Haleh Nazemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haleh Nazemi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Arezoo Emadi
University of Windsor
19 shared publications - Yumna Birjis
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON N9B 3P4, Canada
7 shared publications - Gian Carlo Antony Raj
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON, Canada
4 shared publications - Muhammad Umair Nathani
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON N9B 3P4, Canada
4 shared publications - Pavithra Munirathinam
University of Windsor
4 shared publications - Aya Abu-Libdeh
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON, Canada
3 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (9) , 1501604
Enhanced Gravimetric Sensitivity of Capacitive MEMS Resonators via Geometric Design Modification
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (9) , 1501604
Enhanced Gravimetric Sensitivity of Capacitive MEMS Resonators via Geometric Design Modification
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (1) , 569-578
Dual-Frequency Square PMUT With Enhanced Transmission Efficiency at Fundamental and Higher Modes
This work presents the design, fabrication, and characterization of a dual-frequency square piezoelectric micromachined ultrasonic transducer (PMUT) featuring a novel dual top electrode architecture that, for the first time, combines a circular inner and square outer ring electrode, enabling enhanced mode-selective excitation. The electrode topology is strategically aligned with the spatial strain distributions of both the fundamental (1.7 MHz) and higher order (6.4 MHz) flexural modes, enabling efficient and selective excitation of each mode within a single PMUT structure. Unlike conventional single-electrode PMUTs, which are typically limited to strong performance at the fundamental resonance, the proposed design achieves enhanced transmission efficiency at both operating modes. Finite element simulations and experimental validation demonstrate significant improvements in electromechanical coupling, with a twofold increase at the higher order mode, as well as enhancements in transmit sensitivity by 36% at the fundamental mode and by a factor of five at the higher order mode, compared to a conventional single top electrode PMUT. Underwater acoustic characterization further confirms dual-mode operation of the proposed SqC PMUT, demonstrating a 68% increase in acoustic pressure at the higher order mode compared to the reference single-electrode PMUT. This dual-mode enhancement allows the higher order resonance to serve as an additional operating frequency, facilitating dual-frequency operation without increasing device complexity or fabrication steps. The proposed PMUT architecture offers a compact and high-performance solution for ultrasonic imaging and sensing applications.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (1) , 569-578
Dual-Frequency Square PMUT With Enhanced Transmission Efficiency at Fundamental and Higher Modes
This work presents the design, fabrication, and characterization of a dual-frequency square piezoelectric micromachined ultrasonic transducer (PMUT) featuring a novel dual top electrode architecture that, for the first time, combines a circular inner and square outer ring electrode, enabling enhanced mode-selective excitation. The electrode topology is strategically aligned with the spatial strain distributions of both the fundamental (1.7 MHz) and higher order (6.4 MHz) flexural modes, enabling efficient and selective excitation of each mode within a single PMUT structure. Unlike conventional single-electrode PMUTs, which are typically limited to strong performance at the fundamental resonance, the proposed design achieves enhanced transmission efficiency at both operating modes. Finite element simulations and experimental validation demonstrate significant improvements in electromechanical coupling, with a twofold increase at the higher order mode, as well as enhancements in transmit sensitivity by 36% at the fundamental mode and by a factor of five at the higher order mode, compared to a conventional single top electrode PMUT. Underwater acoustic characterization further confirms dual-mode operation of the proposed SqC PMUT, demonstrating a 68% increase in acoustic pressure at the higher order mode compared to the reference single-electrode PMUT. This dual-mode enhancement allows the higher order resonance to serve as an additional operating frequency, facilitating dual-frequency operation without increasing device complexity or fabrication steps. The proposed PMUT architecture offers a compact and high-performance solution for ultrasonic imaging and sensing applications.
- 29 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 35 (1) , 153-162
Mode-Selective Electrode Configuration for Multifrequency Operation in PMUTs: Microfabrication and Characterization
Multi-frequency operation in ultrasonic transducers balances the trade-off between resolution and penetration depth in ultrasonic imaging. Single top-electrode PMUTs couple strongly to the fundamental mode but weakly to higher-order modes because uniform electrode coverage does not conform to the higher-mode strain profile. Dual concentric ring-and-disk (C–C) electrodes access multiple modes yet reduce fundamental-mode coupling due to misalignment between the segmented coverage and the fundamental strain profile. In this work a circular square (C-Sq) dual top electrode is introduced to strengthen coupling in both the fundamental and higher order modes for multifrequency operation. The configuration pairs a circular outer electrode with a square inner electrode on a circular membrane. The topology aligns with the strain profiles of the fundamental and a selected higher mode enabling mode selective excitation by electrode switching. The proposed C-Sq dual electrode design and reference single electrode and dual electrode concentric ring and disk (C-C) devices were fabricated using the PiezoMUMPs multi-user MEMS process for fair comparison. Electrical impedance analysis, laser doppler vibrometry, and acoustic measurements show a 37% increase in fundamental mode electromechanical coupling relative to C-C dual electrode PMUT and a 27% improvement for the higher mode relative to single electrode PMUTs. Membrane displacement increases by 67% and acoustic pressure at the fundamental resonance is enhanced by 13%. The proposed C-Sq PMUT supports efficient, mode selective multifrequency operation for biomedical imaging and sensing.[2025-0152]
- 29 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 35 (1) , 153-162
Mode-Selective Electrode Configuration for Multifrequency Operation in PMUTs: Microfabrication and Characterization
Multi-frequency operation in ultrasonic transducers balances the trade-off between resolution and penetration depth in ultrasonic imaging. Single top-electrode PMUTs couple strongly to the fundamental mode but weakly to higher-order modes because uniform electrode coverage does not conform to the higher-mode strain profile. Dual concentric ring-and-disk (C–C) electrodes access multiple modes yet reduce fundamental-mode coupling due to misalignment between the segmented coverage and the fundamental strain profile. In this work a circular square (C-Sq) dual top electrode is introduced to strengthen coupling in both the fundamental and higher order modes for multifrequency operation. The configuration pairs a circular outer electrode with a square inner electrode on a circular membrane. The topology aligns with the strain profiles of the fundamental and a selected higher mode enabling mode selective excitation by electrode switching. The proposed C-Sq dual electrode design and reference single electrode and dual electrode concentric ring and disk (C-C) devices were fabricated using the PiezoMUMPs multi-user MEMS process for fair comparison. Electrical impedance analysis, laser doppler vibrometry, and acoustic measurements show a 37% increase in fundamental mode electromechanical coupling relative to C-C dual electrode PMUT and a 27% improvement for the higher mode relative to single electrode PMUTs. Membrane displacement increases by 67% and acoustic pressure at the fundamental resonance is enhanced by 13%. The proposed C-Sq PMUT supports efficient, mode selective multifrequency operation for biomedical imaging and sensing.[2025-0152]
- Open Access
- 21 October 2025
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 14 (2) , 219-225
Development and analysis of microbridge resonators for reduced pull-in voltage and preserved resonant frequency
This study presents a novel design methodology for microbridge resonators aimed at reducing pull-in voltage while maintaining resonant frequency. Previous studies have primarily focused on adjusting resonator plate geometry, modifying anchor conditions, or altering material properties to control pull-in voltage. In contrast, this work introduces the ratio of the bottom electrode length to the microbridge length as a critical and tunable design parameter, which has remained unexplored in previous studies. An analytical model is developed to capture the effects of this ratio, and its predictions are validated through finite element analysis. To demonstrate the concept, two microbridges are designed and fabricated with bottom electrode lengths of 42 and 82 µm, corresponding to 35 % and 68 % of the microbridge length, respectively. All other design parameters, such as plate thickness, material properties and cavity height, are kept constant to enable a fair comparison. Electrical characterizations confirm that increasing the bottom electrode-to-microbridge length ratio effectively lowers the pull-in voltage without degrading resonator performance. Results show a 16 % reduction in pull-in voltage when the bottom electrode length is 68 % of the microbridge length, demonstrating the feasibility and advantages of the proposed methodology over existing techniques.
- 21 October 2025
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 14 (2) , 219-225
Open AccessDevelopment and analysis of microbridge resonators for reduced pull-in voltage and preserved resonant frequency
This study presents a novel design methodology for microbridge resonators aimed at reducing pull-in voltage while maintaining resonant frequency. Previous studies have primarily focused on adjusting resonator plate geometry, modifying anchor conditions, or altering material properties to control pull-in voltage. In contrast, this work introduces the ratio of the bottom electrode length to the microbridge length as a critical and tunable design parameter, which has remained unexplored in previous studies. An analytical model is developed to capture the effects of this ratio, and its predictions are validated through finite element analysis. To demonstrate the concept, two microbridges are designed and fabricated with bottom electrode lengths of 42 and 82 µm, corresponding to 35 % and 68 % of the microbridge length, respectively. All other design parameters, such as plate thickness, material properties and cavity height, are kept constant to enable a fair comparison. Electrical characterizations confirm that increasing the bottom electrode-to-microbridge length ratio effectively lowers the pull-in voltage without degrading resonator performance. Results show a 16 % reduction in pull-in voltage when the bottom electrode length is 68 % of the microbridge length, demonstrating the feasibility and advantages of the proposed methodology over existing techniques.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. PP, 1-4
DISTRIBUTION OF THE CLAMPED BOUNDARY AND ITS IMPACT ON RESONATOR PERFORMANCE
Capacitive resonator performance including sensitivity is determined by its capacitive change and resonant frequency shift in response to an external perturbation such as added mass. Conventional designs are inherently defined by fully clamped boundaries around the deflectable plate. However, recent advances suggest that bilateral and quadrilateral concentric boundary resonators can offer improved performance through enhanced deflection compared to conventional fully clamped resonators. This work analyses how the spatial distribution of clamped boundaries under identical total clamped angles affects key resonator metrics including sensitivity, which is manifested through change in capacitance and frequency shift in electrical characterization. Resonators with bilateral and quadrilateral clamped boundary configurations are the focus of this work to demonstrate the idea. In order to do this, resonators with total clamped angles of 120°, 180°, and 240° are fabricated and characterized using electrical impedance analysis, with results in agreement with the conducted finite element analysis. The quadrilateral configurations outperformed bilateral ones in both frequency shift and capacitance change, indicating that clamped boundary distribution serves as a critical design parameter. These findings offer new insight into structural optimization strategies for capacitive resonators beyond conventional clamping schemes.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. PP, 1-4
DISTRIBUTION OF THE CLAMPED BOUNDARY AND ITS IMPACT ON RESONATOR PERFORMANCE
Capacitive resonator performance including sensitivity is determined by its capacitive change and resonant frequency shift in response to an external perturbation such as added mass. Conventional designs are inherently defined by fully clamped boundaries around the deflectable plate. However, recent advances suggest that bilateral and quadrilateral concentric boundary resonators can offer improved performance through enhanced deflection compared to conventional fully clamped resonators. This work analyses how the spatial distribution of clamped boundaries under identical total clamped angles affects key resonator metrics including sensitivity, which is manifested through change in capacitance and frequency shift in electrical characterization. Resonators with bilateral and quadrilateral clamped boundary configurations are the focus of this work to demonstrate the idea. In order to do this, resonators with total clamped angles of 120°, 180°, and 240° are fabricated and characterized using electrical impedance analysis, with results in agreement with the conducted finite element analysis. The quadrilateral configurations outperformed bilateral ones in both frequency shift and capacitance change, indicating that clamped boundary distribution serves as a critical design parameter. These findings offer new insight into structural optimization strategies for capacitive resonators beyond conventional clamping schemes.
- Open Access
Polymer-Based Chemicapacitive Hybrid Sensor Array for Improved Selectivity in e-Nose Systems
Detecting volatile organic compounds (VOCs) is essential for health, environmental protection, and industrial safety. VOCs contribute to air pollution, pose health risks, and can indicate leaks or contamination in industries. Applications include air quality monitoring, disease diagnosis, and food safety. This paper focuses on polymer-based hybrid sensor arrays (HSAs) utilizing interdigitated electrode (IDE) geometries for VOC detection. Achieving high selectivity and sensitivity in gas sensing remains a challenge, particularly in complex environments. To address this, we propose HSAs as an innovative solution to enhance sensor performance. IDE-based sensors are designed and fabricated using the Polysilicon Multi-User MEMS process (PolyMUMPs). Experimental evaluations are performed by exposing sensors to VOCs under controlled conditions. Traditional multi-sensor arrays (MSAs) achieve 82% prediction accuracy, while virtual sensor arrays (VSAs) leveraging frequency dependence improve performance: PMMA-VSA and PVP-VSA predict compounds with 100% and 98% accuracy, respectively. The proposed HSA, integrating these VSAs, consistently achieves 100% accuracy in compound identification and concentration estimation, surpassing MSA and VSA performance. These findings demonstrate that proposed polymer-based HSAs and VSAs, particularly with advanced IDE geometries, significantly enhance selectivity and sensitivity, advancing e-Nose technology for more accurate and reliable VOC detection across diverse applications.
Open AccessPolymer-Based Chemicapacitive Hybrid Sensor Array for Improved Selectivity in e-Nose Systems
Detecting volatile organic compounds (VOCs) is essential for health, environmental protection, and industrial safety. VOCs contribute to air pollution, pose health risks, and can indicate leaks or contamination in industries. Applications include air quality monitoring, disease diagnosis, and food safety. This paper focuses on polymer-based hybrid sensor arrays (HSAs) utilizing interdigitated electrode (IDE) geometries for VOC detection. Achieving high selectivity and sensitivity in gas sensing remains a challenge, particularly in complex environments. To address this, we propose HSAs as an innovative solution to enhance sensor performance. IDE-based sensors are designed and fabricated using the Polysilicon Multi-User MEMS process (PolyMUMPs). Experimental evaluations are performed by exposing sensors to VOCs under controlled conditions. Traditional multi-sensor arrays (MSAs) achieve 82% prediction accuracy, while virtual sensor arrays (VSAs) leveraging frequency dependence improve performance: PMMA-VSA and PVP-VSA predict compounds with 100% and 98% accuracy, respectively. The proposed HSA, integrating these VSAs, consistently achieves 100% accuracy in compound identification and concentration estimation, surpassing MSA and VSA performance. These findings demonstrate that proposed polymer-based HSAs and VSAs, particularly with advanced IDE geometries, significantly enhance selectivity and sensitivity, advancing e-Nose technology for more accurate and reliable VOC detection across diverse applications.
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (14) , 26499-26506
Design, Fabrication, and Characterization of Dual-Electrode Piezoelectric Micromachined Ultrasonic Transducer (PMUT) Geometries
Piezoelectric micromachined ultrasonic transducers (PMUTs) traditionally operate at a single frequency, requiring physical modifications to alter their operational frequency. In ultrasonic applications such as diagnostic imaging, the working frequency is critical in determining resolution and detection range. Dual-electrode PMUTs present a promising alternative to conventional designs, enabling multi-frequency operation by activating distinct resonant modes through tailored electrode configurations and actuations. This study details the design, fabrication, and characterization of three dual-electrode PMUT geometries: circular, square, and rectangular membranes. Fabricated using the PiezoMUMPs process, these geometries feature identical material properties and membrane areas. Their electromechanical performance was evaluated through finite element simulations and experimental methods, focusing on metrics such as electromechanical coupling coefficient (EMCC), resonant frequencies, and membrane displacement. A comparative performance analysis across the geometries is presented. Multi-frequency operation was achieved using a dual-electrode configuration with an outer ring electrode and an inner disk electrode, allowing independent activation of two resonant modes. These findings highlight the potential of dual-electrode PMUTs to enhance multi-frequency operation, especially in ultrasonic imaging and related applications.
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (14) , 26499-26506
Design, Fabrication, and Characterization of Dual-Electrode Piezoelectric Micromachined Ultrasonic Transducer (PMUT) Geometries
Piezoelectric micromachined ultrasonic transducers (PMUTs) traditionally operate at a single frequency, requiring physical modifications to alter their operational frequency. In ultrasonic applications such as diagnostic imaging, the working frequency is critical in determining resolution and detection range. Dual-electrode PMUTs present a promising alternative to conventional designs, enabling multi-frequency operation by activating distinct resonant modes through tailored electrode configurations and actuations. This study details the design, fabrication, and characterization of three dual-electrode PMUT geometries: circular, square, and rectangular membranes. Fabricated using the PiezoMUMPs process, these geometries feature identical material properties and membrane areas. Their electromechanical performance was evaluated through finite element simulations and experimental methods, focusing on metrics such as electromechanical coupling coefficient (EMCC), resonant frequencies, and membrane displacement. A comparative performance analysis across the geometries is presented. Multi-frequency operation was achieved using a dual-electrode configuration with an outer ring electrode and an inner disk electrode, allowing independent activation of two resonant modes. These findings highlight the potential of dual-electrode PMUTs to enhance multi-frequency operation, especially in ultrasonic imaging and related applications.
- 29 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (12) , 7758-7764
Micromachined Capacitive Sensor With Configured Boundaries: Approach, Design and Fabrication
A new set of capacitive-based resonators is introduced in this work that utilizes a unique configured boundaries approach. The proposed design strategy is utilized to develop and characterize three circular resonators as proof-of-concept with strategically configured boundaries. For a fair comparison, the introduced novel resonators along with a reference conventional structure are fabricated using a commercially available fabrication technique, PolyMUMPs. The effects of the presented approach on plate deflection and electromechanical coupling coefficient are demonstrated through finite element analysis (FEA) using COMSOL Multiphysics as well as experimental characterizations. The fabricated devices are electrically evaluated. The white light interferometry is further used for deflection measurements. The device performance evaluations illustrate a robust control of the resonator’s plate stiffness and deflection while maintaining the same dimensions. Experimental evaluations demonstrate an enhanced deflection profile of the plate, which significantly increases the average deflection by up to 50% compared to the conventional resonator developed with the same dimensions and fabrication process. Furthermore, it is observed that using the proposed approach reduces the pull-in voltage by up to 17% compared to the conventional resonators while preserving the resonant frequency within $\pm$ 150 kHz.
- 29 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (12) , 7758-7764
Micromachined Capacitive Sensor With Configured Boundaries: Approach, Design and Fabrication
A new set of capacitive-based resonators is introduced in this work that utilizes a unique configured boundaries approach. The proposed design strategy is utilized to develop and characterize three circular resonators as proof-of-concept with strategically configured boundaries. For a fair comparison, the introduced novel resonators along with a reference conventional structure are fabricated using a commercially available fabrication technique, PolyMUMPs. The effects of the presented approach on plate deflection and electromechanical coupling coefficient are demonstrated through finite element analysis (FEA) using COMSOL Multiphysics as well as experimental characterizations. The fabricated devices are electrically evaluated. The white light interferometry is further used for deflection measurements. The device performance evaluations illustrate a robust control of the resonator’s plate stiffness and deflection while maintaining the same dimensions. Experimental evaluations demonstrate an enhanced deflection profile of the plate, which significantly increases the average deflection by up to 50% compared to the conventional resonator developed with the same dimensions and fabrication process. Furthermore, it is observed that using the proposed approach reduces the pull-in voltage by up to 17% compared to the conventional resonators while preserving the resonant frequency within $\pm$ 150 kHz.
- Open Access
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 156412-156419
Effect of Middle Membrane Dimensions on Dynamic Control Range in Dual Membrane Capacitive Micromachined Ultrasonic Transducers
Two sets of multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) are designed and fabricated for a range of middle membrane radii, from 35 – 49μm and 34 – 44μm. All other design parameters were kept identical within each set of experiments to enable a fair comparison. To study the dynamic control range of the designed M 3 -CMUTs, their performance was first evaluated through COMSOL simulation yielding results on the resonant frequency and corresponding cavity height. This was followed by fabrication of the same designs using multiuser microelectromechanical systems processes (MUMPs). The development of these prototypes enabled the comprehensive electrical characterization of the designs with responses that are demonstrated to be in full agreement with the simulation results. The middle membrane radii of the M 3 -CMUTs impact the collapse voltage of these devices in addition to the affecting the measured resonant frequencies when tested devices within the same measurement conditions. A 20kHz increase in resonant frequency shift was recorded when the middle membrane radius of these devices was increased from 7μm to 10μm while operating under a 20V top membrane bias and -3V to -5V middle membrane bias. These results demonstrate the expansion of the devices’ cavity heights beyond conventional capacitive micromachined transducers. These observations indicate that the middle membrane radius has influence on the dynamic control of effective cavity height in M 3 -CMUTs.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 156412-156419
Open AccessEffect of Middle Membrane Dimensions on Dynamic Control Range in Dual Membrane Capacitive Micromachined Ultrasonic Transducers
Two sets of multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) are designed and fabricated for a range of middle membrane radii, from 35 – 49μm and 34 – 44μm. All other design parameters were kept identical within each set of experiments to enable a fair comparison. To study the dynamic control range of the designed M 3 -CMUTs, their performance was first evaluated through COMSOL simulation yielding results on the resonant frequency and corresponding cavity height. This was followed by fabrication of the same designs using multiuser microelectromechanical systems processes (MUMPs). The development of these prototypes enabled the comprehensive electrical characterization of the designs with responses that are demonstrated to be in full agreement with the simulation results. The middle membrane radii of the M 3 -CMUTs impact the collapse voltage of these devices in addition to the affecting the measured resonant frequencies when tested devices within the same measurement conditions. A 20kHz increase in resonant frequency shift was recorded when the middle membrane radius of these devices was increased from 7μm to 10μm while operating under a 20V top membrane bias and -3V to -5V middle membrane bias. These results demonstrate the expansion of the devices’ cavity heights beyond conventional capacitive micromachined transducers. These observations indicate that the middle membrane radius has influence on the dynamic control of effective cavity height in M 3 -CMUTs.
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (9) , 1-4
Expanding Limit of Detection and Increasing Operating Resonant Frequency via Larger Anchor Widths for Capacitive Micromachined Resonator-Based Mass Sensors
An innovative technique is explored, aiming to expand the limit of detection (LOD) and increase operating resonant frequency of capacitive micromachined ultrasonic transducer (CMUT) working as a mass sensor through modifying anchor widths. Limit of detection is associated with the concentration range of target compounds and therefore, their correspondent mass that can be measured using a CMUT mass sensor. Poly Multi-User MEMS Process (PolyMUMPs) sacrificial technique is used to fabricate three CMUT sensors with a range of anchor widths while keeping all other sensor design parameters and material properties constant. Experimental analysis is conducted to evaluate the influence of anchor width to resonant frequency and frequency shift at different biasing conditions. The experimental results demonstrates that a larger anchor width can increase CMUT operating resonant frequency and pull-in voltage, allowing for expanded LOD. These results also agree with analytical expressions presented. In addition, it is shown that through employing a designed anchor width, resonant frequencies can be varied to fulfill specific sensor requirements with minimal fabrication adjustments. This study contributes to the evolving knowledge of CMUT as a mass sensor, enabling more methods for variability of these devices.
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (9) , 1-4
Expanding Limit of Detection and Increasing Operating Resonant Frequency via Larger Anchor Widths for Capacitive Micromachined Resonator-Based Mass Sensors
An innovative technique is explored, aiming to expand the limit of detection (LOD) and increase operating resonant frequency of capacitive micromachined ultrasonic transducer (CMUT) working as a mass sensor through modifying anchor widths. Limit of detection is associated with the concentration range of target compounds and therefore, their correspondent mass that can be measured using a CMUT mass sensor. Poly Multi-User MEMS Process (PolyMUMPs) sacrificial technique is used to fabricate three CMUT sensors with a range of anchor widths while keeping all other sensor design parameters and material properties constant. Experimental analysis is conducted to evaluate the influence of anchor width to resonant frequency and frequency shift at different biasing conditions. The experimental results demonstrates that a larger anchor width can increase CMUT operating resonant frequency and pull-in voltage, allowing for expanded LOD. These results also agree with analytical expressions presented. In addition, it is shown that through employing a designed anchor width, resonant frequencies can be varied to fulfill specific sensor requirements with minimal fabrication adjustments. This study contributes to the evolving knowledge of CMUT as a mass sensor, enabling more methods for variability of these devices.