Lise Nørkjær Bjerg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lise Nørkjær Bjerg has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Birgitte Sandfeld-Paulsen
Department of Clinical Biochemistry, Viborg Regional Hospital, 8800 Viborg, Denmark
4 shared publications - Henrik Holm Thomsen
Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
4 shared publications - Lukas Ochsner Reynaud Ridder
Department of Molecular Medicine, Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Mads Svart
Department of internal medicine, Regional Hospital Horsens, Horsens, Denmark; Steno Diabetes Center Aarhus, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
2 shared publications - Nikolaj Rittig
Steno Diabetes Center Aarhus, Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Simon K. Kjær
Steno Diabetes Center Aarhus, Aarhus University Hospital, Aarhus, Denmark
2 shared publications
Latest Publications
- Open Access
- 3 August 2026
- Published by Wiley in Physiological Reports
- Vol. 14 (15) , e71041
Intermittent exogenous ketosis increases erythropoietin in healthy adults: A randomized, placebo‐controlled study with preliminary sex‐specific observations
Exogenous ketosis may stimulate erythropoietin (EPO), yet its impact on erythropoiesis, iron metabolism, and potential sex‐specific responses in humans remains unknown. We investigated these effects in healthy adults using oral β‐hydroxybutyrate ketone monoester (KE) to induce intermittent ketosis. Acute EPO responses to a single dose of KE were assessed in 16 healthy adults (pre‐post), followed by a 2‐week randomized study (KE twice daily vs. placebo). After 2 weeks, EPO levels with intermittent ketosis were approximately 30% higher (95% CI 6, 60), p = 0.01, an effect more evident in females (9.7 IU/L (95% CI 6.0, 13.5) vs. 6.4 IU/L (95% CI 4.0, 8.8), p = 0.008) than in males (10.7 IU/L (7.2, 14.2) vs. 9.6 IU/L (6.3, 12.9), p = 0.46). Ferritin was elevated in females with KE vs. placebo (42 μg/L vs. 16 μg/L, p < 0.001). Hemoglobin and red blood cell count were unaffected at 2 weeks. Over 2 weeks, intermittent exogenous ketosis was associated with a modest increase in erythropoietin levels, with a stronger signal in females. Although hemoglobin and red blood cell count did not change significantly, females showed higher ferritin levels and a trend toward increased hematocrit, suggesting subtle effects on erythropoietic stimulation and iron handling.
- 3 August 2026
- Published by Wiley in Physiological Reports
- Vol. 14 (15) , e71041
Open AccessIntermittent exogenous ketosis increases erythropoietin in healthy adults: A randomized, placebo‐controlled study with preliminary sex‐specific observations
Exogenous ketosis may stimulate erythropoietin (EPO), yet its impact on erythropoiesis, iron metabolism, and potential sex‐specific responses in humans remains unknown. We investigated these effects in healthy adults using oral β‐hydroxybutyrate ketone monoester (KE) to induce intermittent ketosis. Acute EPO responses to a single dose of KE were assessed in 16 healthy adults (pre‐post), followed by a 2‐week randomized study (KE twice daily vs. placebo). After 2 weeks, EPO levels with intermittent ketosis were approximately 30% higher (95% CI 6, 60), p = 0.01, an effect more evident in females (9.7 IU/L (95% CI 6.0, 13.5) vs. 6.4 IU/L (95% CI 4.0, 8.8), p = 0.008) than in males (10.7 IU/L (7.2, 14.2) vs. 9.6 IU/L (6.3, 12.9), p = 0.46). Ferritin was elevated in females with KE vs. placebo (42 μg/L vs. 16 μg/L, p < 0.001). Hemoglobin and red blood cell count were unaffected at 2 weeks. Over 2 weeks, intermittent exogenous ketosis was associated with a modest increase in erythropoietin levels, with a stronger signal in females. Although hemoglobin and red blood cell count did not change significantly, females showed higher ferritin levels and a trend toward increased hematocrit, suggesting subtle effects on erythropoietic stimulation and iron handling.
- Open Access
- 13 January 2026
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 11, e85548
Continuous Ketone Monitoring: Data From a Randomized Controlled Trial
In our study, a commercially available continuous ketone monitoring device captured β-Hydroxybutyrate (BHB) dynamics during exogenous ketosis but revealed a gradual decline day-to-day BHB concentrations over 14 days in both ketone ester and placebo groups, likely reflecting sensor drift.
- 13 January 2026
- Published by JMIR Publications Inc. in JMIR Diabetes
- Vol. 11, e85548
Open AccessContinuous Ketone Monitoring: Data From a Randomized Controlled Trial
In our study, a commercially available continuous ketone monitoring device captured β-Hydroxybutyrate (BHB) dynamics during exogenous ketosis but revealed a gradual decline day-to-day BHB concentrations over 14 days in both ketone ester and placebo groups, likely reflecting sensor drift.
- Open Access
- 9 October 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Continuous ketone monitoring: Data from a randomized controlled trial (Preprint)
UNSTRUCTURED Abstract (summarizing sentence) In our study, the Sibio KS1 CKM device captured β-Hydroxybutyrate (BHB) dynamics during exogenous ketosis but revealed a gradual decline day-to-day BHB concentrations over 14 days in both KE and PBO groups, likely reflecting sensor drift.
- 9 October 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessContinuous ketone monitoring: Data from a randomized controlled trial (Preprint)
UNSTRUCTURED Abstract (summarizing sentence) In our study, the Sibio KS1 CKM device captured β-Hydroxybutyrate (BHB) dynamics during exogenous ketosis but revealed a gradual decline day-to-day BHB concentrations over 14 days in both KE and PBO groups, likely reflecting sensor drift.
- 2 January 2025
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 85 (1) , 58-63
Evaluating agreement between separate capillary sampling sites and venous concentrations of β-hydroxybutyrate measured by a point-of-care device and liquid chromatography tandem mass spectrometry
β-hydroxybutyrate (BHB) is recommended as a measure of ketosis and is often assessed by capillary samples on point-of-care (POC) meters. However, liquid chromatography tandem mass spectrometry (LC-MS/MS) is considered the gold standard for assessing venous samples. The POC device KetoSureTM is recommended only for capillary samples from finger pricks. So far, KetoSureTM has not been compared to LC-MS/MS just as it has not been evaluated if the sampling site influences the BHB concentration. Blood samples were collected from 16 healthy, fasting individuals before and after ingestion of ketone monoester. BHB concentrations were measured in capillary samples from the earlobe and fingertip, and in venous blood using KetoSureTM. Venous plasma samples were collected for BHB quantification using LC-MS/MS. No sign of significant difference between values of BHB measured from the two capillary sampling sites were found. Interestingly, significantly higher values of BHB were measured in capillary samples compared to venous samples reflecting a systematic proportional relationship. No systematic difference was observed in the measured BHB concentrations when comparing KetoSureTM and LC-MS/MS results: However, a significant mean bias of 32% reflects a skewness at very low BHB concentrations. In conclusion, capillary BHB concentration did not exhibit variation between the earlobe and fingertip. Conversely, a significant bias was observed between venous and capillary blood and between the POC and LC-MS/MS methods. It is recommended that caution be exercised if individual monitoring of BHB changes encompasses both capillary and venous sampling.
- 2 January 2025
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 85 (1) , 58-63
Evaluating agreement between separate capillary sampling sites and venous concentrations of β-hydroxybutyrate measured by a point-of-care device and liquid chromatography tandem mass spectrometry
β-hydroxybutyrate (BHB) is recommended as a measure of ketosis and is often assessed by capillary samples on point-of-care (POC) meters. However, liquid chromatography tandem mass spectrometry (LC-MS/MS) is considered the gold standard for assessing venous samples. The POC device KetoSureTM is recommended only for capillary samples from finger pricks. So far, KetoSureTM has not been compared to LC-MS/MS just as it has not been evaluated if the sampling site influences the BHB concentration. Blood samples were collected from 16 healthy, fasting individuals before and after ingestion of ketone monoester. BHB concentrations were measured in capillary samples from the earlobe and fingertip, and in venous blood using KetoSureTM. Venous plasma samples were collected for BHB quantification using LC-MS/MS. No sign of significant difference between values of BHB measured from the two capillary sampling sites were found. Interestingly, significantly higher values of BHB were measured in capillary samples compared to venous samples reflecting a systematic proportional relationship. No systematic difference was observed in the measured BHB concentrations when comparing KetoSureTM and LC-MS/MS results: However, a significant mean bias of 32% reflects a skewness at very low BHB concentrations. In conclusion, capillary BHB concentration did not exhibit variation between the earlobe and fingertip. Conversely, a significant bias was observed between venous and capillary blood and between the POC and LC-MS/MS methods. It is recommended that caution be exercised if individual monitoring of BHB changes encompasses both capillary and venous sampling.
- Open Access
- 1 June 2019
- Published by Elsevier in The Journal of Steroid Biochemistry and Molecular Biology
- Vol. 190, 224-233
An evaluation of total 25-hydroxyvitamin D assay standardization: Where are we today?
- 1 June 2019
- Published by Elsevier in The Journal of Steroid Biochemistry and Molecular Biology
- Vol. 190, 224-233
Open AccessAn evaluation of total 25-hydroxyvitamin D assay standardization: Where are we today?