Rachamadugu Kiranmayi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rachamadugu Kiranmayi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Shaik Hussain Vali
Assistant Professor, Department of Electrical and Electronics Engineering, JNTUA College of Engineering, Pulivendula, Kadapa, India
2 shared publications - D. Krishna
Department of Electrical and Electronics Engineering, Anurag University, Hyderabad 500088, India
1 shared publication - Ganesh Vulasala
JNTUA Coll Engn, Dept EEE, Pulivendula 516390, India
1 shared publication - M. Sasikala
Faculty of Engineering & Technology (Exclusively for Women), Sharnbasva University, Kalaburagi, India
1 shared publication M. Yerri Veeresh
Department of EEE, Jawaharlal Nehru Technological University Anantapur, India | Santhiram Engineering College, India
1 shared publication- S. Khadarvali
Electrical and Electronics Engineering Department, Jawaharlal Nehru Technological University Anantapur, Ananthapuramu, Anantapur 515002, Andhra Pradesh, India
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 15 (vol15i3) , 488-502
PV Model Parameters Extraction using Opposition-Based Learning Flow Direction Algorithm
PV Model Parameters Extraction using Opposition-Based Learning Flow Direction Algorithm
- 1 January 2025
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 15 (vol15i3) , 488-502
Open AccessPV Model Parameters Extraction using Opposition-Based Learning Flow Direction Algorithm
PV Model Parameters Extraction using Opposition-Based Learning Flow Direction Algorithm
- Open Access
- 15 December 2022
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 12 (6) , 9737-9741
Modeling and Analysis of Time Response Parameters of a PMSM-Based Electric Vehicle with PI and PID Controllers
This paper presents the mathematical modeling of a vector-controlled Permanent Magnet Synchronous Motor (PMSM) drive with either a Proportional Integral (PI) controller or a Proportional Integral Derivative (PID) controller as a propulsion system for an Electric Vehicle (EV). Most commercial drives use a standard PI controller as a speed regulator. The vector control system model consists of the PMSM, a PWM inverter, the speed controller, and vehicle dynamics for speed control. The performance analysis of the drive is evaluated under transient conditions for settling time, rise time, steady state error of speed, and the vehicle’s acceleration at the wheel axle for specifically designated values validated by MATLAB/Simulink.
- 15 December 2022
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 12 (6) , 9737-9741
Open AccessModeling and Analysis of Time Response Parameters of a PMSM-Based Electric Vehicle with PI and PID Controllers
This paper presents the mathematical modeling of a vector-controlled Permanent Magnet Synchronous Motor (PMSM) drive with either a Proportional Integral (PI) controller or a Proportional Integral Derivative (PID) controller as a propulsion system for an Electric Vehicle (EV). Most commercial drives use a standard PI controller as a speed regulator. The vector control system model consists of the PMSM, a PWM inverter, the speed controller, and vehicle dynamics for speed control. The performance analysis of the drive is evaluated under transient conditions for settling time, rise time, steady state error of speed, and the vehicle’s acceleration at the wheel axle for specifically designated values validated by MATLAB/Simulink.
- Open Access
Artificial Neural Network Controller in Two-Area and Five-Area System with Security Attack and Game-Theory Based Defender Action
Smart grids are the latest technology to generate and dispatch an optimal amount of power. Thus, there is a need for stability analysis in smart grid systems. If the smart grid is incorporated into the power system, then the phasor measurement unit (PMU) is used to measure the voltage, current, and frequency. Additionally, the central control unit monitors and controls the power. However, there is a possibility of inserting wrong data into the smart grid as the PMUs are transmitting the data through the Internet and other wireless protocols. There is a need to find solutions to this threat to make the power flow safe and secure in the future. In this paper, two-area load frequency control (LFC) is used for testing the game-theory based security treatment and improving the system’s stability by using an artificial neural network. The two-area system and five-area system are used to test the stability of the power system.
Open AccessArtificial Neural Network Controller in Two-Area and Five-Area System with Security Attack and Game-Theory Based Defender Action
Smart grids are the latest technology to generate and dispatch an optimal amount of power. Thus, there is a need for stability analysis in smart grid systems. If the smart grid is incorporated into the power system, then the phasor measurement unit (PMU) is used to measure the voltage, current, and frequency. Additionally, the central control unit monitors and controls the power. However, there is a possibility of inserting wrong data into the smart grid as the PMUs are transmitting the data through the Internet and other wireless protocols. There is a need to find solutions to this threat to make the power flow safe and secure in the future. In this paper, two-area load frequency control (LFC) is used for testing the game-theory based security treatment and improving the system’s stability by using an artificial neural network. The two-area system and five-area system are used to test the stability of the power system.
- 17 January 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (3) , 1543-1554
FOPI and FOFL Controller Based UPQC for Mitigation of Power Quality Problems in Distribution Power System
- 17 January 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 17 (3) , 1543-1554
FOPI and FOFL Controller Based UPQC for Mitigation of Power Quality Problems in Distribution Power System
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (2) , 81-90
BOND GRAPH MODELLING AND DESIGN OF BOOST ZCS QUASI RESONANT DC-DC POWER CONVERTER
Conventional pulse width modulated (PWM) converters have limited applications at higher frequency values. Switching losses and stresses are high. Quasi-resonant DC-DC converters can solve these problems. The quasi-resonant DC-DC converters work on either zero voltage or zero current switching concepts. They switched their states when either the voltage or the current is zero. Using bond graphs, a boost zero current switching (ZCS) quasi-resonant DC-DC power converter is modelled. The steady-state, large-signal and small-signal AC bond graph models of the converter are developed. The developed model is simulated in MATLAB/SIMULINK. The simulated results of the developed bond graph model are compared with the PSIM simulated results of the circuit model and experimental results. The efficiency and other performance parameters of the boost zero current switching (ZCS) quasi-resonant DC-DC power converter are compared experimentally with those of the PWM boost converter.
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (2) , 81-90
BOND GRAPH MODELLING AND DESIGN OF BOOST ZCS QUASI RESONANT DC-DC POWER CONVERTER
Conventional pulse width modulated (PWM) converters have limited applications at higher frequency values. Switching losses and stresses are high. Quasi-resonant DC-DC converters can solve these problems. The quasi-resonant DC-DC converters work on either zero voltage or zero current switching concepts. They switched their states when either the voltage or the current is zero. Using bond graphs, a boost zero current switching (ZCS) quasi-resonant DC-DC power converter is modelled. The steady-state, large-signal and small-signal AC bond graph models of the converter are developed. The developed model is simulated in MATLAB/SIMULINK. The simulated results of the developed bond graph model are compared with the PSIM simulated results of the circuit model and experimental results. The efficiency and other performance parameters of the boost zero current switching (ZCS) quasi-resonant DC-DC power converter are compared experimentally with those of the PWM boost converter.
- Open Access
- 1 December 2020
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 8 (2) , 426-441
Design of Zero Voltage Switching Boost DC-DC Converter Using Bond Graph Model
The research in power supply design is moving towards improving efficiency by reducing losses. Another aspect of research in power converters is its modeling as it involves multiple domains such as electrical, mechanical, magnetic...etc. bond graph modeling is suitable for the multi domain systems. Here, a zero voltage switching boost converter is designed using its bond graph model. The bond graph simulated results which are done in MATLAB/SIMULINK are matched with the experimental results. The developed bond graph model results are compared with experimental results. The efficiency of the ZVS boost converter is calculated and is compared with the efficiency of conventional pulse width modulated (PWM) boost converter.
- 1 December 2020
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 8 (2) , 426-441
Open AccessDesign of Zero Voltage Switching Boost DC-DC Converter Using Bond Graph Model
The research in power supply design is moving towards improving efficiency by reducing losses. Another aspect of research in power converters is its modeling as it involves multiple domains such as electrical, mechanical, magnetic...etc. bond graph modeling is suitable for the multi domain systems. Here, a zero voltage switching boost converter is designed using its bond graph model. The bond graph simulated results which are done in MATLAB/SIMULINK are matched with the experimental results. The developed bond graph model results are compared with experimental results. The efficiency of the ZVS boost converter is calculated and is compared with the efficiency of conventional pulse width modulated (PWM) boost converter.
- 15 May 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 42 (14) , 1643-1648
Performance evaluation of PMSG-based LFAC system for offshore wind power
Now a days, it is an interesting approach about the practice of Low frequency AC (LFAC) transmission and grid integration for the multi mega-watt (MW) long distances. The LFAC approach has ability to solve the charging current problem in underground AC cables and is an alternative to the conventional offshore transmission schemes. This paper presents the PMSG based LFAC transmission for offshore wind power to integrate the onshore grid. The PMSG-based offshore wind power is integrated onshore grid via LFAC and HVAC for comparison. The Machine Side Converter (MSC) extracts the maximum power from the wind and maintains the generator terminal voltage, whereas Grid Side Converter (GSC) maintains the constant DC link voltage by adjusting the dq currents of the grid. The simulation results demonstrate and verify the significant improvement in the power transfer capability, reduced power loss and control schemes performance. The complete work is modeled and analyzed using PSCAD/EMTDC.
- 15 May 2019
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 42 (14) , 1643-1648
Performance evaluation of PMSG-based LFAC system for offshore wind power
Now a days, it is an interesting approach about the practice of Low frequency AC (LFAC) transmission and grid integration for the multi mega-watt (MW) long distances. The LFAC approach has ability to solve the charging current problem in underground AC cables and is an alternative to the conventional offshore transmission schemes. This paper presents the PMSG based LFAC transmission for offshore wind power to integrate the onshore grid. The PMSG-based offshore wind power is integrated onshore grid via LFAC and HVAC for comparison. The Machine Side Converter (MSC) extracts the maximum power from the wind and maintains the generator terminal voltage, whereas Grid Side Converter (GSC) maintains the constant DC link voltage by adjusting the dq currents of the grid. The simulation results demonstrate and verify the significant improvement in the power transfer capability, reduced power loss and control schemes performance. The complete work is modeled and analyzed using PSCAD/EMTDC.