BZBoyu Zhang

Boyu Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Boyu Zhang has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Controlled crosslink cleavage and phase separation enable highly stretchable and strong 3D-printed hydrogel for soft robotics

    by Liangshen Zhao, Jianrong Cai, Qilin Qian, Shengming Zhang, Chenhao Wang, Ting Chen, Chaonan Xiao, Chunling Ren, Qingmei Zeng, Bingkun Bao, et al.

    Soft robots operate safely in delicate, confined environments and require materials that combine softness and large deformation in complex architectures. Digital light processing (DLP) 3D printing enables such structures, but rapid curing fixes networks with short strands, limiting extensibility of printed hydrogels. Here we report a controlled post-print decrosslinking strategy that decouples shape fixation from network maturation to yield highly stretchable, strong DLP-printed hydrogels. In this design, photo-triggered, base-cleavable coupling between o-nitrobenzyl acetal and (meth)acrylate groups establishes a dense network for printing and shape fixation. Subsequent alkaline cleavage restores chain mobility and lengthens network strands, while hydrophobic side-group modification induces phase-separated domains that enhance strength. The resulting hydrogels reach 1100% strain at break and 3.7 MPa tensile strength, combining high stretchability with high strength. This performance enables pneumatic actuators with 8-fold volumetric expansion and payload transport in confined fluidic environments. Our strategy provides a soft material platform for 3D-printed soft robotic systems requiring large, reversible deformation.

  • Open Access

    Bronchoscopy Robot with Enhanced Flexibility and Stability via Multi‐Segment Variable Stiffness Catheter

    by Shucong Yin, Bin Huang, Shiyuan Dong, Junhao Wang, Liangshen Zhao, Yang Yang, Bingkun Bao, Hongen Liao, Fang Chen, Tianqi Huang, et al.

    Bronchoscopy robots are pivotal for improving the accuracy and efficiency of early lung cancer diagnosis. However, the stiffness of existing systems is fixed, which limits the robot from accurately navigating and performing stable operations on distant peripheral nodules. This paper introduces a novel bronchoscopy robot equipped with a magnetic multi‐segment variable stiffness catheter, whose stiffness can be precisely adjusted in real time. The soft state of the catheter can enhance the flexibility of movement, while the rigid state can provide stable support. The catheter's slender profile and wirelessly magnetic steerability facilitate access to the distal terminal bronchi for examination. The catheter achieved a maximum bending angle of 49.07° in soft state and 1.11° in rigid state. By independently controlling the stiffness of each segment, the catheter could conform to various complex shapes. In vitro experiments showed that the bronchoscopy robot could reach deep branches of the lung and operate in conjunction with tools such as lasers. The results of the live pig experiment confirmed that the bronchoscopy robot could navigate to the bronchial target location for detection. By accessing distal bronchi unreachable by commercial systems, our robot offers a superior solution for early‐stage lung cancer bronchoscopy.

  • Hysteresis-Aware Neural Network Modeling and Whole-Body Reinforcement Learning Control of Soft Robots

    by Zongyuan Chen, Yan Xia, Jiayuan Liu, Jijia Liu, Wenhao Tang, Jiayu Chen, Feng Gao, Longfei Ma, Hongen Liao, Yu Wang, et al.

    Soft robots are inherently compliant and safe, making them suitable for human-interactive applications such as surgery. However, their nonlinear and hysteretic behavior, arising from the properties of soft materials, presents substantial challenges for accurate modeling and control. In this study, we present a soft robotic system and propose a hysteresis-aware whole-body neural network model that accurately captures and predicts the soft robot's whole-body motion, including its hysteretic behavior. Building upon the high-precision dynamic model, we construct a highly parallel simulation environment for soft robot control and apply an on-policy reinforcement learning algorithm to efficiently train whole-body motion control policies. The trained policy is deployed on the real soft robot to evaluate its control performance. Furthermore, we develop a soft robotic system for surgical applications and validate it through phantom-based laser ablation experiments. The results demonstrate that the hysteresis-aware modeling reduces the Mean Squared Error (MSE) by 86.07% compared with traditional modeling methods. The deployed control algorithm achieves a trajectory tracking error ranging from 0.147 to 0.307 mm on the real soft robot, highlighting its precision in real-world conditions. The proposed method also shows strong performance in phantom-based surgical experiments, and demonstrates its potential for complex scenarios, including future real-world clinical applications.


  • Origami and Zig-Zag Actuators for Adaptive Morphology in Soft Robotic Applications

    by Yang Yang, Kejin Zhu, Shaoyang Yan, Yuan Xie, Boyu Zhang, Yunquan Li

    Origami, with its advantages of reconfigurability and deployability, has been widely applied in soft robots. However, existing soft robot design using origami are often limited in functionality, therefore, it is essential to develop multifunctional soft robots with adaptive morphology to enhance their adaptability. In this study, we proposed a pneumatic actuator integrating origami actuator and zig-zag actuator (POZA). POZA can achieve unfolding, bending, and folding, each unit can be independently controlled, enabling multiple freely transformable shape morphing and controllable motion. We provided a detailed description of the design, modeling, and characterization of POZA. Based on POZA, we designed four robot prototypes including a robotic arm, a robotic gripper, a crawling robot, and a swimming robot for manipulation and locomotion to illustrate the versatility of the POZA across different aspects. The proposed actuator has the potential meet the evolving requirements for soft robots to adapt their morphology actively to accommodate to different tasks and changing environments.


  • Open Access

    A Soft‐Tip Hydraulically Steerable Catheter for Enhanced Flexibility and Safety in Vascular Interventions

    by Jingyi Kang, Ye Wang, Jiayuan Liu, Zhuhao Wang, Xuan Yang, Jie Wang, Jian Wu, Guochen Ning, Boyu Zhang, Hongen Liao

    Steerable catheters offer significant advantages over conventional catheters, including enhanced control, stability, and accessibility, which reduce operational complexity, fluoroscopy time, and radiation exposure, positioning them as a promising advancement for vascular interventional procedures. Herein, a novel steerable catheter is presented, featuring a hydraulically actuated, soft, steerable tip that allows for real‐time visualization in X‐ray imaging. To optimize performance, several silicone materials were evaluated for their mechanical properties, resulting in a soft tip design with a diameter of 2.6 mm. The tip incorporates an internal tool channel and supports a large bending angle of 180°. The tip demonstrates an average response time of 1.141 s (±0.750 s), a maximum output force of 0.145 N (±0.001 N), and a maximum radial expansion of 1.121 (±0.006). A steering kinematic model of the catheter tip is developed to simulate its movement. The catheter tip's real‐time shape and position information are obtained through intelligent segmentation and neighborhood‐based endpoint detection methods, assisting the surgeon during superselective procedures. The catheter's visibility and flexibility are validated in a live porcine model, demonstrating its potential for future use in interventional procedures.


  • Spring-reinforced pneumatic actuator and soft robotic applications

    by Boyu Zhang, Xiangming Gu, Jiayuan Liu, Jingyi Kang, Chengquan Hu, Hongen Liao

    Compared to rigid-structure robots, soft robots possess higher degrees of freedom and stronger environmental adaptability, which has aroused increasing attention in the robotic field. Among them, soft pneumatic robots have excellent performances in various practical applications. However, the nonlinearity and instability of pressure response of soft actuators caused by lateral expansion come to a great challenge. To address this problem, we proposed to embed a spring constraint layer around each single air chamber. Following the design concept, we obtained single-cavity and multi-DoF pneumatic actuators and evaluated their elongation and bending characteristics. Experimental results demonstrated that our proposed actuators have more linear pressure response as well as higher consistency. Eventually, through robotic applications, including soft robotic hand and gripper our proposed actuators could facilitate flexible manipulation and elaborate performance.


  • Open Access

    Biosensor with Microchannel for Broadband Dielectric Characterization of Nanoliter Cell Suspensions up to 110 GHz

    by Wen Sun, Jianhua Wang, Jin Chen, Xiwei Huang, Xin Rao, Jiangtao Su, Yuqiao Huang, Boyu Zhang, Lingling Sun

    Cell dielectric property measurement holds significant potential for application in cell detection and diagnosis due to its label-free and noninvasive nature. In this study, we developed a biosensor designed to measure the permittivity of liquid samples, particularly cell suspensions at the nanoliter scale, utilizing microwave and millimeter wave coplanar waveguides in conjunction with a microchannel. This biosensor facilitates the measurement of scattering parameters within a frequency domain ranging from 1 GHz to 110 GHz. The obtained scattering parameters are then converted into dielectric constants using specific algorithms. A cell capture structure within the microchannel ensures that cell suspensions remain stable within the measurement zone. The feasibility of this biosensor was confirmed by comparison with a commercial Keysight probe. We measured the dielectric constants of three different cell suspensions (HepG2, A549, MCF-7) using our biosensor. We also counted the number of cells captured in multiple measurements for each cell type and compared the corresponding changes in permittivity. The results indicated that the real part of the permittivity of HepG2 cells is 0.2–0.8 lower than that of the other two cell types. The difference between A549 and MCF-7 was relatively minor, only 0.2–0.4. The fluctuations in the dielectric spectrum caused by changes in cell numbers during measurements were smaller than the differences observed between different cell types. Thus, the sensor is suitable for measuring cell suspensions and can be utilized for label-free, noninvasive studies in identifying biological cell suspensions.


  • A Miniaturized Variable Stiffness Soft Manipulator With a Customizable LMPA Pattern

    by Chengquan Hu, Jiayuan Liu, Jiaqi Chen, Shangqi Dai, Jie Wang, Boyu Zhang, Hongen Liao

    Safe human-robot interaction and excellent motion flexibility ensure a wide range of potential applications for soft robots in industry and medicine. Although many efforts have been made to empower soft robots with variable stiffness, solutions for miniaturization, wide-range, and rapid-response stiffness have yet to be realized. To maintain the combination of motion flexibility and operation stability, in this work a soft variable stiffness manipulator with a diameter of 10.7 mm based on a low melting point alloy (LMPA) solution is proposed. Inspired by reinforced concrete structures, LMPA structures can be freely designed and optimized by a novel 2D to 3D fabrication method for the first time. The crossed pattern LMPA was selected as the variable stiffness skeleton of the manipulator through comparative experiments. Under hot and cold water circulation, the rigid-soft transition time is reduced to 10–15 seconds due to structure optimization. Tests have shown that the omnidirectional steering manipulator can easily be bent over $180^{\circ }$ with high repeatability (standard deviation of $1.37^{\circ }$ ) in the soft state and lock the shape at any bend angle with a stiffness of about 415.45 N/m in the rigid state. The rapid and wide variation in stiffness of the soft manipulator can be used as a small platform for minimally invasive surgical tools in confined spaces.


  • Laser Endoscopic Manipulator Using Spring-Reinforced Multi-DoF Soft Actuator

    by Boyu Zhang, Penghui Yang, Xiangming Gu, Hongen Liao

    The flexible manipulators and related robotic systems have been widely used in minimally invasive surgery (MIS) for enhancing the intraoperative inspection and surgical operation. Although a variety of flexible manipulators using different mechanisms have been developed, most of them are rigid mechanical structures or single function, which lack softness, robustness or in-situ diagnosis and surgical treatment. To enrich the flexibility and therapeutic function of manipulators, we developed a laser endoscopic manipulator with a soft bendable tip. The soft bendable tip is composed of a spring-reinforced soft actuator with multiple channels, which are designed for placing diagnosis and therapy probes to enrich the integrated diagnosis and therapeutic function. Pilot results show that the actuator can bend and elongate in the three-dimensional space and the spring-reinforced structure increases the linearity and consistency of the soft actuator. Experimental outcomes demonstrate that the proposed robotic system has extended bending capability and integrated diagnosis and therapeutic function. The multiple functions with surgical tools and laser fiber realize in-situ therapy. Therefore, it would be an enhancement for future clinical applications such as single-port laparoscopic surgery (SPL) or neurosurgery.


  • Design and Modularization of Multi-DoF Soft Robotic Actuators

    by Boyu Zhang, Chengquan Hu, Penghui Yang, Zhuxiu Liao, Hongen Liao

    Soft robotic technologies offer a promising solution for unconstructed applications due to their complete softness, robustness and flexibility. In this letter, we explore the design and modularization of the flexible pneumatic robotic actuators designed for applications in minimally invasive surgery or other constrained spaces. We first identify the basic multi-cavity structure and subsequently explore three basic morphologies of the multi-DoF actuator, which are differentiated by the shapes of their inner chambers. The corresponding fabrication methods are developed to create the standard fabrication processes for such complicated structures. Furthermore, we propose the modular concept and method of assembling these actuators into flexible robotic manipulators for different applications. Results show that the fabrication methods are suitable for the corresponding different chamber structures and are adaptive for fabricating multiple scales from the miniature size (diameter of 3.5 mm) to larger size. Detailed characterizations show that the multi-DoF actuators can freely adjust the heading direction in the three dimensional space. Additionally, application experiments show that the modular design achieves to rapidly assemble flexible robotic manipulators, which are potential in future applications that require closer inspection and manipulation.