Lin Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lin Du has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Mark. G. Allen
University of Pennsylvania
4 shared publications - Andrew G. Richardson
Department of Neurosurgery, University of Pennsylvania, Philadelphia, USA
3 shared publications - Adam de la Zerda
Department of Structural Biology, Stanford University School of Medicine, Stanford University, Stanford, USA
2 shared publications - Andrew Gabros
Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
2 shared publications - Firooz Aflatouni
University of Pennsylvania
2 shared publications - Han Hao
Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA, USA
2 shared publications
Latest Publications
- Open Access
- 11 October 2023
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 9 (1) , 1-12
An implantable, wireless, battery-free system for tactile pressure sensing
The sense of touch is critical to dexterous use of the hands and thus an essential component of efforts to restore hand function after amputation or paralysis. Prosthetic systems have addressed this goal with wearable tactile sensors. However, such wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient’s own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive pressure sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop assessment, and testing in a primate hand. The sensor implanted in the fingertip accurately measured applied skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.
- 11 October 2023
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 9 (1) , 1-12
Open AccessAn implantable, wireless, battery-free system for tactile pressure sensing
The sense of touch is critical to dexterous use of the hands and thus an essential component of efforts to restore hand function after amputation or paralysis. Prosthetic systems have addressed this goal with wearable tactile sensors. However, such wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient’s own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive pressure sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop assessment, and testing in a primate hand. The sensor implanted in the fingertip accurately measured applied skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.
- Open Access
- 3 February 2023
- Published by Springer Nature in Research Square
An implantable wireless tactile sensing system
The sense of touch is critical to dexterous use of the hands and thus an essential component to efforts to restore hand function after amputation or paralysis. Prosthetic systems have focused on wearable tactile sensors. But wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient’s own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive force sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop testing, and ex vivo testing in a primate hand. The sensor implanted in the fingertip accurately measured skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.
- 3 February 2023
- Published by Springer Nature in Research Square
Open AccessAn implantable wireless tactile sensing system
The sense of touch is critical to dexterous use of the hands and thus an essential component to efforts to restore hand function after amputation or paralysis. Prosthetic systems have focused on wearable tactile sensors. But wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient’s own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive force sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop testing, and ex vivo testing in a primate hand. The sensor implanted in the fingertip accurately measured skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.
- Top Cited Papers
- 1 December 2022
- Published by Springer Nature in Nature Photonics
- Vol. 17 (1) , 89-95
Optical-resolution photoacoustic microscopy with a needle-shaped beam
Optical-resolution photoacoustic microscopy can visualize wavelength-dependent optical absorption at the cellular level. However, this technique suffers from a limited depth of field due to the tight focus of the optical excitation beam, making it challenging to acquire high-resolution images of samples with uneven surfaces or high-quality volumetric images without z scanning. To overcome this limitation, we propose needle-shaped beam photoacoustic microscopy, which can extend the depth of field to around a 28-fold Rayleigh length via customized diffractive optical elements. These diffractive optical elements generate a needle-shaped beam with a well-maintained beam diameter, a uniform axial intensity distribution and negligible sidelobes. The advantage of using needle-shaped beam photoacoustic microscopy is demonstrated via both histology-like imaging of fresh slide-free organs using a 266 nm laser and in vivo mouse-brain vasculature imaging using a 532 nm laser. This approach provides new perspectives for slide-free intraoperative pathological imaging and in vivo organ-level imaging.
- 1 December 2022
- Published by Springer Nature in Nature Photonics
- Vol. 17 (1) , 89-95
Top Cited PapersOptical-resolution photoacoustic microscopy with a needle-shaped beam
Optical-resolution photoacoustic microscopy can visualize wavelength-dependent optical absorption at the cellular level. However, this technique suffers from a limited depth of field due to the tight focus of the optical excitation beam, making it challenging to acquire high-resolution images of samples with uneven surfaces or high-quality volumetric images without z scanning. To overcome this limitation, we propose needle-shaped beam photoacoustic microscopy, which can extend the depth of field to around a 28-fold Rayleigh length via customized diffractive optical elements. These diffractive optical elements generate a needle-shaped beam with a well-maintained beam diameter, a uniform axial intensity distribution and negligible sidelobes. The advantage of using needle-shaped beam photoacoustic microscopy is demonstrated via both histology-like imaging of fresh slide-free organs using a 266 nm laser and in vivo mouse-brain vasculature imaging using a 532 nm laser. This approach provides new perspectives for slide-free intraoperative pathological imaging and in vivo organ-level imaging.
- 22 July 2022
- Published by Optica Publishing Group in Optica
- Vol. 9 (8) , 859-867
Flexible method for generating needle-shaped beams and its application in optical coherence tomography
Needle-shaped beams (NBs) featuring a long depth-of-focus (DOF) can drastically improve the resolution of microscopy systems. However, thus far, the implementation of a specific NB has been onerous due to the lack of a common, flexible generation method. Here we develop a spatially multiplexed phase pattern that creates many axially closely spaced foci as a universal platform for customizing various NBs, allowing flexible manipulations of beam length and diameter, uniform axial intensity, and sub-diffraction-limit beams. NBs designed via this method successfully extended the DOF of our optical coherence tomography (OCT) system. It revealed clear individual epidermal cells of the entire human epidermis, fine structures of human dermal-epidermal junction in a large depth range, and a high-resolution dynamic heartbeat of alive Drosophila larvae.
- 22 July 2022
- Published by Optica Publishing Group in Optica
- Vol. 9 (8) , 859-867
Flexible method for generating needle-shaped beams and its application in optical coherence tomography
Needle-shaped beams (NBs) featuring a long depth-of-focus (DOF) can drastically improve the resolution of microscopy systems. However, thus far, the implementation of a specific NB has been onerous due to the lack of a common, flexible generation method. Here we develop a spatially multiplexed phase pattern that creates many axially closely spaced foci as a universal platform for customizing various NBs, allowing flexible manipulations of beam length and diameter, uniform axial intensity, and sub-diffraction-limit beams. NBs designed via this method successfully extended the DOF of our optical coherence tomography (OCT) system. It revealed clear individual epidermal cells of the entire human epidermis, fine structures of human dermal-epidermal junction in a large depth range, and a high-resolution dynamic heartbeat of alive Drosophila larvae.
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 69 (6) , 2907-2920
A Wireless Artificial Mechanoreceptor in 180-nm CMOS
This article presents an implantable low-power wireless integrated system for tactile sensing applications. The reported application-specified integrated circuit (ASIC) uses a low-loss magnetic human body communication channel for both wireless power and data transfer. The chip is hybrid-integrated with an in-house fabricated MEMS capacitive force sensor to form an implantable artificial mechanoreceptor. An on-chip correlated double sampling capacitance to time converter (CTC) consumes 750 nW from a 1.2-V on-chip regulated supply, achieving a 2.0-fF resolution for an input capacitance of 14 pF and a FoM of 49 fJ/c-s while occupying an area of only 0.04 mm 2 . The CTC has a time-multiplexed mode to interface with four input capacitors. Wireless power management feedback is used to ensure robust operation in the presence of hand gesture changes and process–voltage–temperature variations. The on-chip data transmitter can operate in ON–OFF keying (OOK) or frequency-shift keying modulation formats, where it consumes only $7.8~\mu \text{W}$ in the OOK mode. The 1.62-mm 2 chip is fabricated in a standard 180-nm CMOS process and consumes $110.3~\mu \text{W}$ .
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 69 (6) , 2907-2920
A Wireless Artificial Mechanoreceptor in 180-nm CMOS
This article presents an implantable low-power wireless integrated system for tactile sensing applications. The reported application-specified integrated circuit (ASIC) uses a low-loss magnetic human body communication channel for both wireless power and data transfer. The chip is hybrid-integrated with an in-house fabricated MEMS capacitive force sensor to form an implantable artificial mechanoreceptor. An on-chip correlated double sampling capacitance to time converter (CTC) consumes 750 nW from a 1.2-V on-chip regulated supply, achieving a 2.0-fF resolution for an input capacitance of 14 pF and a FoM of 49 fJ/c-s while occupying an area of only 0.04 mm 2 . The CTC has a time-multiplexed mode to interface with four input capacitors. Wireless power management feedback is used to ensure robust operation in the presence of hand gesture changes and process–voltage–temperature variations. The on-chip data transmitter can operate in ON–OFF keying (OOK) or frequency-shift keying modulation formats, where it consumes only $7.8~\mu \text{W}$ in the OOK mode. The 1.62-mm 2 chip is fabricated in a standard 180-nm CMOS process and consumes $110.3~\mu \text{W}$ .
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (4) , 656-665
CMOS Compatible Hermetic Packages Based on Localized Fusion Bonding of Fused Silica
Hermetic packages compatible with complementary metal-oxide-semiconductor (CMOS) processes and capable of transmitting RF and optical energy are in high demand. A hermetic packaging process based on the localized fusion bonding of patterned and stacked fused silica wafers to encapsulate a CMOS chip has been successfully demonstrated. The process also allows for feedthroughs to be fabricated within the package for wired interconnection to encapsulated devices. A carbon dioxide laser is applied to achieve localized fusion bonding of the fused silica stack. Exploiting vector motion of the laser, simultaneous bonding and dicing is achieved within 2 s. The low thermal conductivity of fused silica thermally isolates the CMOS chip from the bond area. The heat diffusion during the process is examined both experimentally and using finite element analysis. The temperature falls to CMOS compatibility levels (under 400°C) within a distance of 660 μm from the bond line. The viability of the packaging process and the hermeticity of the package are simultaneously evaluated by encapsulating a commercial MEMS humidity sensor within the package and monitoring the internal package humidity as a function of time. The packaged sensor was placed in an external relative humidity environment of 85% at 24°C and the relative humidity change inside the package was measured over a time span of 300 days. A water vapor leakage rate less than 4.6 x 10⁻¹⁴ atm· cm³/s was observed. These preliminary results suggest that the hermeticity of the package can meet the criterion of implantation in human body for more than 70 years for a package with an inner volume of 0.0012 cm³. [2018-0280]
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (4) , 656-665
CMOS Compatible Hermetic Packages Based on Localized Fusion Bonding of Fused Silica
Hermetic packages compatible with complementary metal-oxide-semiconductor (CMOS) processes and capable of transmitting RF and optical energy are in high demand. A hermetic packaging process based on the localized fusion bonding of patterned and stacked fused silica wafers to encapsulate a CMOS chip has been successfully demonstrated. The process also allows for feedthroughs to be fabricated within the package for wired interconnection to encapsulated devices. A carbon dioxide laser is applied to achieve localized fusion bonding of the fused silica stack. Exploiting vector motion of the laser, simultaneous bonding and dicing is achieved within 2 s. The low thermal conductivity of fused silica thermally isolates the CMOS chip from the bond area. The heat diffusion during the process is examined both experimentally and using finite element analysis. The temperature falls to CMOS compatibility levels (under 400°C) within a distance of 660 μm from the bond line. The viability of the packaging process and the hermeticity of the package are simultaneously evaluated by encapsulating a commercial MEMS humidity sensor within the package and monitoring the internal package humidity as a function of time. The packaged sensor was placed in an external relative humidity environment of 85% at 24°C and the relative humidity change inside the package was measured over a time span of 300 days. A water vapor leakage rate less than 4.6 x 10⁻¹⁴ atm· cm³/s was observed. These preliminary results suggest that the hermeticity of the package can meet the criterion of implantation in human body for more than 70 years for a package with an inner volume of 0.0012 cm³. [2018-0280]
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (5) , 822-829
Electrical Interconnects Fabricated From Biodegradable Conductive Polymer Composites
This paper presents the development and characterization of biodegradable electrical interconnects for transient implantable medical devices. The interconnects comprised micropatterned biodegradable conductive polymer composites, which were developed using iron (Fe) microparticles as the conductive filler and polycaprolactone (PCL) as the insulating matrix. The electrical properties of the composites were investigated under various degradation conditions. Electrical percolation was observed at 17% Fe volume fraction, but higher volume fractions exhibited more stable electrical resistivity throughout the time course of physiological degradation. The electrical resistivity of 40%vf Fe-PCL composites increased tenfold in an emulated packaged environment under degradation. Biodegradable electrical interconnects based on 40%vf Fe-PCL composites were successfully micropatterned in daisy-chain structures, illustrating the process compatibility of Fe-PCL composites for interconnect applications. The electrical resistance of the packaged daisy-chain structures exhibited a reasonable increase under degradation. An electrical lifetime of over five days was also achieved. System integration with a commercial humidity sensor and analytical calculations supporting other application scenarios confirmed the feasibility of micropatterned Fe-PCL interconnects for use in implantable electrical systems.
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (5) , 822-829
Electrical Interconnects Fabricated From Biodegradable Conductive Polymer Composites
This paper presents the development and characterization of biodegradable electrical interconnects for transient implantable medical devices. The interconnects comprised micropatterned biodegradable conductive polymer composites, which were developed using iron (Fe) microparticles as the conductive filler and polycaprolactone (PCL) as the insulating matrix. The electrical properties of the composites were investigated under various degradation conditions. Electrical percolation was observed at 17% Fe volume fraction, but higher volume fractions exhibited more stable electrical resistivity throughout the time course of physiological degradation. The electrical resistivity of 40%vf Fe-PCL composites increased tenfold in an emulated packaged environment under degradation. Biodegradable electrical interconnects based on 40%vf Fe-PCL composites were successfully micropatterned in daisy-chain structures, illustrating the process compatibility of Fe-PCL composites for interconnect applications. The electrical resistance of the packaged daisy-chain structures exhibited a reasonable increase under degradation. An electrical lifetime of over five days was also achieved. System integration with a commercial humidity sensor and analytical calculations supporting other application scenarios confirmed the feasibility of micropatterned Fe-PCL interconnects for use in implantable electrical systems.