Hsien-Kuang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hsien-Kuang Liu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Shun-Fa Hwang
Department of Mechanical Engineering, National Yunlin University of Science and Technology, 123 University Road, Sec. 3, Yunlin 64002, Taiwan
3 shared publications Chao-Chang A. Chen
Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
2 shared publications- Shih-Hung Yang
Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan
2 shared publications - Wei-Chong Liao
Department of Civil Engineering, Feng Chia University, 100 Wenhwa Road, Taichung 40724, Taiwan
2 shared publications - Yi Kai Cheng
Graduate school of Natural Science and Technology, Okayama University, 3-1-1 Tsushimanaka, Kita-ku, Okayama 700-8530, Japan
2 shared publications Azar Parvizi‐Majidi
Center for Composite Materials and Department of Mechanical Engineering, University of Delaware, Newark, Delaware 19716
1 shared publication
Latest Publications
- Open Access
Fabrication and Characterization of Diaphragm Headphones Based on Graphene Nanocomposites
The goal of this paper is to fabricate innovative diaphragm headphones using graphene oxide paper (GOP) and GOP/epoxy nanocomposites (GOPC). Initially, graphene oxide suspension is fabricated, and the vacuum filtration method is adopted to make GOP. Then, vacuum bag molding is used to fabricate GOPC from GOP. Hot pressing and associated molds are adopted to fabricate line-indented (GOPC-L) or curve-indented patterns (GOPC-C) on the GOPC. The performances of one kind of GOP and three kinds of GOPC diaphragm headphones are analyzed based on their sound pressure level (SPL) curves achieved by the Soundcheck measurement system. There are four important processing parameters that will influence the performance of the diaphragm, including material type GOP versus GOPC, indented pattern type, sonication time on suspension, and graphene weight fraction in suspension. Compliances of various diaphragms are measured by the Klippel LPM laser measurement system. The results indicate that effects of sonication time and graphene weight fraction on SPL of GOP and GOPC headphones are in reverse, and this is associated with their difference on compliance (modulus), mass, damping ratio, and microstructure uniformity. Either GOPC-L or GOPC-C seems to improve the microstructure of the GOPC, and leads to better SPL performance. The correlation between the previous four factors and SPLs of four kinds of diaphragm headphones is proposed by using scanning electron microscope (SEM) to examine the microstructure of these diaphragms.
Open AccessFabrication and Characterization of Diaphragm Headphones Based on Graphene Nanocomposites
The goal of this paper is to fabricate innovative diaphragm headphones using graphene oxide paper (GOP) and GOP/epoxy nanocomposites (GOPC). Initially, graphene oxide suspension is fabricated, and the vacuum filtration method is adopted to make GOP. Then, vacuum bag molding is used to fabricate GOPC from GOP. Hot pressing and associated molds are adopted to fabricate line-indented (GOPC-L) or curve-indented patterns (GOPC-C) on the GOPC. The performances of one kind of GOP and three kinds of GOPC diaphragm headphones are analyzed based on their sound pressure level (SPL) curves achieved by the Soundcheck measurement system. There are four important processing parameters that will influence the performance of the diaphragm, including material type GOP versus GOPC, indented pattern type, sonication time on suspension, and graphene weight fraction in suspension. Compliances of various diaphragms are measured by the Klippel LPM laser measurement system. The results indicate that effects of sonication time and graphene weight fraction on SPL of GOP and GOPC headphones are in reverse, and this is associated with their difference on compliance (modulus), mass, damping ratio, and microstructure uniformity. Either GOPC-L or GOPC-C seems to improve the microstructure of the GOPC, and leads to better SPL performance. The correlation between the previous four factors and SPLs of four kinds of diaphragm headphones is proposed by using scanning electron microscope (SEM) to examine the microstructure of these diaphragms.
- Open Access
- 3 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 445
Thermoforming Simulation of Woven Carbon Fiber Fabric/Polyurethane Composite Materials
A finite element simulation was utilized in this work to analyze the thermoforming process of woven carbon fiber fabric/polyurethane thermoplastic composite sheets. In the simulation that may be classified as a discrete method, the woven carbon fiber fabric was treated as an undulated fill yarn crossed over an undulated warp yarn, and the resin was considered separately. Then, they were combined to represent the composite sheets. To verify this simulation, bias extension tests under three constant temperatures were executed. After that, the composite was thermoformed into a U-shaped structure and small luggage. From the bias extension tests, the finite element simulation and material properties of the fiber and resin were confirmed. From the comparison of the thermoformed products, the present simulation could provide the deformed profile and fiber-included angles and has good agreement with the experiment. The results also indicate that the stacking sequences of [(0°/90°)]4 and [(+45°/−45°)]4 have quite different product profiles and fiber-included angles.
- 3 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 445
Open AccessThermoforming Simulation of Woven Carbon Fiber Fabric/Polyurethane Composite Materials
A finite element simulation was utilized in this work to analyze the thermoforming process of woven carbon fiber fabric/polyurethane thermoplastic composite sheets. In the simulation that may be classified as a discrete method, the woven carbon fiber fabric was treated as an undulated fill yarn crossed over an undulated warp yarn, and the resin was considered separately. Then, they were combined to represent the composite sheets. To verify this simulation, bias extension tests under three constant temperatures were executed. After that, the composite was thermoformed into a U-shaped structure and small luggage. From the bias extension tests, the finite element simulation and material properties of the fiber and resin were confirmed. From the comparison of the thermoformed products, the present simulation could provide the deformed profile and fiber-included angles and has good agreement with the experiment. The results also indicate that the stacking sequences of [(0°/90°)]4 and [(+45°/−45°)]4 have quite different product profiles and fiber-included angles.
- Open Access
- 18 September 2023
- Published by MDPI AG in Preprints.org
Fabrication and Performance of Diaphragm Headphones Based on Graphene and Graphene Nanocomposites
The goal of this paper is to fabricate innovative diaphragm headphones using graphene oxide paper (GOP) and GOP/epoxy nanocomposites (GOPC). Initially, graphene oxide suspension is fabricated, and the vacuum filtration method is adopted to make GOP. Then vacuum bag molding is used to fabricate GOPC from GOP. Hot pressing and associated molds are adopted to fabricate line-indented (GOPC-L) or curve-indented patterns (GOPC-C) on the GOPC. The performance of one kind of GOP and three kinds of GOPC diaphragm headphones is analyzed based on their sound pressure level (SPL) curves achieved by the Soundcheck measurement system. There are four important processing parameters that will influence the performance of the diaphragm, including material type GOP versus GOPC, indented pattern type, sonication time on suspension, and graphene weight fraction in suspension. Compliances of various diaphragms are measured by the Klippel LPM laser measurement system. The results indicate that effects of sonication time and graphene weight fraction on SPL of GOP and GOPC headphones are in reverse, and this is associated with their difference on compliance (modulus), mass, damping ratio, and microstructure uniformity. Either GOPC-L or GOPC-C seems to improve the microstructure of the GOPC, and leads to better SPL performance. The correlation between the previous four factors and SPLs of four kinds of diaphragm headphones is proposed by using scanning electron microscope (SEM) to examine the microstructure of these diaphragms.
- 18 September 2023
- Published by MDPI AG in Preprints.org
Open AccessFabrication and Performance of Diaphragm Headphones Based on Graphene and Graphene Nanocomposites
The goal of this paper is to fabricate innovative diaphragm headphones using graphene oxide paper (GOP) and GOP/epoxy nanocomposites (GOPC). Initially, graphene oxide suspension is fabricated, and the vacuum filtration method is adopted to make GOP. Then vacuum bag molding is used to fabricate GOPC from GOP. Hot pressing and associated molds are adopted to fabricate line-indented (GOPC-L) or curve-indented patterns (GOPC-C) on the GOPC. The performance of one kind of GOP and three kinds of GOPC diaphragm headphones is analyzed based on their sound pressure level (SPL) curves achieved by the Soundcheck measurement system. There are four important processing parameters that will influence the performance of the diaphragm, including material type GOP versus GOPC, indented pattern type, sonication time on suspension, and graphene weight fraction in suspension. Compliances of various diaphragms are measured by the Klippel LPM laser measurement system. The results indicate that effects of sonication time and graphene weight fraction on SPL of GOP and GOPC headphones are in reverse, and this is associated with their difference on compliance (modulus), mass, damping ratio, and microstructure uniformity. Either GOPC-L or GOPC-C seems to improve the microstructure of the GOPC, and leads to better SPL performance. The correlation between the previous four factors and SPLs of four kinds of diaphragm headphones is proposed by using scanning electron microscope (SEM) to examine the microstructure of these diaphragms.
- 22 April 2022
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 120 (11-12) , 7157-7169
Chemically grafted polyurethane/graphene ternary slurry for advanced chemical–mechanical polishing of single-crystalline SiC wafers
- 22 April 2022
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 120 (11-12) , 7157-7169
Chemically grafted polyurethane/graphene ternary slurry for advanced chemical–mechanical polishing of single-crystalline SiC wafers
- 4 January 2022
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 51 (3) , 985-994
Radar-Absorbing Structures with Reduced Graphene Oxide Papers Fabricated Under Various Processing Parameters
- 4 January 2022
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 51 (3) , 985-994
Radar-Absorbing Structures with Reduced Graphene Oxide Papers Fabricated Under Various Processing Parameters
- Open Access
- 3 December 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (12) , 495
An Instrumented Glove-Controlled Portable Hand-Exoskeleton for Bilateral Hand Rehabilitation
Effective bilateral hand training is desired in rehabilitation programs to restore hand function for people with unilateral hemiplegia, so that they can perform daily activities independently. However, owing to limited human resources, the hand function training available in current clinical settings is significantly less than the adequate amount needed to drive optimal neural reorganization. In this study, we designed a lightweight and portable hand exoskeleton with a hand-sensing glove for bilateral hand training and home-based rehabilitation. The hand-sensing glove measures the hand movement of the less-affected hand using a flex sensor. Thereafter, the affected hand is driven by the hand exoskeleton using the measured hand movements. Compared with the existing hand exoskeletons, our hand exoskeleton improves the flexible mechanism for the back of the hand for better wearing experience and the thumb mechanism to make the pinch gesture possible. We designed a virtual reality game to increase the willingness of repeated movement practice for rehabilitation. Our system not only facilitates bilateral hand training but also assists in activities of daily living. This system could be beneficial for patients with hemiplegia for starting correct and sufficient hand function training in the early stages to optimize their recovery.
- 3 December 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (12) , 495
Open AccessAn Instrumented Glove-Controlled Portable Hand-Exoskeleton for Bilateral Hand Rehabilitation
Effective bilateral hand training is desired in rehabilitation programs to restore hand function for people with unilateral hemiplegia, so that they can perform daily activities independently. However, owing to limited human resources, the hand function training available in current clinical settings is significantly less than the adequate amount needed to drive optimal neural reorganization. In this study, we designed a lightweight and portable hand exoskeleton with a hand-sensing glove for bilateral hand training and home-based rehabilitation. The hand-sensing glove measures the hand movement of the less-affected hand using a flex sensor. Thereafter, the affected hand is driven by the hand exoskeleton using the measured hand movements. Compared with the existing hand exoskeletons, our hand exoskeleton improves the flexible mechanism for the back of the hand for better wearing experience and the thumb mechanism to make the pinch gesture possible. We designed a virtual reality game to increase the willingness of repeated movement practice for rehabilitation. Our system not only facilitates bilateral hand training but also assists in activities of daily living. This system could be beneficial for patients with hemiplegia for starting correct and sufficient hand function training in the early stages to optimize their recovery.
- 1 October 2020
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 43 (10) , 2287-2297
Fatigue analysis of graphene oxide papers fabricated under various processing parameters
- 1 October 2020
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 43 (10) , 2287-2297
Fatigue analysis of graphene oxide papers fabricated under various processing parameters
- 27 January 2020
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 106 (11-12) , 4755-4768
Effects of compound diamond slurry with graphene for lapping of sapphire wafers
- 27 January 2020
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 106 (11-12) , 4755-4768
Effects of compound diamond slurry with graphene for lapping of sapphire wafers
- 17 September 2019
- Published by World Scientific Pub Co Pte Ltd in Functional Materials Letters
- Vol. 12 (05)
Effect of graphene additions on polishing of silicon carbide wafer with functional PU/silica particles in CMP slurry
In this paper, a functional ternary slurry consisting of polyurethane (PU) microspheres, graphene oxide (GO) nano platelets and silicon oxide (SiO2) abrasives was used to carry out the polishing process on Si face of 4H-SiC wafers. The processing parameters of the slurry include graphene weight fraction in slurry GO1–GO7 (0.1–0.7[ ]wt.%), pH value (3–5), and sonication time T5–T15 (5–15[ ]min). Polishing process is conducted with two kinds of polishing pads A and B, PU and PC (polycarbonate). Results show that material removal rate (MRR) increases with increasing GO weight fraction up to GO5; besides, MRR also increases with increasing sonication time up to T10, and with increasing pH value. Using PU pad, the GO5-T10-pH5-A slurry leads to highest MRR 102.220[ ]nm/h of the polished SiC wafer. On the other hand, surface roughness improvement rate (SRIR) increases with increasing GO weight fraction up to GO5, and increases with increasing sonication time up to T15. But SRIR is not affected by pH value. Regarding effect of pad type, on average the PU pad results in higher MRR and better SRIR compared with the PC pad. Using PC pad, GO5-T10-pH5-B leads to lower MRR of 87.627[ ]nm/h. The addition of GO as the ternary slurry demonstrates its better effect on polishing SiC wafers by comparing with the counterpart binary slurry without GO. For example, MRR by the counterpart slurry SiO212-pH5-A is 58.411[ ]nm/h, which is lower than 102.220[ ]nm/h by the ternary slurry GO5-T10-pH5-A. Both XPS and Raman spectra demonstrate that the wafer polished by the functional ternary slurry can effectively produce the softer SiO2 reactant layer on SiC wafer, and result in better polishing performance.
- 17 September 2019
- Published by World Scientific Pub Co Pte Ltd in Functional Materials Letters
- Vol. 12 (05)
Effect of graphene additions on polishing of silicon carbide wafer with functional PU/silica particles in CMP slurry
In this paper, a functional ternary slurry consisting of polyurethane (PU) microspheres, graphene oxide (GO) nano platelets and silicon oxide (SiO2) abrasives was used to carry out the polishing process on Si face of 4H-SiC wafers. The processing parameters of the slurry include graphene weight fraction in slurry GO1–GO7 (0.1–0.7[ ]wt.%), pH value (3–5), and sonication time T5–T15 (5–15[ ]min). Polishing process is conducted with two kinds of polishing pads A and B, PU and PC (polycarbonate). Results show that material removal rate (MRR) increases with increasing GO weight fraction up to GO5; besides, MRR also increases with increasing sonication time up to T10, and with increasing pH value. Using PU pad, the GO5-T10-pH5-A slurry leads to highest MRR 102.220[ ]nm/h of the polished SiC wafer. On the other hand, surface roughness improvement rate (SRIR) increases with increasing GO weight fraction up to GO5, and increases with increasing sonication time up to T15. But SRIR is not affected by pH value. Regarding effect of pad type, on average the PU pad results in higher MRR and better SRIR compared with the PC pad. Using PC pad, GO5-T10-pH5-B leads to lower MRR of 87.627[ ]nm/h. The addition of GO as the ternary slurry demonstrates its better effect on polishing SiC wafers by comparing with the counterpart binary slurry without GO. For example, MRR by the counterpart slurry SiO212-pH5-A is 58.411[ ]nm/h, which is lower than 102.220[ ]nm/h by the ternary slurry GO5-T10-pH5-A. Both XPS and Raman spectra demonstrate that the wafer polished by the functional ternary slurry can effectively produce the softer SiO2 reactant layer on SiC wafer, and result in better polishing performance.
- Open Access
- 16 March 2016
- Published by Oxford University Press (OUP) in Journal of Mechanics
- Vol. 32 (6) , 673-682
Moisture Effect on Mechanical Properties of Graphene/Epoxy Nanocomposites
2-D graphene nanosheets (GNS) not only have superior mechanical properties, but stacking of GNS in composites is expected to inhibit moisture absorption. In this paper, moisture effect on tensile strength of graphene/epoxy nanocomposites is investigated. Two kinds of graphene reinforcements are used including graphene oxide (GO) and reduced graphene oxide (RGO) with reinforcement weight fraction WGO or WRGO in the range of 0.5 to 3.0wt%. A dispersion agent acetone is added in nanocomposites to enhance graphene dispersion. To evaluate moisture influence, those nanocomposites are soaked in two kinds of liquid including deionized water (DIW) and salt water (saline solution) for seven kinds of soaking periods of time including 24, 48, 72, 100, 400 hours, 30 days, and 60 days. After soaking test, diffusion coefficients of various composites are evaluated; besides tensile strengths of composites are measured by microforce testing machine. In order to correlate the strength with microstructure evolution, several techniques are adopted to analyze morphologies and functionalities of reinforcements and fracture surface of composites. They include Raman spectroscope, X-ray photoelectron spectroscope, and SEM. 2-D GNS are found to effectively enhance nanocomposites by moisture attack, and their corresponding reinforcing mechanisms are proposed.
- 16 March 2016
- Published by Oxford University Press (OUP) in Journal of Mechanics
- Vol. 32 (6) , 673-682
Open AccessMoisture Effect on Mechanical Properties of Graphene/Epoxy Nanocomposites
2-D graphene nanosheets (GNS) not only have superior mechanical properties, but stacking of GNS in composites is expected to inhibit moisture absorption. In this paper, moisture effect on tensile strength of graphene/epoxy nanocomposites is investigated. Two kinds of graphene reinforcements are used including graphene oxide (GO) and reduced graphene oxide (RGO) with reinforcement weight fraction WGO or WRGO in the range of 0.5 to 3.0wt%. A dispersion agent acetone is added in nanocomposites to enhance graphene dispersion. To evaluate moisture influence, those nanocomposites are soaked in two kinds of liquid including deionized water (DIW) and salt water (saline solution) for seven kinds of soaking periods of time including 24, 48, 72, 100, 400 hours, 30 days, and 60 days. After soaking test, diffusion coefficients of various composites are evaluated; besides tensile strengths of composites are measured by microforce testing machine. In order to correlate the strength with microstructure evolution, several techniques are adopted to analyze morphologies and functionalities of reinforcements and fracture surface of composites. They include Raman spectroscope, X-ray photoelectron spectroscope, and SEM. 2-D GNS are found to effectively enhance nanocomposites by moisture attack, and their corresponding reinforcing mechanisms are proposed.