WZWenyi Zhu

Wenyi Zhu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wenyi Zhu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Machine Learning and Deep Learning for Diagnosis of Lumbar Spinal Stenosis: Systematic Review and Meta-Analysis

    by Tianyi Wang, Ruiyuan Chen, Ning Fan, Lei Zang, Shuo Yuan, Peng Du, Qichao Wu, Aobo Wang, Jian Li, Xiaochuan Kong, et al.

    Background: Lumbar spinal stenosis (LSS) is a major cause of pain and disability in older individuals worldwide. Although increasing studies of traditional machine learning (TML) and deep learning (DL) were conducted in the field of diagnosing LSS and gained prominent results, the performance of these models has not been analyzed systematically. Objective: This systematic review and meta-analysis aimed to pool the results and evaluate the heterogeneity of the current studies in using TML or DL models to diagnose LSS, thereby providing more comprehensive information for further clinical application. Methods: This review was performed under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Embase databases, and Cochrane Library databases. Studies that evaluated DL or TML algorithms assessment value on diagnosing LSS were included, while those with duplicated or unavailable data were excluded. Quality Assessment of Diagnostic Accuracy Studies 2 was used to estimate the risk of bias in each study. The MIDAS module and the METAPROP module of Stata (StataCorp) were used for data synthesis and statistical analyses. Results: A total of 12 studies with 15,044 patients reported the assessment value of TML or DL models for diagnosing LSS. The risk of bias assessment yielded 4 studies with high risk of bias, 3 with unclear risk of bias, and 5 with completely low risk of bias. The pooled sensitivity and specificity were 0.84 (95% CI: 0.82-0.86; I2=99.06%) and 0.87 (95% CI 0.84-0.90; I2=98.7%), respectively. The diagnostic odds ratio was 36 (95% CI 26-49), the positive likelihood ratio (LR+) was 6.6 (95% CI 5.1-8.4), and the negative likelihood ratio (LR–) was 0.18 (95% CI 0.16-0.21). The summary receiver operating characteristic curves, the area under the curve of TML or DL models for diagnosing LSS of 0.92 (95% CI 0.89-0.94), indicating a high diagnostic value. Conclusions: This systematic review and meta-analysis emphasize that despite the generally satisfactory diagnostic performance of artificial intelligence systems in the experimental stage for the diagnosis of LSS, none of them is reliable and practical enough to apply in real clinical practice. Further efforts, including optimization of model balance, widely accepted objective reference standards, multimodal strategy, large dataset for training and testing, external validation, and sufficient and scientific report, should be made to bridge the distance between current TML or DL models and real-life clinical applications in future studies. Trial Registration: PROSPERO CRD42024566535; https://tinyurl.com/msx59x8k


  • Open Access

    Machine Learning and Deep Learning for Diagnosis of Lumbar Spinal Stenosis: Systematic Review and Meta-Analysis (Preprint)

    by Tianyi Wang, Ruiyuan Chen, Ning Fan, Lei Zang, Shuo Yuan, Peng Du, Qichao Wu, Aobo Wang, Jian Li, Xiaochuan Kong, et al.

    BACKGROUND Lumbar spinal stenosis (LSS) is a major cause of pain and disability in older individuals worldwide. Although increasing studies of traditional machine learning (TML) and deep learning (DL) were conducted in the field of diagnosing LSS and gained prominent results, the performance of these models has not been analyzed systematically. OBJECTIVE This systematic review and meta-analysis aimed to pool the results and evaluate the heterogeneity of the current studies in using TML or DL models to diagnose LSS, thereby providing more comprehensive information for further clinical application. METHODS This review was performed under the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines using articles extracted from PubMed, Embase databases, and Cochrane Library databases. Studies that evaluated DL or TML algorithms assessment value on diagnosing LSS were included, while those with duplicated or unavailable data were excluded. Quality Assessment of Diagnostic Accuracy Studies 2 was used to estimate the risk of bias in each study. The MIDAS module and the METAPROP module of Stata (StataCorp) were used for data synthesis and statistical analyses. RESULTS A total of 12 studies with 15,044 patients reported the assessment value of TML or DL models for diagnosing LSS. The risk of bias assessment yielded 4 studies with high risk of bias, 3 with unclear risk of bias, and 5 with completely low risk of bias. The pooled sensitivity and specificity were 0.84 (95% CI: 0.82-0.86; I2=99.06%) and 0.87 (95% CI 0.84-0.90; I2=98.7%), respectively. The diagnostic odds ratio was 36 (95% CI 26-49), the positive likelihood ratio (LR+) was 6.6 (95% CI 5.1-8.4), and the negative likelihood ratio (LR–) was 0.18 (95% CI 0.16-0.21). The summary receiver operating characteristic curves, the area under the curve of TML or DL models for diagnosing LSS of 0.92 (95% CI 0.89-0.94), indicating a high diagnostic value. CONCLUSIONS This systematic review and meta-analysis emphasize that despite the generally satisfactory diagnostic performance of artificial intelligence systems in the experimental stage for the diagnosis of LSS, none of them is reliable and practical enough to apply in real clinical practice. Further efforts, including optimization of model balance, widely accepted objective reference standards, multimodal strategy, large dataset for training and testing, external validation, and sufficient and scientific report, should be made to bridge the distance between current TML or DL models and real-life clinical applications in future studies. CLINICALTRIAL PROSPERO CRD42024566535; https://tinyurl.com/msx59x8k

  • Open Access

    A biomechanical study on proximal junctional kyphosis following long-segment posterior spinal fusion

    by Wen-Yi Zhu, Lei Zang, Jian Li, Li Guan, Yong Hai

    Posterior long-segment spinal fusion may lead to proximal junctional kyphosis (PJK). The present study sought to identify the appropriate fusion levels required in order to prevent PJK using finite element analysis. A finite element model was constructed based on the whole-spine computed tomography findings of a healthy adult. Nine commonly used posterior spinal fusion methods were selected. Stress on the annulus fibrosis fibers, the posterior ligamentous complex, and the vertebrae after various spinal fusions in the upright position were compared. This study was divided into two groups: non-fusion and fusion. In the former, the stress between the T10 and the upper thoracic vertebrae was higher. Comparing thoracic and lumbar segments in the fusion group, the peak stress values of the upper instrumented vertebrae (UIV) were mainly observed in T2 and L2 whilst those of the UIV+1 were observed in T10 and L2. After normalization, the peak stress values of the UIV and UIV+1 were located in T2 and L2. Similarly, the peak stress values of the annulus fibrosus at the upper adjacent level were on T10 and L2 after normalization. However, the peak stress values of the interspinal/supraspinal complex forces were concentrated on T11, T12, and L1 after normalization whilst the peak stress value of the pedicle screw was on T2. Controversy remains over the fusion of T10, and this study simulated testing conditions with gravitational loading only. However, further assessment is needed prior to reaching definitive conclusions.


  • Open Access

    Daam2 driven degradation of VHL promotes gliomagenesis

    by Wenyi Zhu, Saritha Krishna, Cristina Garcia, Chia-Ching John Lin, Bartley D Mitchell, Kenneth L Scott, Carrie A Mohila, Chad J Creighton, Seung-Hee Yoo, Hyun Kyoung Lee, et al.

    Von Hippel-Landau (VHL) protein is a potent tumor suppressor regulating numerous pathways that drive cancer, but mutations in VHL are restricted to limited subsets of malignancies. Here we identified a novel mechanism for VHL suppression in tumors that do not have inactivating mutations. Using developmental processes to uncover new pathways contributing to tumorigenesis, we found that Daam2 promotes glioma formation. Protein expression screening identified an inverse correlation between Daam2 and VHL expression across a host of cancers, including glioma. These in silico insights guided corroborating functional studies, which revealed that Daam2 promotes tumorigenesis by suppressing VHL expression. Furthermore, biochemical analyses demonstrate that Daam2 associates with VHL and facilitates its ubiquitination and degradation. Together, these studies are the first to define an upstream mechanism regulating VHL suppression in cancer and describe the role of Daam2 in tumorigenesis.