the non-parametric Wilcoxon test (p < 0.05). Results: The CNR of lesions in group 1 significantly increased following the administration of Gd-EOB-DTPA. During therapy monitoring, the ablation zone in group 2 exhibited a significantly higher CNR compared to group 1 (median: 7.9 vs. 2.1; p < 0.001). Similarly, at the contrast-enhanced final control, the CNR of the ablation zone remained significantly greater in group 2 than in group 1 (median: 7.7 vs. 2.0; p < 0.001). Conclusions: The administration of a hepatocyte-specific contrast agent (Gd-EOB-DTPA) prior to intervention improves the visualization of liver lesions that are poorly demarcated but significantly reduces the contrast of the ablation zone during intra- and post-procedural imaging. Therefore, its use should be reserved for cases in which the target lesion cannot be sufficiently delineated without contrast.
Open AccessEvaluating Pre-Interventional Administration of a Liver-Specific Contrast Agent During MRI-Guided Thermal Ablation of Malignant Liver Lesions
Background/Objectives: Hepatocyte-specific contrast agent (Gd-EOB-DTPA) can improve the detection of liver lesions during MRI-guided thermal ablation. This study aimed to assess the impact of contrast agent administration on the delineation of the ablation zone during therapy monitoring. Methods: From 2010 to 2020, 358 patients with primary and secondary hepatic malignancies underwent MRI-guided thermoablation. A total of 27 patients with 30 liver lesions received Gd-EOB-DTPA during the procedure to improve target lesion visibility (Group 1), while 30 patients with 30 lesions underwent MRI-guided thermoablation without contrast administration (Group 2). T1-weighted volumetric interpolated breath-hold examination (VIBE) sequences were used for intraprocedural imaging, and post-procedural control imaging involved intravenous Gadobutrol administration in both groups. The contrast-to-noise ratio (CNR) was assessed for three key structures: the target lesion before applicator placement, the ablation zone during unenhanced therapy monitoring, and the ablation zone in contrast-enhanced control imaging. A statistical comparison of CNR values between the two groups was performed using the non-parametric Wilcoxon test (p < 0.05). Results: The CNR of lesions in group 1 significantly increased following the administration of Gd-EOB-DTPA. During therapy monitoring, the ablation zone in group 2 exhibited a significantly higher CNR compared to group 1 (median: 7.9 vs. 2.1; p < 0.001). Similarly, at the contrast-enhanced final control, the CNR of the ablation zone remained significantly greater in group 2 than in group 1 (median: 7.7 vs. 2.0; p < 0.001). Conclusions: The administration of a hepatocyte-specific contrast agent (Gd-EOB-DTPA) prior to intervention improves the visualization of liver lesions that are poorly demarcated but significantly reduces the contrast of the ablation zone during intra- and post-procedural imaging. Therefore, its use should be reserved for cases in which the target lesion cannot be sufficiently delineated without contrast.
- Open Access
- 24 November 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2181
Deep Learning Applications in Magnetic Resonance Imaging: Has the Future Become Present?
Deep learning technologies and applications demonstrate one of the most important upcoming developments in radiology. The impact and influence of these technologies on image acquisition and reporting might change daily clinical practice. The aim of this review was to present current deep learning technologies, with a focus on magnetic resonance image reconstruction. The first part of this manuscript concentrates on the basic technical principles that are necessary for deep learning image reconstruction. The second part highlights the translation of these techniques into clinical practice. The third part outlines the different aspects of image reconstruction techniques, and presents a review of the current literature regarding image reconstruction and image post-processing in MRI. The promising results of the most recent studies indicate that deep learning will be a major player in radiology in the upcoming years. Apart from decision and diagnosis support, the major advantages of deep learning magnetic resonance imaging reconstruction techniques are related to acquisition time reduction and the improvement of image quality. The implementation of these techniques may be the solution for the alleviation of limited scanner availability via workflow acceleration. It can be assumed that this disruptive technology will change daily routines and workflows permanently.
- 24 November 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (12) , 2181
Open AccessDeep Learning Applications in Magnetic Resonance Imaging: Has the Future Become Present?
Deep learning technologies and applications demonstrate one of the most important upcoming developments in radiology. The impact and influence of these technologies on image acquisition and reporting might change daily clinical practice. The aim of this review was to present current deep learning technologies, with a focus on magnetic resonance image reconstruction. The first part of this manuscript concentrates on the basic technical principles that are necessary for deep learning image reconstruction. The second part highlights the translation of these techniques into clinical practice. The third part outlines the different aspects of image reconstruction techniques, and presents a review of the current literature regarding image reconstruction and image post-processing in MRI. The promising results of the most recent studies indicate that deep learning will be a major player in radiology in the upcoming years. Apart from decision and diagnosis support, the major advantages of deep learning magnetic resonance imaging reconstruction techniques are related to acquisition time reduction and the improvement of image quality. The implementation of these techniques may be the solution for the alleviation of limited scanner availability via workflow acceleration. It can be assumed that this disruptive technology will change daily routines and workflows permanently.
- 25 May 2021
- Published by SAGE Publications in Acta Radiologica
- Vol. 63 (5) , 577-585
Efficacy and tolerability of chemosaturation in patients with hepatic metastases from uveal melanoma
Background: Patients with hepatic metastatic uveal melanoma still have a poor outcome. Purpose: To evaluate overall survival (OS), progression-free survival (PFS), and response predictors in these patients treated with chemosaturation by percutaneous hepatic perfusion with melphalan (CS-PHP). Material and Methods: Between June 2015 and March 2020, a total of 29 patients (median age 69.7 years; age range 30–81 years; 60% women; median BMI 25.7 kg/m2; range 18.7–35.3kg/m2; 1–6 procedures per patient) were treated with 53 CS-PHPs. All patients received cross-sectional imaging for initial and follow-up examinations. Baseline tumor load, extrahepatic tumor load, tumor response, PFS, and OS were assessed. Non-parametric statistics were used. Results: After the initial CS-PHP, a partial response was observed in 11 patients (41%), stable disease in 12 patients (44%) and progressive disease in 4 patients (15%); two patients died before the response was evaluated. After initial CS-PHP, median OS was 12.9 ± 7.4 months and median PFS was 7.1 ± 7.4 months. OS after one year was 50%. After the second CS-PHP, median PFS was 7.9 ± 5.7 months. Seven patients had a liver tumor burden >25%, associated with a significantly shorter OS (6.0 ± 2.4 vs. 14.1 ± 12.7 months; P = 0.008). At the time of first CS-PHP, 41% (12/29) of the patients had extrahepatic metastases that did not affect OS (11.1 ± 8.4 months vs. 12.9 ± 13.6 months; P = 0.66). Conclusion: CS-PHP is a safe and effective treatment for the hepatic metastatic uveal melanoma, especially for patients with a hepatic tumor burden <25%.
- 25 May 2021
- Published by SAGE Publications in Acta Radiologica
- Vol. 63 (5) , 577-585
Efficacy and tolerability of chemosaturation in patients with hepatic metastases from uveal melanoma
Background: Patients with hepatic metastatic uveal melanoma still have a poor outcome. Purpose: To evaluate overall survival (OS), progression-free survival (PFS), and response predictors in these patients treated with chemosaturation by percutaneous hepatic perfusion with melphalan (CS-PHP). Material and Methods: Between June 2015 and March 2020, a total of 29 patients (median age 69.7 years; age range 30–81 years; 60% women; median BMI 25.7 kg/m2; range 18.7–35.3kg/m2; 1–6 procedures per patient) were treated with 53 CS-PHPs. All patients received cross-sectional imaging for initial and follow-up examinations. Baseline tumor load, extrahepatic tumor load, tumor response, PFS, and OS were assessed. Non-parametric statistics were used. Results: After the initial CS-PHP, a partial response was observed in 11 patients (41%), stable disease in 12 patients (44%) and progressive disease in 4 patients (15%); two patients died before the response was evaluated. After initial CS-PHP, median OS was 12.9 ± 7.4 months and median PFS was 7.1 ± 7.4 months. OS after one year was 50%. After the second CS-PHP, median PFS was 7.9 ± 5.7 months. Seven patients had a liver tumor burden >25%, associated with a significantly shorter OS (6.0 ± 2.4 vs. 14.1 ± 12.7 months; P = 0.008). At the time of first CS-PHP, 41% (12/29) of the patients had extrahepatic metastases that did not affect OS (11.1 ± 8.4 months vs. 12.9 ± 13.6 months; P = 0.66). Conclusion: CS-PHP is a safe and effective treatment for the hepatic metastatic uveal melanoma, especially for patients with a hepatic tumor burden <25%.
- 2 February 2021
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 56 (7) , 465-470
Image Quality Improvement of Dynamic Contrast-Enhanced Gradient Echo Magnetic Resonance Imaging by Iterative Denoising and Edge Enhancement
Objectives The aim of this study was to investigate the impact of a novel edge enhancement and iterative denoising algorithm in 1.5-T T1-weighted dynamic contrast-enhanced (DCE) gradient echo (GRE) magnetic resonance imaging of the abdomen on image quality, noise levels, diagnostic confidence, and lesion detectability. Materials and Methods Fifty patients who underwent a clinically indicated magnetic resonance imaging with DCE imaging of the abdomen between June and August 2020 were included in this retrospective, monocentric, institutional review board–approved study. For DCE imaging, a series of 3 volume interpolated breath-hold examinations (VIBEs) was performed. The raw data of all DCE imaging studies were processed twice, once using standard reconstruction (DCES) and again using an edge enhancement and iterative denoising approach (DCEDE). All imaging studies were randomly reviewed by 2 radiologists independently regarding noise levels, arterial contrast, sharpness of vessels, overall image quality, and diagnostic confidence using a Likert scale ranging from 1 to 4, with 4 being the best. Furthermore, lesion detectability was evaluated using the same ranking system. Results All 50 imaging studies were successfully reconstructed with both methods. Interreader agreement (Cohen κ) was substantial to perfect for both readers. Arterial contrast and sharpness of vessels were rated superior by both readers with a median of 4 in DCEDE versus a median of 3 in DCES (P < 0.001). Furthermore, noise levels as well as overall image quality were rated higher with a median of 4 in DCEDE compared with a median of 3 in DCES (P < 0.001). Lesion detectability was evaluated to be superior in DCEDE with a median of 4 versus DCES with a median of 3 (P < 0.001). Consequently, diagnostic confidence was also rated to be superior in DCEDE with a median of 4 versus DCES with a median of 3 (P < 0.001). Conclusions Iterative denoising and edge enhancement are feasible in DCE imaging of the abdomen providing superior arterial contrast, noise levels, and overall image quality. Furthermore, lesion detectability and diagnostic confidence were significantly improved using this novel reconstruction method. Further reduction of acquisition time might be possible via reduction of increased noise levels using this presented method.
- 2 February 2021
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 56 (7) , 465-470
Image Quality Improvement of Dynamic Contrast-Enhanced Gradient Echo Magnetic Resonance Imaging by Iterative Denoising and Edge Enhancement
Objectives The aim of this study was to investigate the impact of a novel edge enhancement and iterative denoising algorithm in 1.5-T T1-weighted dynamic contrast-enhanced (DCE) gradient echo (GRE) magnetic resonance imaging of the abdomen on image quality, noise levels, diagnostic confidence, and lesion detectability. Materials and Methods Fifty patients who underwent a clinically indicated magnetic resonance imaging with DCE imaging of the abdomen between June and August 2020 were included in this retrospective, monocentric, institutional review board–approved study. For DCE imaging, a series of 3 volume interpolated breath-hold examinations (VIBEs) was performed. The raw data of all DCE imaging studies were processed twice, once using standard reconstruction (DCES) and again using an edge enhancement and iterative denoising approach (DCEDE). All imaging studies were randomly reviewed by 2 radiologists independently regarding noise levels, arterial contrast, sharpness of vessels, overall image quality, and diagnostic confidence using a Likert scale ranging from 1 to 4, with 4 being the best. Furthermore, lesion detectability was evaluated using the same ranking system. Results All 50 imaging studies were successfully reconstructed with both methods. Interreader agreement (Cohen κ) was substantial to perfect for both readers. Arterial contrast and sharpness of vessels were rated superior by both readers with a median of 4 in DCEDE versus a median of 3 in DCES (P < 0.001). Furthermore, noise levels as well as overall image quality were rated higher with a median of 4 in DCEDE compared with a median of 3 in DCES (P < 0.001). Lesion detectability was evaluated to be superior in DCEDE with a median of 4 versus DCES with a median of 3 (P < 0.001). Consequently, diagnostic confidence was also rated to be superior in DCEDE with a median of 4 versus DCES with a median of 3 (P < 0.001). Conclusions Iterative denoising and edge enhancement are feasible in DCE imaging of the abdomen providing superior arterial contrast, noise levels, and overall image quality. Furthermore, lesion detectability and diagnostic confidence were significantly improved using this novel reconstruction method. Further reduction of acquisition time might be possible via reduction of increased noise levels using this presented method.
- Open Access
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 1401-1408
MRI-guided percutaneous thermoablation as first-line treatment of recurrent hepatic malignancies following hepatic resection: single center long-term experience
Hepatic recurrence of liver malignancies is a leading problem in patients after liver resection with curative intention. Thermoablation is a promising treatment approach for patients after hepatic resection, especially in liver-limited conditions. This study aimed to investigate safety, survival, and local tumor control rates of MRI-guided percutaneous thermoablation of recurrent hepatic malignancies following hepatic resection. Data from patients with primary or secondary hepatic malignancies treated between 2004 and 2018 with MRI-guided percutaneous thermoablation of hepatic recurrence after prior hepatic resection were retrospectively analyzed. Disease-free survival and overall survival rates were calculated using the Kaplan-Meier method. A total of 57 patients with hepatic recurrence (mean tumor size = 18.9 ± 9.1 mm) of colorectal cancer liver metastases (n = 27), hepatocellular carcinoma (n = 17), intrahepatic recurrence of cholangiocellular carcinoma (n = 9), or other primary malignant tumor entities (n = 4) were treated once or several times with MR-guided percutaneous radiofrequency (n = 52) or microwave ablation (n = 5) (range: 1–4 times). Disease progression occurred due to local recurrence at the ablation site in nine patients (15.8%), non-local hepatic recurrence in 33 patients (57.9%), and distant malignancy in 18 patients (31.6%). The median overall survival for the total cohort was 40 months and 49 months for the colorectal cancer group, with a 5-year overall survival rate of 40.7 and 42.5%, respectively. The median disease-free survival was 10 months for both the total cohort and the colorectal cancer group with a 5-year disease-free survival rate of 15.1 and 14.8%, respectively. The mean follow-up time was 39.6 ± 35.7 months. MR-guided thermoablation is an effective and safe approach in the treatment of hepatic recurrences in liver-limited conditions and can achieve long-term survival.
- 1 January 2021
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 38 (1) , 1401-1408
Open AccessMRI-guided percutaneous thermoablation as first-line treatment of recurrent hepatic malignancies following hepatic resection: single center long-term experience
Hepatic recurrence of liver malignancies is a leading problem in patients after liver resection with curative intention. Thermoablation is a promising treatment approach for patients after hepatic resection, especially in liver-limited conditions. This study aimed to investigate safety, survival, and local tumor control rates of MRI-guided percutaneous thermoablation of recurrent hepatic malignancies following hepatic resection. Data from patients with primary or secondary hepatic malignancies treated between 2004 and 2018 with MRI-guided percutaneous thermoablation of hepatic recurrence after prior hepatic resection were retrospectively analyzed. Disease-free survival and overall survival rates were calculated using the Kaplan-Meier method. A total of 57 patients with hepatic recurrence (mean tumor size = 18.9 ± 9.1 mm) of colorectal cancer liver metastases (n = 27), hepatocellular carcinoma (n = 17), intrahepatic recurrence of cholangiocellular carcinoma (n = 9), or other primary malignant tumor entities (n = 4) were treated once or several times with MR-guided percutaneous radiofrequency (n = 52) or microwave ablation (n = 5) (range: 1–4 times). Disease progression occurred due to local recurrence at the ablation site in nine patients (15.8%), non-local hepatic recurrence in 33 patients (57.9%), and distant malignancy in 18 patients (31.6%). The median overall survival for the total cohort was 40 months and 49 months for the colorectal cancer group, with a 5-year overall survival rate of 40.7 and 42.5%, respectively. The median disease-free survival was 10 months for both the total cohort and the colorectal cancer group with a 5-year disease-free survival rate of 15.1 and 14.8%, respectively. The mean follow-up time was 39.6 ± 35.7 months. MR-guided thermoablation is an effective and safe approach in the treatment of hepatic recurrences in liver-limited conditions and can achieve long-term survival.
- Open Access
- 22 July 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (11) , 1631-1638
MR-Guided High-Power Microwave Ablation in Hepatic Malignancies: Initial Results in Clinical Routine
Purpose: Evaluation of technique effectiveness, patient safety and ablation parameters of MR-guided microwave ablation in hepatic malignancies using an MR-conditional high-power microwave ablation system. Materials and Methods: Institutional review board approval and informed patient consent were obtained. Patients who underwent MR-guided microwave ablation of hepatic malignancies in a 1.5T wide-bore scanner using a perfusion-cooled high-power microwave ablation system with a maximum generator power of 150 W were included. Ablation parameters comprising procedure durations, net ablation duration, applicator positions and ablation zone dimensions were recorded. Adverse events were classified according to the CIRSE classification system. Technique effectiveness was assessed after 1 month. Follow-up was conducted with contrast-enhanced MRI and ranged from 1 to 20 months (mean: 6.1 ± 5.4 months). Results: Twenty-one consecutive patients (age: 63.4 ± 10.5 years; 5 female) underwent 22 procedures for 28 tumours (9 hepatocellular carcinomas, 19 metastases) with a mean tumour diameter of 14.6 ± 5.4 mm (range: 6–24 mm). Technique effectiveness was achieved in all lesions. Tumours were treated using 1.7 ± 0.7 applicator positions (range: 1–3). Mean energy and ablation duration per tumour were 75.3 ± 35.4 kJ and 13.3 ± 6.2 min, respectively. Coagulation zone short- and long-axis diameters were 29.1 ± 6.4 mm and 39.9 ± 7.4 mm, respectively. Average procedure duration was 146.4 ± 26.2 min (range: 98–187 min). One minor complication was reported. Five patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed during initial follow-up. Conclusion: MR-guided high-power microwave ablation provides safe and effective treatment of hepatic malignancies with short ablation times and within acceptable procedure durations.
- 22 July 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (11) , 1631-1638
Open AccessMR-Guided High-Power Microwave Ablation in Hepatic Malignancies: Initial Results in Clinical Routine
Purpose: Evaluation of technique effectiveness, patient safety and ablation parameters of MR-guided microwave ablation in hepatic malignancies using an MR-conditional high-power microwave ablation system. Materials and Methods: Institutional review board approval and informed patient consent were obtained. Patients who underwent MR-guided microwave ablation of hepatic malignancies in a 1.5T wide-bore scanner using a perfusion-cooled high-power microwave ablation system with a maximum generator power of 150 W were included. Ablation parameters comprising procedure durations, net ablation duration, applicator positions and ablation zone dimensions were recorded. Adverse events were classified according to the CIRSE classification system. Technique effectiveness was assessed after 1 month. Follow-up was conducted with contrast-enhanced MRI and ranged from 1 to 20 months (mean: 6.1 ± 5.4 months). Results: Twenty-one consecutive patients (age: 63.4 ± 10.5 years; 5 female) underwent 22 procedures for 28 tumours (9 hepatocellular carcinomas, 19 metastases) with a mean tumour diameter of 14.6 ± 5.4 mm (range: 6–24 mm). Technique effectiveness was achieved in all lesions. Tumours were treated using 1.7 ± 0.7 applicator positions (range: 1–3). Mean energy and ablation duration per tumour were 75.3 ± 35.4 kJ and 13.3 ± 6.2 min, respectively. Coagulation zone short- and long-axis diameters were 29.1 ± 6.4 mm and 39.9 ± 7.4 mm, respectively. Average procedure duration was 146.4 ± 26.2 min (range: 98–187 min). One minor complication was reported. Five patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed during initial follow-up. Conclusion: MR-guided high-power microwave ablation provides safe and effective treatment of hepatic malignancies with short ablation times and within acceptable procedure durations.
- 24 February 2020
- Published by Georg Thieme Verlag KG in Onkologie up2date
- Vol. 2 (01) , 9-15
Radiofrequenz- und Mikrowellen-Ablation von Lebertumoren – Schritt für Schritt
Die lokale Tumortherapie mittels Thermoablation ist eine wichtige Therapieoption in der Behandlung von primären und sekundären Lebertumoren. Insbesondere die Radiofrequenz-Ablation (RFA) und die Mikrowellen-Ablation (MWA) sind weitverbreitete und effektive Techniken – ihre Anwendung wird in diesem Artikel beschrieben.
- 24 February 2020
- Published by Georg Thieme Verlag KG in Onkologie up2date
- Vol. 2 (01) , 9-15
Radiofrequenz- und Mikrowellen-Ablation von Lebertumoren – Schritt für Schritt
Die lokale Tumortherapie mittels Thermoablation ist eine wichtige Therapieoption in der Behandlung von primären und sekundären Lebertumoren. Insbesondere die Radiofrequenz-Ablation (RFA) und die Mikrowellen-Ablation (MWA) sind weitverbreitete und effektive Techniken – ihre Anwendung wird in diesem Artikel beschrieben.
- Open Access
- 23 September 2019
- Published by Springer Nature in European Radiology Experimental
- Vol. 3 (1) , 1-9
Artefact and ablation performance of an MR-conditional high-power microwave system in bovine livers: an ex vivo study
Background: We evaluated a magnetic resonance (MR)-conditional high-power microwave ablation system. Methods: An exvivo 1.5-T evaluation was conducted by varying the sequence (T1-weighted volume interpolated breath-hold examination, T1w-VIBE; T1-weighted fast low-angle shot, T1w-FLASH; T2-weighted turbo spin-echo, T2w-TSE), applicator angulation to B0 (A-to-B0), slice orientation, and encoding direction. Tip location error (TLE) and artefact diameters were measured, and influence of imaging parameters was assessed with analysis of variance and post hoc testing. Twenty-four exvivo ablations were conducted in three bovine livers at 80 W and 120 W. Ablation durations were 5, 10, and 15 min. Ablation zones were compared for short-axis diameter (SAD), volume, and sphericity index (SI) with unpaired t test. Results: The artefact pattern was similar for all sequences. The shaft artefact (4.4 ± 2.9 mm, mean ± standard deviation) was dependent on the sequence (p = 0.012) and the A-to-B0 (p < 0.001); the largest shaft diameter was measured with T1w-FLASH (6.3 ± 3.4 mm) and with perpendicular A-to-B0 (6.7 ± 2.4 mm). The tip artefact (1.6 ± 0.7 mm) was dependent on A-to-B0 (p = 0.001); TLE was -2.6 ± 1.0 mm. Ablation results at the maximum setting (15 min, 120 W) were SAD = 42.0 ± 1.41 mm; volume = 56.78 ± 3.08 cm3, SI = 0.68 ± 0.05. In all ablations, SI ranged 0.68–0.75 with the smallest SI at 15 min and 120 W (p = 0.048). Conclusion: The system produced sufficiently large ablation zones and the artefact was appropriate for MR-guided interventions.
- 23 September 2019
- Published by Springer Nature in European Radiology Experimental
- Vol. 3 (1) , 1-9
Open AccessArtefact and ablation performance of an MR-conditional high-power microwave system in bovine livers: an ex vivo study
Background: We evaluated a magnetic resonance (MR)-conditional high-power microwave ablation system. Methods: An exvivo 1.5-T evaluation was conducted by varying the sequence (T1-weighted volume interpolated breath-hold examination, T1w-VIBE; T1-weighted fast low-angle shot, T1w-FLASH; T2-weighted turbo spin-echo, T2w-TSE), applicator angulation to B0 (A-to-B0), slice orientation, and encoding direction. Tip location error (TLE) and artefact diameters were measured, and influence of imaging parameters was assessed with analysis of variance and post hoc testing. Twenty-four exvivo ablations were conducted in three bovine livers at 80 W and 120 W. Ablation durations were 5, 10, and 15 min. Ablation zones were compared for short-axis diameter (SAD), volume, and sphericity index (SI) with unpaired t test. Results: The artefact pattern was similar for all sequences. The shaft artefact (4.4 ± 2.9 mm, mean ± standard deviation) was dependent on the sequence (p = 0.012) and the A-to-B0 (p < 0.001); the largest shaft diameter was measured with T1w-FLASH (6.3 ± 3.4 mm) and with perpendicular A-to-B0 (6.7 ± 2.4 mm). The tip artefact (1.6 ± 0.7 mm) was dependent on A-to-B0 (p = 0.001); TLE was -2.6 ± 1.0 mm. Ablation results at the maximum setting (15 min, 120 W) were SAD = 42.0 ± 1.41 mm; volume = 56.78 ± 3.08 cm3, SI = 0.68 ± 0.05. In all ablations, SI ranged 0.68–0.75 with the smallest SI at 15 min and 120 W (p = 0.048). Conclusion: The system produced sufficiently large ablation zones and the artefact was appropriate for MR-guided interventions.
- 6 June 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1100) , 20180835
Local treatment of oligometastatic disease: current role
The presence of distant metastases has long been a predictor of poor outcome in solid cancer. However, in an oncologic situation called oligometastatic disease (OMD), multiple studies have revealed a survival benefit with aggressive treatment of these metastases. Besides surgery and radiation therapy, local thermal therapies have developed into a treatment option for OMD. Most studies concerning local therapy of OMD are available for colorectal cancer, which is therefore the focus of this article. Furthermore, this review gives a basic overview of the most popular ablation techniques for treatment of OMD.
- 6 June 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1100) , 20180835
Local treatment of oligometastatic disease: current role
The presence of distant metastases has long been a predictor of poor outcome in solid cancer. However, in an oncologic situation called oligometastatic disease (OMD), multiple studies have revealed a survival benefit with aggressive treatment of these metastases. Besides surgery and radiation therapy, local thermal therapies have developed into a treatment option for OMD. Most studies concerning local therapy of OMD are available for colorectal cancer, which is therefore the focus of this article. Furthermore, this review gives a basic overview of the most popular ablation techniques for treatment of OMD.
- Open Access
- 30 May 2019
- Published by Springer Nature in Cancer Imaging
- Vol. 19 (1) , 1-8
Chemosaturation with percutaneous hepatic perfusion of melphalan for liver-dominant metastatic uveal melanoma: a single center experience
To investigate the outcome and safety data of chemosaturation with percutaneous hepatic perfusion (CS-PHP) of melphalan in patients with liver-dominant metastatic uveal melanoma. This is a HIPAA compliant, IRB approved, retrospective study. A total of 28 CS-PHPs were performed in 16 individual patients (six men and ten women, median age 63.1 years [range 49.1 to 78.7 years], one to six CS-PHP procedures per patient) for treatment of liver-dominant metastatic uveal melanoma between June, 2015 and December, 2018. All patients received cross-sectional imaging at baseline and during follow-up. CS-PHP was performed with the Hepatic CHEMOSAT® Delivery System (Delcath Systems, Inc., NY, USA) facilitating extracorporeal filtration of hepatic blood for melphalan removal. Ideal body weight-adjusted melphalan doses were administered into the hepatic arteries. Serious adverse events (SAE), progression-free survival based on response criteria in solid tumors, and overall survival were noted. Survival data were analyzed using Kaplan-Meier estimates. Partial response after first CS-PHP was observed in nine patients (60%), stable disease in five patients (33%) and progressive disease in one patient (7%). Median overall survival was 27.4 months (95% CI 4.1 to 35.4 month) after first CS-PHP. Median progression-free survival was 11.1 months after first CS-PHP (95% CI 4.9 to 23.6 months). SAEs were observed in the majority of patients with most SAEs limited to grades one and two. Thirteen SAEs of grades three and four were observed in seven individual patients. No grade five SAE was observed. CS-PHP is an efficacious and safe treatment for patients presenting with liver-dominant metastatic uveal melanoma.
- 30 May 2019
- Published by Springer Nature in Cancer Imaging
- Vol. 19 (1) , 1-8
Open AccessChemosaturation with percutaneous hepatic perfusion of melphalan for liver-dominant metastatic uveal melanoma: a single center experience
To investigate the outcome and safety data of chemosaturation with percutaneous hepatic perfusion (CS-PHP) of melphalan in patients with liver-dominant metastatic uveal melanoma. This is a HIPAA compliant, IRB approved, retrospective study. A total of 28 CS-PHPs were performed in 16 individual patients (six men and ten women, median age 63.1 years [range 49.1 to 78.7 years], one to six CS-PHP procedures per patient) for treatment of liver-dominant metastatic uveal melanoma between June, 2015 and December, 2018. All patients received cross-sectional imaging at baseline and during follow-up. CS-PHP was performed with the Hepatic CHEMOSAT® Delivery System (Delcath Systems, Inc., NY, USA) facilitating extracorporeal filtration of hepatic blood for melphalan removal. Ideal body weight-adjusted melphalan doses were administered into the hepatic arteries. Serious adverse events (SAE), progression-free survival based on response criteria in solid tumors, and overall survival were noted. Survival data were analyzed using Kaplan-Meier estimates. Partial response after first CS-PHP was observed in nine patients (60%), stable disease in five patients (33%) and progressive disease in one patient (7%). Median overall survival was 27.4 months (95% CI 4.1 to 35.4 month) after first CS-PHP. Median progression-free survival was 11.1 months after first CS-PHP (95% CI 4.9 to 23.6 months). SAEs were observed in the majority of patients with most SAEs limited to grades one and two. Thirteen SAEs of grades three and four were observed in seven individual patients. No grade five SAE was observed. CS-PHP is an efficacious and safe treatment for patients presenting with liver-dominant metastatic uveal melanoma.