Pertti Kauranen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Pertti Kauranen has a total of 134 co-authors. Here are the top co-authors by number of shared publications:
- Jero Ahola
School of Energy Systems, Lappeenranta-Lahti University of Technology (LUT), Lappeenranta, Finland
21 shared publications - Antti Kosonen
Department of Electrical Engineering, Lappeenranta-Lahti University of Technology (LUT), Lappeenranta, Finland
15 shared publications - Vesa Ruuskanen
Lappeenranta University of Technology, Lappeenranta, Finland
14 shared publications - Altti Meriläinen
Lappeenranta-Lahti University of Technology LUT
8 shared publications Vesa Ruuskanen
8 shared publicationsJero Ahola
6 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Elsevier in SSRN Electronic Journal
Weather-aware energy prediction for battery electric trucks from fleet telematics and road weather data
In regional freight operation, route, payload, and charging plans for battery electric trucks depend on trip energy. In Nordic winters this demand varies with temperature and road-surface state, which vehicle energy models omit by treating auxiliary demand as constant and rolling resistance as independent of weather. This study predicts the trip-level energy consumption of a battery electric truck in commercial service in Finland and Sweden from 18 months of telematics, matched along the route to road-weather analyses of temperature, water film, and surface snow. A calibrated longitudinal-dynamics model is combined with a gradient-boosting correction and evaluated on held-out trips, months, and an unseen winter. The physics residual rises from slightly below zero above 15◦C to 50 kWh/100km below -15◦C, each 1◦C drop adding 1.17 kWh/100km, and neither a constant-power auxiliary load nor a load-proportional rolling loss reproduces it alone. A 0.15 mm water film adds 8.4 kWh/100km and snow cover 6.8 kWh/100km plus 7.8 kWh/100km per centimeter, independently of temperature, so consumption peaks near 0◦C. On unseen trips thecorrection raises the R2 of total consumption from 0.40 to 0.87 and recovers 53% of the residual variance, 41% for an unseen winter, twice what a temperature-dependent auxiliary load achieves. A wet, snowy day at -20◦C shortens the range of a fully loaded truck from about 260 km to 185–195 km. A diesel truck analyzed as a reference shows that fleet fuel-level signals are too coarse for such prediction.
- 12 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessWeather-aware energy prediction for battery electric trucks from fleet telematics and road weather data
In regional freight operation, route, payload, and charging plans for battery electric trucks depend on trip energy. In Nordic winters this demand varies with temperature and road-surface state, which vehicle energy models omit by treating auxiliary demand as constant and rolling resistance as independent of weather. This study predicts the trip-level energy consumption of a battery electric truck in commercial service in Finland and Sweden from 18 months of telematics, matched along the route to road-weather analyses of temperature, water film, and surface snow. A calibrated longitudinal-dynamics model is combined with a gradient-boosting correction and evaluated on held-out trips, months, and an unseen winter. The physics residual rises from slightly below zero above 15◦C to 50 kWh/100km below -15◦C, each 1◦C drop adding 1.17 kWh/100km, and neither a constant-power auxiliary load nor a load-proportional rolling loss reproduces it alone. A 0.15 mm water film adds 8.4 kWh/100km and snow cover 6.8 kWh/100km plus 7.8 kWh/100km per centimeter, independently of temperature, so consumption peaks near 0◦C. On unseen trips thecorrection raises the R2 of total consumption from 0.40 to 0.87 and recovers 53% of the residual variance, 41% for an unseen winter, twice what a temperature-dependent auxiliary load achieves. A wet, snowy day at -20◦C shortens the range of a fully loaded truck from about 260 km to 185–195 km. A diesel truck analyzed as a reference shows that fleet fuel-level signals are too coarse for such prediction.
- Open Access
- 17 September 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Cost comparison of low- and zero-emission heavy-duty vehicles: a case route analysis
- 17 September 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Open AccessCost comparison of low- and zero-emission heavy-duty vehicles: a case route analysis
- Open Access
- 17 September 2026
- Published by Elsevier in Journal of Cleaner Production
- Vol. 577
Reducing the idle times of forest machines: A scenario analysis with machine big data in Finland
- 17 September 2026
- Published by Elsevier in Journal of Cleaner Production
- Vol. 577
Open AccessReducing the idle times of forest machines: A scenario analysis with machine big data in Finland
- Open Access
- 8 July 2026
- Published by Elsevier in SSRN Electronic Journal
Reducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid electrolyzer plant for use in a solid-sorbent DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed.It was found that the electrolyzer plant producing 6.3 kt/a of H2 can provide heat for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps.From an electricity system perspective, the use of waste heat sources to supply heat to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- 8 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessReducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid electrolyzer plant for use in a solid-sorbent DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed.It was found that the electrolyzer plant producing 6.3 kt/a of H2 can provide heat for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps.From an electricity system perspective, the use of waste heat sources to supply heat to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- Open Access
- 17 June 2026
- Published by Elsevier in Cleaner Energy Systems
- Vol. 14
Evaluating costs and potential emission reductions from electrification of cargo handling equipment in a seaport
- 17 June 2026
- Published by Elsevier in Cleaner Energy Systems
- Vol. 14
Open AccessEvaluating costs and potential emission reductions from electrification of cargo handling equipment in a seaport
- Open Access
- 2 May 2026
- Published by Elsevier in Chemical Engineering Science
- Vol. 332
Mass transfer modeling of gas–liquid separators during standby operation of alkaline water electrolyzers
- 2 May 2026
- Published by Elsevier in Chemical Engineering Science
- Vol. 332
Open AccessMass transfer modeling of gas–liquid separators during standby operation of alkaline water electrolyzers
- Open Access
- 28 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Impact of series-connected stacks on shunt currents in an industrial-scale alkaline water electrolyser system
- 28 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Open AccessImpact of series-connected stacks on shunt currents in an industrial-scale alkaline water electrolyser system
- Open Access
- 25 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Effect of pressure and thermal management on stray currents in alkaline water electrolyser stacks
- 25 April 2026
- Published by Elsevier in Journal of Power Sources
- Vol. 679
Open AccessEffect of pressure and thermal management on stray currents in alkaline water electrolyser stacks
- Open Access
- 18 April 2026
- Published by Elsevier in SSRN Electronic Journal
Reducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal (CDR) through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid alkaline water electrolyzer (AWE) plant for use in a solid-sorbent-based DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed. It was found that the AWE plant producing 6.3 kt/a of H2 can provide thermal energy for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature from 80◦C to 100◦C or 120◦C significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps. From an electricity system perspective, the use of waste heat sources to supply thermal energy to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.
- 18 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessReducing the cost of solid sorbent direct air carbon capture by recovering waste heat from water electrolysis under Nordic conditions
Reducing the atmospheric CO2 concentration to a sustainable level requires large-scale carbon dioxide removal (CDR) through direct air capture (DAC). DAC is a heat-intensive process, and waste heat recovery to supply its heat demand has substantial potential to reduce the levelized cost of DAC (LCODAC). This study determines the techno-economic potential of recovering low-temperature waste heat (70◦C) from an off-grid alkaline water electrolyzer (AWE) plant for use in a solid-sorbent-based DAC plant requiring heat at 80◦C–120◦C for desorption. The waste heat recovery system, comprising heat pumps and a heat storage, and the DAC plant are dimensioned to minimize the LCODAC based on optimization at an hourly level, and a comparison with an electric-boiler-based heat supply is performed. It was found that the AWE plant producing 6.3 kt/a of H2 can provide thermal energy for a DAC plant capturing up to 27 kt/a of CO2 under Nordic conditions, where low ambient temperatures are beneficial for the solid DAC process, except for subzero temperatures. The LCODAC can be reduced by 24%–39% when a waste-heat-based heat supply is used instead of an electric boiler. Increasing the desorption temperature from 80◦C to 100◦C or 120◦C significantly reduces the LCODAC, even though the cost of heat supply increases due to the decreasing coefficient of performance of the heat pumps. From an electricity system perspective, the use of waste heat sources to supply thermal energy to DAC plants is highly beneficial, as the primary energy demand and the peak electrical power of the DAC process can be reduced by 60% and 55%, respectively, compared with an electric boiler.