Roberto Maria Gavioso
Roberto Maria Gavioso has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Dario Imbraguglio
Istituto Nazionale di Ricerca Metrologica 1
6 shared publications - Laurent Pitre
TIPC-LNE Joint Laboratory on Cryogenic Metrology Science and Technology, Technical Institute of Physics and Chemistry (TIPC), Chinese Academy of Sciences (CAS), Beijing 100190, People’s Republic of China
6 shared publications - Daniele Madonna Ripa
Joint Research Laboratory for Fluid Metrology Evangelista Torricelli Between LNE and INRiM, France and Italy
5 shared publications - Petrus Paulus Maria Steur
Thermodynamicsl Department, Istituto Nazionale di Ricerca Metrologica, Strada Delle Cacce 91, Torino, 10135, ITALY
5 shared publications - Christof Gaiser
Physikalisch-Technische Bundesanstalt (PTB) , Braunschweig
4 shared publications - Fernando Sparasci
LNE-Cnam, Paris, France
4 shared publications
Latest Publications
- Open Access
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Dissemination of thermodynamic temperature by gas thermometry below 300 K
The redefinition of the kelvin motivates the realization of thermodynamic temperature standards and their improvement up to the stage where they become sufficiently accurate, reliable and practically useful for the purpose of disseminating the unit by direct calibration of temperature sensors. We review progress milestones in the development of gas-based primary thermometry methods, assess their current state of the art and discuss the remaining challenges and the perspectives of using thermodynamic methods as an alternative to traditional dissemination based on the realization of the International Temperature Scale. We give an account of research initiatives which are underway to test the maturity of this perspective, including an international blind comparison of thermodynamic calibrations of capsule-type resistance thermometers using different methods of primary gas thermometry in the range 4 to 300 K. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Open AccessDissemination of thermodynamic temperature by gas thermometry below 300 K
The redefinition of the kelvin motivates the realization of thermodynamic temperature standards and their improvement up to the stage where they become sufficiently accurate, reliable and practically useful for the purpose of disseminating the unit by direct calibration of temperature sensors. We review progress milestones in the development of gas-based primary thermometry methods, assess their current state of the art and discuss the remaining challenges and the perspectives of using thermodynamic methods as an alternative to traditional dissemination based on the realization of the International Temperature Scale. We give an account of research initiatives which are underway to test the maturity of this perspective, including an international blind comparison of thermodynamic calibrations of capsule-type resistance thermometers using different methods of primary gas thermometry in the range 4 to 300 K. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- Open Access
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Direct calibration of resistance thermometers between 10 K and 25 K by absolute acoustic gas thermometry in helium
We have implemented absolute acoustic gas thermometry at 10 K, 13.8 K, 19 K and 24.6 K to evaluate the performance of this primary method for the direct thermodynamic calibration of capsule-type resistance thermometers, including both platinum and rhodium-iron types. Our implementation is based on speed of sound measurements in helium at a single pressure, chosen in the range 65 to 130 kPa, with non-ideality corrections relying on accurate ab initio calculations of the thermodynamic properties. The overall accuracy achieved in the determination of the thermodynamic temperature T varies between a minimum of 0.1 mK at 13.8 K to a maximum of 0.2 mK at 24.6 K. From the acoustic results and the calibration of thermometers on the international temperature scale ITS-90 providing T90, we determined the differences (T−T90), finding them in good agreement with the 2022 consensus estimates within the combined uncertainties. These results include a determination of the thermodynamic temperature at the triple point of neon TNe = (24.55502 ± 0.00030) K. This new value of TNe is consistent with other recent determinations obtained with various primary methods. Finally, we provide an example of a rapid, yet accurate, simplified thermodynamic calibration procedure. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- 15 January 2026
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 384 (2312)
Open AccessDirect calibration of resistance thermometers between 10 K and 25 K by absolute acoustic gas thermometry in helium
We have implemented absolute acoustic gas thermometry at 10 K, 13.8 K, 19 K and 24.6 K to evaluate the performance of this primary method for the direct thermodynamic calibration of capsule-type resistance thermometers, including both platinum and rhodium-iron types. Our implementation is based on speed of sound measurements in helium at a single pressure, chosen in the range 65 to 130 kPa, with non-ideality corrections relying on accurate ab initio calculations of the thermodynamic properties. The overall accuracy achieved in the determination of the thermodynamic temperature T varies between a minimum of 0.1 mK at 13.8 K to a maximum of 0.2 mK at 24.6 K. From the acoustic results and the calibration of thermometers on the international temperature scale ITS-90 providing T90, we determined the differences (T−T90), finding them in good agreement with the 2022 consensus estimates within the combined uncertainties. These results include a determination of the thermodynamic temperature at the triple point of neon TNe = (24.55502 ± 0.00030) K. This new value of TNe is consistent with other recent determinations obtained with various primary methods. Finally, we provide an example of a rapid, yet accurate, simplified thermodynamic calibration procedure. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.
- Open Access
- 1 December 2025
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 54 (4)
Speed of sound in humid air: Accurate thermodynamic model and experimental validation
We present a thermodynamic model of speed of sound w in humid air as a function of the parameters of influence, namely temperature T, pressure p, relative humidity hr, carbon dioxide concentration xCO2, and acoustic frequency f. The validity of the model extends between 200 K and 647 K, for pressures up to 10 MPa. By implementing the most accurate thermodynamic information currently available for dry air, water vapor, and their interaction, including heat capacities, virial coefficients, and relaxation parameters, the model revises and updates the most complete previous correlation [A. J. Zuckerwar, Handbook of the Speed of Sound in Real Gases – Volume III Speed of Sound in Air (Academic Press, London, 2002)], reducing its relative standard uncertainty by more than one order of magnitude, down to 25 ppm at ordinary, near-ambient conditions. The software implementation of the model is made available by publication of source and executable files. To test the validity of the model and its practical application, we have measured the speed of sound in humid air near ambient pressure using an acoustic wavelength meter set up in a hemi-anechoic chamber and compared a subset of these experimental determinations with those obtained by flowing air, sampled from the same environment, through a spherical resonator. The results from both experiments were found consistent with the model within their combined uncertainties. The positive outcome of the comparison suggests that acoustic thermometry in humid air may be realized at the level of 0.015 K with perspectives for application to dimensional measurements, temperature and acoustic metrology, and atmospheric physics.
- 1 December 2025
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 54 (4)
Open AccessSpeed of sound in humid air: Accurate thermodynamic model and experimental validation
We present a thermodynamic model of speed of sound w in humid air as a function of the parameters of influence, namely temperature T, pressure p, relative humidity hr, carbon dioxide concentration xCO2, and acoustic frequency f. The validity of the model extends between 200 K and 647 K, for pressures up to 10 MPa. By implementing the most accurate thermodynamic information currently available for dry air, water vapor, and their interaction, including heat capacities, virial coefficients, and relaxation parameters, the model revises and updates the most complete previous correlation [A. J. Zuckerwar, Handbook of the Speed of Sound in Real Gases – Volume III Speed of Sound in Air (Academic Press, London, 2002)], reducing its relative standard uncertainty by more than one order of magnitude, down to 25 ppm at ordinary, near-ambient conditions. The software implementation of the model is made available by publication of source and executable files. To test the validity of the model and its practical application, we have measured the speed of sound in humid air near ambient pressure using an acoustic wavelength meter set up in a hemi-anechoic chamber and compared a subset of these experimental determinations with those obtained by flowing air, sampled from the same environment, through a spherical resonator. The results from both experiments were found consistent with the model within their combined uncertainties. The positive outcome of the comparison suggests that acoustic thermometry in humid air may be realized at the level of 0.015 K with perspectives for application to dimensional measurements, temperature and acoustic metrology, and atmospheric physics.
- Open Access
- 11 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045007
Speed of sound measurements and derived third and fourth acoustic virial coefficients of supercritical neon
We report comprehensive and accurate measurements of the speed of sound in neon. These measurements were carried out by a double-path-length pulse-echo technique and cover the temperature range between 200 K and 420 K with pressures up to 100 MPa. The standard uncertainties are 1.9 mK in temperature, 22 parts in 106 in pressure and 35 parts in 106 in speed of sound. The third and fourth acoustic virial coefficients of neon were derived from the speed of sound data in the temperature range of the measurements by fitting a fourth-order acoustic virial expansion in pressure with the second acoustic virial coefficient constrained from first-principles calculations. To support our claimed uncertainty, we determined the ratio M / γ 0 between the molar mass M and the ideal-gas heat capacity ratio γ 0 of the neon sample with a relative standard uncertainty of 7.7 parts in 106 by additional speed of sound measurements using a spherical resonator at 273.16 K.
- 11 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045007
Open AccessSpeed of sound measurements and derived third and fourth acoustic virial coefficients of supercritical neon
We report comprehensive and accurate measurements of the speed of sound in neon. These measurements were carried out by a double-path-length pulse-echo technique and cover the temperature range between 200 K and 420 K with pressures up to 100 MPa. The standard uncertainties are 1.9 mK in temperature, 22 parts in 106 in pressure and 35 parts in 106 in speed of sound. The third and fourth acoustic virial coefficients of neon were derived from the speed of sound data in the temperature range of the measurements by fitting a fourth-order acoustic virial expansion in pressure with the second acoustic virial coefficient constrained from first-principles calculations. To support our claimed uncertainty, we determined the ratio M / γ 0 between the molar mass M and the ideal-gas heat capacity ratio γ 0 of the neon sample with a relative standard uncertainty of 7.7 parts in 106 by additional speed of sound measurements using a spherical resonator at 273.16 K.
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 020001
Progress with realizing the redefined Kelvin
The redefinition of the kelvin is introduced followed by an overview of progress made towards realizing the redefined kelvin with particular emphasis on using p The redefinition of the kelvin is introduced followed by an overview of progress made towards realizing the redefined kelvin with particular emphasis on using p
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 020001
Open AccessProgress with realizing the redefined Kelvin
The redefinition of the kelvin is introduced followed by an overview of progress made towards realizing the redefined kelvin with particular emphasis on using p The redefinition of the kelvin is introduced followed by an overview of progress made towards realizing the redefined kelvin with particular emphasis on using p
- Top Cited PapersOpen Access
- 1 September 2023
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 52 (3)
Ab Initio Calculation of Fluid Properties for Precision Metrology
Recent advances regarding the interplay between ab initio calculations and metrology are reviewed, with particular emphasis on gas-based techniques used for temperature and pressure measurements. Since roughly 2010, several thermophysical quantities – in particular, virial and transport coefficients – can be computed from first principles without uncontrolled approximations and with rigorously propagated uncertainties. In the case of helium, computational results have accuracies that exceed the best experimental data by at least one order of magnitude and are suitable to be used in primary metrology. The availability of ab initio virial and transport coefficients contributed to the recent SI definition of temperature by facilitating measurements of the Boltzmann constant with unprecedented accuracy. Presently, they enable the development of primary standards of thermodynamic temperature in the range 2.5–552 K and pressure up to 7 MPa using acoustic gas thermometry, dielectric constant gas thermometry, and refractive index gas thermometry. These approaches will be reviewed, highlighting the effect of first-principles data on their accuracy. The recent advances in electronic structure calculations that enabled highly accurate solutions for the many-body interaction potentials and polarizabilities of atoms – particularly helium – will be described, together with the subsequent computational methods, most often based on quantum statistical mechanics and its path-integral formulation, that provide thermophysical properties and their uncertainties. Similar approaches for molecular systems, and their applications, are briefly discussed. Current limitations and expected future lines of research are assessed.
- 1 September 2023
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 52 (3)
Top Cited PapersOpen AccessAb Initio Calculation of Fluid Properties for Precision Metrology
Recent advances regarding the interplay between ab initio calculations and metrology are reviewed, with particular emphasis on gas-based techniques used for temperature and pressure measurements. Since roughly 2010, several thermophysical quantities – in particular, virial and transport coefficients – can be computed from first principles without uncontrolled approximations and with rigorously propagated uncertainties. In the case of helium, computational results have accuracies that exceed the best experimental data by at least one order of magnitude and are suitable to be used in primary metrology. The availability of ab initio virial and transport coefficients contributed to the recent SI definition of temperature by facilitating measurements of the Boltzmann constant with unprecedented accuracy. Presently, they enable the development of primary standards of thermodynamic temperature in the range 2.5–552 K and pressure up to 7 MPa using acoustic gas thermometry, dielectric constant gas thermometry, and refractive index gas thermometry. These approaches will be reviewed, highlighting the effect of first-principles data on their accuracy. The recent advances in electronic structure calculations that enabled highly accurate solutions for the many-body interaction potentials and polarizabilities of atoms – particularly helium – will be described, together with the subsequent computational methods, most often based on quantum statistical mechanics and its path-integral formulation, that provide thermophysical properties and their uncertainties. Similar approaches for molecular systems, and their applications, are briefly discussed. Current limitations and expected future lines of research are assessed.
- Open Access
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 035112
Toward the realization of a primary low-pressure standard using a superconducting microwave resonator
We describe a primary gas pressure standard based on the measurement of the refractive index of helium gas using a microwave resonant cavity in the range between 500 Pa and 20 kPa. To operate in this range, the sensitivity of the microwave refractive gas manometer (MRGM) to low-pressure variations is substantially enhanced by a niobium coating of the resonator surface, which becomes superconducting at temperatures below 9 K, allowing one to achieve a frequency resolution of about 0.3 Hz at 5.2 GHz, corresponding to a pressure resolution below 3 mPa at 20 Pa. The determination of helium pressure requires precise thermometry but is favored by the remarkable accuracy achieved by ab initio calculations of the thermodynamic and electromagnetic properties of the gas. The overall standard uncertainty of the MRGM is estimated to be of the order of 0.04%, corresponding to 0.2 Pa at 500 and 8.1 Pa at 20 kPa, with major contributions from thermometry and the repeatability of microwave frequency measurements. A direct comparison of the pressures realized by the MRGM with the reference provided by a traceable quartz transducer shows relative pressure differences between 0.025% at 20 kPa and −1.4% at 500 Pa.
- 1 March 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (3) , 035112
Open AccessToward the realization of a primary low-pressure standard using a superconducting microwave resonator
We describe a primary gas pressure standard based on the measurement of the refractive index of helium gas using a microwave resonant cavity in the range between 500 Pa and 20 kPa. To operate in this range, the sensitivity of the microwave refractive gas manometer (MRGM) to low-pressure variations is substantially enhanced by a niobium coating of the resonator surface, which becomes superconducting at temperatures below 9 K, allowing one to achieve a frequency resolution of about 0.3 Hz at 5.2 GHz, corresponding to a pressure resolution below 3 mPa at 20 Pa. The determination of helium pressure requires precise thermometry but is favored by the remarkable accuracy achieved by ab initio calculations of the thermodynamic and electromagnetic properties of the gas. The overall standard uncertainty of the MRGM is estimated to be of the order of 0.04%, corresponding to 0.2 Pa at 500 and 8.1 Pa at 20 kPa, with major contributions from thermometry and the repeatability of microwave frequency measurements. A direct comparison of the pressures realized by the MRGM with the reference provided by a traceable quartz transducer shows relative pressure differences between 0.025% at 20 kPa and −1.4% at 500 Pa.
- Open Access
- 1 December 2022
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 51 (4) , 043105
2022 Update for the Differences Between Thermodynamic Temperature and ITS-90 Below 335 K
In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T and its approximation (T90), the temperature according to the International Temperature Scale of 1990, ITS-90. These consensus estimates, in combination with measurements made in accordance with ITS-90, are an important alternative to primary thermometry for those requiring accurate measurements of thermodynamic temperature. Since 2011, there has been a change in the definition of the kelvin and significant improvements in primary thermometry. This paper updates the (T − T90) estimates by combining and analyzing the data used for the 2011 estimates and data from more recent primary thermometry. The results of the analysis are presented as a 12th-order polynomial representing the updated consensus values for the differences and a sixth-order polynomial for their uncertainty estimates.
- 1 December 2022
- Published by AIP Publishing in Journal of Physical and Chemical Reference Data
- Vol. 51 (4) , 043105
Open Access2022 Update for the Differences Between Thermodynamic Temperature and ITS-90 Below 335 K
In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T and its approximation (T90), the temperature according to the International Temperature Scale of 1990, ITS-90. These consensus estimates, in combination with measurements made in accordance with ITS-90, are an important alternative to primary thermometry for those requiring accurate measurements of thermodynamic temperature. Since 2011, there has been a change in the definition of the kelvin and significant improvements in primary thermometry. This paper updates the (T − T90) estimates by combining and analyzing the data used for the 2011 estimates and data from more recent primary thermometry. The results of the analysis are presented as a 12th-order polynomial representing the updated consensus values for the differences and a sixth-order polynomial for their uncertainty estimates.
- Open Access
- 25 October 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (6) , 069501
Corrigendum: Refractive index gas thermometry between 13.8 K and 161.4 K (2021 Metrologia 58 025008)
- 25 October 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (6) , 069501
Open AccessCorrigendum: Refractive index gas thermometry between 13.8 K and 161.4 K (2021 Metrologia 58 025008)
- Open Access
- 9 July 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (4) , 045006
Acoustic measurement of the triple point of neon T Ne and thermodynamic calibration of a transfer standard for accurate cryogenic thermometry
We used absolute primary acoustic gas thermometry (AGT) to calibrate a Pt–Co resistance thermometer on the thermodynamic temperature scale by measuring the speed of sound in helium at a temperature T* chosen to be near the temperature of the triple point of neon, T Ne. Prior to the present AGT, the Pt–Co thermometer was used with a neon triple-point cell as part of an interlaboratory comparison. Taken together, the results of the interlaboratory comparison and the present AGT redetermined the thermodynamic temperature T Ne = (24.555 15 ± 0.000 24) K. This new value of T Ne is consistent with other recent determinations obtained with various primary methods. After completing the AGT thermodynamic calibration, we used the Pt–Co thermometer to link T* to the temperature ratios measured by single-pressure refractive-index gas thermometry (SPRIGT) in a different laboratory. (Gao et al 2020 Metrologia 57 065006) Now, the T*-linked SPRIGT system can calibrate other thermometers on the thermodynamic temperature scale T in the range 5 K ⩽ T ⩽ T Ne without using the international temperature scale ITS-90. At most temperatures in this range, the uncertainties of the T*-linked SPRIGT system are smaller than those of the ITS-90 systems used by National Metrology Institutes to calibrate resistance thermometers.
- 9 July 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (4) , 045006
Open AccessAcoustic measurement of the triple point of neon T Ne and thermodynamic calibration of a transfer standard for accurate cryogenic thermometry
We used absolute primary acoustic gas thermometry (AGT) to calibrate a Pt–Co resistance thermometer on the thermodynamic temperature scale by measuring the speed of sound in helium at a temperature T* chosen to be near the temperature of the triple point of neon, T Ne. Prior to the present AGT, the Pt–Co thermometer was used with a neon triple-point cell as part of an interlaboratory comparison. Taken together, the results of the interlaboratory comparison and the present AGT redetermined the thermodynamic temperature T Ne = (24.555 15 ± 0.000 24) K. This new value of T Ne is consistent with other recent determinations obtained with various primary methods. After completing the AGT thermodynamic calibration, we used the Pt–Co thermometer to link T* to the temperature ratios measured by single-pressure refractive-index gas thermometry (SPRIGT) in a different laboratory. (Gao et al 2020 Metrologia 57 065006) Now, the T*-linked SPRIGT system can calibrate other thermometers on the thermodynamic temperature scale T in the range 5 K ⩽ T ⩽ T Ne without using the international temperature scale ITS-90. At most temperatures in this range, the uncertainties of the T*-linked SPRIGT system are smaller than those of the ITS-90 systems used by National Metrology Institutes to calibrate resistance thermometers.