Kota Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kota Yamamoto has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Takafumi Hirata
Geochemical Research Center, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
4 shared publications - Hisashi Asanuma
Department of Earth Science and Astronomy The University of Tokyo Tokyo Japan
2 shared publications - Shuji Yamashita
Geochemical Research Center, The University of Tokyo
2 shared publications Hiroaki Takahashi
Regulatory Standard and Research Department, Secretariat of Nuclear Regulation Authority (S/NRA/R), Roppongi 1-9-9, Minato-ku, Tokyo, 106-8450, Japan
1 shared publication- Hiroaki Takahashi
Regulatory Standard and Research Department Secretariat of Nuclear Regulation Authority (S/NRA/R) Tokyo Japan
1 shared publication Yuta Kemuyama
Geochemical Research Center, Graduate School of Science, The University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-0033, Japan
1 shared publication
Latest Publications
- 17 March 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1713-1720
Uncertainties in isotopic ratio measurements of individual silver nanoparticles using multiple-collector ICP-mass spectrometry
In this study, measurement uncertainties for isotopic ratio analysis of individual Ag NPs were evaluated using MC-ICP-MS with high-gain Faraday amplifiers.
- 17 March 2026
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 41 (5) , 1713-1720
Uncertainties in isotopic ratio measurements of individual silver nanoparticles using multiple-collector ICP-mass spectrometry
In this study, measurement uncertainties for isotopic ratio analysis of individual Ag NPs were evaluated using MC-ICP-MS with high-gain Faraday amplifiers.
- 14 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (5) , 1076-1083
A new gain calibration protocol for Faraday amplifiers equipped with a 1013 Ω resistor
A new calibration method (roundabout method) was developed to precisely determine the amplification gains of 1013 Ω Faraday detectors.
- 14 March 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (5) , 1076-1083
A new gain calibration protocol for Faraday amplifiers equipped with a 1013 Ω resistor
A new calibration method (roundabout method) was developed to precisely determine the amplification gains of 1013 Ω Faraday detectors.
- 3 December 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (1) , 178-184
Size and isotopic ratio measurements of individual nanoparticles by a continuous ion-monitoring method using Faraday detectors equipped on a multi-collector-ICP-mass spectrometer
We investigated the capability of high-gain Faraday detectors equipped on a multi-collector-ICP-mass spectrometer (MFC-ICP-MS) in performing both particle size and Ag isotopic ratio determination for individual silver nanoparticles (Ag NPs). Two high-gain Faraday detectors equipped with 1013 Ω resistors were used to detect transient signals emanating from individual NPs (particle events). A continuous ion-monitoring method (CIM) was adopted to obtain reliable isotopic ratio data from the particle events. The CIM measurements of the signal intensities obtained from Ag NPs (40, 60, 80, 100, and 200 nm) exhibited a good linearity with the sizes of the Ag NPs. The variations of the measured 109Ag/107Ag ratio for the particles of each size in the isotopic ratio measurements (about 100 particles sampled per size) were about: 12% for 40 nm, 4.9% for 60 nm, 1.9% for 80 nm, 1.2% for 100 nm, and 0.26% for 200 nm. The resulting precision of the 109Ag/107Ag ratio measurements can be basically attributed to both shot noise (counting statistics) and background fluctuation on amplifiers. The data obtained here demonstrated that the MFC-ICP-MS system combined with the CIM can be employed to determine both the NP size and isotopic ratio of constituent elements.
- 3 December 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (1) , 178-184
Size and isotopic ratio measurements of individual nanoparticles by a continuous ion-monitoring method using Faraday detectors equipped on a multi-collector-ICP-mass spectrometer
We investigated the capability of high-gain Faraday detectors equipped on a multi-collector-ICP-mass spectrometer (MFC-ICP-MS) in performing both particle size and Ag isotopic ratio determination for individual silver nanoparticles (Ag NPs). Two high-gain Faraday detectors equipped with 1013 Ω resistors were used to detect transient signals emanating from individual NPs (particle events). A continuous ion-monitoring method (CIM) was adopted to obtain reliable isotopic ratio data from the particle events. The CIM measurements of the signal intensities obtained from Ag NPs (40, 60, 80, 100, and 200 nm) exhibited a good linearity with the sizes of the Ag NPs. The variations of the measured 109Ag/107Ag ratio for the particles of each size in the isotopic ratio measurements (about 100 particles sampled per size) were about: 12% for 40 nm, 4.9% for 60 nm, 1.9% for 80 nm, 1.2% for 100 nm, and 0.26% for 200 nm. The resulting precision of the 109Ag/107Ag ratio measurements can be basically attributed to both shot noise (counting statistics) and background fluctuation on amplifiers. The data obtained here demonstrated that the MFC-ICP-MS system combined with the CIM can be employed to determine both the NP size and isotopic ratio of constituent elements.
- 17 February 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (3) , 668-675
In situ isotopic analysis of uranium using a new data acquisition protocol for 10 13 ohm Faraday amplifiers
Isotopic ratio measurements for 235U/238U and 234U/238U ratios were made for a series of solid materials using laser ablation multiple collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). To extend the dynamic range of the isotopic ratio measurements, three Faraday detectors with different amplification gains (amplifiers with 1011 and 1013 ohm resistors) were employed. To reduce the sampling volume, isotopic ratio measurements were made on transient signals obtained by short-time LA duration (235U/238U ratios were approximately 3% higher than values noted in the literature when a conventional tau correction technique was employed. This was mainly due to incomplete correction of the slow response of the Faraday amplifiers. To overcome this, continuous ion-monitoring, rather than tau correction, was applied to the isotopic ratio measurements from the transient signals. Typical precision for the 235U/238U and 234U/238U ratio measurements were 1‰ and 7% (2SD), respectively, and the resulting 235U/238U ratios for zircons and glass materials showed good agreement with values observed in the literature. The isotopic ratio measurements revealed heterogeneity of 235U/238U ratios among titanite grains. The measured 234U/238U ratios were consistent with the value of the secular equilibrium in the 238U series, except for FCT titanite. Herein, a possible cause for the discrepancy in the measured 234U/238U ratio in the secular equilibrium is discussed. The data obtained in this study demonstrate that the present data acquisition protocol can serve as a benchmark technique for isotopic ratio measurements derived from transient signals using Faraday detectors, particularly when using high-gain (e.g. 1013 ohm resistors) amplifiers.
- 17 February 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (3) , 668-675
In situ isotopic analysis of uranium using a new data acquisition protocol for 10 13 ohm Faraday amplifiers
Isotopic ratio measurements for 235U/238U and 234U/238U ratios were made for a series of solid materials using laser ablation multiple collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). To extend the dynamic range of the isotopic ratio measurements, three Faraday detectors with different amplification gains (amplifiers with 1011 and 1013 ohm resistors) were employed. To reduce the sampling volume, isotopic ratio measurements were made on transient signals obtained by short-time LA duration (235U/238U ratios were approximately 3% higher than values noted in the literature when a conventional tau correction technique was employed. This was mainly due to incomplete correction of the slow response of the Faraday amplifiers. To overcome this, continuous ion-monitoring, rather than tau correction, was applied to the isotopic ratio measurements from the transient signals. Typical precision for the 235U/238U and 234U/238U ratio measurements were 1‰ and 7% (2SD), respectively, and the resulting 235U/238U ratios for zircons and glass materials showed good agreement with values observed in the literature. The isotopic ratio measurements revealed heterogeneity of 235U/238U ratios among titanite grains. The measured 234U/238U ratios were consistent with the value of the secular equilibrium in the 238U series, except for FCT titanite. Herein, a possible cause for the discrepancy in the measured 234U/238U ratio in the secular equilibrium is discussed. The data obtained in this study demonstrate that the present data acquisition protocol can serve as a benchmark technique for isotopic ratio measurements derived from transient signals using Faraday detectors, particularly when using high-gain (e.g. 1013 ohm resistors) amplifiers.