Pavithra Munirathinam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pavithra Munirathinam has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Arezoo Emadi
University of Windsor
5 shared publications - Haleh Nazemi
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON, Canada
4 shared publications - Douglas A. Buchanan
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Manitoba, ON, Canada
2 shared publications Bruce Ye
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON, Canada
1 shared publicationGian Carlo Antony Raj
E-Minds Laboratory in Electrical and Computer Engineering Department, University of Windsor, Windsor, Canada
1 shared publicationHaleh Nazemi
University of Windsor
1 shared publication
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (12) , 6013204-6013207
Novel Multiple Moving Membrane Micromachined Ultrasonic Transducers With Bilateral Anchor Boundary Configurations
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (12) , 6013204-6013207
Novel Multiple Moving Membrane Micromachined Ultrasonic Transducers With Bilateral Anchor Boundary Configurations
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (9) , 1501604
Enhanced Gravimetric Sensitivity of Capacitive MEMS Resonators via Geometric Design Modification
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (9) , 1501604
Enhanced Gravimetric Sensitivity of Capacitive MEMS Resonators via Geometric Design Modification
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. PP, 1-4
DISTRIBUTION OF THE CLAMPED BOUNDARY AND ITS IMPACT ON RESONATOR PERFORMANCE
Capacitive resonator performance including sensitivity is determined by its capacitive change and resonant frequency shift in response to an external perturbation such as added mass. Conventional designs are inherently defined by fully clamped boundaries around the deflectable plate. However, recent advances suggest that bilateral and quadrilateral concentric boundary resonators can offer improved performance through enhanced deflection compared to conventional fully clamped resonators. This work analyses how the spatial distribution of clamped boundaries under identical total clamped angles affects key resonator metrics including sensitivity, which is manifested through change in capacitance and frequency shift in electrical characterization. Resonators with bilateral and quadrilateral clamped boundary configurations are the focus of this work to demonstrate the idea. In order to do this, resonators with total clamped angles of 120°, 180°, and 240° are fabricated and characterized using electrical impedance analysis, with results in agreement with the conducted finite element analysis. The quadrilateral configurations outperformed bilateral ones in both frequency shift and capacitance change, indicating that clamped boundary distribution serves as a critical design parameter. These findings offer new insight into structural optimization strategies for capacitive resonators beyond conventional clamping schemes.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. PP, 1-4
DISTRIBUTION OF THE CLAMPED BOUNDARY AND ITS IMPACT ON RESONATOR PERFORMANCE
Capacitive resonator performance including sensitivity is determined by its capacitive change and resonant frequency shift in response to an external perturbation such as added mass. Conventional designs are inherently defined by fully clamped boundaries around the deflectable plate. However, recent advances suggest that bilateral and quadrilateral concentric boundary resonators can offer improved performance through enhanced deflection compared to conventional fully clamped resonators. This work analyses how the spatial distribution of clamped boundaries under identical total clamped angles affects key resonator metrics including sensitivity, which is manifested through change in capacitance and frequency shift in electrical characterization. Resonators with bilateral and quadrilateral clamped boundary configurations are the focus of this work to demonstrate the idea. In order to do this, resonators with total clamped angles of 120°, 180°, and 240° are fabricated and characterized using electrical impedance analysis, with results in agreement with the conducted finite element analysis. The quadrilateral configurations outperformed bilateral ones in both frequency shift and capacitance change, indicating that clamped boundary distribution serves as a critical design parameter. These findings offer new insight into structural optimization strategies for capacitive resonators beyond conventional clamping schemes.
- Open Access
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 156412-156419
Effect of Middle Membrane Dimensions on Dynamic Control Range in Dual Membrane Capacitive Micromachined Ultrasonic Transducers
Two sets of multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) are designed and fabricated for a range of middle membrane radii, from 35 – 49μm and 34 – 44μm. All other design parameters were kept identical within each set of experiments to enable a fair comparison. To study the dynamic control range of the designed M 3 -CMUTs, their performance was first evaluated through COMSOL simulation yielding results on the resonant frequency and corresponding cavity height. This was followed by fabrication of the same designs using multiuser microelectromechanical systems processes (MUMPs). The development of these prototypes enabled the comprehensive electrical characterization of the designs with responses that are demonstrated to be in full agreement with the simulation results. The middle membrane radii of the M 3 -CMUTs impact the collapse voltage of these devices in addition to the affecting the measured resonant frequencies when tested devices within the same measurement conditions. A 20kHz increase in resonant frequency shift was recorded when the middle membrane radius of these devices was increased from 7μm to 10μm while operating under a 20V top membrane bias and -3V to -5V middle membrane bias. These results demonstrate the expansion of the devices’ cavity heights beyond conventional capacitive micromachined transducers. These observations indicate that the middle membrane radius has influence on the dynamic control of effective cavity height in M 3 -CMUTs.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 156412-156419
Open AccessEffect of Middle Membrane Dimensions on Dynamic Control Range in Dual Membrane Capacitive Micromachined Ultrasonic Transducers
Two sets of multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) are designed and fabricated for a range of middle membrane radii, from 35 – 49μm and 34 – 44μm. All other design parameters were kept identical within each set of experiments to enable a fair comparison. To study the dynamic control range of the designed M 3 -CMUTs, their performance was first evaluated through COMSOL simulation yielding results on the resonant frequency and corresponding cavity height. This was followed by fabrication of the same designs using multiuser microelectromechanical systems processes (MUMPs). The development of these prototypes enabled the comprehensive electrical characterization of the designs with responses that are demonstrated to be in full agreement with the simulation results. The middle membrane radii of the M 3 -CMUTs impact the collapse voltage of these devices in addition to the affecting the measured resonant frequencies when tested devices within the same measurement conditions. A 20kHz increase in resonant frequency shift was recorded when the middle membrane radius of these devices was increased from 7μm to 10μm while operating under a 20V top membrane bias and -3V to -5V middle membrane bias. These results demonstrate the expansion of the devices’ cavity heights beyond conventional capacitive micromachined transducers. These observations indicate that the middle membrane radius has influence on the dynamic control of effective cavity height in M 3 -CMUTs.
- 11 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 5852-5859
Multiple Moving Membrane Capacitive Micromachined Ultrasonic Transducer With Dynamic Control Provision of Effective Cavity Height
A novel biasing scheme having the potential to dynamically control the effective cavity heights of two fabricated, multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) has been developed. With this unique approach it is may be possible to avoid design trade-off requirements of the ultrasonic transducers that affect both receiving and transmitting operating modes. Each of these M 3 -CMUTs has two vibrating membranes suspended over a fixed bottom electrode. The two air-coupled M 3 -CMUT devices with the resonant frequencies of 1MHz single cell and 1.5MHz array device were fabricated. Finite Element Analysis (FEA) was carried out to investigate the effect of an additional middle membrane on the effective cavity height and device performance. Experimental validation was then completed with the transducers operating under both positive and negative biasing conditions of middle membrane, while keeping the top membrane at selected positive biasing voltages to realize a dynamically controlled range of effective cavity heights. The new biasing scheme may facilitate dynamic tunning of resonant frequencies of transmitter and receiver transducers through the variation of effective cavity height for improved performance.
- 11 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 5852-5859
Multiple Moving Membrane Capacitive Micromachined Ultrasonic Transducer With Dynamic Control Provision of Effective Cavity Height
A novel biasing scheme having the potential to dynamically control the effective cavity heights of two fabricated, multiple moving membrane capacitive micromachined ultrasonic transducers (M 3 -CMUTs) has been developed. With this unique approach it is may be possible to avoid design trade-off requirements of the ultrasonic transducers that affect both receiving and transmitting operating modes. Each of these M 3 -CMUTs has two vibrating membranes suspended over a fixed bottom electrode. The two air-coupled M 3 -CMUT devices with the resonant frequencies of 1MHz single cell and 1.5MHz array device were fabricated. Finite Element Analysis (FEA) was carried out to investigate the effect of an additional middle membrane on the effective cavity height and device performance. Experimental validation was then completed with the transducers operating under both positive and negative biasing conditions of middle membrane, while keeping the top membrane at selected positive biasing voltages to realize a dynamically controlled range of effective cavity heights. The new biasing scheme may facilitate dynamic tunning of resonant frequencies of transmitter and receiver transducers through the variation of effective cavity height for improved performance.