Shuji Yamashita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuji Yamashita has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Takafumi Hirata
Geochemical Research Center, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
6 shared publications Takafumi Hirata
Geochemical Research Centre, The University of Tokyo
5 shared publicationsToshihiro Suzuki
4 shared publications- Sota Niki
Division for Chronological Research Institute for Space‐Earth Environmental Research, Nagoya University Nagoya Japan
3 shared publications - Kanoko Kurihara
Geochemical Research Center, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
2 shared publications - Kota Yamamoto
Regulatory Standard and Research Department, Secretariat of Nuclear Regulation Authority (S/NRA/R), Roppongi 1-9-9, Minato-ku, Tokyo 106-8450, Japan
2 shared publications
Latest Publications
- 17 March 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1713-1720
Uncertainties in isotopic ratio measurements of individual silver nanoparticles using multiple-collector ICP-mass spectrometry
In this study, measurement uncertainties for isotopic ratio analysis of individual Ag NPs were evaluated using MC-ICP-MS with high-gain Faraday amplifiers.
- 17 March 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1713-1720
Uncertainties in isotopic ratio measurements of individual silver nanoparticles using multiple-collector ICP-mass spectrometry
In this study, measurement uncertainties for isotopic ratio analysis of individual Ag NPs were evaluated using MC-ICP-MS with high-gain Faraday amplifiers.
- 9 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (2) , 518-524
A reaction cell as a sample introduction portal for detection of gaseous components in ICP-MS
The detection of gaseous elements (He, Ne, Kr, and Xe) and molecules (CO2, CH4, and NH3) using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) is described.
- 9 December 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 39 (2) , 518-524
A reaction cell as a sample introduction portal for detection of gaseous components in ICP-MS
The detection of gaseous elements (He, Ne, Kr, and Xe) and molecules (CO2, CH4, and NH3) using inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS) is described.
- Open Access
- 28 June 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (13) , 1958
Size Uncertainty in Individual Nanoparticles Measured by Single Particle Inductively Coupled Plasma Mass Spectrometry
Single particle inductively coupled plasma mass spectrometry has been used for size measurements of individual nanoparticles (NPs). Here, uncertainties in size analysis based upon two calibration approaches were evaluated: (i) the use of particle size standard and (ii) the use of ion standard solution. For particle size standard approach, the source of uncertainty to determine the target NP diameter was related to the variation in the signal intensities of both target NPs and particle size standard, and the size distribution of the particle size standard. The relative uncertainties of the 50 nm silver NP as the target were 15.0%, 9.9%, and 10.8% when particle size standards of 30 nm, 60 nm, and 100 nm silver NPs were used, respectively. As for the ion standard solution approach, the sources of uncertainty were the concentration of working standard solution, sample flow rate, transport efficiency, slope of calibration curve, and variation in the signal intensity of the ion standard solution and of the target NPs. The relative uncertainties for the 50 nm silver NP were 18.5% for 1 ng/g, 7.6% for 10 ng/g, and 4.7% for 100 ng/g solutions. The lower uncertainty obtained with a high concentration working standard solution is recommended to improve precision on particle size determinations by spICP-MS.
- 28 June 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (13) , 1958
Open AccessSize Uncertainty in Individual Nanoparticles Measured by Single Particle Inductively Coupled Plasma Mass Spectrometry
Single particle inductively coupled plasma mass spectrometry has been used for size measurements of individual nanoparticles (NPs). Here, uncertainties in size analysis based upon two calibration approaches were evaluated: (i) the use of particle size standard and (ii) the use of ion standard solution. For particle size standard approach, the source of uncertainty to determine the target NP diameter was related to the variation in the signal intensities of both target NPs and particle size standard, and the size distribution of the particle size standard. The relative uncertainties of the 50 nm silver NP as the target were 15.0%, 9.9%, and 10.8% when particle size standards of 30 nm, 60 nm, and 100 nm silver NPs were used, respectively. As for the ion standard solution approach, the sources of uncertainty were the concentration of working standard solution, sample flow rate, transport efficiency, slope of calibration curve, and variation in the signal intensity of the ion standard solution and of the target NPs. The relative uncertainties for the 50 nm silver NP were 18.5% for 1 ng/g, 7.6% for 10 ng/g, and 4.7% for 100 ng/g solutions. The lower uncertainty obtained with a high concentration working standard solution is recommended to improve precision on particle size determinations by spICP-MS.
- Open Access
- 6 April 2023
- Published by The Mass Spectrometry Society of Japan in Mass Spectrometry
- Vol. 12 (1) , A0116
Size Analysis of Silver and Gold Nanoparticles Using Laser Ablation Single Particle ICP Mass Spectrometry: Evaluation of the Laser-Induced Disintegration of Nanoparticles
Single particle inductively coupled plasma mass spectrometry combined with the laser ablation technique (LA-spICP-MS) has been used for the determination of particle size and the spatial distribution of metal nanoparticles (MNPs) in various solid samples such as biological samples and semiconductor materials. In this study, we investigated the effect of the fluence of the laser being used on the disintegration of MNPs. Commercially available MNPs of silver and gold (Ag NPs and Au NPs), the sizes of which were determined by transmission electron microscopy (TEM), were analyzed with LA-spICP-MS. We evaluated the degree of disintegration of the original-sized particles, based on a comparison of the size distributions obtained by LA-spICP-MS and other analytical techniques. The disintegration of both the Ag NPs and Au NPs was induced by a laser ablation process when the laser fluence was higher than 1.0 J cm−2, whereas no disintegration was observed when the fluence was lower than 1.0 J cm−2. Moreover, the mean diameter and standard deviation of the determined diameters obtained by LA-spICP-MS were in good agreement with solution-based spICP-MS and TEM analysis within analytical uncertainty. The data obtained here demonstrates that LA-spICP-MS represents a promising potential analytical technique for accurately determining the size of individual MNPs and their spatial distribution in solid samples.
- 6 April 2023
- Published by The Mass Spectrometry Society of Japan in Mass Spectrometry
- Vol. 12 (1) , A0116
Open AccessSize Analysis of Silver and Gold Nanoparticles Using Laser Ablation Single Particle ICP Mass Spectrometry: Evaluation of the Laser-Induced Disintegration of Nanoparticles
Single particle inductively coupled plasma mass spectrometry combined with the laser ablation technique (LA-spICP-MS) has been used for the determination of particle size and the spatial distribution of metal nanoparticles (MNPs) in various solid samples such as biological samples and semiconductor materials. In this study, we investigated the effect of the fluence of the laser being used on the disintegration of MNPs. Commercially available MNPs of silver and gold (Ag NPs and Au NPs), the sizes of which were determined by transmission electron microscopy (TEM), were analyzed with LA-spICP-MS. We evaluated the degree of disintegration of the original-sized particles, based on a comparison of the size distributions obtained by LA-spICP-MS and other analytical techniques. The disintegration of both the Ag NPs and Au NPs was induced by a laser ablation process when the laser fluence was higher than 1.0 J cm−2, whereas no disintegration was observed when the fluence was lower than 1.0 J cm−2. Moreover, the mean diameter and standard deviation of the determined diameters obtained by LA-spICP-MS were in good agreement with solution-based spICP-MS and TEM analysis within analytical uncertainty. The data obtained here demonstrates that LA-spICP-MS represents a promising potential analytical technique for accurately determining the size of individual MNPs and their spatial distribution in solid samples.
- Open Access
- 1 January 2023
- Published by Geochemical Society of Japan in GEOCHEMICAL JOURNAL
- Vol. 57 (5) , e9-e16
Elemental and isotopic signatures of individual particles in chondrite matrix using inductively coupled plasma mass spectrometry
Elemental and isotopic analyses of individual submicron-sized particles in chondrite matrix were made by an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOF-MS) and a multiple collector-ICP-MS equipped with high-time resolution ion counters (HTR-MC-ICP-MS). The particles were collected from Allende CV3 chondrite through a laser ablation-in-liquid (LAL) technique. Firstly, the abundances for four major elements (Si, Al, Mg, and Fe) were determined on total 6086 particles, indicating that the Allende matrix is a mixture of submicron-sized particles made mainly of olivine, pyroxene, spinel, Fe–Ni sulfide and Fe–Ni metal, consistent with the predicted major constituent minerals by nebular condensation model. The major elemental compositions revealed that Fe–Ni particles are minor components (about 0.3% in number fraction) in the Allende matrix. Then, to estimate the origin of these metallic particles, abundances for Ni and two minor elements (Os and Pt) were measured. Total 10417 particles of Ni–Os–Pt bearing particles were also found in the chondrite matrix. Majority of the particles were enriched in Ni. Os and Pt were present as separated particles, and no particles with presence of both the Os and Pt were found. Finally, with the HTR-MC-ICP-MS technique, 195Pt/194Pt value was measured on total 1545 particles. The resulting 195Pt/194Pt value agreed with the solar composition within analytical uncertainties. This lack in isotopic anomalies of the 195Pt/194Pt can be explained either by majority of the Pt nuggets being produced from uniform reservoir in the solar system or by Pt being isotopically homogenized prior to the formation of the solar nebula.
- 1 January 2023
- Published by Geochemical Society of Japan in GEOCHEMICAL JOURNAL
- Vol. 57 (5) , e9-e16
Open AccessElemental and isotopic signatures of individual particles in chondrite matrix using inductively coupled plasma mass spectrometry
Elemental and isotopic analyses of individual submicron-sized particles in chondrite matrix were made by an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOF-MS) and a multiple collector-ICP-MS equipped with high-time resolution ion counters (HTR-MC-ICP-MS). The particles were collected from Allende CV3 chondrite through a laser ablation-in-liquid (LAL) technique. Firstly, the abundances for four major elements (Si, Al, Mg, and Fe) were determined on total 6086 particles, indicating that the Allende matrix is a mixture of submicron-sized particles made mainly of olivine, pyroxene, spinel, Fe–Ni sulfide and Fe–Ni metal, consistent with the predicted major constituent minerals by nebular condensation model. The major elemental compositions revealed that Fe–Ni particles are minor components (about 0.3% in number fraction) in the Allende matrix. Then, to estimate the origin of these metallic particles, abundances for Ni and two minor elements (Os and Pt) were measured. Total 10417 particles of Ni–Os–Pt bearing particles were also found in the chondrite matrix. Majority of the particles were enriched in Ni. Os and Pt were present as separated particles, and no particles with presence of both the Os and Pt were found. Finally, with the HTR-MC-ICP-MS technique, 195Pt/194Pt value was measured on total 1545 particles. The resulting 195Pt/194Pt value agreed with the solar composition within analytical uncertainties. This lack in isotopic anomalies of the 195Pt/194Pt can be explained either by majority of the Pt nuggets being produced from uniform reservoir in the solar system or by Pt being isotopically homogenized prior to the formation of the solar nebula.
- 3 December 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (1) , 178-184
Size and isotopic ratio measurements of individual nanoparticles by a continuous ion-monitoring method using Faraday detectors equipped on a multi-collector-ICP-mass spectrometer
We investigated the capability of high-gain Faraday detectors equipped on a multi-collector-ICP-mass spectrometer (MFC-ICP-MS) in performing both particle size and Ag isotopic ratio determination for individual silver nanoparticles (Ag NPs). Two high-gain Faraday detectors equipped with 1013 Ω resistors were used to detect transient signals emanating from individual NPs (particle events). A continuous ion-monitoring method (CIM) was adopted to obtain reliable isotopic ratio data from the particle events. The CIM measurements of the signal intensities obtained from Ag NPs (40, 60, 80, 100, and 200 nm) exhibited a good linearity with the sizes of the Ag NPs. The variations of the measured 109Ag/107Ag ratio for the particles of each size in the isotopic ratio measurements (about 100 particles sampled per size) were about: 12% for 40 nm, 4.9% for 60 nm, 1.9% for 80 nm, 1.2% for 100 nm, and 0.26% for 200 nm. The resulting precision of the 109Ag/107Ag ratio measurements can be basically attributed to both shot noise (counting statistics) and background fluctuation on amplifiers. The data obtained here demonstrated that the MFC-ICP-MS system combined with the CIM can be employed to determine both the NP size and isotopic ratio of constituent elements.
- 3 December 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (1) , 178-184
Size and isotopic ratio measurements of individual nanoparticles by a continuous ion-monitoring method using Faraday detectors equipped on a multi-collector-ICP-mass spectrometer
We investigated the capability of high-gain Faraday detectors equipped on a multi-collector-ICP-mass spectrometer (MFC-ICP-MS) in performing both particle size and Ag isotopic ratio determination for individual silver nanoparticles (Ag NPs). Two high-gain Faraday detectors equipped with 1013 Ω resistors were used to detect transient signals emanating from individual NPs (particle events). A continuous ion-monitoring method (CIM) was adopted to obtain reliable isotopic ratio data from the particle events. The CIM measurements of the signal intensities obtained from Ag NPs (40, 60, 80, 100, and 200 nm) exhibited a good linearity with the sizes of the Ag NPs. The variations of the measured 109Ag/107Ag ratio for the particles of each size in the isotopic ratio measurements (about 100 particles sampled per size) were about: 12% for 40 nm, 4.9% for 60 nm, 1.9% for 80 nm, 1.2% for 100 nm, and 0.26% for 200 nm. The resulting precision of the 109Ag/107Ag ratio measurements can be basically attributed to both shot noise (counting statistics) and background fluctuation on amplifiers. The data obtained here demonstrated that the MFC-ICP-MS system combined with the CIM can be employed to determine both the NP size and isotopic ratio of constituent elements.
- 7 October 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (1) , 70-74
Uranium–lead isotopic analysis from transient signals using high-time resolution-multiple collector-ICP-MS (HTR-MC-ICP-MS)
206 Pb/ 238 U isotopic ratios were measured from transient signals produced by laser ablation for a short time period (4 shots with 60 kHz repetition rates).
- 7 October 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (1) , 70-74
Uranium–lead isotopic analysis from transient signals using high-time resolution-multiple collector-ICP-MS (HTR-MC-ICP-MS)
206 Pb/ 238 U isotopic ratios were measured from transient signals produced by laser ablation for a short time period (4 shots with 60 kHz repetition rates).
- 4 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (12) , 2834-2839
Size analysis of large-sized gold nanoparticles using single particle ICP-mass spectrometry
Single particle ICP-mass spectrometry (spICP-MS) has been used to define the size and number concentration of nanoparticles (NPs). In this study, we have developed a new analytical approach to extend the analytical size range of NPs toward a larger region. To achieve this, the signal intensities of Au related polyatomic ions such as 197Au12C+, 197Au14N+, 197Au16O+, and 197Au40Ar+, instead of 197Au+, were used for the size calibration of Au NPs. With the 197Au40Ar+ signal, the signal intensities emanating from the Au NPs can be reduced to the 10−5 level, and thus, the resulting signal intensity for 400 nm Au NPs was about 1 000 000 cps, which was well within the analytical range. For the size analysis of Au NPs of size 200–400 nm, the intensity of the 197Au40Ar+ signal was used, whilst, the 197Au+ signal was used for the size calibration for Au NPs of size 10–100 nm. The reliability of the technique can be evaluated from the slope of the regression line defined by NPs of three sizes (200, 300, and 400 nm). The wider analytical range achieved here (i.e., 10–400 nm) shows that this technique can be applied for the size analysis of NPs present in nature.
- 4 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 35 (12) , 2834-2839
Size analysis of large-sized gold nanoparticles using single particle ICP-mass spectrometry
Single particle ICP-mass spectrometry (spICP-MS) has been used to define the size and number concentration of nanoparticles (NPs). In this study, we have developed a new analytical approach to extend the analytical size range of NPs toward a larger region. To achieve this, the signal intensities of Au related polyatomic ions such as 197Au12C+, 197Au14N+, 197Au16O+, and 197Au40Ar+, instead of 197Au+, were used for the size calibration of Au NPs. With the 197Au40Ar+ signal, the signal intensities emanating from the Au NPs can be reduced to the 10−5 level, and thus, the resulting signal intensity for 400 nm Au NPs was about 1 000 000 cps, which was well within the analytical range. For the size analysis of Au NPs of size 200–400 nm, the intensity of the 197Au40Ar+ signal was used, whilst, the 197Au+ signal was used for the size calibration for Au NPs of size 10–100 nm. The reliability of the technique can be evaluated from the slope of the regression line defined by NPs of three sizes (200, 300, and 400 nm). The wider analytical range achieved here (i.e., 10–400 nm) shows that this technique can be applied for the size analysis of NPs present in nature.
- 1 November 2019
- Published by Elsevier in European Polymer Journal
- Vol. 120, 109185
Synthesis of poly(conjugated ester)s by ring-opening polymerization of cyclic hemiacetal ester bearing acryl skeleton
- 1 November 2019
- Published by Elsevier in European Polymer Journal
- Vol. 120, 109185
Synthesis of poly(conjugated ester)s by ring-opening polymerization of cyclic hemiacetal ester bearing acryl skeleton