Choon-Geun Moon
Choon-Geun Moon has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chang-Hyo Son
Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
3 shared publications - Jung-In Yoon
Department of Refrigeration and Air-conditioning Engineering, College of Engineering, Pukyong National University, Busan 48513, Republic of Korea
2 shared publications - Hyunkyung Lee
Carbon & Light Materials Application Group, Korea Institute of Industrial Technology, Bucheon 14449, Republic of Korea
1 shared publication - Joon-Hyuk Lee
Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
1 shared publication Kwang-Hwan Choi
1 shared publication- Min-Ju Jeon
Department of Refrigeration and Air-Conditioning Engineering, College of Engineering, Pukyong National University, 45, Yongso-ro, Nam-Gu, Busan 48513, Republic of Korea
1 shared publication
Latest Publications
- 31 October 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (5) , 86-92
Cooling Performance of Heat Pump with Interactive Electronic Expansion Valve
Heat pumps consist mainly of compressors, evaporators, condensers and expansion valves, and change the flow of refrigerant to allow cooling or heating in a single unit. The expansion valve used in the heat pump is mainly used with the electronic expansion valve for the conventional manufactured cooler, which flows in a single direction, requiring a separate bypass line and check valve, thereby reducing the performance of the freezer. Therefore, in this study, the cooling performance according to the opening step was analyzed using a interactive expansion valve for R-404A, which does not require a bypass line and a check valve during the design of the heat pump. The cooling performance coefficient for R-404A was 3.633 for thermostatic expansion valve, 3.795 for conventional electronic expansion valves and 3.851 for interactive electronic expansion valves. This is an improvement of 6.001% compared to the temperature formula and 1.476% over the conventional electronic system.
- 31 October 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (5) , 86-92
Cooling Performance of Heat Pump with Interactive Electronic Expansion Valve
Heat pumps consist mainly of compressors, evaporators, condensers and expansion valves, and change the flow of refrigerant to allow cooling or heating in a single unit. The expansion valve used in the heat pump is mainly used with the electronic expansion valve for the conventional manufactured cooler, which flows in a single direction, requiring a separate bypass line and check valve, thereby reducing the performance of the freezer. Therefore, in this study, the cooling performance according to the opening step was analyzed using a interactive expansion valve for R-404A, which does not require a bypass line and a check valve during the design of the heat pump. The cooling performance coefficient for R-404A was 3.633 for thermostatic expansion valve, 3.795 for conventional electronic expansion valves and 3.851 for interactive electronic expansion valves. This is an improvement of 6.001% compared to the temperature formula and 1.476% over the conventional electronic system.
- 30 April 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (2) , 5-11
Performance Analysis of the Cascade Refrigeration System using R744 with the low temperature cycle
This paper analyzes coefficient of performance (COP) and mass flow ratio with respect to several factors in the high temperature cycle of cascade refrigeration system such as degree of superheating and subcooling, temperature of condensing and evaporating, efficiency of the internal heat exchanger and compressor. Various refrigerants are used in the high temperature cycle, and R744 is only used in low temperature cycle. The results are summarized as follows: the COP increases with increasing degree of subcooling. The COP decreases with increasing degree of superheating except R22, R32 and R717. The COP decreases with increasing condensing temperature and increasing internal heat exchanger efficiency. The mass flow ratio increases with increasing condensing temperature of the high temperature cycle. The mass flow ratio decreases with increasing superheating, subcooling, internal heat exchanger and evaporating temperature. Nevertheless, the mass flow ratio has no change with increasing compressure efficiency.
- 30 April 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (2) , 5-11
Performance Analysis of the Cascade Refrigeration System using R744 with the low temperature cycle
This paper analyzes coefficient of performance (COP) and mass flow ratio with respect to several factors in the high temperature cycle of cascade refrigeration system such as degree of superheating and subcooling, temperature of condensing and evaporating, efficiency of the internal heat exchanger and compressor. Various refrigerants are used in the high temperature cycle, and R744 is only used in low temperature cycle. The results are summarized as follows: the COP increases with increasing degree of subcooling. The COP decreases with increasing degree of superheating except R22, R32 and R717. The COP decreases with increasing condensing temperature and increasing internal heat exchanger efficiency. The mass flow ratio increases with increasing condensing temperature of the high temperature cycle. The mass flow ratio decreases with increasing superheating, subcooling, internal heat exchanger and evaporating temperature. Nevertheless, the mass flow ratio has no change with increasing compressure efficiency.
- 30 April 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (2) , 112-117
Economic Analysis and Control Characteristics of Seawater Slurry Refrigeration System for Fishing Vessel
In this study, the economic feasibility of applying freshwater crushed ice and seawater slurry ice maker to ship were analyzed by using life cycle method and investment recovery period method. As the result of the economic analysis using the life cycle method, the ratio of each cost item to the total life cycle cost (ten years) of the seawater slurry ice-maker shows that the initial investment cost is over 50 %. In case of fishing vessel loading ice, it is sold at a low price of 40,000 won per ton. As the result of the economic analysis, the total life cycle cost is calculated as the criterion for producing ice suitable for five tons of ice load at one time sailing, seawater slurry ice-maker is about 11 million won less than fresh water crushed method. The life cycle cost is integrated and it is confirmed that the investment cost can be recovered after seven years and nine months when using slurry ice-maker. The use of seawater slurry ice contributes to the improvement of the quality of the fish, the distribution of seafood and the advancement of processing of the seafood.
- 30 April 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (2) , 112-117
Economic Analysis and Control Characteristics of Seawater Slurry Refrigeration System for Fishing Vessel
In this study, the economic feasibility of applying freshwater crushed ice and seawater slurry ice maker to ship were analyzed by using life cycle method and investment recovery period method. As the result of the economic analysis using the life cycle method, the ratio of each cost item to the total life cycle cost (ten years) of the seawater slurry ice-maker shows that the initial investment cost is over 50 %. In case of fishing vessel loading ice, it is sold at a low price of 40,000 won per ton. As the result of the economic analysis, the total life cycle cost is calculated as the criterion for producing ice suitable for five tons of ice load at one time sailing, seawater slurry ice-maker is about 11 million won less than fresh water crushed method. The life cycle cost is integrated and it is confirmed that the investment cost can be recovered after seven years and nine months when using slurry ice-maker. The use of seawater slurry ice contributes to the improvement of the quality of the fish, the distribution of seafood and the advancement of processing of the seafood.
- 30 April 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (2) , 56-65
Field Control Test of Seawater Slush Ice Refrigeration System with Double-tube Evaporators
In this study, the basic field test of the ice-making machine and the cooling effect of the fish body were analyzed. The main results obtained in this study are summarized as follows. It was confirmed that the operation condition of the seawater slurry ice-maker was stable within the operation range. Evaporation pressure of ice machine was 2.1 kg/cm², inlet water temperature was 16.5℃, inlet water flow was 5 LPM, and seawater slurry ice of outlet IPF 20% was 7,200 kg/day. The ice-maker was able to obtain seawater slurry ice at a desired temperature within six minutes of operation. Seawater slurry ice was able to maintain the temperature of the fish body at the lowest temperature in the fish body cooling. Cooling speed of the fish body at the initial stage of cooling is expected to be effective in maintaining the fish body line by lowering the fish body temperature in the order of seawater slurry ice, freshwater ice, and cold water. The experimental results show that the operation characteristics of the ice-maker can be grasped by the demonstration test of the slurry type seawater ice-maker using the scraper type double-tube evaporator and the cooling effect of the seawater slurry ice can be confirmed.
- 30 April 2019
- Published by The Korea Society for Power System Engineering in Journal of Power System Engineering
- Vol. 23 (2) , 56-65
Field Control Test of Seawater Slush Ice Refrigeration System with Double-tube Evaporators
In this study, the basic field test of the ice-making machine and the cooling effect of the fish body were analyzed. The main results obtained in this study are summarized as follows. It was confirmed that the operation condition of the seawater slurry ice-maker was stable within the operation range. Evaporation pressure of ice machine was 2.1 kg/cm², inlet water temperature was 16.5℃, inlet water flow was 5 LPM, and seawater slurry ice of outlet IPF 20% was 7,200 kg/day. The ice-maker was able to obtain seawater slurry ice at a desired temperature within six minutes of operation. Seawater slurry ice was able to maintain the temperature of the fish body at the lowest temperature in the fish body cooling. Cooling speed of the fish body at the initial stage of cooling is expected to be effective in maintaining the fish body line by lowering the fish body temperature in the order of seawater slurry ice, freshwater ice, and cold water. The experimental results show that the operation characteristics of the ice-maker can be grasped by the demonstration test of the slurry type seawater ice-maker using the scraper type double-tube evaporator and the cooling effect of the seawater slurry ice can be confirmed.
- 31 January 2018
- Published by Journal of Advanced Marine Engineering and Technology in Journal of Advanced Marine Engineering and Technology
- Vol. 42 (1) , 10-15
Experimental study on the characteristics of a sherbet type seawater ice maker using scraper
어획물의 보관, 유통 과정에서 해수를 원수로 하는 샤베트형 얼음의 이용은 어획물의 선도 유지와 품질 면에서 좋은 방식으로 평가되고 있다. 하지만, 국내의 보관 및 유통 과정에서는 90% 이상이 담수 각 빙을 사용하며 이에 따라 품질과 신선도 측면에서 마이너스 효과를 보이고 있다. 본 연구에서는 소용량(0.55 Ton/day) 스크래퍼식 제빙기를 대상으로 해수의 입구 온도와 유량, 스크래퍼 회전수, 냉매의 증발온도, 염분 농도를 변화시켜가며 실험을 실시하여 샤베트형 해수빙의 형태와 제빙량, 빙충전율(IPF)을 알아보았으며, 그 결과는 다음과 같다. (1) 생성된 샤베트형 해수빙은 흰 색의 유동성을 가진 유체로, 얼음 입자의 크기는 직경 0.2 mm ~ 0.3 mm로 측정되었다. (2) 해수의 입구 온도가 낮을수록, 유량이 적을수록 IPF는 증가하며, 표준 조건에서 제빙량은 0.55 Ton/day를 보였다. (3) 스크래퍼 회전수가 증가할수록 IPF는 증가하며 해수의 염분 농도에 따른 IPF 변화는 미미하다. (4) 냉매의 증발온도가 낮아질수록 IPF는 증가하는 경향을 보인다. 이러한 결과는 샤베트형 해수 제빙장치 설계를 위한 중요한 자료가 되리라 판단된다.
- 31 January 2018
- Published by Journal of Advanced Marine Engineering and Technology in Journal of Advanced Marine Engineering and Technology
- Vol. 42 (1) , 10-15
Experimental study on the characteristics of a sherbet type seawater ice maker using scraper
어획물의 보관, 유통 과정에서 해수를 원수로 하는 샤베트형 얼음의 이용은 어획물의 선도 유지와 품질 면에서 좋은 방식으로 평가되고 있다. 하지만, 국내의 보관 및 유통 과정에서는 90% 이상이 담수 각 빙을 사용하며 이에 따라 품질과 신선도 측면에서 마이너스 효과를 보이고 있다. 본 연구에서는 소용량(0.55 Ton/day) 스크래퍼식 제빙기를 대상으로 해수의 입구 온도와 유량, 스크래퍼 회전수, 냉매의 증발온도, 염분 농도를 변화시켜가며 실험을 실시하여 샤베트형 해수빙의 형태와 제빙량, 빙충전율(IPF)을 알아보았으며, 그 결과는 다음과 같다. (1) 생성된 샤베트형 해수빙은 흰 색의 유동성을 가진 유체로, 얼음 입자의 크기는 직경 0.2 mm ~ 0.3 mm로 측정되었다. (2) 해수의 입구 온도가 낮을수록, 유량이 적을수록 IPF는 증가하며, 표준 조건에서 제빙량은 0.55 Ton/day를 보였다. (3) 스크래퍼 회전수가 증가할수록 IPF는 증가하며 해수의 염분 농도에 따른 IPF 변화는 미미하다. (4) 냉매의 증발온도가 낮아질수록 IPF는 증가하는 경향을 보인다. 이러한 결과는 샤베트형 해수 제빙장치 설계를 위한 중요한 자료가 되리라 판단된다.