Thomas Bücherl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Bücherl has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Christoph Lierse von Gostomski
Technische Universität München - ZTWB Radiochemie
3 shared publications- Stefan Söllradl
Siemens Healthineers
2 shared publications - Albert Zeller
RC Tritec AG/LumiNova AG, Speicherstrasse 60 a, CH-9053 Teufen, Switzerland
1 shared publication - Andreas Georg Schreyer
Institut für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Brandenburg an der Havel – Medizinische Hochschule Brandenburg Theodor Fontane, Brandenburg an der Havel, Deutschland
1 shared publication Anton Kastenmüller
Technische Universität München - ZTWB Radiochemie
1 shared publication- Bernhard Walfort
LumiNova AG Switzerland Speicherstrasse 60a CH-9053 Teufen Switzerland
1 shared publication
Latest Publications
- Open Access
- 6 November 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 338, 11001
EducTUM - An Interactive Platform for Education and Training in the non-destructive analysis of radioactive materials
The decommissioning of nuclear facilities poses major challenges for the declaration of the resulting waste. This will be further exacerbated by changes to existing regulations and the introduction of new ones, also with regard to existing (legacy) waste. As dismantling will continue for decades to come, this requires the long-term maintenance of the relevant specific specialist skills. The EducTUM project ( https:\\educTUM.de ) aims to provide basic and advanced training, preserve skills and impart general information in the fields of radioactive waste characterization and product control. The combination of online measurements with real measuring equipment and real radioactive samples using (commercial) programs sets it apart from a “normal” Wikipedia webpage. It is aimed at a wide range of people, from those with a general interest in the subject to users and technical experts. The way in which knowledge is imparted therefore depends on the level of knowledge of the individual groups of people.
- 6 November 2025
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 338, 11001
Open AccessEducTUM - An Interactive Platform for Education and Training in the non-destructive analysis of radioactive materials
The decommissioning of nuclear facilities poses major challenges for the declaration of the resulting waste. This will be further exacerbated by changes to existing regulations and the introduction of new ones, also with regard to existing (legacy) waste. As dismantling will continue for decades to come, this requires the long-term maintenance of the relevant specific specialist skills. The EducTUM project ( https:\\educTUM.de ) aims to provide basic and advanced training, preserve skills and impart general information in the fields of radioactive waste characterization and product control. The combination of online measurements with real measuring equipment and real radioactive samples using (commercial) programs sets it apart from a “normal” Wikipedia webpage. It is aimed at a wide range of people, from those with a general interest in the subject to users and technical experts. The way in which knowledge is imparted therefore depends on the level of knowledge of the individual groups of people.
- Open Access
- 1 September 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2605 (1) , 012027
Digital radial radiography on radioactive waste packages using fission neutrons
Various methods for the non-destructive characterization of radioactive waste packages are applied in routine operation for identification and quantification of their radioactive inventory. As accuracy and precision play are an important role in the final documentation, an approach based on Bayesian statistics is presented for the evaluation of transmission data measured by digital radial radiography. The results of these data evaluations are probability density functions allowing to make predictions of the probability for a value a parameter can have. Furthermore a priori information can be easily considered in these evaluations. The applicability of the method is demonstrated by some elementary examples and shall act encouragingly for interested users for own investigations.
- 1 September 2023
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2605 (1) , 012027
Open AccessDigital radial radiography on radioactive waste packages using fission neutrons
Various methods for the non-destructive characterization of radioactive waste packages are applied in routine operation for identification and quantification of their radioactive inventory. As accuracy and precision play are an important role in the final documentation, an approach based on Bayesian statistics is presented for the evaluation of transmission data measured by digital radial radiography. The results of these data evaluations are probability density functions allowing to make predictions of the probability for a value a parameter can have. Furthermore a priori information can be easily considered in these evaluations. The applicability of the method is demonstrated by some elementary examples and shall act encouragingly for interested users for own investigations.
- Open Access
- 5 January 2020
- Published by Materials Research Forum, LLC in Materials Research Proceedings
- Vol. 15
Fission Neutron Tomography of a 280-L Waste Package
Based on a recent feasibility study, where it is demonstrated that fission neutron radiography of 200-l (radioactive) waste drums is possible at NECTAR, these investigations are extended to fission neutron tomography in transmission and emission mode. As sample, a 280-l drum is used containing inactive waste being typical for radioactive waste drums. For emission tomography, an AmBe-neutron source is measured separately and at different positions in the drum.
- 5 January 2020
- Published by Materials Research Forum, LLC in Materials Research Proceedings
- Vol. 15
Open AccessFission Neutron Tomography of a 280-L Waste Package
Based on a recent feasibility study, where it is demonstrated that fission neutron radiography of 200-l (radioactive) waste drums is possible at NECTAR, these investigations are extended to fission neutron tomography in transmission and emission mode. As sample, a 280-l drum is used containing inactive waste being typical for radioactive waste drums. For emission tomography, an AmBe-neutron source is measured separately and at different positions in the drum.
- 5 June 2019
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 322 (2) , 1195-1199
Uncertainty estimation in non-destructive characterization of radioactive waste packages: some general remarks
- 5 June 2019
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 322 (2) , 1195-1199
Uncertainty estimation in non-destructive characterization of radioactive waste packages: some general remarks
- Open Access
- 10 December 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 60
Performance of the Commercial PP/ZnS:Cu and PP/ZnS:Ag Scintillation Screens for Fast Neutron Imaging
Fast neutron imaging has a great potential as a nondestructive technique for testing large objects. The main factor limiting applications of this technique is detection technology, offering relatively poor spatial resolution of images and low detection efficiency, which results in very long exposure times. Therefore, research on development of scintillators for fast neutron imaging is of high importance. A comparison of the light output, gamma radiation sensitivity and spatial resolution of commercially available scintillator screens composed of PP/ZnS:Cu and PP/ZnS:Ag of different thicknesses are presented. The scintillators were provided by RC Tritec AG company and the test performed at the NECTAR facility located at the FRM II nuclear research reactor. It was shown that light output increases and the spatial resolution decreases with the scintillator thickness. Both compositions of the scintillating material provide similar light output, while the gamma sensitivity of PP/ZnS:Cu is significantly higher as compared to PP/ZnS:Ag-based scintillators. Moreover, we report which factors should be considered when choosing a scintillator and what are the limitations of the investigated types of scintillators.
- 10 December 2017
- Published by MDPI AG in Journal of Imaging
- Vol. 3 (4) , 60
Open AccessPerformance of the Commercial PP/ZnS:Cu and PP/ZnS:Ag Scintillation Screens for Fast Neutron Imaging
Fast neutron imaging has a great potential as a nondestructive technique for testing large objects. The main factor limiting applications of this technique is detection technology, offering relatively poor spatial resolution of images and low detection efficiency, which results in very long exposure times. Therefore, research on development of scintillators for fast neutron imaging is of high importance. A comparison of the light output, gamma radiation sensitivity and spatial resolution of commercially available scintillator screens composed of PP/ZnS:Cu and PP/ZnS:Ag of different thicknesses are presented. The scintillators were provided by RC Tritec AG company and the test performed at the NECTAR facility located at the FRM II nuclear research reactor. It was shown that light output increases and the spatial resolution decreases with the scintillator thickness. Both compositions of the scintillating material provide similar light output, while the gamma sensitivity of PP/ZnS:Cu is significantly higher as compared to PP/ZnS:Ag-based scintillators. Moreover, we report which factors should be considered when choosing a scintillator and what are the limitations of the investigated types of scintillators.
- 1 October 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 797, 158-164
Scattering influences in quantitative fission neutron radiography for the in situ analysis of hydrogen distribution in metal hydrides
- 1 October 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 797, 158-164
Scattering influences in quantitative fission neutron radiography for the in situ analysis of hydrogen distribution in metal hydrides
- Open Access
- 19 August 2015
- Published by Forschungszentrum Julich, Zentralbibliothek in Journal of large-scale research facilities JLSRF
- Vol. 1, A19
NECTAR: Radiography and tomography station using fission neutrons
NECTAR, operated by the Technische Universität München, is a versatile facility for the non-destructive inspection of various objects by means of fission neutron radiography and tomography, respectively.
- 19 August 2015
- Published by Forschungszentrum Julich, Zentralbibliothek in Journal of large-scale research facilities JLSRF
- Vol. 1, A19
Open AccessNECTAR: Radiography and tomography station using fission neutrons
NECTAR, operated by the Technische Universität München, is a versatile facility for the non-destructive inspection of various objects by means of fission neutron radiography and tomography, respectively.
- 1 September 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 651 (1) , 171-174
Filtering algorithm for dotted interferences
- 1 September 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 651 (1) , 171-174
Filtering algorithm for dotted interferences
- Open Access
- 4 January 2007
- Published by Sissa Medialab Srl
- p. 033
RADIOGRAPHY AND TOMOGRAPHY USING FISSION NEUTRONS
- 4 January 2007
- Published by Sissa Medialab Srl
- p. 033
Open AccessRADIOGRAPHY AND TOMOGRAPHY USING FISSION NEUTRONS