Yu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yu Chen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Haoze Luo
Zhejiang University
4 shared publications - Wuhua Li
Zhejiang University
4 shared publications - Chengmin Li
Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications - Xiangning He
Zhejiang University
2 shared publications - Ankang Zhu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Guiyun Tian
Chongqing University of Technology
1 shared publication
Latest Publications
- 27 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 9673-9684
An Online Gate Oxide Degradation Monitoring Method for SiC MOSFETs With Contactless PCB Rogowski Coil Approach
Real-time degradation monitoring (DM) of the gate oxide is an effective method to improve the reliability of SiC mosfet applications . Currently, the existing DM methods generally require direct electrical connection with the device, which undoubtedly reduces the reliability of monitored system. This article proposes a contactless DM method based on the turn- on transient current rate with fixed delay time ( di/dt - Delay ), which is realized by a printed circuit board (PCB) Rogowski Coil. First, the effectiveness of di/dt - Delay as a degradation precursor is verified by high temperature gate-bias test. The results show that the maximum di/dt of planar and trench gate devices decreases gradually with the gate oxide degradation and finally decreases by 51.2% and 33.6%, respectively. Secondly, the low-temperature sensitivity of di/dt is verified, and the conclusion that the di/dt under short delay time is independent of drain-source voltage ( V DS ) and current ( I DS ) is given. Then, a di/dt- Delay extraction circuit based on PCB Rogowski Coil is designed, which has a measurement bandwidth of at least 38 MHz. The effectiveness of this real-time DM method is verified in a buck converter. The proposed method can provide a valuable tool for continuous health monitoring in emerging applications of SiC mosfet s to high-reliability applications.
- 27 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 9673-9684
An Online Gate Oxide Degradation Monitoring Method for SiC MOSFETs With Contactless PCB Rogowski Coil Approach
Real-time degradation monitoring (DM) of the gate oxide is an effective method to improve the reliability of SiC mosfet applications . Currently, the existing DM methods generally require direct electrical connection with the device, which undoubtedly reduces the reliability of monitored system. This article proposes a contactless DM method based on the turn- on transient current rate with fixed delay time ( di/dt - Delay ), which is realized by a printed circuit board (PCB) Rogowski Coil. First, the effectiveness of di/dt - Delay as a degradation precursor is verified by high temperature gate-bias test. The results show that the maximum di/dt of planar and trench gate devices decreases gradually with the gate oxide degradation and finally decreases by 51.2% and 33.6%, respectively. Secondly, the low-temperature sensitivity of di/dt is verified, and the conclusion that the di/dt under short delay time is independent of drain-source voltage ( V DS ) and current ( I DS ) is given. Then, a di/dt- Delay extraction circuit based on PCB Rogowski Coil is designed, which has a measurement bandwidth of at least 38 MHz. The effectiveness of this real-time DM method is verified in a buck converter. The proposed method can provide a valuable tool for continuous health monitoring in emerging applications of SiC mosfet s to high-reliability applications.
- 9 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (8) , 9298-9313
Graph-Model-Based Generative Layout Optimization for Heterogeneous SiC Multichip Power Modules With Reduced and Balanced Parasitic Inductance
Multichip silicon carbide power modules with integrated snubbers are promising for large-capacity converters with high speed and cost efficiency. In the design stage, the parasitic inductance of module layout generally attracts the primary efforts of designers because of its severe impact on dynamic performance, e.g., voltage overshoot and transient current imbalance. However, due to the complexity of the heterogeneous layout, the solution space and development efficiency are always limited by the traditional manual design approach. Thus, this article proposes a generative method to optimize the layout autonomously. First, a graph model is built to describe heterogeneous layouts with all interconnectivity and design constraints retained. Based on the model, integer programming is introduced to generate layout templates with variable geometric topologies. Then, coupled with a self-developed discrete extractor, the Pareto-front is obtained by genetic algorithm, providing a tradeoff boundary for loop inductance and branch mismatch. The proposed method is systematic, flexible, and requires few designers’ expertise. A 1200 V/240 A half-bridge module is designed and fabricated to validate its capability. The experimental results show that the loop inductance of 5.59 nH is achieved, and less than 5% of the transient current imbalance is realized under 6.2 A/ns turn- on in the rated.
- 9 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (8) , 9298-9313
Graph-Model-Based Generative Layout Optimization for Heterogeneous SiC Multichip Power Modules With Reduced and Balanced Parasitic Inductance
Multichip silicon carbide power modules with integrated snubbers are promising for large-capacity converters with high speed and cost efficiency. In the design stage, the parasitic inductance of module layout generally attracts the primary efforts of designers because of its severe impact on dynamic performance, e.g., voltage overshoot and transient current imbalance. However, due to the complexity of the heterogeneous layout, the solution space and development efficiency are always limited by the traditional manual design approach. Thus, this article proposes a generative method to optimize the layout autonomously. First, a graph model is built to describe heterogeneous layouts with all interconnectivity and design constraints retained. Based on the model, integer programming is introduced to generate layout templates with variable geometric topologies. Then, coupled with a self-developed discrete extractor, the Pareto-front is obtained by genetic algorithm, providing a tradeoff boundary for loop inductance and branch mismatch. The proposed method is systematic, flexible, and requires few designers’ expertise. A 1200 V/240 A half-bridge module is designed and fabricated to validate its capability. The experimental results show that the loop inductance of 5.59 nH is achieved, and less than 5% of the transient current imbalance is realized under 6.2 A/ns turn- on in the rated.
- 6 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (6) , 7299-7314
Thermal Mitigation and Optimization Via Multitier Bond Wire Layout for IGBT Modules Considering Multicellular Electro-Thermal Effect
The stitch wire configuration is widely adopted for large-area IGBT chips. However, an inhomogeneous wire current density introduces uneven self-heating and nonuniform chip heating, which exacerbates the chip thermal stress. In this article, a multicellular electro-thermal model considering the stitch-bonding wires is derived to optimize the wire layout parameters. Furthermore, the current density alleviation of wire bonds is investigated to be the most sensitive and effective method to comprehensively mitigate the thermal nonequilibrium and local overheating. Consequently, an improved multitier layout is proposed to further achieve thermal stress suppression without any additional components and advanced materials. Finally, a triple-tier-bonded IGBT module with optimal design parameters is fabricated to validate the thermal mitigation performance. The prototype experimental results demonstrate that the modeling error is less than 3.0%. The multitier layout decreases the current density by 57.6%, hence, the maximum and average chip temperature are reduced by 21.8% and 12.4%, respectively.
- 6 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (6) , 7299-7314
Thermal Mitigation and Optimization Via Multitier Bond Wire Layout for IGBT Modules Considering Multicellular Electro-Thermal Effect
The stitch wire configuration is widely adopted for large-area IGBT chips. However, an inhomogeneous wire current density introduces uneven self-heating and nonuniform chip heating, which exacerbates the chip thermal stress. In this article, a multicellular electro-thermal model considering the stitch-bonding wires is derived to optimize the wire layout parameters. Furthermore, the current density alleviation of wire bonds is investigated to be the most sensitive and effective method to comprehensively mitigate the thermal nonequilibrium and local overheating. Consequently, an improved multitier layout is proposed to further achieve thermal stress suppression without any additional components and advanced materials. Finally, a triple-tier-bonded IGBT module with optimal design parameters is fabricated to validate the thermal mitigation performance. The prototype experimental results demonstrate that the modeling error is less than 3.0%. The multitier layout decreases the current density by 57.6%, hence, the maximum and average chip temperature are reduced by 21.8% and 12.4%, respectively.
- Open Access
Non-Contact Degradation Evaluation for IGBT Modules Using Eddy Current Pulsed Thermography Approach
In this paper, a non-contact degradation evaluation method for insulated gate bipolar transistor (IGBT) modules is proposed based on eddy current pulsed thermography approach. In non-contact heat excitation procedures, a high-power induction heater is introduced to generate heat excitation in IGBT modules. The thermographs of the whole temperature mapping are recorded non-invasively by an IR camera. As a result, the joint degradation of IGBT modules can be evaluated by the transient thermal response curves derived from the recorded thermographs. Firstly, the non-destructive evaluation principle of the eddy current pulsed thermography (ECPT) system for an IGBT module with a heat sink is introduced. A 3D simulation module is built with physical parameters in ANSYS simulations, and then thermal propagation behavior considering the degradation impact is investigated. An experimental ECPT system is set up to verify the effectiveness of the proposed method. The experimental results show that the delay time to peak temperature can be extracted and treated as an effective indicative feature of joint degradation.
Open AccessNon-Contact Degradation Evaluation for IGBT Modules Using Eddy Current Pulsed Thermography Approach
In this paper, a non-contact degradation evaluation method for insulated gate bipolar transistor (IGBT) modules is proposed based on eddy current pulsed thermography approach. In non-contact heat excitation procedures, a high-power induction heater is introduced to generate heat excitation in IGBT modules. The thermographs of the whole temperature mapping are recorded non-invasively by an IR camera. As a result, the joint degradation of IGBT modules can be evaluated by the transient thermal response curves derived from the recorded thermographs. Firstly, the non-destructive evaluation principle of the eddy current pulsed thermography (ECPT) system for an IGBT module with a heat sink is introduced. A 3D simulation module is built with physical parameters in ANSYS simulations, and then thermal propagation behavior considering the degradation impact is investigated. An experimental ECPT system is set up to verify the effectiveness of the proposed method. The experimental results show that the delay time to peak temperature can be extracted and treated as an effective indicative feature of joint degradation.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (7) , 6108-6122
A Coupled-Inductor-Based LCC Resonant Converter With the Primary-Parallel–Secondary-Series Configuration to Achieve Output-Voltage Sharing for HV Generator Applications
In this paper, a coupled-inductor based LCC resonant converter with the primary-parallel-secondary-series (PPSS) configuration is proposed to achieve output-voltage sharing ability for the HV generator applications. The PPSS configuration of the LCC resonant converter with voltage multipliers is introduced to achieve high output-voltage and increase the output-power level. However, the variations of the magnetizing inductance, leakage inductance and winding capacitance of the HV transformer and voltage multiplier impact on the output-voltage sharing. Subsequently, the resonant inductors in the primary side of the conventional LCC resonant converters with the PPSS configuration are coupled to achieve the output-voltage sharing without any additional circuits and control efforts. Furthermore, an analytical equivalent circuit model considering the magnetizing inductor of the HV transformer is derived to analyze the output-voltage sharing ability. Moreover, the design method for the coupled inductors considering the output-voltage sharing affected by the leakage inductance of the coupled inductors is presented. Finally, the output-voltage sharing of the proposed coupled-inductor based LCC resonant converter with the PPSS configuration is validated by the experimental results of a 50V input, 5kV output 100W prototype. The experimental results show that the unbalance voltage degree decreases from 67.7% to 8.5% with the utilization of the coupled-inductor.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (7) , 6108-6122
A Coupled-Inductor-Based LCC Resonant Converter With the Primary-Parallel–Secondary-Series Configuration to Achieve Output-Voltage Sharing for HV Generator Applications
In this paper, a coupled-inductor based LCC resonant converter with the primary-parallel-secondary-series (PPSS) configuration is proposed to achieve output-voltage sharing ability for the HV generator applications. The PPSS configuration of the LCC resonant converter with voltage multipliers is introduced to achieve high output-voltage and increase the output-power level. However, the variations of the magnetizing inductance, leakage inductance and winding capacitance of the HV transformer and voltage multiplier impact on the output-voltage sharing. Subsequently, the resonant inductors in the primary side of the conventional LCC resonant converters with the PPSS configuration are coupled to achieve the output-voltage sharing without any additional circuits and control efforts. Furthermore, an analytical equivalent circuit model considering the magnetizing inductor of the HV transformer is derived to analyze the output-voltage sharing ability. Moreover, the design method for the coupled inductors considering the output-voltage sharing affected by the leakage inductance of the coupled inductors is presented. Finally, the output-voltage sharing of the proposed coupled-inductor based LCC resonant converter with the PPSS configuration is validated by the experimental results of a 50V input, 5kV output 100W prototype. The experimental results show that the unbalance voltage degree decreases from 67.7% to 8.5% with the utilization of the coupled-inductor.