CGChristof Gaiser

Christof Gaiser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christof Gaiser has a total of 103 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Future traceability of practical primary thermometry and self-validating thermometry

    by Jonathan Pearce, Graham Machin, Andrew Todd, Maria Jose Martin, Yijie Pan, Kunli Zhou, Åge Olsen, Aleksandra Kowal, Christof Gaiser, Yasuki Kawamura, et al.

    Many new techniques for ensuring traceable temperature measurements at the point of use are being developed and some are approaching maturity. The aim of this study is to examine the formalism associated with traceability to the SI kelvin for these practical techniques, as well as to identify areas of research which should be a priority. First, the status quo of thermodynamic temperature realization and dissemination is summarized. Then the state of the art of two main types of thermometry which can potentially provide in situ traceability is discussed. These are self-validating thermometers which make use of the phase change of materials, and practical primary thermometers, examples of which are given in order of decreasing commercial readiness: relative primary radiometry, acoustic gas thermometry (AGT), Johnson noise thermometry (JNT) and Doppler broadening thermometry (DBT). It is shown that relative primary thermometry is, in general, much more likely to become a day-to-day practical reality than absolute primary thermometry, and that this has a significant bearing on what the formalism might look like regarding metrological traceability and demonstrations of equivalence. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.


  • Open Access

    Challenges of primary thermometry above 300 K

    by Christof Gaiser, Bernd Fellmuth

    Historically, the realization of the base unit kelvin was exclusively possible via International Temperature Scales (ITS). The new definition of the kelvin and the accompanying Mise en Pratique of the kelvin (MeP-K) enables the alternative to use primary thermometry for the realization of the kelvin. During the last years, considerable improvements in primary thermometry in the low-temperature range have been achieved. Thereby, above 300 K, still a lot of work is necessary to be competitive with the existing ITS realization. In this contribution, the interplay between primary thermometry, ITS and scale carriers (platinum resistance thermometers, thermocouples) in a historical perspective is sketched. After a short introduction to primary thermometry in general and the established techniques within the MeP-K, the focus will lie on the challenges connected with thermodynamic temperature measurement above 300 K. The advantages and disadvantages of the different techniques will be discussed briefly, and a summary will be given showing that thermodynamic temperature T, TITS and scale carriers are highly connected and improvement in one field relies on improvement in the others. The background of the discussion will be the deficiencies of the existing ITS and thus the requirements for the temperature-measurement community. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.

  • Open Access

    Primary thermometry below 25 K: a decade of low-uncertainty measurements linked to the new kelvin

    by Bo Gao, Haiyang Zhang, Xiangjie Kong, Wenxiang Guo, Yaonan Song, Siqi Liu, Fernando Sparasci, Clement Tauzin, Jiaxi Zheng, Laurent Pitre, et al.

    In 2019, the basic unit of thermodynamic temperature, the kelvin, was redefined by fixing the value of the Boltzmann constant, opening new avenues for implementing and disseminating the kelvin with lower uncertainty, especially at temperatures below 25 K. In response, the Mise en Pratique for the definition of the kelvin (MeP-K) (2019) has recommended several primary thermometry methods, including acoustic gas thermometry (AGT), dielectric-constant gas thermometry (DCGT), refractive index gas thermometry (RIGT) and Johnson noise thermometry (JNT), as viable alternatives for realizing and disseminating the kelvin. Since the International System of Units (SI) revolution, significant progress on implementing the new kelvin has been made below 25 K. This progress indicates that primary thermometry, particularly its relative variants, can offer promising practical options for realizing and disseminating thermodynamic temperature directly linking to the new kelvin below 25 K with lower uncertainty. This is very important for metrological applications of science and industry, which require precise and accurate temperature calibrations. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.

  • Differences Between Thermodynamic Temperature and ITS-90 Below 4.2 K

    by B. Fellmuth, C. Gaiser

    Recommended values are given for the difference between the thermodynamic temperature T and T90, the temperature on the International Temperature Scale of 1990, for temperatures below 4.2 K. The recommendations are based on a combination of primary thermometry and thermodynamic calculations. Functions for both the difference T − T90 and its uncertainty are provided.


  • Open Access

    Practical realisation of the kelvin by Johnson noise thermometry

    by Samuel P Benz, Kevin J Coakley, Nathan E Flowers-Jacobs, Horst Rogalla, Weston L Tew, Jifeng Qu, D Rod White, Christof Gaiser, Alessio Pollarolo, Chiharu Urano

    Johnson noise thermometry (JNT) is a purely electronic method of thermodynamic thermometry. In primary JNT, the temperature is inferred from a comparison of the Johnson noise voltage of a resistor at the unknown temperature with a pseudo-random noise synthesized by a quantum-based voltage-noise source (QVNS). The advantages of the method are that it relies entirely on electronic measurements, and it can be used over a wide range of temperatures due to the ability of the QVNS to generate programmable, scalable, and accurate reference signals. The disadvantages are the requirement of cryogenic operation of the QVNS, the need to match the frequency responses of the leads of the sense resistor and the QVNS, and long measurement times. This review collates advice on current best practice for a primary JNT based on the switched correlator and QVNS. The method achieves an uncertainty of about 1 mK near 300 K and is suited to operation between 4 K and 1000 K.


  • Updated differences between thermodynamic and ITS-90 temperature - A pathway to improvements in metrology and beyond

    by C. Gaiser, B. Fellmuth

    In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T

  • Top Cited Papers
    Open Access

    Ab Initio Calculation of Fluid Properties for Precision Metrology

    by Giovanni Garberoglio, Christof Gaiser, Roberto M. Gavioso, Allan H. Harvey, Robert Hellmann, Bogumił Jeziorski, Karsten Meier, Michael R. Moldover, Laurent Pitre, Krzysztof Szalewicz, et al.

    Recent advances regarding the interplay between ab initio calculations and metrology are reviewed, with particular emphasis on gas-based techniques used for temperature and pressure measurements. Since roughly 2010, several thermophysical quantities – in particular, virial and transport coefficients – can be computed from first principles without uncontrolled approximations and with rigorously propagated uncertainties. In the case of helium, computational results have accuracies that exceed the best experimental data by at least one order of magnitude and are suitable to be used in primary metrology. The availability of ab initio virial and transport coefficients contributed to the recent SI definition of temperature by facilitating measurements of the Boltzmann constant with unprecedented accuracy. Presently, they enable the development of primary standards of thermodynamic temperature in the range 2.5–552 K and pressure up to 7 MPa using acoustic gas thermometry, dielectric constant gas thermometry, and refractive index gas thermometry. These approaches will be reviewed, highlighting the effect of first-principles data on their accuracy. The recent advances in electronic structure calculations that enabled highly accurate solutions for the many-body interaction potentials and polarizabilities of atoms – particularly helium – will be described, together with the subsequent computational methods, most often based on quantum statistical mechanics and its path-integral formulation, that provide thermophysical properties and their uncertainties. Similar approaches for molecular systems, and their applications, are briefly discussed. Current limitations and expected future lines of research are assessed.


  • Open Access

    High-accuracy realization of temperature fixed and reference points

    by Bernd Fellmuth, Christof Gaiser

    The harmonization of international temperature measurements requires the high-accuracy realization of many different temperature reference points. This results from the feature of the intensive measurand temperature that temperatures cannot simply be divided or multiplied. Thus, the points must cover the whole range of interest, at present from 1 mK to a few 1000 K. Furthermore, instruments are necessary for the interpolation between the non-continuous guide values. This led to the establishment of International Temperature Scales (ITS). The ITS prescribe interpolation instruments and assign fixed temperature values to suitable phase transitions without uncertainty. The large temperature range can only be covered by applying very different phase transitions. This includes the classical transitions, namely triple, melting, and freezing points, but also second-order transitions, as superfluid and superconducting ones, and the very new eutectic or peritectic points of metal-carbon compositions. A high-accuracy realization requires a reliable uncertainty estimation. This is, therefore, the central topic of this review. Since a given non-ideal condition of a sample, especially the impurity content, cannot be reproduced as accurate as necessary, the fixed- and reference-point temperatures are defined for ideal substances under ideal conditions. Thus, the estimation of the uncertainty of the realizations must be based on estimating the magnitude of all physical effects influencing the observed phase-transition temperature. The application of this methodology is discussed in the paper as unifying topic independent of the individual problems to be solved. Furthermore, recommendations of the Consultative Committee for Thermometry are summarized, and own experiences are supplemented.