JTJoshua R. Tacca

Joshua R. Tacca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joshua R. Tacca has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Using EMG Biofeedback to Restore Closed-Loop Neural Control on a Powered Prosthetic Ankle

    by Brendan Driscoll, Joshua R. Tacca, Kasey Preisser, Ming Liu, Jonathan Stallrich, He Huang

    This paper aims to present that biofeedback based on electromyography (EMG) can help transtibial amputees to improve their capability to manipulate powered prosthetic ankles using Direct Electromyography (dEMG) control. First, we constructed a novel haptic based EMG biofeedback system composed of a HD haptic vest and an encoder that mapped EMG magnitude of residual shank muscles to tactile vibration patterns. Then we recruited six transtibial amputees and six no-disabled participants to conduct a position matching task, in which they conducted dEMG control on a powered prosthetic ankle with/without the biofeedback system after a brief acclimation. Impact of the EMG biofeedback system was evaluated based on their accuracy in matching specific targets in the position matching task. Our results demonstrated that 1) the EMG biofeedback can improve participants’ target matching accuracy; 2) the biofeedback led to more separable EMG signals among amputee participants when they tried to reach different targets; 3) for amputees, the improvement is more clearly observed when matching towards dorsiflexion targets; and 4) high performance variation among amputees is observed. Our work also demonstrated the feasibility of providing effective proprioceptive feedback based on muscle contraction level without involving any surgical procedure on lower limb amputees.

  • Open Access

    Effects of prosthetic ankle power and foot stiffness category on biomechanical asymmetry and knee moment during walking at different speeds

    by Joshua R. Tacca, Zane A. Colvin, Alena M. Grabowski

    People with unilateral transtibial amputation (uTTA) using a passive-elastic prosthesis typically walk with contact time (tc) and first and second peak vertical ground reaction force (F1 and F2) asymmetry and greater first peak external knee adduction moment in their unaffected versus affected leg. A previous study found that use of stance-phase powered prosthesis (BiOM) at a recommended power setting compared to a passive-elastic prosthesis can reduce tc asymmetry at self-selected speed and unaffected leg first peak external knee adduction moment at 1.50–1.75 m/s. However, the BiOM includes a passive-elastic prosthesis that can have different stiffness categories and can be tuned to different power settings, which may affect tc and F1 and F2 asymmetry and unaffected leg first peak external knee adduction moment. Thirteen people with uTTA used 16 different passive-elastic prosthetic foot stiffness categories and BiOM power settings to walk at 0.75–1.75 m/s. We found that use of the stiffest compared to least stiff category reduced F2 asymmetry. Use of the BiOM reduced tc asymmetry compared to a passive-elastic prosthesis and the effects of power setting on F1 and F2 asymmetry depended on walking speed. To minimize biomechanical asymmetry during walking at 1.25 m/s, people with uTTA should use the BiOM with power settings up to 20% greater than those that match biological ankle joint biomechanics. Such prosthetic settings could potentially reduce unaffected leg joint pain and/or osteoarthritis risk.


  • Open Access

    Greater than recommended stiffness and power setting of a stance-phase powered leg prosthesis can improve step-to-step transition work and effective foot length ratio during walking in people with transtibial amputation

    by Joshua R. Tacca, Zane A. Colvin, Alena M. Grabowski

    People with unilateral transtibial amputation (TTA) using a passive-elastic prosthesis exhibit lower positive affected leg trailing work (ALtrail Wpos) and a greater magnitude of negative unaffected leg leading work (ULlead Wneg) during walking than non-amputees, which may increase joint pain and osteoarthritis risk in the unaffected leg. People with TTA using a stance-phase powered prosthesis (e.g., BiOM, Ottobock, Duderstadt, Germany) walk with increased ALtrail Wpos and potentially decreased magnitude of ULlead Wneg compared to a passive-elastic prosthesis. The BiOM includes a passive-elastic prosthesis with a manufacturer-recommended stiffness category and can be tuned to different power settings, which may change ALtrail Wpos, ULlead Wneg, and the prosthesis effective foot length ratio (EFLR). Thirteen people with TTA walked using 16 different prosthetic stiffness category and power settings on a level treadmill at 0.75–1.75 m/s. We constructed linear mixed effects models to determine the effects of stiffness category and power settings on ALtrail Wpos, ULlead Wneg, and EFLR and hypothesized that decreased stiffness and increased power would increase ALtrail Wpos, not change and decrease ULlead Wneg magnitude, and decrease and not change prosthesis EFLR, respectively. We found there was no significant effect of stiffness category on ALtrail Wpos but increased stiffness reduced ULlead Wneg magnitude, perhaps due to a 0.02 increase in prosthesis EFLR compared to the least stiff category. Furthermore, we found that use of the BiOM with 10% and 20% greater than recommended power increased ALtrail Wpos and decreased ULlead Wneg magnitude at 0.75–1.00 m/s. However, prosthetic power setting depended on walking speed so that use of the BiOM increased ULlead Wneg magnitude at 1.50–1.75 m/s compared to a passive-elastic prosthesis. Ultimately, our results suggest that at 0.75–1.00 m/s, prosthetists should utilize the BiOM attached to a passive-elastic prosthesis with an increased stiffness category and power settings up to 20% greater than recommended based on biological ankle values. This prosthetic configuration can allow people with unilateral transtibial amputation to increase ALtrail Wpos and minimize ULlead Wneg magnitude, which could reduce joint pain and osteoarthritis risk in the unaffected leg and potentially lower the metabolic cost of walking.


  • Open Access

    Low-profile prosthetic foot stiffness category and size, and shoes affect axial and torsional stiffness and hysteresis

    by Joshua R. Tacca, Zane A. Colvin, Alena M. Grabowski

    Introduction: Passive-elastic prosthetic feet are manufactured with numerical stiffness categories and prescribed based on the user's body mass and activity level, but mechanical properties, such as stiffness values and hysteresis are not typically reported. Since the mechanical properties of passive-elastic prosthetic feet and footwear can affect walking biomechanics of people with transtibial or transfemoral amputation, characterizing these properties can provide objective metrics for comparison and aid prosthetic foot prescription and designMethods: We characterized axial and torsional stiffness values, and hysteresis of 33 categories and sizes of a commercially available passive-elastic prosthetic foot model [Össur low-profile (LP) Vari-flex] with and without a shoe. We assumed a greater numerical stiffness category would result in greater axial and torsional stiffness values but would not affect hysteresis. We hypothesized that a greater prosthetic foot length would not affect axial stiffness values or hysteresis but would result in greater torsional stiffness values. We also hypothesized that including a shoe would result in decreased axial and torsional stiffness values and greater hysteresis.Results: Prosthetic stiffness was better described by curvilinear than linear equations such that stiffness values increased with greater loads. In general, a greater numerical stiffness category resulted in increased heel, midfoot, and forefoot axial stiffness values, increased plantarflexion and dorsiflexion torsional stiffness values, and decreased heel, midfoot, and forefoot hysteresis. Moreover, for a given category, a longer prosthetic foot size resulted in decreased heel, midfoot, and forefoot axial stiffness values, increased plantarflexion and dorsiflexion torsional stiffness values, and decreased heel and midfoot hysteresis. In addition, adding a shoe to the prosthetic foot resulted in decreased heel and midfoot axial stiffness values, decreased plantarflexion torsional stiffness values, and increased heel, midfoot, and forefoot hysteresis.Discussion: Our results suggest that manufacturers should adjust the design of each category to ensure the mechanical properties are consistent across different sizes and highlight the need for prosthetists and researchers to consider the effects of shoes in combination with prostheses. Our results can be used to objectively compare the LP Vari-flex prosthetic foot to other prosthetic feet to inform their prescription, design, and use for people with a transtibial or transfemoral amputation.


  • Open Access

    Characterizing the mechanical properties of low-profile prosthetic feet

    by Joshua R. Tacca, Zane A. Colvin, Alena M. Grabowski

    Passive-elastic prosthetic feet are manufactured with different numerical stiffness categories that are prescribed based on the body mass and activity level of the user, but the mechanical properties, such as the stiffness values and hysteresis are not typically reported by the manufacturer. Since the mechanical properties of passive-elastic prosthetic feet can affect the walking biomechanics of people with transtibial or transfemoral amputation, characterizing these properties would provide objective values for comparison and aid the prescription of prosthetic feet. Therefore, we characterized the axial stiffness values, torsional stiffness values, and hysteresis of 33 different categories and sizes of a commercially available passive-elastic prosthetic foot model, the Össur low-profile (LP) Vari-flex with and without a shoe. We measured axial stiffness from compression and torsional stiffness from dorsiflexing and plantarflexing the prostheses. In general, a greater numerical prosthetic foot stiffness category resulted in increased heel, midfoot, and forefoot axial stiffness values, increased plantarflexion and dorsiflexion torsional stiffness values, and decreased heel, midfoot, and forefoot hysteresis. Moreover, a greater prosthetic foot size resulted in decreased heel, midfoot, and forefoot axial stiffness values, increased plantarflexion and dorsiflexion torsional stiffness values, and decreased heel and midfoot hysteresis. Finally, adding a shoe to the LP Vari-flex prosthetic foot resulted in decreased heel and midfoot axial stiffness values, decreased plantarflexion torsional stiffness values, and increased heel, midfoot, and forefoot hysteresis. In addition, we found that the force-displacement and torque-angle relationships were better described by curvilinear than linear equations. Ultimately, our results can be used to objectively compare LP Vari-flex prosthetic feet to other prosthetic feet in order to inform their prescription and design and use by people with a transtibial or transfemoral amputation.

  • Open Access

    Running-specific prosthesis model, stiffness and height affect biomechanics and asymmetry of athletes with unilateral leg amputations across speeds

    by Joshua R. Tacca, Owen N. Beck, Paolo Taboga, Alena M. Grabowski

    Athletes with transtibial amputation (TTA) use running-specific prostheses (RSPs) to run. RSP configuration likely affects the biomechanics of such athletes across speeds. We determined how the use of three RSP models (Catapult, Sprinter and Xtend) with three stiffness categories (recommended, ±1), and three heights (recommended, ±2 cm) affected contact length ( L c ), stance average vertical ground reaction force ( F avg ), step frequency ( f step ) and asymmetry between legs for 10 athletes with unilateral TTA at 3–7 m s −1 . The use of the Xtend versus Catapult RSP decreased L c ( p = 2.69 × 10 −7 ) and F avg asymmetry ( p = 0.032); the effect on L c asymmetry diminished with faster speeds ( p = 0.0020). The use of the Sprinter versus Catapult RSP decreased F avg asymmetry ( p = 7.00 × 10 −5 ); this effect was independent of speed ( p = 0.90). The use of a stiffer RSP decreased L c asymmetry ( p ≤ 0.00033); this effect was independent of speed ( p ≥ 0.071). The use of a shorter RSP decreased L c ( p = 5.86 × 10 −6 ), F avg ( p = 8.58 × 10 −6 ) and f step asymmetry ( p = 0.0011); each effect was independent of speed ( p ≥ 0.15). To minimize asymmetry, athletes with unilateral TTA should use an Xtend or Sprinter RSP with 2 cm shorter than recommended height and stiffness based on intended speed.


  • Design of a Low Profile, Unpowered Ankle Exoskeleton That Fits Under Clothes: Overcoming Practical Barriers to Widespread Societal Adoption

    by Matthew B. Yandell, Joshua R. Tacca, Karl E. Zelik

    Here, we present the design of a novel unpowered ankle exoskeleton that is low profile, lightweight, quiet, and low cost to manufacture, intrinsically adapts to different walking speeds, and does not restrict non-sagittal joint motion; while still providing assistive ankle torque that can reduce demands on the biological calf musculature. This paper is an extension of the previously-successful ankle exoskeleton concept by Collins, Wiggin and Sawicki. We created a device that blends the torque assistance of the prior exoskeleton with the form-factor benefits of clothing. Our design integrates a low profile under-the-foot clutch and a soft conformal shank interface, coupled by an ankle assistance spring that operates in parallel with the user's calf muscles. We fabricated and characterized technical performance of a prototype through benchtop testing and then validated device functionality in two gait analysis case studies. To our knowledge, this is the first ankle plantarflexion assistance exoskeleton that could be feasibly worn under typical daily clothing, without restricting ankle motion, and without components protruding substantially from the shoe, leg, waist, or back. Our new design highlights the potential for performance-enhancing exoskeletons that are inexpensive, unobtrusive, and can be used on a wide scale to benefit a broad range of individuals throughout society, such as the elderly, individuals with impaired plantarflexor muscle strength, or recreational users. In summary, this paper demonstrates how an unpowered ankle exoskeleton could be redesigned to more seamlessly integrate into daily life, while still providing performance benefits for common locomotion tasks.