Hongchun Shu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongchun Shu has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Bo Yang
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
5 shared publications - Pulin Cao
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
4 shared publications - Chen Yong
School of Electric Engineering, Kunming University of Science and Technology, Kunming, Yunnan, China- 650051
2 shared publications - Jun Dong
Harbin Institute of Technology, Harbin 150001, China
2 shared publications - Liu Kezhen
Department of Electric Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China- 150001
2 shared publications - Na An
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications
Latest Publications
- Open Access
A Comprehensive Review of Power System Frequency Regulation Supported by Wind and Energy Storage Systems: State-of-the-Art Methods
With the increasing penetration of wind power in modern low-inertia power systems, frequency regulation (FR) faces significant challenges, primarily due to rapid frequency dynamics and stochastic power fluctuations. Energy storage systems (ESSs) can provide fast-responding bidirectional power support as well as virtual inertia, playing a critical role in enhancing system frequency stability. However, existing reviews provide limited systematic analysis linking model fidelity and operating constraints to the reported performance and applicability of wind–storage FR strategies. To address this gap, this paper reviews state-of-the-art FR strategies involving wind power and energy storage systems and provides a comprehensive analysis of key approaches, including optimization-based methods such as model predictive control (MPC) for multi-area systems and distributed MPC, as well as data-driven and intelligent techniques, such as deep reinforcement learning and soft-computing-based controllers. The comparison connects modeling assumptions and operating constraints with frequency response and energy-related evaluation metrics to clarify the benefits, limitations, and applicable conditions of different strategies. Finally, future research directions are proposed. This review offers a systematic reference for the analysis, design, selection, and evaluation of wind power and energy storage FR strategies in modern power systems.
Open AccessA Comprehensive Review of Power System Frequency Regulation Supported by Wind and Energy Storage Systems: State-of-the-Art Methods
With the increasing penetration of wind power in modern low-inertia power systems, frequency regulation (FR) faces significant challenges, primarily due to rapid frequency dynamics and stochastic power fluctuations. Energy storage systems (ESSs) can provide fast-responding bidirectional power support as well as virtual inertia, playing a critical role in enhancing system frequency stability. However, existing reviews provide limited systematic analysis linking model fidelity and operating constraints to the reported performance and applicability of wind–storage FR strategies. To address this gap, this paper reviews state-of-the-art FR strategies involving wind power and energy storage systems and provides a comprehensive analysis of key approaches, including optimization-based methods such as model predictive control (MPC) for multi-area systems and distributed MPC, as well as data-driven and intelligent techniques, such as deep reinforcement learning and soft-computing-based controllers. The comparison connects modeling assumptions and operating constraints with frequency response and energy-related evaluation metrics to clarify the benefits, limitations, and applicable conditions of different strategies. Finally, future research directions are proposed. This review offers a systematic reference for the analysis, design, selection, and evaluation of wind power and energy storage FR strategies in modern power systems.
- Open Access
Fault Phase Selection of Large-Scale Wind Farm’s Outgoing Line Based on Transient Voltage S-Transform Energy Relative Entropy
Traditional fault phase selection methods are not easily adaptable to large-scale wind farms. This paper proposes a fault phase selection method based on transient voltage S-transform energy relative entropy (SERE) to realize adaptive reclosing of the circuit breaker on the wind farm outgoing line. According to the characteristics of the three-phase transient voltage fault component, the three-phase transient voltage after a fault is collected, and the fault component is calculated. The SERE of the three-phase voltage is calculated. The maximum and minimum entropy are determined, and the criterion is constructed to identify the fault phase. The simulation results show that the proposed method can identify the fault phase accurately and quickly. The method is less affected by fault location, fault type, initial fault phase angle, and wind speed. In particular, the method can also accurately identify the fault phase under a remote high-resistance fault. The results compared with those of the traditional methods show that the proposed method demonstrates its superiority under different transitions and wind speeds.
Open AccessFault Phase Selection of Large-Scale Wind Farm’s Outgoing Line Based on Transient Voltage S-Transform Energy Relative Entropy
Traditional fault phase selection methods are not easily adaptable to large-scale wind farms. This paper proposes a fault phase selection method based on transient voltage S-transform energy relative entropy (SERE) to realize adaptive reclosing of the circuit breaker on the wind farm outgoing line. According to the characteristics of the three-phase transient voltage fault component, the three-phase transient voltage after a fault is collected, and the fault component is calculated. The SERE of the three-phase voltage is calculated. The maximum and minimum entropy are determined, and the criterion is constructed to identify the fault phase. The simulation results show that the proposed method can identify the fault phase accurately and quickly. The method is less affected by fault location, fault type, initial fault phase angle, and wind speed. In particular, the method can also accurately identify the fault phase under a remote high-resistance fault. The results compared with those of the traditional methods show that the proposed method demonstrates its superiority under different transitions and wind speeds.
- Open Access
- 10 July 2025
- Published by MDPI AG in Electricity
- Vol. 6  (3) , 42
Fault Location on Three-Terminal Transmission Lines Without Utilizing Line Parameters
Transmission lines are constantly exposed to changes in climatic conditions and aging which affect the parameters and change the characteristics of the three-terminal circuit over time. In this paper we propose a fault location algorithm for three-terminal transmission lines to solve this problem. The algorithm utilizes the positive components of the voltage and current signals measured synchronously from the terminals. In this work no prior knowledge of the line parameters was required when calculating the fault location and the use of fault classification algorithms was not necessary. In addition, the proposed method determines the parameters of the line segment and fault location based on a solid mathematical basis and has been verified through simulation results using SIMULINK/MATLAB R2018a software. The fault location results demonstrate the high accuracy and efficiency of the algorithm. Moreover, this method can estimate the characteristic impedance and propagation constants of the transmission lines and determine the location of the fault, which is not affected by different fault parameters including fault location, and fault resistance.
- 10 July 2025
- Published by MDPI AG in Electricity
- Vol. 6  (3) , 42
Open AccessFault Location on Three-Terminal Transmission Lines Without Utilizing Line Parameters
Transmission lines are constantly exposed to changes in climatic conditions and aging which affect the parameters and change the characteristics of the three-terminal circuit over time. In this paper we propose a fault location algorithm for three-terminal transmission lines to solve this problem. The algorithm utilizes the positive components of the voltage and current signals measured synchronously from the terminals. In this work no prior knowledge of the line parameters was required when calculating the fault location and the use of fault classification algorithms was not necessary. In addition, the proposed method determines the parameters of the line segment and fault location based on a solid mathematical basis and has been verified through simulation results using SIMULINK/MATLAB R2018a software. The fault location results demonstrate the high accuracy and efficiency of the algorithm. Moreover, this method can estimate the characteristic impedance and propagation constants of the transmission lines and determine the location of the fault, which is not affected by different fault parameters including fault location, and fault resistance.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 10  (1) , 90-102
Consistency Testing of Lead-Carbon Energy Storage Batteries Based on Random Matrix Theory and SOD
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 10  (1) , 90-102
Consistency Testing of Lead-Carbon Energy Storage Batteries Based on Random Matrix Theory and SOD
- Open Access
- 12 January 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 156
A fault location scheme based on composite traveling wave with transients in adjacent fault-free lines
- 12 January 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 156
Open AccessA fault location scheme based on composite traveling wave with transients in adjacent fault-free lines
- Open Access
Field Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.
Open AccessField Test Method and Equivalence Analysis of Delay Characteristics of DC Electronic Current Transformer
DC electronic current transformer is the data source of the system control and protection device, so its measurement delay has always been concerned. In this paper, the DC current transformer is modelled equivalently and the key factors affecting the delay of shunt and the remote module are analyzed. A field test method for the delay characteristics of the DC electronic current transformer is proposed. Moreover, a complex multi-state large current generator and integrated test system are developed. On the basis of the IEC 60044-8 standard transmission protocol, the accuracy of standard signal acquisition with the shunt is better than 0.2%. The maximum output current of the established testing system is 600 A. Based on the field test in an actual HVDC project, transient step and various frequency signal components are applied for analyzing.
- Open Access
- 15 June 2023
- Published by MDPI AG in Electronics
- Vol. 12  (12) , 2690
Model Predictive PI Circulating Current Control for Modular Multilevel Converter
Significant circulating currents in the modular multilevel converter (MMC) increase system losses and complicate heat-sink design. Conventional PI and PR controllers can achieve steady-state error adjustment, but are sensitive to parameter changes and model uncertainty, heavily relying on coordinate transformations and careful design of model parameters. Model predictive control (MPC) has the characteristics of simple design, good robustness, and excellent dynamic response; however, it encountered the complexity of adjusting weighting factors. This paper proposed circulating the current model predictive proportional integral control (MPPIC) method in abc reference frame. This hybrid control solution utilized the predictive model and traditional PI algorithm to combine the advantages of nonlinear and linear control. Compared with existing suppression methods, this method avoided complex mathematical operations and a selection of weight coefficients, was easy to implement, and can effectively suppress circulating currents under different modulation ratios. Simulations were conducted on MATLAB/Simulink to verify the effectiveness of the proposed control strategy. MPPIC can not only distinctly suppress the circulating currents, but also reduce the overall voltage fluctuation of sub-modules capacitors under different modulation ratios, and had almost no any adverse effect on the performance of MMC.
- 15 June 2023
- Published by MDPI AG in Electronics
- Vol. 12  (12) , 2690
Open AccessModel Predictive PI Circulating Current Control for Modular Multilevel Converter
Significant circulating currents in the modular multilevel converter (MMC) increase system losses and complicate heat-sink design. Conventional PI and PR controllers can achieve steady-state error adjustment, but are sensitive to parameter changes and model uncertainty, heavily relying on coordinate transformations and careful design of model parameters. Model predictive control (MPC) has the characteristics of simple design, good robustness, and excellent dynamic response; however, it encountered the complexity of adjusting weighting factors. This paper proposed circulating the current model predictive proportional integral control (MPPIC) method in abc reference frame. This hybrid control solution utilized the predictive model and traditional PI algorithm to combine the advantages of nonlinear and linear control. Compared with existing suppression methods, this method avoided complex mathematical operations and a selection of weight coefficients, was easy to implement, and can effectively suppress circulating currents under different modulation ratios. Simulations were conducted on MATLAB/Simulink to verify the effectiveness of the proposed control strategy. MPPIC can not only distinctly suppress the circulating currents, but also reduce the overall voltage fluctuation of sub-modules capacitors under different modulation ratios, and had almost no any adverse effect on the performance of MMC.
- Open Access
- 22 February 2023
- Published by MDPI AG in Electronics
- Vol. 12  (5) , 1080
Fault-Tolerant Control Strategy for Sub-Modules Open-Circuit Fault of Modular Multilevel Converter
Modular multilevel converter (MMC) is a key device of high-voltage-direct circuit (HVDC) transmission system, the sub-module detection technology of which will directly influence the damage severity, and even the reliability of the whole system. In this paper, the open-circuit fault characteristics of an insulated gate bipolar transistor (IGBT) in a sub-module are analyzed, and a fault-tolerant optimal control strategy is proposed for the redundant hot-reserved MMC based on nearest-level modulation (NLM). A fault sub-module diagnosis and location strategy based on the deviation distance of the capacitor voltages is presented. After the faulty sub-module is removed, due to the asymmetric operation of the MMC, odd-order circulating currents are introduced in the faulty phase, in which the fundamental-frequency circulating current is the major component; the fundamental-frequency voltage related to the redundancy rate is injected into the faulty phase, which effectively suppresses the fundamental-frequency circulating current and harmonics in the faulty phase. The proposed method combines fault detection and fault ride-through steps, so it has the features of high reliability and high compatibility. Based on the Matlab/Simulink simulation model, the effectiveness of the proposed strategy is verified.
- 22 February 2023
- Published by MDPI AG in Electronics
- Vol. 12  (5) , 1080
Open AccessFault-Tolerant Control Strategy for Sub-Modules Open-Circuit Fault of Modular Multilevel Converter
Modular multilevel converter (MMC) is a key device of high-voltage-direct circuit (HVDC) transmission system, the sub-module detection technology of which will directly influence the damage severity, and even the reliability of the whole system. In this paper, the open-circuit fault characteristics of an insulated gate bipolar transistor (IGBT) in a sub-module are analyzed, and a fault-tolerant optimal control strategy is proposed for the redundant hot-reserved MMC based on nearest-level modulation (NLM). A fault sub-module diagnosis and location strategy based on the deviation distance of the capacitor voltages is presented. After the faulty sub-module is removed, due to the asymmetric operation of the MMC, odd-order circulating currents are introduced in the faulty phase, in which the fundamental-frequency circulating current is the major component; the fundamental-frequency voltage related to the redundancy rate is injected into the faulty phase, which effectively suppresses the fundamental-frequency circulating current and harmonics in the faulty phase. The proposed method combines fault detection and fault ride-through steps, so it has the features of high reliability and high compatibility. Based on the Matlab/Simulink simulation model, the effectiveness of the proposed strategy is verified.
- Open Access
Research and Application of Power Grid Maintenance Scheduling Strategy under the Interactive Mode of New Energy and Electrolytic Aluminum Load
Formulating a reasonable and feasible unit maintenance scheme is a promising way to eliminate potential risks and improve the reliability of power systems. However, the uncertainty and volatility of new energy outputs, such as wind power, increase the difficulty of scheme formulation. To overcome the complexity of uncertainty, a robust unit maintenance scheme considering the uncertainty of new energy output and electrolytic aluminum load is established in this paper. Considering the significant time-series characteristics of new energy, this paper first introduces the definition and mathematical model of information granulation (IG), through which the initial new energy output data can be transformed into fuzzy particles used for prediction and analysis. Moreover, a support-vector machine (SVM) regression prediction model is adopted, and a corresponding progressive search algorithm is designed to determine SVM parameters efficiently. Then, a robust unit maintenance model is established considering the upper and lower predicted error. In addition, electrolytic aluminum loads are allowed to participate in power system dispatch. Finally, the modified reliability test system–Grid Modernization Lab Consortium (RTS–GMLC test system) and an actual power grid in Southwest China are used to verify the accuracy and feasibility of the proposed method.
Open AccessResearch and Application of Power Grid Maintenance Scheduling Strategy under the Interactive Mode of New Energy and Electrolytic Aluminum Load
Formulating a reasonable and feasible unit maintenance scheme is a promising way to eliminate potential risks and improve the reliability of power systems. However, the uncertainty and volatility of new energy outputs, such as wind power, increase the difficulty of scheme formulation. To overcome the complexity of uncertainty, a robust unit maintenance scheme considering the uncertainty of new energy output and electrolytic aluminum load is established in this paper. Considering the significant time-series characteristics of new energy, this paper first introduces the definition and mathematical model of information granulation (IG), through which the initial new energy output data can be transformed into fuzzy particles used for prediction and analysis. Moreover, a support-vector machine (SVM) regression prediction model is adopted, and a corresponding progressive search algorithm is designed to determine SVM parameters efficiently. Then, a robust unit maintenance model is established considering the upper and lower predicted error. In addition, electrolytic aluminum loads are allowed to participate in power system dispatch. Finally, the modified reliability test system–Grid Modernization Lab Consortium (RTS–GMLC test system) and an actual power grid in Southwest China are used to verify the accuracy and feasibility of the proposed method.
- Open Access
Fault Model and Travelling Wave Matching Based Single Terminal Fault Location Algorithm for T-Connection Transmission Line: A Yunnan Power Grid Study
Due to the complex structure of the T-connection transmission lines, it is extremely difficult to identify the reflected travelling wave from the fault point and that from the connection point by the measurement from only one terminal. According to the characteristics of the structure of the T-connection transmission line, the reflection of the travelling wave within the line after the failure of different sections in T-connection transmission line are analyzed. Based on the lattice diagram of the travelling wave, the sequence of travelling waves detected at the measuring terminal varies with the fault distance and the faulty section. Moreover, the sequence of travelling waves detected in one terminal is unique at each faulty section. This article calculates the arrival time of travelling waves of fault points at different locations in different sections to form the collection of the travelling wave arrival time sequence. Then the sequence of travelling waves of the new added fault waveforms is extracted to compare with the sequences in the collection for the faulty section identification and fault location. This proposed method can accurately locate the fault with different fault types, fault resistances and system impedances by only single-terminal fault data. Both Power Systems Computer Aided Design/ Electromagnetic Transients including DC (PSCAD/EMTDC) and actual measurement data are implemented to verify the effectiveness of this method.
Open AccessFault Model and Travelling Wave Matching Based Single Terminal Fault Location Algorithm for T-Connection Transmission Line: A Yunnan Power Grid Study
Due to the complex structure of the T-connection transmission lines, it is extremely difficult to identify the reflected travelling wave from the fault point and that from the connection point by the measurement from only one terminal. According to the characteristics of the structure of the T-connection transmission line, the reflection of the travelling wave within the line after the failure of different sections in T-connection transmission line are analyzed. Based on the lattice diagram of the travelling wave, the sequence of travelling waves detected at the measuring terminal varies with the fault distance and the faulty section. Moreover, the sequence of travelling waves detected in one terminal is unique at each faulty section. This article calculates the arrival time of travelling waves of fault points at different locations in different sections to form the collection of the travelling wave arrival time sequence. Then the sequence of travelling waves of the new added fault waveforms is extracted to compare with the sequences in the collection for the faulty section identification and fault location. This proposed method can accurately locate the fault with different fault types, fault resistances and system impedances by only single-terminal fault data. Both Power Systems Computer Aided Design/ Electromagnetic Transients including DC (PSCAD/EMTDC) and actual measurement data are implemented to verify the effectiveness of this method.