Na An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Na An has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Bo Yang
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
6 shared publications - Hongchun Shu
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
5 shared publications - Tao Yu
School of Electric Power Engineering, South China University of Technology, Guangzhou 510641, China
4 shared publications - Fang Zeng
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Hongchun Shu
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Jian Chen
School of Electrical Engineering, Yancheng Institute of Technology, Yancheng, China
2 shared publications
Latest Publications
- Open Access
Single Pole-to-Ground Fault Analysis of MMC-HVDC Transmission Lines Based on Capacitive Fuzzy Identification Algorithm
The probability of a single pole-to-ground fault in high voltage direct current (HVDC) transmission lines is relatively high. For the modular multilevel converter HVDC (MMC-HVDC) systems, when a single pole-to-ground fault occurs, the fault current is small, and it is difficult to identify the fault quickly. Through a detailed analysis of the characteristics of the single pole-to-ground fault of the MMC-HVDC transmission line, it is found that the single pole-to-ground fault has obvious capacitance-related characteristics, and the transient process after the single pole-to-ground fault is the discharge process of the distributed capacitance of the line. However, other faults do not have such obvious capacitance-related characteristics. Based on such feature, this paper proposes a novel capacitive fuzzy identification method to identify the single pole-to-ground fault. This algorithm can effectively identify both the fault of single pole-to-ground and the fault pole, which can contribute to the large database of the future smart grid.
Open AccessSingle Pole-to-Ground Fault Analysis of MMC-HVDC Transmission Lines Based on Capacitive Fuzzy Identification Algorithm
The probability of a single pole-to-ground fault in high voltage direct current (HVDC) transmission lines is relatively high. For the modular multilevel converter HVDC (MMC-HVDC) systems, when a single pole-to-ground fault occurs, the fault current is small, and it is difficult to identify the fault quickly. Through a detailed analysis of the characteristics of the single pole-to-ground fault of the MMC-HVDC transmission line, it is found that the single pole-to-ground fault has obvious capacitance-related characteristics, and the transient process after the single pole-to-ground fault is the discharge process of the distributed capacitance of the line. However, other faults do not have such obvious capacitance-related characteristics. Based on such feature, this paper proposes a novel capacitive fuzzy identification method to identify the single pole-to-ground fault. This algorithm can effectively identify both the fault of single pole-to-ground and the fault pole, which can contribute to the large database of the future smart grid.
- Open Access
Overall Adaptive Controller Design of PMSG Under Whole Wind Speed Range: A Perturbation Compensation Based Approach
This paper proposes an adaptive overall control strategy of the permanent magnet synchronous generator-based wind energy conversion system (WECS) in the whole wind speed range. For the machine side, the maximum power point tracking (MPPT) operation is realized by stator current and mechanical rotation speed control under below-rated wind speeds. Under above-rated wind speeds, the extracted wind power is limited via pitch control. For the grid side, the reactive and active power injected into grid is regulated by DC-Link voltage and grid current control loop. In addition, under grid voltage dips, the pitch control is employed for limiting grid current and maintaining the DC-Link voltage around its rated value. The fault ride-through capability (FRTC) can be enhanced. The overall control strategy is based on perturbation estimation technique. A designed observer is used for estimating the perturbation term including all system nonlinearities, uncertainties and disturbances, so as to compensate the real perturbation. Then, an adaptive control for the original nonlinear system can be realized. The effectiveness of the proposed overall control strategy is verified by applying the strategy to a 2-MW WECS in MATLAB/Simulink. The results show that, compared with the feedback linearizing control (FLC) strategy and conventional vector control (VC) strategy, the proposed perturbation observer based adaptive control (PO-AC) strategy realizes the control objectives without knowing full state information and accurate system model, and improves the robustness of the WECS parameter uncertainties and FRTC.
Open AccessOverall Adaptive Controller Design of PMSG Under Whole Wind Speed Range: A Perturbation Compensation Based Approach
This paper proposes an adaptive overall control strategy of the permanent magnet synchronous generator-based wind energy conversion system (WECS) in the whole wind speed range. For the machine side, the maximum power point tracking (MPPT) operation is realized by stator current and mechanical rotation speed control under below-rated wind speeds. Under above-rated wind speeds, the extracted wind power is limited via pitch control. For the grid side, the reactive and active power injected into grid is regulated by DC-Link voltage and grid current control loop. In addition, under grid voltage dips, the pitch control is employed for limiting grid current and maintaining the DC-Link voltage around its rated value. The fault ride-through capability (FRTC) can be enhanced. The overall control strategy is based on perturbation estimation technique. A designed observer is used for estimating the perturbation term including all system nonlinearities, uncertainties and disturbances, so as to compensate the real perturbation. Then, an adaptive control for the original nonlinear system can be realized. The effectiveness of the proposed overall control strategy is verified by applying the strategy to a 2-MW WECS in MATLAB/Simulink. The results show that, compared with the feedback linearizing control (FLC) strategy and conventional vector control (VC) strategy, the proposed perturbation observer based adaptive control (PO-AC) strategy realizes the control objectives without knowing full state information and accurate system model, and improves the robustness of the WECS parameter uncertainties and FRTC.
- Open Access
- 1 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (19) , 4109
Adaptive Pitch Control of Variable-Pitch PMSG Based Wind Turbine
This paper presents an adaptive pitch-angle control approach for a permanent magnet-synchronous generator-based wind turbine (PMSG-WT) connecting with a power grid to limit extracted power above the rated wind speed. In the proposed control approach, a designed perturbation observer is employed for estimating and compensating unknown parameter uncertainties, system nonlinearities, and unknown disturbances. The proposed control approach does not require full state measurements or the accurate system model. Simulation tests verify the effectiveness of the proposed control approach. The simulation results demonstrate that compared with the feedback linearizing controller, conventional vector controller with proportional-integral (PI) loops, and PI controller with gain scheduling, the proposed control approach can always maintain the extracted wind power around rated power, and has higher performance and robustness against disturbance and parameter uncertainties.
- 1 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (19) , 4109
Open AccessAdaptive Pitch Control of Variable-Pitch PMSG Based Wind Turbine
This paper presents an adaptive pitch-angle control approach for a permanent magnet-synchronous generator-based wind turbine (PMSG-WT) connecting with a power grid to limit extracted power above the rated wind speed. In the proposed control approach, a designed perturbation observer is employed for estimating and compensating unknown parameter uncertainties, system nonlinearities, and unknown disturbances. The proposed control approach does not require full state measurements or the accurate system model. Simulation tests verify the effectiveness of the proposed control approach. The simulation results demonstrate that compared with the feedback linearizing controller, conventional vector controller with proportional-integral (PI) loops, and PI controller with gain scheduling, the proposed control approach can always maintain the extracted wind power around rated power, and has higher performance and robustness against disturbance and parameter uncertainties.
- Open Access
- 30 August 2019
- Published by MDPI AG in Electronics
- Vol. 8 (9) , 967
Passive Current Control Design for MMC in HVDC Systems through Energy Reshaping
The complexity of the internal dynamics of a modular multi-level converter (MMC) has raised severe issues for designing corresponding controllers. The existing MMC cascaded control strategies, based on classical linear control theory, require a relatively complex structure to achieve control objectives and the parameter tuning processes during the corresponding controller design are normally difficult to solve for the highly non-linear systems with highly coupled states in MMC. On account of this, advanced controllers are required for the regulation tasks of MMC. Passivity is introduced into the MMC control system by the passive control (PC) proposed in this paper. PC can provide an extra damping effect to help save energy through utilizing passivity in the system. A controllable de-coupled form is achieved by passivation of the output calculation. Hence, well-tuned controllers can be designed and employed to effectively regulate the output current and inner differential currents of the MMC under system operating point variation. Simulation results yield numerical data that show significantly improved steady-state and transient-state performances with greatly reduced control costs.
- 30 August 2019
- Published by MDPI AG in Electronics
- Vol. 8 (9) , 967
Open AccessPassive Current Control Design for MMC in HVDC Systems through Energy Reshaping
The complexity of the internal dynamics of a modular multi-level converter (MMC) has raised severe issues for designing corresponding controllers. The existing MMC cascaded control strategies, based on classical linear control theory, require a relatively complex structure to achieve control objectives and the parameter tuning processes during the corresponding controller design are normally difficult to solve for the highly non-linear systems with highly coupled states in MMC. On account of this, advanced controllers are required for the regulation tasks of MMC. Passivity is introduced into the MMC control system by the passive control (PC) proposed in this paper. PC can provide an extra damping effect to help save energy through utilizing passivity in the system. A controllable de-coupled form is achieved by passivation of the output calculation. Hence, well-tuned controllers can be designed and employed to effectively regulate the output current and inner differential currents of the MMC under system operating point variation. Simulation results yield numerical data that show significantly improved steady-state and transient-state performances with greatly reduced control costs.
- Open Access
Fault Ride-Through Capability Enhancement of Type-4 WECS in Offshore Wind Farm via Nonlinear Adaptive Control of VSC-HVDC
This paper proposes a perturbation estimation-based nonlinear adaptive control (NAC) for a voltage-source converter-based high voltage direct current (VSC-HVDC) system which is applied to interconnect offshore large-scale wind farms to the onshore main grid in order to enhance the fault ride-through (FRT) capability of Type-4 wind energy conversion systems (WECS). The VSC-HVDC power transmission system is regraded as a favourable solution for interconnecting offshore wind farms. To improve the FRT capability of offshore power plants, a de-loading strategy is investigated with novel advanced control of the VSC-HVDC systems. The proposed NAC does not require an accurate and precise model and full state measurements since the combinatorial effects of nonlinearities, system parameter uncertainties, and external disturbances are aggregated into a perturbation term, which are estimated by a high-gain perturbation observer (HGPO) and fully compensated for. As the proposed NAC is adaptive to system model uncertainties (e.g., mismatched output impedance of the converters and the line impedance of transmission line), time-varying disturbance (e.g., AC grid voltage sags and line to ground faults), and unknown time-varying nonlinearities of the power-electronic system (e.g., unmodelled dynamics existed in valve and VSC phase-locked loop system), a significant robustness can be provided by the de-loading strategy to enhance the FRT capability. Simulation results illustrated that the proposed strategy can provide improved dynamic performance in the case of operation with a variety of reduced voltage levels and improved robustness against model uncertainties and mismatched system parameters comparing with conventional vector control.
Open AccessFault Ride-Through Capability Enhancement of Type-4 WECS in Offshore Wind Farm via Nonlinear Adaptive Control of VSC-HVDC
This paper proposes a perturbation estimation-based nonlinear adaptive control (NAC) for a voltage-source converter-based high voltage direct current (VSC-HVDC) system which is applied to interconnect offshore large-scale wind farms to the onshore main grid in order to enhance the fault ride-through (FRT) capability of Type-4 wind energy conversion systems (WECS). The VSC-HVDC power transmission system is regraded as a favourable solution for interconnecting offshore wind farms. To improve the FRT capability of offshore power plants, a de-loading strategy is investigated with novel advanced control of the VSC-HVDC systems. The proposed NAC does not require an accurate and precise model and full state measurements since the combinatorial effects of nonlinearities, system parameter uncertainties, and external disturbances are aggregated into a perturbation term, which are estimated by a high-gain perturbation observer (HGPO) and fully compensated for. As the proposed NAC is adaptive to system model uncertainties (e.g., mismatched output impedance of the converters and the line impedance of transmission line), time-varying disturbance (e.g., AC grid voltage sags and line to ground faults), and unknown time-varying nonlinearities of the power-electronic system (e.g., unmodelled dynamics existed in valve and VSC phase-locked loop system), a significant robustness can be provided by the de-loading strategy to enhance the FRT capability. Simulation results illustrated that the proposed strategy can provide improved dynamic performance in the case of operation with a variety of reduced voltage levels and improved robustness against model uncertainties and mismatched system parameters comparing with conventional vector control.
- Open Access
Voltage Distribution–Based Fault Location for Half-Wavelength Transmission Line with Large-Scale Wind Power Integration in China
Large-scale wind farms are generally far away from load centers, hence there is an urgent need for a large-capacity power transmission scheme for extremely long distances, such as half-wavelength transmission lines (HWTLs), which can usually span thousands of kilometers from large-scale wind farms to load centers. An accurate fault location method for HWTLs is needed to ensure safe and reliable operation. This paper presents the design of a modal voltage distribution–based asynchronous double-end fault location (MVD-ADFL) scheme, in which the phase voltages and currents are transformed to modal components through a Karenbauer transformation matrix. Then, the modal voltage distributions along transmission lines are calculated by voltage and current from double ends. Moreover, the minimums and intersection points of calculated modal voltages from double ends are defined as the fault location estimation. In order to identify incorrect fault location results and reduce calculation errors for the correct ones, air modal and earth modal voltage distributions are applied in the fault location estimations. Simulation results verify the effectiveness of the proposed approach under different fault resistances, distances, and types. Lastly, a real-time digital simulator (RTDS)–based hardware-in-the-loop (HIL) test is undertaken to validate the feasibility of implementing the proposed approach.
Open AccessVoltage Distribution–Based Fault Location for Half-Wavelength Transmission Line with Large-Scale Wind Power Integration in China
Large-scale wind farms are generally far away from load centers, hence there is an urgent need for a large-capacity power transmission scheme for extremely long distances, such as half-wavelength transmission lines (HWTLs), which can usually span thousands of kilometers from large-scale wind farms to load centers. An accurate fault location method for HWTLs is needed to ensure safe and reliable operation. This paper presents the design of a modal voltage distribution–based asynchronous double-end fault location (MVD-ADFL) scheme, in which the phase voltages and currents are transformed to modal components through a Karenbauer transformation matrix. Then, the modal voltage distributions along transmission lines are calculated by voltage and current from double ends. Moreover, the minimums and intersection points of calculated modal voltages from double ends are defined as the fault location estimation. In order to identify incorrect fault location results and reduce calculation errors for the correct ones, air modal and earth modal voltage distributions are applied in the fault location estimations. Simulation results verify the effectiveness of the proposed approach under different fault resistances, distances, and types. Lastly, a real-time digital simulator (RTDS)–based hardware-in-the-loop (HIL) test is undertaken to validate the feasibility of implementing the proposed approach.