Roghayeh Amini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roghayeh Amini has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Abolghasem Jouyban
Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran
3 shared publications - Karim Asadpour-Zeynali
Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
3 shared publications - Elaheh Rahimpour
Pharmaceutical Analysis Research Center, Pharmaceutical Sciences Institute, Tabriz University of Medical Sciences, Tabriz, Iran
2 shared publications - Hossein Abdolmohammad-Zadeh
Analytical Spectroscopy Research Lab, Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran
2 shared publications Abulghasem Jouyban
Drug Applied Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
1 shared publicationGolamhossein Sadeghi
Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran
1 shared publication
Latest Publications
- 6 August 2020
- Published by Taylor & Francis in Bioanalysis
- Vol. 12 (16) , 1161-1194
Determination of Morphine and Its Metabolites in the Biological Samples: An Updated Review
Morphine (MO) as an opioid analgesic is used for the treatment of moderate-to-severe pains, particularly cancer-related pains. Pharmacologic studies on MO are complicated due to drugs binding to th...
- 6 August 2020
- Published by Taylor & Francis in Bioanalysis
- Vol. 12 (16) , 1161-1194
Determination of Morphine and Its Metabolites in the Biological Samples: An Updated Review
Morphine (MO) as an opioid analgesic is used for the treatment of moderate-to-severe pains, particularly cancer-related pains. Pharmacologic studies on MO are complicated due to drugs binding to th...
- 1 June 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1117, 9-17
An optical sensing platform based on hexacyanoferrate intercalated layered double hydroxide nanozyme for determination of chromium in water
- 1 June 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1117, 9-17
An optical sensing platform based on hexacyanoferrate intercalated layered double hydroxide nanozyme for determination of chromium in water
- 28 January 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (6) , 1160-1169
Cauliflower‐like NiCo2O4−Zn/Al Layered Double Hydroxide Nanocomposite as an Efficient Electrochemical Sensing Platform for Selective Pyridoxine Detection
In the present study, a cauliflower‐like NiCo2O4−Zn/Al layered double hydroxide (NiCo2O4−Zn/Al LDH) nanocomposite was used as a novel electrode material for the sensitive and selective determination of pyridoxine (vitamin B6). The structure and morphology of the as‐prepared nanocomposite were characterized by X‐ray diffraction (XRD), FT‐IR, field emission scanning electron microscopy (FESEM) and energy dispersive X‐ray spectroscopy (EDX). The NiCo2O4−Zn/Al LDH nanocomposite exhibited excellent electrocatalytic ability in the oxidation of pyridoxine, which could result from the synergistic effect of the two components. The developed sensor also provided a selective determination of pyridoxine in the presence of other species such as vitamins (B1, B2, B12 and ascorbic acid), inorganic ions and biomolecules. The fabricated sensor showed a good linear response for pyridoxine over the concentration ranges 2×10−7–2.0×10−4 mol L−1 with a low detection limit of 8.6×10−8 mol L−1. Finally, the proposed method was successfully applied for the determination of pyridoxine in commercial tablets and plasma samples with satisfactory results. Furthermore, this novel sensor displayed superior benefits in terms of stability, sensitivity, repeatability and cost. The present work aims to expand NiCo2O4 based nanocomposites to sensor fields and promote the development of pyridoxine sensors.
- 28 January 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (6) , 1160-1169
Cauliflower‐like NiCo2O4−Zn/Al Layered Double Hydroxide Nanocomposite as an Efficient Electrochemical Sensing Platform for Selective Pyridoxine Detection
In the present study, a cauliflower‐like NiCo2O4−Zn/Al layered double hydroxide (NiCo2O4−Zn/Al LDH) nanocomposite was used as a novel electrode material for the sensitive and selective determination of pyridoxine (vitamin B6). The structure and morphology of the as‐prepared nanocomposite were characterized by X‐ray diffraction (XRD), FT‐IR, field emission scanning electron microscopy (FESEM) and energy dispersive X‐ray spectroscopy (EDX). The NiCo2O4−Zn/Al LDH nanocomposite exhibited excellent electrocatalytic ability in the oxidation of pyridoxine, which could result from the synergistic effect of the two components. The developed sensor also provided a selective determination of pyridoxine in the presence of other species such as vitamins (B1, B2, B12 and ascorbic acid), inorganic ions and biomolecules. The fabricated sensor showed a good linear response for pyridoxine over the concentration ranges 2×10−7–2.0×10−4 mol L−1 with a low detection limit of 8.6×10−8 mol L−1. Finally, the proposed method was successfully applied for the determination of pyridoxine in commercial tablets and plasma samples with satisfactory results. Furthermore, this novel sensor displayed superior benefits in terms of stability, sensitivity, repeatability and cost. The present work aims to expand NiCo2O4 based nanocomposites to sensor fields and promote the development of pyridoxine sensors.
- 17 April 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (19) , 7463-7470
Layered double hydroxide nanoparticles embedded in a biopolymer: a novel platform for electroanalytical determination of diazepam
This paper describes the development of a sensitive and efficient sensing platform based on a layered double hydroxide/poly(tyrosine) (LDH/poly(Tyr)) film for electrochemical determination of diazepam (DZ). The morphology and chemical composition of the LDH/poly(Tyr) film was illustrated by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) techniques. The electro-polymerization parameters of poly(Tyr) were discussed in detail. It was found that the reduction peak current of DZ was enhanced significantly on the film electrode. Under optimal experimental conditions, the calibration curve was linear over the DZ concentration range 2.0 × 10−7–6.0 × 10−5 mol L−1 with a detection limit (S/N = 3) of 7.8 × 10−8 mol L−1. The novel sensor developed in this study exhibited long-term stability, anti-interference ability and good reproducibility. Finally, the application of the proposed method in the analysis of real samples (commercial tablets and plasma samples) was also evaluated with satisfactory results, demonstrating that the LDH/poly(Tyr) film is a promising platform for accurate and reproducible detection of DZ.
- 17 April 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (19) , 7463-7470
Layered double hydroxide nanoparticles embedded in a biopolymer: a novel platform for electroanalytical determination of diazepam
This paper describes the development of a sensitive and efficient sensing platform based on a layered double hydroxide/poly(tyrosine) (LDH/poly(Tyr)) film for electrochemical determination of diazepam (DZ). The morphology and chemical composition of the LDH/poly(Tyr) film was illustrated by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) techniques. The electro-polymerization parameters of poly(Tyr) were discussed in detail. It was found that the reduction peak current of DZ was enhanced significantly on the film electrode. Under optimal experimental conditions, the calibration curve was linear over the DZ concentration range 2.0 × 10−7–6.0 × 10−5 mol L−1 with a detection limit (S/N = 3) of 7.8 × 10−8 mol L−1. The novel sensor developed in this study exhibited long-term stability, anti-interference ability and good reproducibility. Finally, the application of the proposed method in the analysis of real samples (commercial tablets and plasma samples) was also evaluated with satisfactory results, demonstrating that the LDH/poly(Tyr) film is a promising platform for accurate and reproducible detection of DZ.
- 27 December 2017
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (3) , 2140-2148
Layered double hydroxide decorated with Ag nanodendrites as an enhanced sensing platform for voltammetric determination of pyrazinamide
Herein, a sensitive electrochemical sensor for pyrazinamide (PZA) based on the electrodeposition of Ag nanodendrites (AgNDs) on a Zn–Al layered double hydroxide (LDH)-modified electrode was developed. The synthesized nanostructured materials were characterized by X-ray diffraction, Fourier transform IR spectroscopy, scanning electron microscopy, and energy dispersive X-ray analysis. In addition, voltammetric measurement of double layer capacitance was used to evaluate the real surface area of the AgND/LDH/GC electrode. Excellent electrocatalytic activity, high stability, anti-interference ability, and good reproducibility make this sensor a good candidate for trace PZA determination. Under optimal experimental conditions, the current response of the fabricated sensor obtained via differential pulse voltammetry increased linearly with PZA concentrations in the wide range from 9.0 × 10−7 to 5.2 × 10−4 mol L−1, and the detection limit was 7.2 × 10−7 mol L−1 (S/N = 3). The proposed sensor was successfully applied for the determination of PZA in commercial pharmaceutical tablets, and the obtained results were comparable to those found by the official analytical protocols. Finally, the developed method was validated by the analysis of PZA spiked human serum and urine samples, and good recoveries were obtained in the range of 97.5–105.5%.
- 27 December 2017
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (3) , 2140-2148
Layered double hydroxide decorated with Ag nanodendrites as an enhanced sensing platform for voltammetric determination of pyrazinamide
Herein, a sensitive electrochemical sensor for pyrazinamide (PZA) based on the electrodeposition of Ag nanodendrites (AgNDs) on a Zn–Al layered double hydroxide (LDH)-modified electrode was developed. The synthesized nanostructured materials were characterized by X-ray diffraction, Fourier transform IR spectroscopy, scanning electron microscopy, and energy dispersive X-ray analysis. In addition, voltammetric measurement of double layer capacitance was used to evaluate the real surface area of the AgND/LDH/GC electrode. Excellent electrocatalytic activity, high stability, anti-interference ability, and good reproducibility make this sensor a good candidate for trace PZA determination. Under optimal experimental conditions, the current response of the fabricated sensor obtained via differential pulse voltammetry increased linearly with PZA concentrations in the wide range from 9.0 × 10−7 to 5.2 × 10−4 mol L−1, and the detection limit was 7.2 × 10−7 mol L−1 (S/N = 3). The proposed sensor was successfully applied for the determination of PZA in commercial pharmaceutical tablets, and the obtained results were comparable to those found by the official analytical protocols. Finally, the developed method was validated by the analysis of PZA spiked human serum and urine samples, and good recoveries were obtained in the range of 97.5–105.5%.
- 29 September 2016
- Published by Wiley in Electroanalysis
- Vol. 29 (2) , 635-642
Nanostructured Hexacyanoferrate Intercalated Ni/Al Layered Double Hydroxide Modified Electrode as a Sensitive Electrochemical Sensor for Paracetamol Determination
An electrochemical sensor for paracetamol (PC) based on the hexacyanoferate(III) intercalated Ni−Al layered double hydroxide (Ni−Al−HCF) was presented. The as‐prepared LDH structurally and morphologically was characterized by scanning electron microscopy, X‐ray diffraction, and Fourier transform IR. Electrochemical studies revealed that Ni−Al−HCF film modified glassy carbon (GC) electrode exhibited remarkable electrocatalytic activity toward the oxidation of paracetamol. The electrochemical behavior of PC on the Ni−Al−HCF film was investigated in detail. Under optimum experimental conditions, the electrocatalytic response of the modified GC electrode was linear in the PC concentration range 3×10−6−–1.5×10−3 mol L−1, with a detection limit of 8×10−7 mol L−1 (S/N=3), using hydrodynamic amperometry. In addition, the modified electrode exhibited good reproducibility, long‐term stability and anti‐interference property. The fabricated sensor was successfully applied to determination of PC in various pharmaceutical preparations such as tablets, oral solution, and oral drops. Finally, the method was validated by the analysis of paracetamol spiked human serum samples, and good recoveries were obtained in the range of 99.2–103 %.
- 29 September 2016
- Published by Wiley in Electroanalysis
- Vol. 29 (2) , 635-642
Nanostructured Hexacyanoferrate Intercalated Ni/Al Layered Double Hydroxide Modified Electrode as a Sensitive Electrochemical Sensor for Paracetamol Determination
An electrochemical sensor for paracetamol (PC) based on the hexacyanoferate(III) intercalated Ni−Al layered double hydroxide (Ni−Al−HCF) was presented. The as‐prepared LDH structurally and morphologically was characterized by scanning electron microscopy, X‐ray diffraction, and Fourier transform IR. Electrochemical studies revealed that Ni−Al−HCF film modified glassy carbon (GC) electrode exhibited remarkable electrocatalytic activity toward the oxidation of paracetamol. The electrochemical behavior of PC on the Ni−Al−HCF film was investigated in detail. Under optimum experimental conditions, the electrocatalytic response of the modified GC electrode was linear in the PC concentration range 3×10−6−–1.5×10−3 mol L−1, with a detection limit of 8×10−7 mol L−1 (S/N=3), using hydrodynamic amperometry. In addition, the modified electrode exhibited good reproducibility, long‐term stability and anti‐interference property. The fabricated sensor was successfully applied to determination of PC in various pharmaceutical preparations such as tablets, oral solution, and oral drops. Finally, the method was validated by the analysis of paracetamol spiked human serum samples, and good recoveries were obtained in the range of 99.2–103 %.
- 3 March 2013
- Published by Springer Nature in Microchimica Acta
- Vol. 180 (7-8) , 619-626
Nickel-aluminum layered double hydroxide as a nano-sorbent for the solid phase extraction of selenium, and its determination by continuous flow HG-AAS
- 3 March 2013
- Published by Springer Nature in Microchimica Acta
- Vol. 180 (7-8) , 619-626
Nickel-aluminum layered double hydroxide as a nano-sorbent for the solid phase extraction of selenium, and its determination by continuous flow HG-AAS