Dennis Kleimaier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dennis Kleimaier has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Lothar R. Schad
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Heidelberg Germany
3 shared publicationsCordula Nies
Institute of Functional Interfaces, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publicationsEric Gottwald
Institute of Functional Interfaces, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications- Lothar R. Schad
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Mannheim Germany
2 shared publications Matthias Malzacher
Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany
2 shared publications- Michaela A. U. Hoesl
Computer Assisted Clinical Medicine, Heidelberg University, 68167 Mannheim, Germany
2 shared publications
Latest Publications
- Open Access
- 23 January 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (5) , e5106
Comparison of triple quantum (TQ) TPPI and inversion recovery TQ TPPI pulse sequences at 9.4 and 21.1 T
Purpose: Both sodium T1 triple quantum (TQ) signal and T1 relaxation pathways have a unique sensitivity to the sodium molecular environment. In this study an inversion recovery time proportional phase increment (IRTQTPPI) pulse sequence was investigated for simultaneous and reliable quantification of sodium TQ signal and bi‐exponential T1 relaxation times.Methods: The IRTQTPPI sequence combines inversion recovery TQ filtering and time proportional phase increment. The reliable and reproducible results were achieved by the pulse sequence optimized in three ways: (1) optimization of the nonlinear fit for the determination of both T1‐TQ signal and T1 relaxation times; (2) suppression of unwanted signals by assessment of four different phase cycles; (3) nonlinear sampling during evolution time for optimal scan time without any compromises in fit accuracy. The relaxation times T1 and T2 and the TQ signals from IRTQTPPI and TQTPPI were compared between 9.4 and 21.1 T. The motional environment of the sodium nuclei was evaluated by calculation of correlation times and nuclear quadrupole interaction strengths.Results: Reliable measurements of the T1‐TQ signals and T1 bi‐exponential relaxation times were demonstrated. The fit parameters for all four phase cycles were in good agreement with one another, with a negligible influence of unwanted signals. The agar samples yielded normalized T1‐TQ signals from 3% to 16% relative to single quantum (SQ) signals at magnetic fields of both 9.4 and 21.1 T. In comparison, the normalized T2‐TQ signal was in the range 15%–35%. The TQ/SQ signal ratio was decreased at 21.1 T as compared with 9.4 T for both T1 and T2 relaxation pathways. The bi‐exponential T1 relaxation time separation ranged from 15 to 18 ms at 9.4 T and 15 to 21 ms at 21.1 T. The T2 relaxation time separation was larger, ranging from 28 to 35 ms at 9.4 T and 37 to 40 ms at 21.1 T.Conclusion: The IRTQTPPI sequence, while providing a less intensive TQ signal than TQTPPI, allows a simultaneous and reliable quantification of both the T1‐TQ signal and T1 relaxation times. The unique sensitivities of the T1 and T2 relaxation pathways to different types of molecular motion provide a deeper understanding of the sodium MR environment.
- 23 January 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (5) , e5106
Open AccessComparison of triple quantum (TQ) TPPI and inversion recovery TQ TPPI pulse sequences at 9.4 and 21.1 T
Purpose: Both sodium T1 triple quantum (TQ) signal and T1 relaxation pathways have a unique sensitivity to the sodium molecular environment. In this study an inversion recovery time proportional phase increment (IRTQTPPI) pulse sequence was investigated for simultaneous and reliable quantification of sodium TQ signal and bi‐exponential T1 relaxation times.Methods: The IRTQTPPI sequence combines inversion recovery TQ filtering and time proportional phase increment. The reliable and reproducible results were achieved by the pulse sequence optimized in three ways: (1) optimization of the nonlinear fit for the determination of both T1‐TQ signal and T1 relaxation times; (2) suppression of unwanted signals by assessment of four different phase cycles; (3) nonlinear sampling during evolution time for optimal scan time without any compromises in fit accuracy. The relaxation times T1 and T2 and the TQ signals from IRTQTPPI and TQTPPI were compared between 9.4 and 21.1 T. The motional environment of the sodium nuclei was evaluated by calculation of correlation times and nuclear quadrupole interaction strengths.Results: Reliable measurements of the T1‐TQ signals and T1 bi‐exponential relaxation times were demonstrated. The fit parameters for all four phase cycles were in good agreement with one another, with a negligible influence of unwanted signals. The agar samples yielded normalized T1‐TQ signals from 3% to 16% relative to single quantum (SQ) signals at magnetic fields of both 9.4 and 21.1 T. In comparison, the normalized T2‐TQ signal was in the range 15%–35%. The TQ/SQ signal ratio was decreased at 21.1 T as compared with 9.4 T for both T1 and T2 relaxation pathways. The bi‐exponential T1 relaxation time separation ranged from 15 to 18 ms at 9.4 T and 15 to 21 ms at 21.1 T. The T2 relaxation time separation was larger, ranging from 28 to 35 ms at 9.4 T and 37 to 40 ms at 21.1 T.Conclusion: The IRTQTPPI sequence, while providing a less intensive TQ signal than TQTPPI, allows a simultaneous and reliable quantification of both the T1‐TQ signal and T1 relaxation times. The unique sensitivities of the T1 and T2 relaxation pathways to different types of molecular motion provide a deeper understanding of the sodium MR environment.
- Open Access
Intracellular Sodium Changes in Cancer Cells Using a Microcavity Array-Based Bioreactor System and Sodium Triple-Quantum MR Signal
The sodium triple-quantum (TQ) magnetic resonance (MR) signal created by interactions of sodium ions with macromolecules has been demonstrated to be a valuable biomarker for cell viability. The aim of this study was to monitor a cellular response using the sodium TQ signal during inhibition of Na/K-ATPase in living cancer cells (HepG2). The cells were dynamically investigated after exposure to 1 mM ouabain or K+-free medium for 60 min using an MR-compatible bioreactor system. An improved TQ time proportional phase incrementation (TQTPPI) pulse sequence with almost four times TQ signal-to-noise ratio (SNR) gain allowed for conducting experiments with 12–14 × 106 cells using a 9.4 T MR scanner. During cell intervention experiments, the sodium TQ signal increased to 138.9 ± 4.1% and 183.4 ± 8.9% for 1 mM ouabain (n = 3) and K+-free medium (n = 3), respectively. During reperfusion with normal medium, the sodium TQ signal further increased to 169.2 ± 5.3% for the ouabain experiment, while it recovered to 128.5 ± 6.8% for the K+-free experiment. These sodium TQ signal increases agree with an influx of sodium ions during Na/K-ATPase inhibition and hence a reduced cell viability. The improved TQ signal detection combined with this MR-compatible bioreactor system provides a capability to investigate the cellular response of a variety of cells using the sodium TQ MR signal.
Open AccessIntracellular Sodium Changes in Cancer Cells Using a Microcavity Array-Based Bioreactor System and Sodium Triple-Quantum MR Signal
The sodium triple-quantum (TQ) magnetic resonance (MR) signal created by interactions of sodium ions with macromolecules has been demonstrated to be a valuable biomarker for cell viability. The aim of this study was to monitor a cellular response using the sodium TQ signal during inhibition of Na/K-ATPase in living cancer cells (HepG2). The cells were dynamically investigated after exposure to 1 mM ouabain or K+-free medium for 60 min using an MR-compatible bioreactor system. An improved TQ time proportional phase incrementation (TQTPPI) pulse sequence with almost four times TQ signal-to-noise ratio (SNR) gain allowed for conducting experiments with 12–14 × 106 cells using a 9.4 T MR scanner. During cell intervention experiments, the sodium TQ signal increased to 138.9 ± 4.1% and 183.4 ± 8.9% for 1 mM ouabain (n = 3) and K+-free medium (n = 3), respectively. During reperfusion with normal medium, the sodium TQ signal further increased to 169.2 ± 5.3% for the ouabain experiment, while it recovered to 128.5 ± 6.8% for the K+-free experiment. These sodium TQ signal increases agree with an influx of sodium ions during Na/K-ATPase inhibition and hence a reduced cell viability. The improved TQ signal detection combined with this MR-compatible bioreactor system provides a capability to investigate the cellular response of a variety of cells using the sodium TQ MR signal.
- Open Access
- 12 July 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (10) , e4367
Protein conformational changes affect the sodium triple‐quantum MR signal
The aim of this study was to investigate possible sodium triple‐quantum (TQ) signal dependence on pH variation and protein unfolding which may happen in vivo. The model system, composed of bovine serum albumin (BSA), was investigated over a wide pH range of 0.70 to 13.05 and during urea‐induced unfolding. In both experimental series, the sodium and BSA concentration were kept constant so that TQ signal changes solely arose from an environmental change. The experiments were performed using unique potential to detect weak TQ signals by implementing a TQ time proportional phase increment pulse sequence. At a pH of 0.70, in which case the effect of the negatively charged groups was minimized, the minimum TQ percentage relative to single‐quantum of 1.34% ± 0.05% was found. An increase of the pH up to 13.05 resulted in an increase of the sodium TQ signal by 225%. Urea‐induced unfolding of BSA, without changes in pH, led to a smaller increase in the sodium TQ signal of up to 40%. The state of BSA unfolding was verified by fluorescence microscopy. Results of both experiments were well fitted by sigmoid functions. Both TQ signal increases were in agreement with an increase of the availability of negatively charged groups. The results point to vital contributions of the biochemical environment to the TQ MR signals. The sodium TQ signal in vivo could be a valuable biomarker of cell viability, and therefore possible effects of pH and protein unfolding need to be considered for a proper interpretation of changes in sodium TQ signals.
- 12 July 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (10) , e4367
Open AccessProtein conformational changes affect the sodium triple‐quantum MR signal
The aim of this study was to investigate possible sodium triple‐quantum (TQ) signal dependence on pH variation and protein unfolding which may happen in vivo. The model system, composed of bovine serum albumin (BSA), was investigated over a wide pH range of 0.70 to 13.05 and during urea‐induced unfolding. In both experimental series, the sodium and BSA concentration were kept constant so that TQ signal changes solely arose from an environmental change. The experiments were performed using unique potential to detect weak TQ signals by implementing a TQ time proportional phase increment pulse sequence. At a pH of 0.70, in which case the effect of the negatively charged groups was minimized, the minimum TQ percentage relative to single‐quantum of 1.34% ± 0.05% was found. An increase of the pH up to 13.05 resulted in an increase of the sodium TQ signal by 225%. Urea‐induced unfolding of BSA, without changes in pH, led to a smaller increase in the sodium TQ signal of up to 40%. The state of BSA unfolding was verified by fluorescence microscopy. Results of both experiments were well fitted by sigmoid functions. Both TQ signal increases were in agreement with an increase of the availability of negatively charged groups. The results point to vital contributions of the biochemical environment to the TQ MR signals. The sodium TQ signal in vivo could be a valuable biomarker of cell viability, and therefore possible effects of pH and protein unfolding need to be considered for a proper interpretation of changes in sodium TQ signals.
- Open Access
- 6 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
The cellular heat shock response monitored by chemical exchange saturation transfer MRI
CEST-MRI of the rNOE signal has been demonstrated in vitro to be closely linked to the protein conformational state. As the detectability of denaturation and aggregation processes on a physiologically relevant scale in living organisms has yet to be verified, the aim of this study was to perform heat-shock experiments with living cells to monitor the cellular heat-shock response of the rNOE CEST signal. Cancer cells (HepG2) were dynamically investigated after a mild, non-lethal heat-shock of 42 °C for 20 min using an MR-compatible bioreactor system at 9.4 T. Reliable and fast high-resolution CEST imaging was realized by a relaxation-compensated 2-point contrast metric. After the heat-shock, a substantial decrease of the rNOE CEST signal by 8.0 ± 0.4% followed by a steady signal recovery within a time of 99.1 ± 1.3 min was observed in two independent trials. This continuous signal recovery is in coherence with chaperone-induced refolding of heat-shock induced protein aggregates. We demonstrated that protein denaturation processes influence the CEST-MRI signal on a physiologically relevant scale. Thus, the protein folding state is, along with concentration changes, a relevant physiological parameter for the interpretation of CEST signal changes in diseases that are associated with pathological changes in protein expression, like cancer and neurodegenerative diseases.
- 6 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessThe cellular heat shock response monitored by chemical exchange saturation transfer MRI
CEST-MRI of the rNOE signal has been demonstrated in vitro to be closely linked to the protein conformational state. As the detectability of denaturation and aggregation processes on a physiologically relevant scale in living organisms has yet to be verified, the aim of this study was to perform heat-shock experiments with living cells to monitor the cellular heat-shock response of the rNOE CEST signal. Cancer cells (HepG2) were dynamically investigated after a mild, non-lethal heat-shock of 42 °C for 20 min using an MR-compatible bioreactor system at 9.4 T. Reliable and fast high-resolution CEST imaging was realized by a relaxation-compensated 2-point contrast metric. After the heat-shock, a substantial decrease of the rNOE CEST signal by 8.0 ± 0.4% followed by a steady signal recovery within a time of 99.1 ± 1.3 min was observed in two independent trials. This continuous signal recovery is in coherence with chaperone-induced refolding of heat-shock induced protein aggregates. We demonstrated that protein denaturation processes influence the CEST-MRI signal on a physiologically relevant scale. Thus, the protein folding state is, along with concentration changes, a relevant physiological parameter for the interpretation of CEST signal changes in diseases that are associated with pathological changes in protein expression, like cancer and neurodegenerative diseases.
- 17 May 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (2) , 355-376
X‐nuclei imaging: Current state, technical challenges, and future directions
1H imaging is concerned with contrast generation among anatomically distinct soft tissues. X‐nuclei imaging, on the other hand, aims to reveal the underlying changes in the physiological processes on a cellular level. Advanced clinical MR hardware systems improved1H image quality and simultaneously enabled X‐nuclei imaging. Adaptation of1H methods and optimization of both sequence design and postprocessing protocols launched X‐nuclei imaging past feasibility studies and into clinical studies. This review outlines the current state of X‐nuclei MRI, with the focus on23Na,35Cl,39K, and17O. Currently, various aspects of technical challenges limit the possibilities of clinical X‐nuclei MRI applications. To address these challenges, quintessential physical and technical concepts behind different applications are presented, and the advantages and drawbacks are delineated. The working process for methods such as quantification and multiquantum imaging is shown step‐by‐step. Clinical examples are provided to underline the potential value of X‐nuclei imaging in multifaceted areas of application. In conclusion, the scope of the latest technical advance is outlined, and suggestions to overcome the most fundamental hurdles on the way into clinical routine by leveraging the full potential of X‐nuclei imaging are presented.Level of Evidence:1Technical Efficacy Stage:3J. Magn. Reson. Imaging 2020;51:355–376.
- 17 May 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (2) , 355-376
X‐nuclei imaging: Current state, technical challenges, and future directions
1H imaging is concerned with contrast generation among anatomically distinct soft tissues. X‐nuclei imaging, on the other hand, aims to reveal the underlying changes in the physiological processes on a cellular level. Advanced clinical MR hardware systems improved1H image quality and simultaneously enabled X‐nuclei imaging. Adaptation of1H methods and optimization of both sequence design and postprocessing protocols launched X‐nuclei imaging past feasibility studies and into clinical studies. This review outlines the current state of X‐nuclei MRI, with the focus on23Na,35Cl,39K, and17O. Currently, various aspects of technical challenges limit the possibilities of clinical X‐nuclei MRI applications. To address these challenges, quintessential physical and technical concepts behind different applications are presented, and the advantages and drawbacks are delineated. The working process for methods such as quantification and multiquantum imaging is shown step‐by‐step. Clinical examples are provided to underline the potential value of X‐nuclei imaging in multifaceted areas of application. In conclusion, the scope of the latest technical advance is outlined, and suggestions to overcome the most fundamental hurdles on the way into clinical routine by leveraging the full potential of X‐nuclei imaging are presented.Level of Evidence:1Technical Efficacy Stage:3J. Magn. Reson. Imaging 2020;51:355–376.
- 25 January 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (2) , 435-444
23Na Triple‐quantum signal of in vitro human liver cells, liposomes, and nanoparticles: Cell viability assessment vs. separation of intra‐ and extracellular signal
Background: Triple‐quantum (TQ) filtered sequences have become more popular in sodium MR due to the increased usage of scanners with field strengths exceeding 3T. Disagreement as to whether TQ signal can provide separation of intra‐ and extracellular compartments persists.Purpose: To provide insight into TQ signal behavior on a cellular level.Study Type: Prospective.Phantom/Specimen: Cell‐phantoms in the form of liposomes, encapsulated 0 mM, 145 mM, 154 mM Na+ in a double‐lipid membrane similar to cells. Poly(lactic‐co‐glycolic acid) nanoparticles encapsulated 154 mM Na+ within a single‐layer membrane structure. Two microcavity chips with each 6 × 106 human HEP G2 liver cells were measured in an MR‐compatible bioreactor.Field Strength/Sequence: Spectroscopic TQ sequence with time proportional phase‐increments at 9.4T.Assessment: The TQ signal of viable, dead cells, and cell‐phantoms was assessed by a fit in the time domain and by the amplitude in the frequency domain.Statistical Tests: The noise variance (σ) was evaluated to express the deviation of the measured TQ signal amplitude from noise.Results: TQ signal >20σ was found for liposomes encapsulating sodium ions. Liposomal encapsulation of 0 mM Na+ and 154 mM Na+ encapsulation in the nanoparticles resulted in 9σ TQ signal. Compared with TQ signal under normal perfusion, a 56% lower TQ signal of was observed (25σ) during perfusion stop. TQ signal returned to 92% of the initial signal after reperfusion.Data Conclusion: Our measurements indicate that TQ signal in liposomes was observed due to the trapping of ions within the double‐lipid membrane rather than from the intraliposomal space. Transfer to the cell results suggests that TQ signal was observed from motion restriction equivalent to trapping.Level of Evidence: 1Technical Efficacy: Stage 3J. Magn. Reson. Imaging 2019;50:435–444.
- 25 January 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (2) , 435-444
23Na Triple‐quantum signal of in vitro human liver cells, liposomes, and nanoparticles: Cell viability assessment vs. separation of intra‐ and extracellular signal
Background: Triple‐quantum (TQ) filtered sequences have become more popular in sodium MR due to the increased usage of scanners with field strengths exceeding 3T. Disagreement as to whether TQ signal can provide separation of intra‐ and extracellular compartments persists.Purpose: To provide insight into TQ signal behavior on a cellular level.Study Type: Prospective.Phantom/Specimen: Cell‐phantoms in the form of liposomes, encapsulated 0 mM, 145 mM, 154 mM Na+ in a double‐lipid membrane similar to cells. Poly(lactic‐co‐glycolic acid) nanoparticles encapsulated 154 mM Na+ within a single‐layer membrane structure. Two microcavity chips with each 6 × 106 human HEP G2 liver cells were measured in an MR‐compatible bioreactor.Field Strength/Sequence: Spectroscopic TQ sequence with time proportional phase‐increments at 9.4T.Assessment: The TQ signal of viable, dead cells, and cell‐phantoms was assessed by a fit in the time domain and by the amplitude in the frequency domain.Statistical Tests: The noise variance (σ) was evaluated to express the deviation of the measured TQ signal amplitude from noise.Results: TQ signal >20σ was found for liposomes encapsulating sodium ions. Liposomal encapsulation of 0 mM Na+ and 154 mM Na+ encapsulation in the nanoparticles resulted in 9σ TQ signal. Compared with TQ signal under normal perfusion, a 56% lower TQ signal of was observed (25σ) during perfusion stop. TQ signal returned to 92% of the initial signal after reperfusion.Data Conclusion: Our measurements indicate that TQ signal in liposomes was observed due to the trapping of ions within the double‐lipid membrane rather than from the intraliposomal space. Transfer to the cell results suggests that TQ signal was observed from motion restriction equivalent to trapping.Level of Evidence: 1Technical Efficacy: Stage 3J. Magn. Reson. Imaging 2019;50:435–444.