TAToshiaki Asakai

Toshiaki Asakai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Toshiaki Asakai has a total of 250 co-authors. Here are the top co-authors by number of shared publications:

  • Akiharu Hioki

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan

    16 shared publications
  • Toshihiro Suzuki

    National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)

    8 shared publications
  • Igor Maksimov

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan

    6 shared publications
  • Mariko Murayama

    National Institute of Technology and Evaluation

    6 shared publications
  • Tatsuhiko Tanaka

    Faculty of Engineering, Tokyo University of Science

    6 shared publications
  • Igor Maksimov

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan

    4 shared publications

Latest Publications

  • Open Access

    Activity Coefficients of HCl in Solutions Related to “Tris” Buffers in Artificial Seawater. II. HCl + NaCl + TrisHCl + H2O, and Tris Buffer + NaCl + H2O, to High Ionic Strength and from 5 to 40 °C

    by Igor Maksimov, Toshiaki Asakai, Yuya Hibino, Simon L. Clegg

    The substance Tris (2-amino-2-hydroxymethyl-1,3-propanediol, CAS 77-86-1), and its protonated form TrisH+, are used in the preparation of ‘total’ pH buffers in artificial seawater media. The development of a chemical speciation model of the buffer solutions, using the Pitzer equations to calculate solute activity coefficients, is desirable in order to quantify the effects of composition change, convert the total pH to other scales, and address metrological requirements for traceability to the International System of Units. Here, in the second of a series of studies, we present Harned cell measurements of potentials and mean activity coefficients of HCl in solutions containing HCl, NaCl, and TrisHCl for ionic strengths from 1.0 to 5.5 mol kg–1 and from 5 to 40 °C. The results at 25 °C are consistent with those of the literature studies of the two end-member solutions (aqueous HCl + NaCl, and HCl + TrisHCl). We also present results of measurements of buffer solutions containing equimolal Tris and TrisHCl (hence TrisH+), and NaCl, at ionic strengths of 0.2, 1.0, and 4.0 mol kg–1 at the same temperatures. These are compared with literature data for Tris buffers in an artificial seawater medium. Aspects of the development of a Pitzer model for these solutions are discussed.


  • Coulometric titration of sulfanilamide as a standard for diazotization titration and nitrite determination

    by Toshiaki Asakai

    Sulfanilamide and nitrite have been standardized to each other by diazotization titration; however, no literature was found on determination methods for either material on an absolute basis. In the present study, coulometric titration with electrogenerated bromine was first used to determine sulfanilamide. Coulometric titration provides absolute assays of the amount of substances, based on Faraday’s laws of electrolysis, and also has a high degree of accuracy compared to other instrumental methods. Nitrite was assayed by diazotization titration based on the coulometrically determined sulfanilamide. This idea provides a new methodology for the absolute determination of the purity of basic chemicals whose purity could previously only be assessed in relative terms. Graphical Abstract

  • Open Access

    Activity Coefficients of HCl in Solutions Related to “Tris” Buffers in Artificial Seawater. I. HCl + TrisHCl + H2O from 1.0 to 5.0 mol kg–1 Ionic Strength, and from 5 to 45 °C

    by Igor Maksimov, Toshiaki Asakai, Yuya Hibino, Simon L. Clegg

    The substance Tris (2-amino-2-hydroxymethyl-1,3-propanediol, CAS 77-86-1), and its protonated form TrisH+, are used in the preparation of pH buffers in artificial seawater media for applications in marine chemistry. The development of a chemical speciation model of the buffer solutions has been proposed in order to quantify the effects of composition change on buffer pH and to address the metrological requirement for traceability of pH to SI base units. Such a model should be based upon data yielding solvent activities and mean activity coefficients (especially those of H+ with conjugate anions such as Cl- or SO4 2-) for aqueous solutions of single solutes (e.g., HCl, TrisHCl) and simple mixtures over a temperature range of about 0 to 40 °C. There are currently few data for solutions containing the ion TrisH+, and these are mostly restricted to 25 °C. Here, in the first of a series of studies, we present Harned cell measurements of potentials in solutions containing HCl and TrisHCl from 5 to 45 °C, yielding mean activity coefficients of HCl. The results at 25 °C are found to agree closely with those of literature studies. The Harned cell technique is described in detail, including the preparation of electrodes.


  • Batch-to-batch reproducibility for the primary pH method for the example of NMIJ carbonate buffer solutions

    by Toshiaki Asakai, Igor Maksimov, Sachiko Onuma

    At present, the National Metrology Institute of Japan provides six national primary pH buffers under the Japan Calibration Service System. Each batch of these buffers is certified by the primary pH method using a Harned cell. On the basis of these primary buffers, the designated laboratories supply the secondary and working pH standards using a high-precision pH meter. This paper provides an estimate of the batch-to-batch reproducibility of the primary pH standard production based on the history of the certification of primary carbonate buffers in NMIJ. This buffer, which was chosen as the subject of the study because of the relative difficulty of its measurements (and thus a greater dispersion of results), is nominally the 0.025 mol kg−1 equimolal solution of disodium carbonate and sodium hydrogen carbonate. As its pH value is significantly affected by the purity of the reagents used, the evaluation of their source materials is made by both pH measurements and acidimetric gravimetric back titrations. Considering the experimentally determined pH reproducibility of ca. 0.010, potential risks to the pH accuracy are discussed when using recipe-based carbonate pH standards. Graphical Abstract


  • Open Access

    Applicable Measuring Range of Two-Electrode Type Commercial Electrolytic Conductivity Meter for Accurate Determination of Electrolytic Conductivity

    by Yuya Hibino, Toshiaki Asakai, Toshihiro Suzuki, Masaki Ohata

    Applicable measuring range of electrolytic conductivity (EC) for commercially available two-electrode type EC meter was examined. The measurement error caused by a gap in ECs between the measurement sample and the standard solution was also evaluated. Seven potassium chloride (KCl) solutions including certified reference materials (CRMs) manufactured by the National Metrology Institute of Japan (NMIJ) were measured, and the cell constants observed for commercial EC meters as well as the effect of electrode polarization were compared in detail under strict temperature control. The effect of electrode polarization can be sufficiently small if the frequency is properly selected. In the case of KCl standard solution with concentrations of 0.1molkg-1 (1Sm-1) or less, the obtained cell constants were almost identical to those of declared ones. However, in the case of KCl standard solution with concentrations of 0.5molkg-1 (5Sm-1) or more, the obtained cell constants showed 2-10 higher than those of declared ones. From these results, the calibration by standard solution with closer EC to the measurement solution is especially important if about 1 accuracy of measurement by commercial EC meter is required in higher EC range such as 5Sm-1 or more.


  • Final report on CCQM-K19.2018 key comparison on pH of an unknown borate buffer

    by Toshiaki Asakai, Igor Maksimov, Sergey Prokunin, Daria Vengina, Narine Oganyan, Vladimir Dobrovolskiy, Nagy Dániel, Szilágyi Zsofia, Lyudmila Dimitrova, Katya Bezeva, et al.

    Main text: This key comparison CCQM-K19.2018, as a repetition of the previous study CCQM-K19 from 2005, was performed to evaluate the degree of equivalence of measurement procedures of participating National Metrology Institutes (NMIs) and Designated Institutes (DIs) for the determination of pH of borate buffer solutions. The nominal pH value of the buffer was 9.2 at 25 °C and the suggested measurement temperatures were 5 °C, 15 °C, 25 °C, 37 °C and 50 °C. Good agreement of the results is demonstrated by most participants. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Final report on APMP.QM-K18.2016 key comparison on pH measurement of carbonate buffer

    by Toshiaki Asakai, Igor Maksimov, Sachiko Onuma, Frank Bastkowski, Beatrice Sander, José Luis Ortiz Aparicio, Judith Velina Lara Manzano, Samuel M F Lo, Desmond K F Poon, Mabel Delgado, et al.

    Main text: This key comparison is being performed to evaluate the degree of equivalence of measurement procedures to support the participants' claims of Calibration and Measurement Capabilities (CMCs) and to evaluate the capabilities of participants for the determination of the pH of carbonate buffer solutions. This is the fourth APMP key comparison on pH measurement following APMP.QM-K9/P16 (phosphate), APMP.QM-K19/P25 (borate) and APMP.QM-K91/P29 (phthalate). The results have the linkage to CCQM-K18.2016 (carbonate buffer) and were evaluated by comparing the results of the Physikalisch-Technische Bundesanstalt (PTB) and the National Metrology Institute of Japan (NMIJ) performing Harned cell method. The results of PTB and NMIJ were used for the definition of the Key Comparison Reference Value (KCRV). The ensuing pH value was calculated based on the Bates-Guggenheim convention to compare the results of primary and secondary methods. In this comparison measurements of pH were performed only at the temperature of 25 °C. The results demonstrated by most participants are in better agreement than those in CCQM-K18.2016. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).