George Milushev
Research Subjects
George Milushev has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Christos A. Christodoulou
Department of Electrical and Computer Engineering, University of Thessaly, 382 21 Volos, Greece
2 shared publications - Vasiliki Vita
Department of Electrical and Electronic Engineering Educators, A.S.PE.T.E.—School of Pedagogical and Technological Education, 14121 Athens, Greece
2 shared publications - Dionisis Voglitsis
Department of Electrical and Computer Engineering, Democritus University of Thrace, Xanthi, Greece
1 shared publication - Georgios Perantzakis
Department of Electrical and Computer Engineering, University of Thessaly, 382 21 Volos, Greece
1 shared publication - Lambros Ekonomou
Hellenic American University
1 shared publication - Lambros Ekonomou
UBITECH Energy Sprl, 367 Avenue Louise, B-1050 Brussels, Belgium
1 shared publication
Latest Publications
- Open Access
- 12 February 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (2) , 273
A Heuristic Method for the Reduction of the Outage Rate of High-Voltage Substations Due to Atmospheric Overvoltages
The adequate protection against lightning surges and the limitation of the expected annual failure rate of high-voltage substations are critical issues, in an effort to secure the safety of the equipment and the personnel. Various factors affect the lightning performance of the substations, determining the developed lightning surges and the expected outage rate, i.e., the grounding resistance, the length of the underground cable between the connected overhead transmission line and the power transformer, and the installation position of the arresters. In the current work, a heuristic method is developed to adjust different parameters of high-voltage substations that upgrade their lightning performance. The proposed methodology can be useful to the studies of substations’ designers and engineers, contributing effectively in the reduction or/and elimination of lightning failures.
- 12 February 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (2) , 273
Open AccessA Heuristic Method for the Reduction of the Outage Rate of High-Voltage Substations Due to Atmospheric Overvoltages
The adequate protection against lightning surges and the limitation of the expected annual failure rate of high-voltage substations are critical issues, in an effort to secure the safety of the equipment and the personnel. Various factors affect the lightning performance of the substations, determining the developed lightning surges and the expected outage rate, i.e., the grounding resistance, the length of the underground cable between the connected overhead transmission line and the power transformer, and the installation position of the arresters. In the current work, a heuristic method is developed to adjust different parameters of high-voltage substations that upgrade their lightning performance. The proposed methodology can be useful to the studies of substations’ designers and engineers, contributing effectively in the reduction or/and elimination of lightning failures.
- Open Access
Adjusting the Parameters of Metal Oxide Gapless Surge Arresters’ Equivalent Circuits Using the Harmony Search Method
The appropriate circuit modeling of metal oxide gapless surge arresters is critical for insulation coordination studies. Metal oxide arresters present a dynamic behavior for fast front surges; namely, their residual voltage is dependent on the peak value, as well as the duration of the injected impulse current, and should therefore not only be represented by non-linear elements. The aim of the current work is to adjust the parameters of the most frequently used surge arresters’ circuit models by considering the magnitude of the residual voltage, as well as the dissipated energy for given pulses. In this aim, the harmony search method is implemented to adjust parameter values of the arrester equivalent circuit models. This functions by minimizing a defined objective function that compares the simulation outcomes with the manufacturer’s data and the results obtained from previous methodologies.
Open AccessAdjusting the Parameters of Metal Oxide Gapless Surge Arresters’ Equivalent Circuits Using the Harmony Search Method
The appropriate circuit modeling of metal oxide gapless surge arresters is critical for insulation coordination studies. Metal oxide arresters present a dynamic behavior for fast front surges; namely, their residual voltage is dependent on the peak value, as well as the duration of the injected impulse current, and should therefore not only be represented by non-linear elements. The aim of the current work is to adjust the parameters of the most frequently used surge arresters’ circuit models by considering the magnitude of the residual voltage, as well as the dissipated energy for given pulses. In this aim, the harmony search method is implemented to adjust parameter values of the arrester equivalent circuit models. This functions by minimizing a defined objective function that compares the simulation outcomes with the manufacturer’s data and the results obtained from previous methodologies.