Shaik Hussain Vali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shaik Hussain Vali has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Rachamadugu Kiranmayi
Jawaharlal Nehru Technological University, Anantapur
2 shared publications - D Krishna Praveen
PG Student, Department of Electrical and Electronics Engineering, JNTUA College of Engineering, Pulivendula, Kadapa, India
1 shared publication - Ganesh Vulasala
JNTUA Coll Engn, Dept EEE, Pulivendula 516390, India
1 shared publication - Vempalle Rafi
JNTUA College of Engineering Pulivendula
1 shared publication
Latest Publications
- Open Access
- 1 November 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2070 (1) , 012134
A Novel Fast Hybrid Frequency Domain Approach for Evaluating Harmonic Power Flow in Electricity Networks
Ideally, an AC power supply should constantly provide a perfectly sinusoidal voltage signal at every customer location. Nowadays, many power electronic equipment’s are used in industry in seeking higher system reliability and efficiency and more electronic or microprocessor controllers are used in power system to control AC/DC transmission lines or loads. Moreover, the importance of green energy such as wind and solar is continually growing in our societies not only due to environmental concerns but also to resolve the problem of access to electricity in rural areas. As a result of these issues, power quality problems especially generation of harmonics are on the rise in the distribution network. In electrical power system, harmonics have a number of undesirable effects on power system devices as well as on their operation. It therefore becomes imperative for power system engineers to analyse the penetration of harmonics from the various sources into the network which commonly is known as harmonic power flow evaluation. This paper proposed a novel fast hybrid frequency domain approach (FHA) to evaluate the steady state harmonic power flow with discrete harmonic frequency. The proposed method is applied to IEEE – 14 bus, IEEE New England 39 - bus, IEEE – 57 bus and IEEE 118 - bus power system respectively and compared with Newton – Raphson (NR) load flow method and Fast decoupled load flow method (FDLF) and the results validate the accuracy, robustness and authenticity of the proposed method.
- 1 November 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2070 (1) , 012134
Open AccessA Novel Fast Hybrid Frequency Domain Approach for Evaluating Harmonic Power Flow in Electricity Networks
Ideally, an AC power supply should constantly provide a perfectly sinusoidal voltage signal at every customer location. Nowadays, many power electronic equipment’s are used in industry in seeking higher system reliability and efficiency and more electronic or microprocessor controllers are used in power system to control AC/DC transmission lines or loads. Moreover, the importance of green energy such as wind and solar is continually growing in our societies not only due to environmental concerns but also to resolve the problem of access to electricity in rural areas. As a result of these issues, power quality problems especially generation of harmonics are on the rise in the distribution network. In electrical power system, harmonics have a number of undesirable effects on power system devices as well as on their operation. It therefore becomes imperative for power system engineers to analyse the penetration of harmonics from the various sources into the network which commonly is known as harmonic power flow evaluation. This paper proposed a novel fast hybrid frequency domain approach (FHA) to evaluate the steady state harmonic power flow with discrete harmonic frequency. The proposed method is applied to IEEE – 14 bus, IEEE New England 39 - bus, IEEE – 57 bus and IEEE 118 - bus power system respectively and compared with Newton – Raphson (NR) load flow method and Fast decoupled load flow method (FDLF) and the results validate the accuracy, robustness and authenticity of the proposed method.
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (2) , 81-90
BOND GRAPH MODELLING AND DESIGN OF BOOST ZCS QUASI RESONANT DC-DC POWER CONVERTER
Conventional pulse width modulated (PWM) converters have limited applications at higher frequency values. Switching losses and stresses are high. Quasi-resonant DC-DC converters can solve these problems. The quasi-resonant DC-DC converters work on either zero voltage or zero current switching concepts. They switched their states when either the voltage or the current is zero. Using bond graphs, a boost zero current switching (ZCS) quasi-resonant DC-DC power converter is modelled. The steady-state, large-signal and small-signal AC bond graph models of the converter are developed. The developed model is simulated in MATLAB/SIMULINK. The simulated results of the developed bond graph model are compared with the PSIM simulated results of the circuit model and experimental results. The efficiency and other performance parameters of the boost zero current switching (ZCS) quasi-resonant DC-DC power converter are compared experimentally with those of the PWM boost converter.
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (2) , 81-90
BOND GRAPH MODELLING AND DESIGN OF BOOST ZCS QUASI RESONANT DC-DC POWER CONVERTER
Conventional pulse width modulated (PWM) converters have limited applications at higher frequency values. Switching losses and stresses are high. Quasi-resonant DC-DC converters can solve these problems. The quasi-resonant DC-DC converters work on either zero voltage or zero current switching concepts. They switched their states when either the voltage or the current is zero. Using bond graphs, a boost zero current switching (ZCS) quasi-resonant DC-DC power converter is modelled. The steady-state, large-signal and small-signal AC bond graph models of the converter are developed. The developed model is simulated in MATLAB/SIMULINK. The simulated results of the developed bond graph model are compared with the PSIM simulated results of the circuit model and experimental results. The efficiency and other performance parameters of the boost zero current switching (ZCS) quasi-resonant DC-DC power converter are compared experimentally with those of the PWM boost converter.
- Open Access
- 1 December 2020
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 8 (2) , 426-441
Design of Zero Voltage Switching Boost DC-DC Converter Using Bond Graph Model
The research in power supply design is moving towards improving efficiency by reducing losses. Another aspect of research in power converters is its modeling as it involves multiple domains such as electrical, mechanical, magnetic...etc. bond graph modeling is suitable for the multi domain systems. Here, a zero voltage switching boost converter is designed using its bond graph model. The bond graph simulated results which are done in MATLAB/SIMULINK are matched with the experimental results. The developed bond graph model results are compared with experimental results. The efficiency of the ZVS boost converter is calculated and is compared with the efficiency of conventional pulse width modulated (PWM) boost converter.
- 1 December 2020
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 8 (2) , 426-441
Open AccessDesign of Zero Voltage Switching Boost DC-DC Converter Using Bond Graph Model
The research in power supply design is moving towards improving efficiency by reducing losses. Another aspect of research in power converters is its modeling as it involves multiple domains such as electrical, mechanical, magnetic...etc. bond graph modeling is suitable for the multi domain systems. Here, a zero voltage switching boost converter is designed using its bond graph model. The bond graph simulated results which are done in MATLAB/SIMULINK are matched with the experimental results. The developed bond graph model results are compared with experimental results. The efficiency of the ZVS boost converter is calculated and is compared with the efficiency of conventional pulse width modulated (PWM) boost converter.