Yutaka Tanami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yutaka Tanami has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Eiji Oguma
Department of Radiology, Saitama Children’s Medical Center, Saitama, Japan
18 shared publications - Takahiro Hosokawa
Department of Radiology Saitama Children's Medical Center Saitama Japan
18 shared publications - Yumiko Sato
Department of Radiology, Saitama Children’s Medical Center, Saitama, Japan
17 shared publications - Hiroshi Kawashima
Department of Surgery, Saitama Children’s Medical Center, Saitama, Japan
5 shared publications - Mayumi Hosokawa
Department of Pediatrics, Saitama City Hospital, Saitama, Japan
3 shared publications - Tetsuya Ishimaru
Department of Surgery, Saitama Children’s Medical Center, Saitama, Japan
3 shared publications
Latest Publications
- 16 April 2025
- Published by Springer Nature in Emergency Radiology
- Vol. 32 (3) , 309-317
Sonographic diagnosis of testicular loss or atrophy after incarcerated inguinal hernia in pediatric patients
Purpose Incarcerated inguinal hernia is a common condition in pediatric patients presenting to the emergency department. In addition to causing intestinal obstruction, it can lead to acute testicular venous occlusion, necessitating urgent intervention. This study aimed to demonstrate the utility of ultrasonography in predicting testicular loss/atrophy associated with incarcerated inguinal hernia in pediatric patients. Methods This study enrolled 58 patients with incarcerated inguinal hernia. Pre- and post-reduction sonographic findings, including the vascularity, enlargement, and echogenicity of the affected testis, were compared between patients with and without testicular loss/atrophy using Fisher’s exact and Mann–Whitney U tests. The imaging studies were reviewed by two radiologists blinded to clinical information and other imaging findings, with discrepancies resolved by consensus. Results All pre- and post-reduction sonographic findings were significantly different between the patients with and without testicular loss/atrophy, including vascularity (evaluated in 32 patients post-reduction; present/absent in 0/3 vs. 24/5), enlargement (evaluated in 50 patients; present/absent in 2/1 vs. 4/43), and echogenicity (evaluated in 50 patients; normal/abnormal in 0/3 vs. 47/0). The differences observed post-reduction were significant in terms of vascularity (evaluated in 38; present/absent in 0/3 vs. 30/5), enlargement (evaluated in 57 patients; present/absent in 2/1 vs. 1/53), and echogenicity (evaluated in 57 patients; normal/abnormal in 0/3 vs. 54/0). Conclusions The vascularity, enlargement, and echogenicity within the affected testes on the ipsilateral side of the incarcerated inguinal hernia are useful sonographic findings for predicting testicular loss/atrophy. Therefore, ultrasonologist should evaluate the testicular condition in cases of an incarcerated inguinal hernia.
- 16 April 2025
- Published by Springer Nature in Emergency Radiology
- Vol. 32 (3) , 309-317
Sonographic diagnosis of testicular loss or atrophy after incarcerated inguinal hernia in pediatric patients
Purpose Incarcerated inguinal hernia is a common condition in pediatric patients presenting to the emergency department. In addition to causing intestinal obstruction, it can lead to acute testicular venous occlusion, necessitating urgent intervention. This study aimed to demonstrate the utility of ultrasonography in predicting testicular loss/atrophy associated with incarcerated inguinal hernia in pediatric patients. Methods This study enrolled 58 patients with incarcerated inguinal hernia. Pre- and post-reduction sonographic findings, including the vascularity, enlargement, and echogenicity of the affected testis, were compared between patients with and without testicular loss/atrophy using Fisher’s exact and Mann–Whitney U tests. The imaging studies were reviewed by two radiologists blinded to clinical information and other imaging findings, with discrepancies resolved by consensus. Results All pre- and post-reduction sonographic findings were significantly different between the patients with and without testicular loss/atrophy, including vascularity (evaluated in 32 patients post-reduction; present/absent in 0/3 vs. 24/5), enlargement (evaluated in 50 patients; present/absent in 2/1 vs. 4/43), and echogenicity (evaluated in 50 patients; normal/abnormal in 0/3 vs. 47/0). The differences observed post-reduction were significant in terms of vascularity (evaluated in 38; present/absent in 0/3 vs. 30/5), enlargement (evaluated in 57 patients; present/absent in 2/1 vs. 1/53), and echogenicity (evaluated in 57 patients; normal/abnormal in 0/3 vs. 54/0). Conclusions The vascularity, enlargement, and echogenicity within the affected testes on the ipsilateral side of the incarcerated inguinal hernia are useful sonographic findings for predicting testicular loss/atrophy. Therefore, ultrasonologist should evaluate the testicular condition in cases of an incarcerated inguinal hernia.
- Open Access
- 3 March 2025
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 52 (2) , 253-260
Ultrasound findings of unplanned extraction of tunneled central venous catheters due to complications within subcutaneous tissue
Purpose: Tunneled central venous catheters (CVC) are essential medical devices for pediatric patients facing extended treatment periods. This study aimed to demonstrate the usefulness of ultrasound in evaluating complications in subcutaneous tissue associated with unplanned extraction of tunneled CVC. Methods: Twenty-five patients who underwent ultrasound examination for suspected complications in the subcutaneous tissue associated with tunneled areas from CVC were included. The following patient characteristics and imaging findings were evaluated: infection in subcutaneous tissue, high echogenicity and hypoechoic effusion around the catheter within the subcutaneous tissue, and hyperechoic foci around the catheter. Patients with CVC were classified into two groups: those with and those without unplanned extraction of tunneled CVC. Fisher’s exact test was used to compare the two groups. Results: Nine patients had unplanned extraction of tunneled CVC. A significant difference was found in infection at tunneled areas (presence/absence in patients with vs. those without unplanned extraction = 7/2 vs. 2/14, P = 0.002), as well as in hypoechoic effusion around the catheter within the subcutaneous tissues (presence/absence in patients with vs. those without unplanned extraction = 9/0 vs. 3/13, P < 0.001). However, no significant differences were found in the presence or absence of high echogenicity (presence/absence in patients with vs. those without unplanned extraction = 7/2 vs. 6/10, P = 0.097) or hyperechoic foci around the catheter (presence/absence in patients with vs. those without unplanned extraction = 3/6 vs. 1/15, P = 0.116). Conclusion: The ultrasound findings were useful for determining the necessity of tunneled CVC extraction. These results will be helpful for improving management of pediatric patients with CVC.
- 3 March 2025
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 52 (2) , 253-260
Open AccessUltrasound findings of unplanned extraction of tunneled central venous catheters due to complications within subcutaneous tissue
Purpose: Tunneled central venous catheters (CVC) are essential medical devices for pediatric patients facing extended treatment periods. This study aimed to demonstrate the usefulness of ultrasound in evaluating complications in subcutaneous tissue associated with unplanned extraction of tunneled CVC. Methods: Twenty-five patients who underwent ultrasound examination for suspected complications in the subcutaneous tissue associated with tunneled areas from CVC were included. The following patient characteristics and imaging findings were evaluated: infection in subcutaneous tissue, high echogenicity and hypoechoic effusion around the catheter within the subcutaneous tissue, and hyperechoic foci around the catheter. Patients with CVC were classified into two groups: those with and those without unplanned extraction of tunneled CVC. Fisher’s exact test was used to compare the two groups. Results: Nine patients had unplanned extraction of tunneled CVC. A significant difference was found in infection at tunneled areas (presence/absence in patients with vs. those without unplanned extraction = 7/2 vs. 2/14, P = 0.002), as well as in hypoechoic effusion around the catheter within the subcutaneous tissues (presence/absence in patients with vs. those without unplanned extraction = 9/0 vs. 3/13, P < 0.001). However, no significant differences were found in the presence or absence of high echogenicity (presence/absence in patients with vs. those without unplanned extraction = 7/2 vs. 6/10, P = 0.097) or hyperechoic foci around the catheter (presence/absence in patients with vs. those without unplanned extraction = 3/6 vs. 1/15, P = 0.116). Conclusion: The ultrasound findings were useful for determining the necessity of tunneled CVC extraction. These results will be helpful for improving management of pediatric patients with CVC.
- 14 December 2024
- Published by Springer Nature in Journal of Ultrasound
- Vol. 28 (2) , 349-358
Diagnostic performance of ultrasound for myositis and fasciitis, including necrotizing fasciitis, in pediatric patients
Objectives To demonstrate the diagnostic performance of ultrasound for abnormal magnetic resonance imaging findings in pediatric patients with suspected myositis and fasciitis. We compared sonographic findings between patients with and without necrotizing fasciitis. Methods In 21 pediatric patients, the presence or absence of abnormal T2-high signal intensity in subcutaneous fat, peripheral deep fascia, intermuscular fascia, and muscle was recorded. The extent of the disease based on ultrasound findings was recorded according to the previous locations. The vascular lumen within the affected muscle was also evaluated. Patients were classified into two groups: those with necrotizing fasciitis and those without. The presence/absence of sonographic findings and width of fluid accumulation in the peripheral deep fascia was compared between the two groups. Results Three patients were classified into the necrotizing fasciitis group. The ultrasound diagnostic performance for abnormal findings in subcutaneous fat/peripheral deep fascia/ intermuscular fascia/muscle was 90.5%/76.2%/47.6%/90.5%, respectively. The presence/absence of abnormal findings in peripheral deep fascial edema, its width and vascular lumen collapse were significantly different between the two groups. The other findings were not significantly different between the groups. Conclusions Ultrasound demonstrated reliability in detecting abnormal findings and was useful for diagnosing necrotizing fasciitis, facilitating urgent surgical intervention.
- 14 December 2024
- Published by Springer Nature in Journal of Ultrasound
- Vol. 28 (2) , 349-358
Diagnostic performance of ultrasound for myositis and fasciitis, including necrotizing fasciitis, in pediatric patients
Objectives To demonstrate the diagnostic performance of ultrasound for abnormal magnetic resonance imaging findings in pediatric patients with suspected myositis and fasciitis. We compared sonographic findings between patients with and without necrotizing fasciitis. Methods In 21 pediatric patients, the presence or absence of abnormal T2-high signal intensity in subcutaneous fat, peripheral deep fascia, intermuscular fascia, and muscle was recorded. The extent of the disease based on ultrasound findings was recorded according to the previous locations. The vascular lumen within the affected muscle was also evaluated. Patients were classified into two groups: those with necrotizing fasciitis and those without. The presence/absence of sonographic findings and width of fluid accumulation in the peripheral deep fascia was compared between the two groups. Results Three patients were classified into the necrotizing fasciitis group. The ultrasound diagnostic performance for abnormal findings in subcutaneous fat/peripheral deep fascia/ intermuscular fascia/muscle was 90.5%/76.2%/47.6%/90.5%, respectively. The presence/absence of abnormal findings in peripheral deep fascial edema, its width and vascular lumen collapse were significantly different between the two groups. The other findings were not significantly different between the groups. Conclusions Ultrasound demonstrated reliability in detecting abnormal findings and was useful for diagnosing necrotizing fasciitis, facilitating urgent surgical intervention.
- Open Access
- 16 March 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (3) , 543
Correction: Point-of-care ultrasonography for the diagnosis and manual detorsion of testicular torsion
- 16 March 2024
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (3) , 543
Open AccessCorrection: Point-of-care ultrasonography for the diagnosis and manual detorsion of testicular torsion
- Open Access
- 10 November 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (45) , e35746
A single-center experience of using milk scintigraphy in 251 pediatric patients: A retrospective study
To report our experience with milk gastroesophageal scintigraphy and the management of gastroesophageal reflux (GER) in children. In 251 pediatric patients we recorded age, underlying disease, central nervous system (CNS) disorders, and GER management. GER management was classified based on treatment plans: grade 0, non-pharmacological treatment; grade 1, non-pharmacological but using a nasogastric tube; grade 2, pharmacological treatment; grade 3, transpyloric feeding; and grade 4, Nissen fundoplication surgery. Patients were included in classified groups with (grades 2, 3, and 4) and without (grades 0 and 1) GER treatment. We evaluated the GER height (classified based on the height of GER, grade 0; no GER, 1; GER in the lower esophagus, 2; GER in the upper esophagus), GER duration in the lower and upper esophagus, presence or absence of massive GER amounts in the lower and upper esophagus, and gastric emptying time. We compared milk scintigraphy results and patient characteristics between groups with (grades 2, 3, and 4) and without (grades 0 and 1) GER treatment. We treated 121 patients for GER. CNS disorders (presence/absence: 46/74 with vs 21/110 without treatment, P < .001). The GER height grade (1.7 ± 0.5 [range, 0–2] with vs 1.5 ± 0.7 [range, 0–2] without treatment, P = .002), massive GER amount (present/absent: 21/99 with vs 9/122 without treatment, P = .011), and duration of GER (seconds) (324.5 ± 508.3 [range, 0–1800] vs 125.0 ± 291.9 [range, 0–1750], P < .001) in the upper esophageal half differed significantly. Similarly massive GER amount (present/absent: 54/66 with vs 34/97 without treatment, P = .002) and GER duration (621.3 ± 601.0 [range, 0–1800] vs 349.8 ± 452.4 [range, 0–1800], P < .001) in the lower esophageal half differed significantly. Additionally, CNS disorders, age, and massive GER in the upper esophageal half differed significantly among grades 2 and 4 in treated patients (P < .05, P < .001, P < .05, respectively). Milk scintigraphy is useful for deciding whether GER treatment is indicated. However, the treatment plan needs to be decided based on each patient’s condition.
- 10 November 2023
- Published by Wolters Kluwer Health in Medicine
- Vol. 102 (45) , e35746
Open AccessA single-center experience of using milk scintigraphy in 251 pediatric patients: A retrospective study
To report our experience with milk gastroesophageal scintigraphy and the management of gastroesophageal reflux (GER) in children. In 251 pediatric patients we recorded age, underlying disease, central nervous system (CNS) disorders, and GER management. GER management was classified based on treatment plans: grade 0, non-pharmacological treatment; grade 1, non-pharmacological but using a nasogastric tube; grade 2, pharmacological treatment; grade 3, transpyloric feeding; and grade 4, Nissen fundoplication surgery. Patients were included in classified groups with (grades 2, 3, and 4) and without (grades 0 and 1) GER treatment. We evaluated the GER height (classified based on the height of GER, grade 0; no GER, 1; GER in the lower esophagus, 2; GER in the upper esophagus), GER duration in the lower and upper esophagus, presence or absence of massive GER amounts in the lower and upper esophagus, and gastric emptying time. We compared milk scintigraphy results and patient characteristics between groups with (grades 2, 3, and 4) and without (grades 0 and 1) GER treatment. We treated 121 patients for GER. CNS disorders (presence/absence: 46/74 with vs 21/110 without treatment, P < .001). The GER height grade (1.7 ± 0.5 [range, 0–2] with vs 1.5 ± 0.7 [range, 0–2] without treatment, P = .002), massive GER amount (present/absent: 21/99 with vs 9/122 without treatment, P = .011), and duration of GER (seconds) (324.5 ± 508.3 [range, 0–1800] vs 125.0 ± 291.9 [range, 0–1750], P < .001) in the upper esophageal half differed significantly. Similarly massive GER amount (present/absent: 54/66 with vs 34/97 without treatment, P = .002) and GER duration (621.3 ± 601.0 [range, 0–1800] vs 349.8 ± 452.4 [range, 0–1800], P < .001) in the lower esophageal half differed significantly. Additionally, CNS disorders, age, and massive GER in the upper esophageal half differed significantly among grades 2 and 4 in treated patients (P < .05, P < .001, P < .05, respectively). Milk scintigraphy is useful for deciding whether GER treatment is indicated. However, the treatment plan needs to be decided based on each patient’s condition.
- Open Access
- 20 October 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (1) , 59-70
Point-of-care ultrasonography for the diagnosis and manual detorsion of testicular torsion
Testicular torsion is a urological emergency caused by the loss of testicular tissue due to ischemic damage. Rapid diagnosis and urgent treatment play a crucial role in the management of testicular torsion. Manual detorsion can be performed at the bedside, thereby reducing the duration of ischemia. Recent studies have reported the use of point-of-care ultrasonography for diagnosing testicular torsion; however, no review article has focused on the ultrasonographic findings pertaining to manual detorsion. This review describes the diagnosis of testicular torsion and the ultrasonographic indications for manual detorsion. Spermatic cord twisting or the whirlpool sign, absence of or decreased blood flow within the affected testis, abnormal testicular axis, abnormal echogenicity, and enlargement of the affected testis and epididymis due to ischemia are the sonographic findings associated with testicular torsion. The following findings are considered indications for manual detorsion: direction of testicular torsion, i.e., inner or outer direction (ultrasonographic accuracy of 70%), and the degree of spermatic cord twist. The following sonographic findings are used to determine whether the treatment was successful: presence of the whirlpool sign and the degree and extent of perfusion of the affected testis. Misdiagnosis of the direction of manual detorsion, a high degree of spermatic cord twisting and insufficient detorsion, testicular compartment syndrome, and testicular necrosis were found to result in treatment failure. The success of manual detorsion is determined based on the symptoms and sonographic findings. Subsequent surgical exploration is recommended in all cases, regardless of the success of manual detorsion.
- 20 October 2023
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 51 (1) , 59-70
Open AccessPoint-of-care ultrasonography for the diagnosis and manual detorsion of testicular torsion
Testicular torsion is a urological emergency caused by the loss of testicular tissue due to ischemic damage. Rapid diagnosis and urgent treatment play a crucial role in the management of testicular torsion. Manual detorsion can be performed at the bedside, thereby reducing the duration of ischemia. Recent studies have reported the use of point-of-care ultrasonography for diagnosing testicular torsion; however, no review article has focused on the ultrasonographic findings pertaining to manual detorsion. This review describes the diagnosis of testicular torsion and the ultrasonographic indications for manual detorsion. Spermatic cord twisting or the whirlpool sign, absence of or decreased blood flow within the affected testis, abnormal testicular axis, abnormal echogenicity, and enlargement of the affected testis and epididymis due to ischemia are the sonographic findings associated with testicular torsion. The following findings are considered indications for manual detorsion: direction of testicular torsion, i.e., inner or outer direction (ultrasonographic accuracy of 70%), and the degree of spermatic cord twist. The following sonographic findings are used to determine whether the treatment was successful: presence of the whirlpool sign and the degree and extent of perfusion of the affected testis. Misdiagnosis of the direction of manual detorsion, a high degree of spermatic cord twisting and insufficient detorsion, testicular compartment syndrome, and testicular necrosis were found to result in treatment failure. The success of manual detorsion is determined based on the symptoms and sonographic findings. Subsequent surgical exploration is recommended in all cases, regardless of the success of manual detorsion.
- 8 June 2023
- Published by Elsevier in Journal of Infection and Chemotherapy
- Vol. 29 (10) , 937-941
Association between the imaging characteristics of renal abscess and vesicoureteral reflux
- 8 June 2023
- Published by Elsevier in Journal of Infection and Chemotherapy
- Vol. 29 (10) , 937-941
Association between the imaging characteristics of renal abscess and vesicoureteral reflux
- 21 December 2022
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 24 (4) , 491-495
Role of ultrasound in the diagnosis of very early-onset inflammatory bowel disease in children: a report of three cases
Very early-onset inflammatory bowel disease (VEO-IBD) is defined as IBD onset before 6 years of age and some cases are caused by unique monogenic disorders that require specific treatments such as stem cell transplantation. We identified three children with VEO-IBD of whom two had monogenic disorders. In cases 1 and 2, ultrasound revealed isolated colonic distribution and the loss of wall stratification. In case 3, mesentery inflammation was evident. Bowel ultrasound showed variable findings due to differences in the inflammation distribution within the bowel. In order to diagnose VEO-IBD, sonographersshould carefully evaluate the intestinal wall thickness and stratification and the distribution of inflammation in the intestine and mesentery. These findings may aid the diagnosis of VEO-IBD.
- 21 December 2022
- Published by SRUMB - Romanian Society for Ultrasonography in Medicine and Biology in Medical Ultrasonography
- Vol. 24 (4) , 491-495
Role of ultrasound in the diagnosis of very early-onset inflammatory bowel disease in children: a report of three cases
Very early-onset inflammatory bowel disease (VEO-IBD) is defined as IBD onset before 6 years of age and some cases are caused by unique monogenic disorders that require specific treatments such as stem cell transplantation. We identified three children with VEO-IBD of whom two had monogenic disorders. In cases 1 and 2, ultrasound revealed isolated colonic distribution and the loss of wall stratification. In case 3, mesentery inflammation was evident. Bowel ultrasound showed variable findings due to differences in the inflammation distribution within the bowel. In order to diagnose VEO-IBD, sonographersshould carefully evaluate the intestinal wall thickness and stratification and the distribution of inflammation in the intestine and mesentery. These findings may aid the diagnosis of VEO-IBD.
- 19 February 2022
- Published by Springer Nature in Emergency Radiology
- Vol. 29 (3) , 455-460
Association between the corrosion of ingested lithium button battery in the esophagus and its complications in pediatric patients
Purpose The incidence of lithium button battery ingestion has been increasing recently, which results in severe complications. We aimed to demonstrate the association between the corrosion of lithium button batteries in the esophagus on radiographs and their complications. Methods The nine pediatric patients included in this study were classified into two groups based on the presence of severe complications. The presence and degree of corrosion on plain radiographs were evaluated. The degree of corrosion was classified into the following three grades; none: 0%; moderate: 1–50%; severe: 51–100%. Fisher’s exact test was used for statistical analyses. Results Of the nine patients, five showed complications. The number of patients who had grade none, moderate, and severe degrees of corrosion was three, four, and two, respectively. The incidence of severe complications differed significantly between the incidence of lithium button batteries’ contour (without vs. with severe complications [presence/absence of corrosion] = 1/3 vs. 5/0, respectively; P = 0.0476). In cases with “none” degree of corrosion, all three cases had no complication, and in cases with a “severe” degree of corrosion, all two cases had complications. Conclusion The cases with the presence of corrosion of lithium button batteries had a higher tendency to have severe complications. Therefore, physicians should anticipate the presence of severe complications in pediatric patients with corrosion more than those without corrosion.
- 19 February 2022
- Published by Springer Nature in Emergency Radiology
- Vol. 29 (3) , 455-460
Association between the corrosion of ingested lithium button battery in the esophagus and its complications in pediatric patients
Purpose The incidence of lithium button battery ingestion has been increasing recently, which results in severe complications. We aimed to demonstrate the association between the corrosion of lithium button batteries in the esophagus on radiographs and their complications. Methods The nine pediatric patients included in this study were classified into two groups based on the presence of severe complications. The presence and degree of corrosion on plain radiographs were evaluated. The degree of corrosion was classified into the following three grades; none: 0%; moderate: 1–50%; severe: 51–100%. Fisher’s exact test was used for statistical analyses. Results Of the nine patients, five showed complications. The number of patients who had grade none, moderate, and severe degrees of corrosion was three, four, and two, respectively. The incidence of severe complications differed significantly between the incidence of lithium button batteries’ contour (without vs. with severe complications [presence/absence of corrosion] = 1/3 vs. 5/0, respectively; P = 0.0476). In cases with “none” degree of corrosion, all three cases had no complication, and in cases with a “severe” degree of corrosion, all two cases had complications. Conclusion The cases with the presence of corrosion of lithium button batteries had a higher tendency to have severe complications. Therefore, physicians should anticipate the presence of severe complications in pediatric patients with corrosion more than those without corrosion.
- 6 January 2022
- Published by Springer Nature in Journal of Ultrasound
- Vol. 25 (3) , 745-755
The role of ultrasound to evaluate the disorders of sex development: a pictorial essay
Ultrasonography is usually the first modality used to evaluate patients with disorders of sex development (DSD). To determine the sex in patients with DSD, the following four categories are carefully evaluated: chromosomal, gonadal, anatomical internal genitalia, and external genitalia. However, in the clinical setting, the only information that sonographers have prior to ultrasound examination is the appearance of the external genitalia. The following DSD presentations are commonly observed: (1) male external genitalia present at birth, without testis in the scrotum or with a small penis; (2) female external genitalia present at birth, with an inguinal hernia or clitoromegaly; (3) neonates with ambiguous genitalia at birth; and (4) female or male external genitalia without sexual maturity. In this retrospective study of several clinical cases, we demonstrated an ultrasound-based sex determination approach for these clinical presentations. We found that sonographers evaluated the external genitalia in relation to the distal urethra within the corpus spongiosum and corpus cavernosum and the presence or absence of follicles within the detected gonads to determine the sex of the patient.
- 6 January 2022
- Published by Springer Nature in Journal of Ultrasound
- Vol. 25 (3) , 745-755
The role of ultrasound to evaluate the disorders of sex development: a pictorial essay
Ultrasonography is usually the first modality used to evaluate patients with disorders of sex development (DSD). To determine the sex in patients with DSD, the following four categories are carefully evaluated: chromosomal, gonadal, anatomical internal genitalia, and external genitalia. However, in the clinical setting, the only information that sonographers have prior to ultrasound examination is the appearance of the external genitalia. The following DSD presentations are commonly observed: (1) male external genitalia present at birth, without testis in the scrotum or with a small penis; (2) female external genitalia present at birth, with an inguinal hernia or clitoromegaly; (3) neonates with ambiguous genitalia at birth; and (4) female or male external genitalia without sexual maturity. In this retrospective study of several clinical cases, we demonstrated an ultrasound-based sex determination approach for these clinical presentations. We found that sonographers evaluated the external genitalia in relation to the distal urethra within the corpus spongiosum and corpus cavernosum and the presence or absence of follicles within the detected gonads to determine the sex of the patient.