Guiqiu Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guiqiu Liao has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Rosa
University of Strasbourg, CNRS, INSERM, ICube, Strasbourg, France
3 shared publications - Daniel A. Hashimoto
University of Pennsylvania
3 shared publications - Diego Dall’aLba
University of Verona
3 shared publications - Florent Nageotte
University of Strasbourg, CNRS, INSERM
3 shared publications - Matjaž Jogan
University of Pennsylvania
3 shared publications - Michalina J. Gora
Wyss Center for Bio and Neuroengineering, Geneva, Switzerland
3 shared publications
Latest Publications
- 25 September 2026
- Published by Springer Nature
- p. 123-133
DenseTRF: Texture-Aware Unsupervised Representation Adaptation for Surgical Scene Dense Prediction
- 25 September 2026
- Published by Springer Nature
- p. 123-133
DenseTRF: Texture-Aware Unsupervised Representation Adaptation for Surgical Scene Dense Prediction
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Analysis and correction of OCT images for the control of robotic flexible endoscopes
Analyse et correction d'images OCT pour le contrôle d'endoscopes flexibles robotisés: L'objectif de cette thèse est d'automatiser l'imagerie robotique en permettant une opération en boucle fermée pour une numérisation automatique précise en présence de mouvement tissulaire. Tout d'abord, un problème spécifique des cathéters OCT de numérisation rotative, appelé distorsion de rotation non uniforme(NURD), qui entrave les tâches de diagnostic et de navigation, est examiné. Une nouvelle solution pour la correction en ligne est proposée. Ensuite, un algorithme de segmentation multi-surfaces d'images OCT à vision latérale est développé, qui est également adapté à l'échographie intravasculaire (IVUS). Un pipeline d'apprentissage fédéré décentralisé est démontré pour former le réseau d'encodage de lignes A avec des images OCT et IVUS, améliorant les performances du réseau. Enfin, une rétroaction en temps réel est fournie pour la numérisation volumétrique robotique, en maintenant les tissus mous dans le champ de vision et en limitant la force de contact.
- 7 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Analysis and correction of OCT images for the control of robotic flexible endoscopes
Analyse et correction d'images OCT pour le contrôle d'endoscopes flexibles robotisés: L'objectif de cette thèse est d'automatiser l'imagerie robotique en permettant une opération en boucle fermée pour une numérisation automatique précise en présence de mouvement tissulaire. Tout d'abord, un problème spécifique des cathéters OCT de numérisation rotative, appelé distorsion de rotation non uniforme(NURD), qui entrave les tâches de diagnostic et de navigation, est examiné. Une nouvelle solution pour la correction en ligne est proposée. Ensuite, un algorithme de segmentation multi-surfaces d'images OCT à vision latérale est développé, qui est également adapté à l'échographie intravasculaire (IVUS). Un pipeline d'apprentissage fédéré décentralisé est démontré pour former le réseau d'encodage de lignes A avec des images OCT et IVUS, améliorant les performances du réseau. Enfin, une rétroaction en temps réel est fournie pour la numérisation volumétrique robotique, en maintenant les tissus mous dans le champ de vision et en limitant la force de contact.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
Automatic OCT scanning of moving soft tissue using continuum endoscopic robots
Optical Coherence Tomography (OCT) offers real-time, high-resolution imaging of tissue internal structures, presenting a potential enhancement over conventional endoscopic examination of the digestive system surface. However, miniaturized OCT probes typically present challenges with a limited field of view and require precise positioning to optimize tissue visualization. This research addresses the challenge by leveraging robotizing a surgical endoscope and a steerable OCT probe to provide closed-loop scanning of larger areas in the presence of tissue motion. We propose a robotic multi-pullback technique, supported by real-time, tactile feedback from OCT images. Deep learning algorithms are employed for OCT image stabilization and segmentation, enabling autonomous robotic volumetric OCT scanning. Compared to previous works, our closed-loop control approach considers, in addition to the probe flexibility, also the movements and deformations of the tissue during the robotic scanning. For experimental validation, we designed a moving soft tissue phantom with force sensing and compared the proposed method with fixed-angle approaches. Our method consistently maintained minimal contact forces (around 50 mN) and clear tissue visibility for tissues with different stiffness and motion patterns. Resulting imaging quality was further validated using a multi-layer optical phantom under dynamic conditions.
- 6 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
Automatic OCT scanning of moving soft tissue using continuum endoscopic robots
Optical Coherence Tomography (OCT) offers real-time, high-resolution imaging of tissue internal structures, presenting a potential enhancement over conventional endoscopic examination of the digestive system surface. However, miniaturized OCT probes typically present challenges with a limited field of view and require precise positioning to optimize tissue visualization. This research addresses the challenge by leveraging robotizing a surgical endoscope and a steerable OCT probe to provide closed-loop scanning of larger areas in the presence of tissue motion. We propose a robotic multi-pullback technique, supported by real-time, tactile feedback from OCT images. Deep learning algorithms are employed for OCT image stabilization and segmentation, enabling autonomous robotic volumetric OCT scanning. Compared to previous works, our closed-loop control approach considers, in addition to the probe flexibility, also the movements and deformations of the tissue during the robotic scanning. For experimental validation, we designed a moving soft tissue phantom with force sensing and compared the proposed method with fixed-angle approaches. Our method consistently maintained minimal contact forces (around 50 mN) and clear tissue visibility for tissues with different stiffness and motion patterns. Resulting imaging quality was further validated using a multi-layer optical phantom under dynamic conditions.
- Open Access
- 3 February 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 110, 103972
Slot-BERT: Self-supervised object discovery in surgical video
- 3 February 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 110, 103972
Open AccessSlot-BERT: Self-supervised object discovery in surgical video
- 20 September 2025
- Published by Springer Nature
- p. 219-229
Future Slot Prediction for Unsupervised Object Discovery in Surgical Video
- 20 September 2025
- Published by Springer Nature
- p. 219-229
Future Slot Prediction for Unsupervised Object Discovery in Surgical Video
- Open Access
- 22 January 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 77, 102355
Distortion and instability compensation with deep learning for rotational scanning endoscopic optical coherence tomography
- 22 January 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 77, 102355
Open AccessDistortion and instability compensation with deep learning for rotational scanning endoscopic optical coherence tomography
- 29 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 855-865
Data Stream Stabilization for Optical Coherence Tomography Volumetric Scanning
Optical Coherence Tomography (OCT) is an emerging medical imaging modality for luminal organ diagnosis. The non-constant rotation speed of optical components in the OCT catheter tip causes rotational distortion in OCT volumetric scanning. By improving the scanning process, this instability can be partially reduced. To further correct the rotational distortion in the OCT image, a volumetric data stabilization algorithm is proposed. The algorithm first estimates the Non-Uniform Rotational Distortion (NURD) for each B-scan by using a Convolutional Neural Network (CNN). A correlation map between two successive B-scans is computed and provided as input to the CNN. To solve the problem of accumulative error in iterative frame stream processing, we deploy an overall rotation estimation between reference orientation and actual OCT image orientation. We train the network with synthetic OCT videos by intentionally adding rotational distortion into real OCT images. As part of this article we discuss the proposed method in two different scanning modes: the first is a conventional pullback mode where the optical components move along the protection sheath, and the second is a self-designed scanning mode where the catheter is globally translated by using an external actuator. The efficiency and robustness of the proposed method are evaluated with synthetic scans as well as real scans under two scanning modes.
- 29 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 855-865
Data Stream Stabilization for Optical Coherence Tomography Volumetric Scanning
Optical Coherence Tomography (OCT) is an emerging medical imaging modality for luminal organ diagnosis. The non-constant rotation speed of optical components in the OCT catheter tip causes rotational distortion in OCT volumetric scanning. By improving the scanning process, this instability can be partially reduced. To further correct the rotational distortion in the OCT image, a volumetric data stabilization algorithm is proposed. The algorithm first estimates the Non-Uniform Rotational Distortion (NURD) for each B-scan by using a Convolutional Neural Network (CNN). A correlation map between two successive B-scans is computed and provided as input to the CNN. To solve the problem of accumulative error in iterative frame stream processing, we deploy an overall rotation estimation between reference orientation and actual OCT image orientation. We train the network with synthetic OCT videos by intentionally adding rotational distortion into real OCT images. As part of this article we discuss the proposed method in two different scanning modes: the first is a conventional pullback mode where the optical components move along the protection sheath, and the second is a self-designed scanning mode where the catheter is globally translated by using an external actuator. The efficiency and robustness of the proposed method are evaluated with synthetic scans as well as real scans under two scanning modes.
- Open Access
- 20 January 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (2) , 955-968
Colon phantoms with cancer lesions for endoscopic characterization with optical coherence tomography
Optical coherence tomography (OCT) is a growing imaging technique for real-time early diagnosis of digestive system diseases. As with other well-established medical imaging modalities, OCT requires validated imaging performance and standardized test methods for performance assessment. A major limitation in the development and testing of new imaging technologies is the lack of models for simultaneous clinical procedure emulation and characterization of healthy and diseased tissues. Currently, the former can be tested in large animal models and the latter can be tested in small animal disease models or excised human biopsy samples. In this study, a 23 cm by 23 cm optical phantom was developed to mimic the thickness and near-infrared optical properties of each anatomical layer of a human colon, as well as the surface topography of colorectal polyps and visual appearance compatible with white light endoscopy.
- 20 January 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 12 (2) , 955-968
Open AccessColon phantoms with cancer lesions for endoscopic characterization with optical coherence tomography
Optical coherence tomography (OCT) is a growing imaging technique for real-time early diagnosis of digestive system diseases. As with other well-established medical imaging modalities, OCT requires validated imaging performance and standardized test methods for performance assessment. A major limitation in the development and testing of new imaging technologies is the lack of models for simultaneous clinical procedure emulation and characterization of healthy and diseased tissues. Currently, the former can be tested in large animal models and the latter can be tested in small animal disease models or excised human biopsy samples. In this study, a 23 cm by 23 cm optical phantom was developed to mimic the thickness and near-infrared optical properties of each anatomical layer of a human colon, as well as the surface topography of colorectal polyps and visual appearance compatible with white light endoscopy.
- Open Access
- 2 April 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 277, 01008
Auto-tuning for cascade PID height position controller of rotorcraft
In this article, we present a method for tuning controller parameters for cascade PID based on the step response performance characteristics of a closed loop system with application to an unmanned aerial vehicle(UAV). With specifically designed system identification procedures, a neural network mapping is obtained automatically when the UAV is flying around the target height. With this network system model, a gradual regression and optimization algorithm is proposed to tune the controller. The regression model primly illustrated the relation between PID parameters with controller performance, and the construction for optimization cost function takes the physical significance of step response performance of flying machine into account. Experimental data collected from fight experiment when auto-tuner is implemented on a quadrotorcraft demonstrate the efficiency of the proposed method.
- 2 April 2019
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 277, 01008
Open AccessAuto-tuning for cascade PID height position controller of rotorcraft
In this article, we present a method for tuning controller parameters for cascade PID based on the step response performance characteristics of a closed loop system with application to an unmanned aerial vehicle(UAV). With specifically designed system identification procedures, a neural network mapping is obtained automatically when the UAV is flying around the target height. With this network system model, a gradual regression and optimization algorithm is proposed to tune the controller. The regression model primly illustrated the relation between PID parameters with controller performance, and the construction for optimization cost function takes the physical significance of step response performance of flying machine into account. Experimental data collected from fight experiment when auto-tuner is implemented on a quadrotorcraft demonstrate the efficiency of the proposed method.