Antti Kosonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antti Kosonen has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Jero Ahola
School of Energy Systems, Lappeenranta-Lahti University of Technology (LUT), Lappeenranta, Finland
19 shared publications - Pertti Kauranen
School of Energy Systems, LUT University, Lappeenranta, Finland
15 shared publications - Vesa Ruuskanen
Lappeenranta University of Technology, Lappeenranta, Finland
14 shared publications - Altti Meriläinen
Lappeenranta-Lahti University of Technology LUT
10 shared publications Jero Ahola
5 shared publicationsMarkku Niemelä
5 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by Elsevier in SSRN Electronic Journal
Reducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid electrolyzer plant for use in a solid-sorbent DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed.It was found that the electrolyzer plant producing 6.3 kt/a of H2 can provide heat for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps.From an electricity system perspective, the use of waste heat sources to supply heat to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- 8 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessReducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid electrolyzer plant for use in a solid-sorbent DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed.It was found that the electrolyzer plant producing 6.3 kt/a of H2 can provide heat for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps.From an electricity system perspective, the use of waste heat sources to supply heat to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- Open Access
- 4 July 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 179
Profitability optimized bidirectional electric vehicle charging in a Nordic prosumer household
- 4 July 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 179
Open AccessProfitability optimized bidirectional electric vehicle charging in a Nordic prosumer household
- Open Access
- 28 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Impact of series-connected stacks on shunt currents in an industrial-scale alkaline water electrolyser system
- 28 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Open AccessImpact of series-connected stacks on shunt currents in an industrial-scale alkaline water electrolyser system
- Open Access
- 25 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Effect of pressure and thermal management on stray currents in alkaline water electrolyser stacks
- 25 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Open AccessEffect of pressure and thermal management on stray currents in alkaline water electrolyser stacks
- Open Access
- 18 April 2026
- Published by Elsevier in SSRN Electronic Journal
Reducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal (CDR) through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid alkaline water electrolyzer (AWE) plant for use in a solid-sorbent-based DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed. It was found that the AWE plant producing 6.3 kt/a of H2 can provide thermal energy for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature from 80◦C to 100◦C or 120◦C significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps. From an electricity system perspective, the use of waste heat sources to supply thermal energy to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- 18 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessReducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal (CDR) through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid alkaline water electrolyzer (AWE) plant for use in a solid-sorbent-based DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed. It was found that the AWE plant producing 6.3 kt/a of H2 can provide thermal energy for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature from 80◦C to 100◦C or 120◦C significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps. From an electricity system perspective, the use of waste heat sources to supply thermal energy to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- Open Access
- 23 December 2025
- Published by Elsevier in Solar Energy
- Vol. 305
Net metering interval impact on solar photovoltaic prosumer techno-economics in Finland
- 23 December 2025
- Published by Elsevier in Solar Energy
- Vol. 305
Open AccessNet metering interval impact on solar photovoltaic prosumer techno-economics in Finland