Sandeep Kumar
Research Subjects
Research Interests
Sandeep Kumar has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Rajnish Aggarwal
Department of Prosthodontics, Surendera Dental College and Research Institute, Sri Ganganagar, IND
11 shared publicationsRahul Sharma
Department of Oral and Maxillofacial Surgery, Dr. S.S. Tantia Dental College, Hospital and Research Centre, Sri Ganganagar, IND
5 shared publicationsJaspinder Kaur
Surendera Dental College & Research Institute, Sri Ganganagar, Rajasthan, India
3 shared publicationsPamei Jenthuilu
Department of Prosthodontics, Surendera Dental College and Research Institute, Sri Ganganagar, IND
3 shared publicationsAniruddha Deokate
Department of Prosthodontics, Surendera Dental College and Research Institute, Sri Ganganagar, IND
2 shared publicationsAshutosh R. Singh
Department of Prosthodontics, Surendera Dental College and Research Institute, Sri Ganganagar, IND
2 shared publications
Latest Publications
- Open Access
- 6 April 2026
- Published by Springer Nature in Cureus
- Vol. 18 (4)
Effect of Three Different Commonly Available Gingival Retraction Systems on the Amount of Gingival Displacement: An In Vivo Study
Introduction: Accurate recording of finish line margins is essential for the success of fixed prosthodontic restoration. Gingival displacement plays a crucial role in achieving adequate exposure of the subgingival margins, thereby ensuring proper marginal adaptation and long-term periodontal health. Various gingival retraction systems, including conventional cords and newer cordless materials such as pastes and gels, are available; however, their comparative effectiveness remains a topic of clinical interest. This study aimed to evaluate and compare the effectiveness of three commonly used gingival retraction systems in achieving gingival displacement based on pre- and post-retraction measurements.
- 6 April 2026
- Published by Springer Nature in Cureus
- Vol. 18 (4)
Open AccessEffect of Three Different Commonly Available Gingival Retraction Systems on the Amount of Gingival Displacement: An In Vivo Study
Introduction: Accurate recording of finish line margins is essential for the success of fixed prosthodontic restoration. Gingival displacement plays a crucial role in achieving adequate exposure of the subgingival margins, thereby ensuring proper marginal adaptation and long-term periodontal health. Various gingival retraction systems, including conventional cords and newer cordless materials such as pastes and gels, are available; however, their comparative effectiveness remains a topic of clinical interest. This study aimed to evaluate and compare the effectiveness of three commonly used gingival retraction systems in achieving gingival displacement based on pre- and post-retraction measurements.
- Open Access
- 20 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2)
Comparative Stress Analysis of Maxillary Implant Prostheses With Different Retention Designs and Restorative Materials
Introduction: Implant-supported restorations are widely used to replace missing teeth; however, their long-term success depends largely on the biomechanical behavior of the implant-prosthesis complex. This study aimed to evaluate and compare stress distribution patterns in maxillary implant-supported restorations with different retention methods and crown materials under axial and oblique loading conditions using three-dimensional finite element analysis.
- 20 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2)
Open AccessComparative Stress Analysis of Maxillary Implant Prostheses With Different Retention Designs and Restorative Materials
Introduction: Implant-supported restorations are widely used to replace missing teeth; however, their long-term success depends largely on the biomechanical behavior of the implant-prosthesis complex. This study aimed to evaluate and compare stress distribution patterns in maxillary implant-supported restorations with different retention methods and crown materials under axial and oblique loading conditions using three-dimensional finite element analysis.
- Open Access
- 16 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2)
A Three-Dimensional Finite Element Analysis of Stress Distribution in Cement-Retained and Screw-Retained Implant-Supported Restorations in Mandible Using Porcelain-Fused-to-Metal and Zirconia Crowns
Introduction Dental implants are widely used to replace missing teeth; however, the biomechanical performance of implant-supported restorations may be influenced by the prosthesis retention type, restorative material, and direction of occlusal loading. Unfavorable stress distribution may lead to biological and mechanical complications, affecting long-term implant success. The present study aimed to evaluate and compare the stress distribution patterns in cement-retained and screw-retained implant-supported restorations fabricated with porcelain-fused-to-metal and zirconia crowns under axial and oblique loading conditions in the mandible using three-dimensional finite element analysis (FEA). Materials and methods A three-dimensional finite element model of the mandibular premolar region restored with a titanium dental implant was developed. Four restorative models were analyzed: cement-retained porcelain-fused-to-metal, screw-retained porcelain-fused-to-metal, cement-retained zirconia, and screw-retained zirconia crowns. All materials were considered to be homogeneous, isotropic, and linearly elastic. A vertical axial load of 100 N along the implant axis and an oblique load of 100 N applied at 300 to the implant axis were simulated. von Mises stress distribution was evaluated in the crown, abutment, implant, prosthetic screw, and surrounding cortical and cancellous bone. Results Axial loading produced a lower and more uniform stress distribution than oblique loading in all models. Cement-retained restorations demonstrated reduced stress concentrations in the implant-abutment interface and prosthetic components compared to screw-retained restorations. Porcelain-fused-to-metal crowns exhibited lower stress concentrations than zirconia crowns, particularly under oblique loading. The highest stress values were consistently observed in the crestal cortical bone and the implant neck region. Conclusions Within the limitations of this finite element study, cement-retained porcelain-fused-to-metal restorations demonstrated more favorable biomechanical behavior. Oblique loading generated higher stress than axial loading, emphasizing the importance of appropriate prosthetic design, material selection, and occlusal load control for long-term implant success.
- 16 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2)
Open AccessA Three-Dimensional Finite Element Analysis of Stress Distribution in Cement-Retained and Screw-Retained Implant-Supported Restorations in Mandible Using Porcelain-Fused-to-Metal and Zirconia Crowns
Introduction Dental implants are widely used to replace missing teeth; however, the biomechanical performance of implant-supported restorations may be influenced by the prosthesis retention type, restorative material, and direction of occlusal loading. Unfavorable stress distribution may lead to biological and mechanical complications, affecting long-term implant success. The present study aimed to evaluate and compare the stress distribution patterns in cement-retained and screw-retained implant-supported restorations fabricated with porcelain-fused-to-metal and zirconia crowns under axial and oblique loading conditions in the mandible using three-dimensional finite element analysis (FEA). Materials and methods A three-dimensional finite element model of the mandibular premolar region restored with a titanium dental implant was developed. Four restorative models were analyzed: cement-retained porcelain-fused-to-metal, screw-retained porcelain-fused-to-metal, cement-retained zirconia, and screw-retained zirconia crowns. All materials were considered to be homogeneous, isotropic, and linearly elastic. A vertical axial load of 100 N along the implant axis and an oblique load of 100 N applied at 300 to the implant axis were simulated. von Mises stress distribution was evaluated in the crown, abutment, implant, prosthetic screw, and surrounding cortical and cancellous bone. Results Axial loading produced a lower and more uniform stress distribution than oblique loading in all models. Cement-retained restorations demonstrated reduced stress concentrations in the implant-abutment interface and prosthetic components compared to screw-retained restorations. Porcelain-fused-to-metal crowns exhibited lower stress concentrations than zirconia crowns, particularly under oblique loading. The highest stress values were consistently observed in the crestal cortical bone and the implant neck region. Conclusions Within the limitations of this finite element study, cement-retained porcelain-fused-to-metal restorations demonstrated more favorable biomechanical behavior. Oblique loading generated higher stress than axial loading, emphasizing the importance of appropriate prosthetic design, material selection, and occlusal load control for long-term implant success.
- Open Access
- 26 June 2025
- Published by Springer Nature in Cureus
- Vol. 17 (6) , e86821
Finite Element Analysis of Platform Switching Effects on Stress Distribution in Posterior Implants Placed in Different Bone Types Under Axial and Oblique Loading Conditions
Introduction: The present study was conducted to compare stress distribution in platform-switched and non-platform-switched implants placed in D2 (mandible) and D3 (maxilla) bones under axial and oblique loading, using finite element analysis (FEA). Materials and methods: Cone-beam computed tomography (CBCT)-derived three-dimensional models of the posterior maxilla (D3) and mandible (D2) were developed. Implants (11.5 × 4.2 mm) were modeled with two abutment configurations: 4.2 mm (non-platform switching) and 3.2 mm (platform switching). Porcelain-fused-to-metal crowns were placed on all models. A vertical (axial) load of 200 N and an oblique load of 200 N at 30° were applied to the left first molar. ANSYS Workbench (ANSYS, Inc., Canonsburg, Pennsylvania) was used to assess the von Mises stress distribution in the cortical bone, cancellous bone, implant, abutment, and abutment screws. Results: Platform switching resulted in lower stress values in both D2 and D3 bones under axial and oblique loads, especially at the crestal bone level. The D3 (maxillary) models exhibited higher stress concentrations overall than the D2 (mandibular) models, indicating a greater biomechanical challenge in less dense bone. Platform switching effectively reduced the peak stresses and led to a more uniform stress distribution. However, the implant and abutment components in the platform-switched models experienced higher internal stress. Conclusion: Platform switching improved stress distribution and reduced crestal bone stress in both D2 and D3 bones, especially under oblique loading.
- 26 June 2025
- Published by Springer Nature in Cureus
- Vol. 17 (6) , e86821
Open AccessFinite Element Analysis of Platform Switching Effects on Stress Distribution in Posterior Implants Placed in Different Bone Types Under Axial and Oblique Loading Conditions
Introduction: The present study was conducted to compare stress distribution in platform-switched and non-platform-switched implants placed in D2 (mandible) and D3 (maxilla) bones under axial and oblique loading, using finite element analysis (FEA). Materials and methods: Cone-beam computed tomography (CBCT)-derived three-dimensional models of the posterior maxilla (D3) and mandible (D2) were developed. Implants (11.5 × 4.2 mm) were modeled with two abutment configurations: 4.2 mm (non-platform switching) and 3.2 mm (platform switching). Porcelain-fused-to-metal crowns were placed on all models. A vertical (axial) load of 200 N and an oblique load of 200 N at 30° were applied to the left first molar. ANSYS Workbench (ANSYS, Inc., Canonsburg, Pennsylvania) was used to assess the von Mises stress distribution in the cortical bone, cancellous bone, implant, abutment, and abutment screws. Results: Platform switching resulted in lower stress values in both D2 and D3 bones under axial and oblique loads, especially at the crestal bone level. The D3 (maxillary) models exhibited higher stress concentrations overall than the D2 (mandibular) models, indicating a greater biomechanical challenge in less dense bone. Platform switching effectively reduced the peak stresses and led to a more uniform stress distribution. However, the implant and abutment components in the platform-switched models experienced higher internal stress. Conclusion: Platform switching improved stress distribution and reduced crestal bone stress in both D2 and D3 bones, especially under oblique loading.
- Open Access
- 15 June 2025
- Published by IP Innovative Publication Pvt Ltd in Journal of Advances in Oral Health
- Vol. 2 (1) , 14-18
Rehabilitation of maxillectomy in mucormycosis patient by using obturator: A case report
Rehabilitation of maxillectomy in mucormycosis patient by using obturator: A case report - JAOH- Print ISSN No: - Online ISSN No:- 3049-060X Article DOI No:- 10.18231/j.jaoh.2025.004, Journal of Advances in Oral Health-J Adv Oral Health
- 15 June 2025
- Published by IP Innovative Publication Pvt Ltd in Journal of Advances in Oral Health
- Vol. 2 (1) , 14-18
Open AccessRehabilitation of maxillectomy in mucormycosis patient by using obturator: A case report
Rehabilitation of maxillectomy in mucormycosis patient by using obturator: A case report - JAOH- Print ISSN No: - Online ISSN No:- 3049-060X Article DOI No:- 10.18231/j.jaoh.2025.004, Journal of Advances in Oral Health-J Adv Oral Health
- Open Access
- 18 May 2025
- Published by Springer Nature in Cureus
- Vol. 17 (5) , e84329
Biomechanical Analysis of Angled Abutments in the Anterior Maxilla: Impact of Bone Quality and Loading Conditions Using Finite Element Analysis
Objective: This in vitro study utilized three-dimensional (3D) finite element analysis (FEA) to investigate the stress distribution around dental implants in the anterior maxilla, focusing on the interplay between 15° angled abutments, bone quality (D1-D4), and loading conditions (axial and oblique). Methodology: Anatomically accurate 3D models of the anterior maxilla, a titanium Internal-Hex implant system (TouaregTM(S), Adin Dental Implants, Chile), a 15° angled abutment, and a porcelain-fused-to-metal crown were developed using cone-beam computed tomographic (CBCT) scans and CATIA V5 software (Dassault Systèms, Vélizy-Villacoublay, France) and then analyzed in ANSYS Workbench (ANSYS Inc., Canonsburg, Pennsylvania, USA). Four bone types (D1-D4) were modeled with varying cortical and cancellous proportions. Axial (178 N) and oblique (100 N at 120°) loads were applied to eight models, and the stress and strain distributions were evaluated at the implant-bone and implant-abutment interfaces using tetrahedral elements. Mesh convergence ensured computational accuracy, and the material properties reflected clinical data. Results: Axial loading showed uniform stress at the implant neck, with cortical bone stress increasing from 12.023 MPa (D1) to 26.438 MPa (D4) and implant stress increasing from 67.319 MPa to 72.291 MPa. Oblique loading amplified stress asymmetrically, with cortical bone stress increasing from 20.005 to 30.704 MPa and implant stress from 97.910 to 102.458 MPa. D3 and D4 exhibit significantly higher stresses, particularly under oblique loading. Conclusion: Bone quality and loading type critically influenced stress distribution. The stresses were higher in the D3 and D4 bones under oblique loading. Bone D1 and D2 provided robust support, whereas bones D3 and D4 required enhanced implant designs or augmentation. The 15° angled abutment increased stress, necessitating careful prosthetic planning to ensure biomechanical stability and esthetic outcomes in anterior maxillary implant dentistry.
- 18 May 2025
- Published by Springer Nature in Cureus
- Vol. 17 (5) , e84329
Open AccessBiomechanical Analysis of Angled Abutments in the Anterior Maxilla: Impact of Bone Quality and Loading Conditions Using Finite Element Analysis
Objective: This in vitro study utilized three-dimensional (3D) finite element analysis (FEA) to investigate the stress distribution around dental implants in the anterior maxilla, focusing on the interplay between 15° angled abutments, bone quality (D1-D4), and loading conditions (axial and oblique). Methodology: Anatomically accurate 3D models of the anterior maxilla, a titanium Internal-Hex implant system (TouaregTM(S), Adin Dental Implants, Chile), a 15° angled abutment, and a porcelain-fused-to-metal crown were developed using cone-beam computed tomographic (CBCT) scans and CATIA V5 software (Dassault Systèms, Vélizy-Villacoublay, France) and then analyzed in ANSYS Workbench (ANSYS Inc., Canonsburg, Pennsylvania, USA). Four bone types (D1-D4) were modeled with varying cortical and cancellous proportions. Axial (178 N) and oblique (100 N at 120°) loads were applied to eight models, and the stress and strain distributions were evaluated at the implant-bone and implant-abutment interfaces using tetrahedral elements. Mesh convergence ensured computational accuracy, and the material properties reflected clinical data. Results: Axial loading showed uniform stress at the implant neck, with cortical bone stress increasing from 12.023 MPa (D1) to 26.438 MPa (D4) and implant stress increasing from 67.319 MPa to 72.291 MPa. Oblique loading amplified stress asymmetrically, with cortical bone stress increasing from 20.005 to 30.704 MPa and implant stress from 97.910 to 102.458 MPa. D3 and D4 exhibit significantly higher stresses, particularly under oblique loading. Conclusion: Bone quality and loading type critically influenced stress distribution. The stresses were higher in the D3 and D4 bones under oblique loading. Bone D1 and D2 provided robust support, whereas bones D3 and D4 required enhanced implant designs or augmentation. The 15° angled abutment increased stress, necessitating careful prosthetic planning to ensure biomechanical stability and esthetic outcomes in anterior maxillary implant dentistry.
- Open Access
- 30 April 2025
- Published by Springer Nature in Cureus
- Vol. 17 (4)
Comparative Evaluation of Surface Hardness of Bis-Acryl Composite and Polymethyl Methacrylate-Based Provisional Restorative Materials: An In Vitro Study
Introduction: Provisional restorations are essential components of fixed prosthodontic treatment that provide protection, function, esthetics, and guidance during the transitional phase before definitive restorations are placed. The choice of materials for provisional restorations plays a critical role in determining their clinical effectiveness and durability. Among the numerous available materials, bis-acryl composite resins and polymethyl methacrylate (PMMA)-based acrylics are widely used. Surface hardness is a key mechanical property that directly affects a material's resistance to masticatory forces, wear, and deformation during function. This in vitro study was conducted to compare the surface hardness of three bis-acryl composite materials with that of one PMMA-based material to aid clinicians in selecting the most suitable material based on the performance characteristics. Materials and methods: This in vitro study was conducted in the Department of Prosthodontics. Group 1 (n=40) used 3M Protemp 4 Temporization Material (St. Paul, MN: 3M ESPE AG), group 2 (n=40) used Dentsply Integrity Temporary Crown and Bridge Material (York, PA: Dentsply Sirona), group 3 (n=40) used Vericom Care C&B Dual-Cure Temporary Material (Anyang, South Korea: Vericom Co. Ltd.), and group 4 (n=40) used Pyrax High-Quality Cold Cure SC-10 (Roorkee, India: Pyrax Polymars). The specimens were prepared using stainless-steel molds. Each material was manipulated according to the manufacturer's instructions and cured according to recommended protocols. Vickers hardness testing was performed under a 25 g load for 15 s. Two indentations were made per specimen, and the Vickers Hardness Number (VHN) was calculated. The data were then subjected to statistical analysis. Results: Group 1 recorded the highest mean hardness (20.54±0.69 VHN), followed by group 2 with 19.80±0.47 VHN, group 3 with 18.55±1.36 VHN, and group 4 showing the lowest hardness (16.65±0.66 VHN). One-way Analysis of Variance (ANOVA) revealed statistically significant differences between all groups (p<0.01), with group 1 exhibiting the highest hardness across pairwise comparisons. Conclusion: Bis-acryl composite materials demonstrated a significantly higher surface hardness than PMMA-based materials. 3M Protemp 4 showed the greatest hardness and may be best suited for long-term provisional restorations, whereas Pyrax SC-10 is more appropriate for short-term use owing to its lower mechanical strength.
- 30 April 2025
- Published by Springer Nature in Cureus
- Vol. 17 (4)
Open AccessComparative Evaluation of Surface Hardness of Bis-Acryl Composite and Polymethyl Methacrylate-Based Provisional Restorative Materials: An In Vitro Study
Introduction: Provisional restorations are essential components of fixed prosthodontic treatment that provide protection, function, esthetics, and guidance during the transitional phase before definitive restorations are placed. The choice of materials for provisional restorations plays a critical role in determining their clinical effectiveness and durability. Among the numerous available materials, bis-acryl composite resins and polymethyl methacrylate (PMMA)-based acrylics are widely used. Surface hardness is a key mechanical property that directly affects a material's resistance to masticatory forces, wear, and deformation during function. This in vitro study was conducted to compare the surface hardness of three bis-acryl composite materials with that of one PMMA-based material to aid clinicians in selecting the most suitable material based on the performance characteristics. Materials and methods: This in vitro study was conducted in the Department of Prosthodontics. Group 1 (n=40) used 3M Protemp 4 Temporization Material (St. Paul, MN: 3M ESPE AG), group 2 (n=40) used Dentsply Integrity Temporary Crown and Bridge Material (York, PA: Dentsply Sirona), group 3 (n=40) used Vericom Care C&B Dual-Cure Temporary Material (Anyang, South Korea: Vericom Co. Ltd.), and group 4 (n=40) used Pyrax High-Quality Cold Cure SC-10 (Roorkee, India: Pyrax Polymars). The specimens were prepared using stainless-steel molds. Each material was manipulated according to the manufacturer's instructions and cured according to recommended protocols. Vickers hardness testing was performed under a 25 g load for 15 s. Two indentations were made per specimen, and the Vickers Hardness Number (VHN) was calculated. The data were then subjected to statistical analysis. Results: Group 1 recorded the highest mean hardness (20.54±0.69 VHN), followed by group 2 with 19.80±0.47 VHN, group 3 with 18.55±1.36 VHN, and group 4 showing the lowest hardness (16.65±0.66 VHN). One-way Analysis of Variance (ANOVA) revealed statistically significant differences between all groups (p<0.01), with group 1 exhibiting the highest hardness across pairwise comparisons. Conclusion: Bis-acryl composite materials demonstrated a significantly higher surface hardness than PMMA-based materials. 3M Protemp 4 showed the greatest hardness and may be best suited for long-term provisional restorations, whereas Pyrax SC-10 is more appropriate for short-term use owing to its lower mechanical strength.
- Open Access
- 3 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e78414
Evaluation of the Antibacterial and Antifungal Efficacy of Chitosan Nanoparticles in Irreversible Hydrocolloid Impression Materials: A Cross-Sectional Study
Introduction: Irreversible hydrocolloid (IHC) impression materials are widely used in dentistry for diagnostic impressions; however, they pose a risk of cross-contamination. Current cleaning methods such as rinsing with water may not be sufficient for effective disinfection. Incorporation of antimicrobial agents into IHC materials can reduce this risk. Chitosan, a biopolymer with proven antibacterial and antifungal properties, has potential as a self-disinfecting agent for IHC materials. This study aimed to evaluate the antibacterial and antifungal efficacy of chitosan nanoparticles (CHN) incorporated into IHC (alginate) impression materials. Materials and methods: This cross-sectional study was conducted in the Department of Prosthodontics, at the Surendera Dental College and Research Institute, Sri Ganganagar, Rajasthan, India, with 20 dentulous patients. A 1% CHN was incorporated into the IHC impression material to serve as Group 1, while conventional alginate mixed with distilled water with a one-week interval between each impression served as Group 2. Impressions were made on patients' maxillary arches, with bacterial and fungal samples collected at 0- and 10-minute intervals after rinsing the impressions. The samples were cultured on nutrient agar and Sabouraud dextrose agar for bacteria and fungi, respectively. Colony counts were assessed and statistically analyzed. Results: The study found a significant reduction in both bacterial and fungal counts in impressions made with Group 1 compared with Group 2 at both 0- and 10-minute intervals (p<0.001). At 10 minutes, bacterial counts decreased significantly in Group 1 (from 75.50±34.56 to 26.00±16.03), and fungal counts were also reduced (from 2.70±1.22 to 0.55±0.69). The antibacterial and antifungal efficacy was increased at the 10-minute interval, compared to the 0-minute interval. Conclusion: Incorporating 1% CHN into the IHC impression material significantly enhanced its antibacterial and antifungal properties, making it an effective self-disinfecting agent. This modification reduces the need for additional disinfection steps and offers a practical solution for improving cross-infection control in dental practice. CHN's biocompatibility and biodegradability further support its potential as an eco-friendly and sustainable alternative for dental materials.
- 3 February 2025
- Published by Springer Nature in Cureus
- Vol. 17 (2) , e78414
Open AccessEvaluation of the Antibacterial and Antifungal Efficacy of Chitosan Nanoparticles in Irreversible Hydrocolloid Impression Materials: A Cross-Sectional Study
Introduction: Irreversible hydrocolloid (IHC) impression materials are widely used in dentistry for diagnostic impressions; however, they pose a risk of cross-contamination. Current cleaning methods such as rinsing with water may not be sufficient for effective disinfection. Incorporation of antimicrobial agents into IHC materials can reduce this risk. Chitosan, a biopolymer with proven antibacterial and antifungal properties, has potential as a self-disinfecting agent for IHC materials. This study aimed to evaluate the antibacterial and antifungal efficacy of chitosan nanoparticles (CHN) incorporated into IHC (alginate) impression materials. Materials and methods: This cross-sectional study was conducted in the Department of Prosthodontics, at the Surendera Dental College and Research Institute, Sri Ganganagar, Rajasthan, India, with 20 dentulous patients. A 1% CHN was incorporated into the IHC impression material to serve as Group 1, while conventional alginate mixed with distilled water with a one-week interval between each impression served as Group 2. Impressions were made on patients' maxillary arches, with bacterial and fungal samples collected at 0- and 10-minute intervals after rinsing the impressions. The samples were cultured on nutrient agar and Sabouraud dextrose agar for bacteria and fungi, respectively. Colony counts were assessed and statistically analyzed. Results: The study found a significant reduction in both bacterial and fungal counts in impressions made with Group 1 compared with Group 2 at both 0- and 10-minute intervals (p<0.001). At 10 minutes, bacterial counts decreased significantly in Group 1 (from 75.50±34.56 to 26.00±16.03), and fungal counts were also reduced (from 2.70±1.22 to 0.55±0.69). The antibacterial and antifungal efficacy was increased at the 10-minute interval, compared to the 0-minute interval. Conclusion: Incorporating 1% CHN into the IHC impression material significantly enhanced its antibacterial and antifungal properties, making it an effective self-disinfecting agent. This modification reduces the need for additional disinfection steps and offers a practical solution for improving cross-infection control in dental practice. CHN's biocompatibility and biodegradability further support its potential as an eco-friendly and sustainable alternative for dental materials.
- Open Access
- 25 January 2025
- Published by Springer Nature in Cureus
- Vol. 17 (1) , e77988
Impact of Soft Liners on Bite Force in Complete Denture Wearers: A Prospective Cohort Study
Introduction: Edentulism is a significant global oral health concern, particularly among elderly individuals. Complete dentures are widely used to restore oral functionality, esthetics, and quality of life. The incorporation of soft liners into complete dentures has been proposed as a means of improving patient comfort and reducing the pressure on the oral mucosa. This study aimed to evaluate and compare the maximum bite force (MBF) in patients wearing complete dentures with and without soft liners for over six months. Materials and methods: Forty-four completely edentulous patients participated in this prospective cohort study, divided into two groups: Group 1 (n=22) received complete dentures with long-term, heat-cured, plasticized acrylic liners (Permasoft, Dentsply International, York, PA, USA) and Group 2 (n=22) received conventional complete dentures without liners. MBF was recorded at two months (T0) and six months (T1) after denture delivery. Statistical analyses included paired t-tests for intragroup comparisons and independent t-tests for intergroup comparisons. Results: Group 1 demonstrated a significant increase in MBF, from 46.07±12.28 N at T0 to 66.34±13.81 newtons (N) at T1 (P=0.021). Similarly, Group 2 exhibited an increase in MBF, from 38.32±12.61 N at T0 to 49.41±10.89 N at T1 (P=0.001). Intergroup comparisons revealed significantly higher MBF in Group 1 than in Group 2 at both time points, with a mean difference of 16.93 N (P=0.001) at T1. Conclusion: The results indicated that the use of soft liners in complete dentures significantly increased MBF over six months compared with conventional dentures. These findings underscore the clinical value of soft liners in improving denture performance and patient outcomes.
- 25 January 2025
- Published by Springer Nature in Cureus
- Vol. 17 (1) , e77988
Open AccessImpact of Soft Liners on Bite Force in Complete Denture Wearers: A Prospective Cohort Study
Introduction: Edentulism is a significant global oral health concern, particularly among elderly individuals. Complete dentures are widely used to restore oral functionality, esthetics, and quality of life. The incorporation of soft liners into complete dentures has been proposed as a means of improving patient comfort and reducing the pressure on the oral mucosa. This study aimed to evaluate and compare the maximum bite force (MBF) in patients wearing complete dentures with and without soft liners for over six months. Materials and methods: Forty-four completely edentulous patients participated in this prospective cohort study, divided into two groups: Group 1 (n=22) received complete dentures with long-term, heat-cured, plasticized acrylic liners (Permasoft, Dentsply International, York, PA, USA) and Group 2 (n=22) received conventional complete dentures without liners. MBF was recorded at two months (T0) and six months (T1) after denture delivery. Statistical analyses included paired t-tests for intragroup comparisons and independent t-tests for intergroup comparisons. Results: Group 1 demonstrated a significant increase in MBF, from 46.07±12.28 N at T0 to 66.34±13.81 newtons (N) at T1 (P=0.021). Similarly, Group 2 exhibited an increase in MBF, from 38.32±12.61 N at T0 to 49.41±10.89 N at T1 (P=0.001). Intergroup comparisons revealed significantly higher MBF in Group 1 than in Group 2 at both time points, with a mean difference of 16.93 N (P=0.001) at T1. Conclusion: The results indicated that the use of soft liners in complete dentures significantly increased MBF over six months compared with conventional dentures. These findings underscore the clinical value of soft liners in improving denture performance and patient outcomes.
- 4 May 2023
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 24 (1) , 16-20
Three-dimensional Finite Element Stress Pattern Analysis in Bone around Implant-supported Abutment with Different Angulations under Axial and Oblique Load
The goal of this research was to compare the stress distribution in the bone adjacent to the implant where three different angled abutments were loaded in both the axial and oblique directions. The premaxilla region was digitally recreated in 3-dimension (3D) using a finite element model, with a solid 4.2 mm by 13 mm implant and abutments at 0°, 15°, and 25° of rotation. Axial load (100 N) and oblique load were also applied to the abutments (178 N). Six models were made and used with a fixed bases. The coefficient of friction was set at a constant value of 0.02. The CITIA program was used for the stress analysis. In this investigation, we employed linear static analysis. Each abutment and crown in the model has subjected to an arbitrary vertical load as well as the oblique load. The cortical bone around the implant with a 25° angled abutment experienced a maximum von Mises stress of 187.692 Mpa under oblique load. This stress was increased with the degree of abutment angulation. As abutment angulation was increased, axial and oblique burdens were also increased. In both cases, we were able to identify the source of the observed growth. When we looked at the effect of stress on angulation, we found that the peaks were seen in the area of abutment and cortical bone. Since it was difficult to predict the stress distribution around implants with varying abutment angles in a clinical setting, finite element analysis (FEA) was chosen for this investigation as a more cutting-edge approach. It is a herculean task calculating the prompted forces clinically, FEA has opted for this study as it's a progressively wielded tool to prognosticate the stress allocation in the region of the implants with different angled abutments.
- 4 May 2023
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 24 (1) , 16-20
Three-dimensional Finite Element Stress Pattern Analysis in Bone around Implant-supported Abutment with Different Angulations under Axial and Oblique Load
The goal of this research was to compare the stress distribution in the bone adjacent to the implant where three different angled abutments were loaded in both the axial and oblique directions. The premaxilla region was digitally recreated in 3-dimension (3D) using a finite element model, with a solid 4.2 mm by 13 mm implant and abutments at 0°, 15°, and 25° of rotation. Axial load (100 N) and oblique load were also applied to the abutments (178 N). Six models were made and used with a fixed bases. The coefficient of friction was set at a constant value of 0.02. The CITIA program was used for the stress analysis. In this investigation, we employed linear static analysis. Each abutment and crown in the model has subjected to an arbitrary vertical load as well as the oblique load. The cortical bone around the implant with a 25° angled abutment experienced a maximum von Mises stress of 187.692 Mpa under oblique load. This stress was increased with the degree of abutment angulation. As abutment angulation was increased, axial and oblique burdens were also increased. In both cases, we were able to identify the source of the observed growth. When we looked at the effect of stress on angulation, we found that the peaks were seen in the area of abutment and cortical bone. Since it was difficult to predict the stress distribution around implants with varying abutment angles in a clinical setting, finite element analysis (FEA) was chosen for this investigation as a more cutting-edge approach. It is a herculean task calculating the prompted forces clinically, FEA has opted for this study as it's a progressively wielded tool to prognosticate the stress allocation in the region of the implants with different angled abutments.