Cheng Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cheng Guo has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Bo Chen
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Guanbin Gao
Kunming University of Science and Technology
2 shared publications - Jianbo Dai
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Jun Zhao
College of Transportation, Shandong University of Science and Technology, Qingdao, China
2 shared publications - Linzhen Zhong
Faculty of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Xuanming Yang
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications
Latest Publications
- Open Access
A Novel Method for Ferroresonance Fault Identification Based on Markov Transition Field and Three-Branch Gaussian Clustering
Existing ferroresonance fault identification methods often suffer from high misclassification rates, strong threshold dependency, and insufficient noise resistance. To bridge this gap, we propose a novel ferroresonance fault recognition method based on the Markov transition field (MTF) and three-branch Gaussian clustering (TBGC). Firstly, a symplectic geometric algorithm is employed to denoise the resonance feature signal, extract effective dominant modes, and reshape the series. Secondly, the reshaped feature series is converted into a Pixel matrix image employing the MTF. Subsequently, the gray-level co-occurrence matrix (GLCM) is utilized to extract the two-dimensional texture features of MTF images corresponding to different resonance types and construct corresponding TBGC models. Finally, the overvoltage sequence to be recognized is input into the TBGC model after feature extraction, and accurate discrimination of ferroresonance types is achieved based on cosine similarity. The analysis of fault recording data indicates that this method achieves 100% discrimination accuracy in eight test cases, surpassing the comparative method (maximum accuracy of 62.5%) by 37.5%, thereby validating its effectiveness and accuracy in ferroresonance identification.
Open AccessA Novel Method for Ferroresonance Fault Identification Based on Markov Transition Field and Three-Branch Gaussian Clustering
Existing ferroresonance fault identification methods often suffer from high misclassification rates, strong threshold dependency, and insufficient noise resistance. To bridge this gap, we propose a novel ferroresonance fault recognition method based on the Markov transition field (MTF) and three-branch Gaussian clustering (TBGC). Firstly, a symplectic geometric algorithm is employed to denoise the resonance feature signal, extract effective dominant modes, and reshape the series. Secondly, the reshaped feature series is converted into a Pixel matrix image employing the MTF. Subsequently, the gray-level co-occurrence matrix (GLCM) is utilized to extract the two-dimensional texture features of MTF images corresponding to different resonance types and construct corresponding TBGC models. Finally, the overvoltage sequence to be recognized is input into the TBGC model after feature extraction, and accurate discrimination of ferroresonance types is achieved based on cosine similarity. The analysis of fault recording data indicates that this method achieves 100% discrimination accuracy in eight test cases, surpassing the comparative method (maximum accuracy of 62.5%) by 37.5%, thereby validating its effectiveness and accuracy in ferroresonance identification.
- Open Access
A High-Ratio Renewable-Energy Power System Time–Frequency Domain-Cooperative Harmonic Detection Method Based on Enhanced Variational Modal Decomposition and the Prony Algorithm
Accurate identification of harmonic components is a prerequisite for addressing resonance risks in new energy power stations. Traditional Variational Modal decomposition (VMD) is susceptible to the influence of the modal decomposition order K and the penalty factor α when decomposing harmonic signals. This paper proposes an adaptive parameter selection method for VMD based on an improved Triangular Topology Aggregation Optimization (TTAO) algorithm. Firstly, the pre-set parameters of variational modal decomposition—modal order K and penalty factor α—exhibit strong coupling. Conventional optimization algorithms cannot effectively coordinate adjustments to both parameters. This paper employs an enhanced TTAO algorithm, whose triangular topology unit structure and dual aggregation mechanism enable simultaneous adjustment of modal order K and penalty factor α, effectively resolving their coupled optimization challenge. Using minimum envelope entropy as the fitness function, the algorithm obtains an optimized parameter combination for VMD to decompose the signal. Subsequently, dominant modal components are selected based on Pearson’s correlation coefficients for reconstruction, with harmonic parameters precisely identified using the Prony algorithm. Simulation results demonstrate that under a 20 dB noise environment, the proposed method achieves a signal-to-noise ratio (SNR) of 25.6952 for steady-state harmonics, with a root mean square error (RMSE) of 0.4889. The mean errors for frequency and amplitude identification are 0.055% and 3.085%, respectively, significantly outperforming methods such as PSO-VMD and EMD. Moreover, the runtime of our model is markedly shorter than that of the PSO-VMD algorithm, effectively resolving the symmetric trade-off between recognition accuracy and runtime inherent in variational modal decomposition.
Open AccessA High-Ratio Renewable-Energy Power System Time–Frequency Domain-Cooperative Harmonic Detection Method Based on Enhanced Variational Modal Decomposition and the Prony Algorithm
Accurate identification of harmonic components is a prerequisite for addressing resonance risks in new energy power stations. Traditional Variational Modal decomposition (VMD) is susceptible to the influence of the modal decomposition order K and the penalty factor α when decomposing harmonic signals. This paper proposes an adaptive parameter selection method for VMD based on an improved Triangular Topology Aggregation Optimization (TTAO) algorithm. Firstly, the pre-set parameters of variational modal decomposition—modal order K and penalty factor α—exhibit strong coupling. Conventional optimization algorithms cannot effectively coordinate adjustments to both parameters. This paper employs an enhanced TTAO algorithm, whose triangular topology unit structure and dual aggregation mechanism enable simultaneous adjustment of modal order K and penalty factor α, effectively resolving their coupled optimization challenge. Using minimum envelope entropy as the fitness function, the algorithm obtains an optimized parameter combination for VMD to decompose the signal. Subsequently, dominant modal components are selected based on Pearson’s correlation coefficients for reconstruction, with harmonic parameters precisely identified using the Prony algorithm. Simulation results demonstrate that under a 20 dB noise environment, the proposed method achieves a signal-to-noise ratio (SNR) of 25.6952 for steady-state harmonics, with a root mean square error (RMSE) of 0.4889. The mean errors for frequency and amplitude identification are 0.055% and 3.085%, respectively, significantly outperforming methods such as PSO-VMD and EMD. Moreover, the runtime of our model is markedly shorter than that of the PSO-VMD algorithm, effectively resolving the symmetric trade-off between recognition accuracy and runtime inherent in variational modal decomposition.
- Open Access
Research on Broadband Oscillation Mode Identification Based on Improved Symplectic Geometry Algorithm
The rapid integration of renewable energy sources into modern power systems has exacerbated power quality challenges, particularly broadband oscillation phenomena that threaten grid symmetry and stability. The proposed symplectic geometric mode decomposition (SGMD) method advances the field; however, issues like mode aliasing and over-decomposition are unresolved within the symplectic geometric paradigm. To resolve these limitations in existing methods, this paper proposes a novel time-frequency-coupled symmetry mode decomposition technique. The approach first applies symplectic symmetry geometric mode in the time domain, then iteratively refines the modes using frequency-domain Local Outlier Factor (LOF) detection to suppress aliasing. Final mode integration employs Dynamic Time Warping (DTW) for optimal alignment, enabling accurate extraction of oscillation characteristics. Comparative evaluations demonstrate that the average error of the amplitude and frequency identification of the proposed method are 1.39% and 0.029%, which are lower than the results of SVD at 5.09% and 0.043%.
Open AccessResearch on Broadband Oscillation Mode Identification Based on Improved Symplectic Geometry Algorithm
The rapid integration of renewable energy sources into modern power systems has exacerbated power quality challenges, particularly broadband oscillation phenomena that threaten grid symmetry and stability. The proposed symplectic geometric mode decomposition (SGMD) method advances the field; however, issues like mode aliasing and over-decomposition are unresolved within the symplectic geometric paradigm. To resolve these limitations in existing methods, this paper proposes a novel time-frequency-coupled symmetry mode decomposition technique. The approach first applies symplectic symmetry geometric mode in the time domain, then iteratively refines the modes using frequency-domain Local Outlier Factor (LOF) detection to suppress aliasing. Final mode integration employs Dynamic Time Warping (DTW) for optimal alignment, enabling accurate extraction of oscillation characteristics. Comparative evaluations demonstrate that the average error of the amplitude and frequency identification of the proposed method are 1.39% and 0.029%, which are lower than the results of SVD at 5.09% and 0.043%.
- Open Access
A Fault Identification Method for Ferroresonance Based on a Gramian Angular Summation Field and an Improved Cloud Model
Due to the broad frequency domain and nonlinear characteristics of ferroresonance signals, traditional time–frequency analysis methods often face challenges such as misjudgment, difficulty in threshold setting, and noise interference when extracting features from ferroresonance overvoltage signals. A fault identification method for ferroresonance based on the Gramian Angular Summation Field (GASF) and an improved cloud model is proposed to address the identified problems. Firstly, this paper employs Symplectic Geometric Mode Decomposition (SGMD) to denoise the ferroresonance overvoltage signal, extract its characteristic modal components, and reconstruct the signal. Secondly, the reconstructed one-dimensional signal is transformed into a two-dimensional image using GASF. Subsequently, we extract texture features of GASF images with different resonance types by grey-level co-occurrence matrix (GLCM) and establish the corresponding cloud distribution model to characterize these textures. Finally, we calculate the membership degree between the standard cloud for the signal to be identified and the index cloud in the cloud distribution model, enabling accurate identification of the type of ferroresonance based on this membership degree. Simulation and actual measurement data analyses validate the feasibility and effectiveness of the proposed method.
Open AccessA Fault Identification Method for Ferroresonance Based on a Gramian Angular Summation Field and an Improved Cloud Model
Due to the broad frequency domain and nonlinear characteristics of ferroresonance signals, traditional time–frequency analysis methods often face challenges such as misjudgment, difficulty in threshold setting, and noise interference when extracting features from ferroresonance overvoltage signals. A fault identification method for ferroresonance based on the Gramian Angular Summation Field (GASF) and an improved cloud model is proposed to address the identified problems. Firstly, this paper employs Symplectic Geometric Mode Decomposition (SGMD) to denoise the ferroresonance overvoltage signal, extract its characteristic modal components, and reconstruct the signal. Secondly, the reconstructed one-dimensional signal is transformed into a two-dimensional image using GASF. Subsequently, we extract texture features of GASF images with different resonance types by grey-level co-occurrence matrix (GLCM) and establish the corresponding cloud distribution model to characterize these textures. Finally, we calculate the membership degree between the standard cloud for the signal to be identified and the index cloud in the cloud distribution model, enabling accurate identification of the type of ferroresonance based on this membership degree. Simulation and actual measurement data analyses validate the feasibility and effectiveness of the proposed method.
- 2 April 2024
- Published by Springer Nature
- p. 395-403
Probability Density Assessment of Voltage Sag Based on Hamiltonian Monte Carlo Method
- 2 April 2024
- Published by Springer Nature
- p. 395-403
Probability Density Assessment of Voltage Sag Based on Hamiltonian Monte Carlo Method
- Open Access
- 22 March 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0299632
Ultra short term power load forecasting based on the fusion of Seq2Seq BiLSTM and multi head attention mechanism
Ultra-short-term power load forecasting is beneficial to improve the economic efficiency of power systems and ensure the safe and stable operation of power grids. As the volatility and randomness of loads in power systems, make it difficult to achieve accurate and reliable power load forecasting, a sequence-to-sequence based learning framework is proposed to learn feature information in different dimensions synchronously. Convolutional Neural Networks(CNN) Combined with Bidirectional Long Short Term Memory(BiLSTM) Networks is constructed in the encoder to extract the correlated timing features embedded in external factors affecting power loads. The parallel BiLSTM network is constructed in the decoder to mine the power load timing information in different regions separately. The multi-headed attention mechanism is introduced to fuse the BiLSTM hidden layer state information in different components to further highlight the key information representation. The load forecastion results in different regions are output through the fully connected layer. The model proposed in this paper has the advantage of high forecastion accuracy through the example analysis of real power load data.
- 22 March 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0299632
Open AccessUltra short term power load forecasting based on the fusion of Seq2Seq BiLSTM and multi head attention mechanism
Ultra-short-term power load forecasting is beneficial to improve the economic efficiency of power systems and ensure the safe and stable operation of power grids. As the volatility and randomness of loads in power systems, make it difficult to achieve accurate and reliable power load forecasting, a sequence-to-sequence based learning framework is proposed to learn feature information in different dimensions synchronously. Convolutional Neural Networks(CNN) Combined with Bidirectional Long Short Term Memory(BiLSTM) Networks is constructed in the encoder to extract the correlated timing features embedded in external factors affecting power loads. The parallel BiLSTM network is constructed in the decoder to mine the power load timing information in different regions separately. The multi-headed attention mechanism is introduced to fuse the BiLSTM hidden layer state information in different components to further highlight the key information representation. The load forecastion results in different regions are output through the fully connected layer. The model proposed in this paper has the advantage of high forecastion accuracy through the example analysis of real power load data.
- Open Access
Research on Voltage Sag Loss Assessment Based on a Two-Stage Taguchi Quality Perspective Method
Voltage sags resulting from symmetrical or asymmetrical faults pose a significant threat to power quality. In response to this challenge, a voltage sag loss assessment method based on a two-stage Taguchi quality perspective approach is proposed to address the quantitative analysis of voltage sag economic losses. Initially, using the Taguchi quality perspective method, single-index quality loss functions are separately established for voltage sag magnitude and fault duration. Subsequently, by introducing a comprehensive load tolerance curve, sensitivity parameters within the quality loss function are accurately calculated. This yields a deterministic model for voltage sag assessment. Building upon this, the relative impact of the two indices on voltage sag loss is evaluated using the quality loss function. Consequently, a comprehensive loss model under the influence of multiple indices is formed by integrating two single-index evaluation models. The simulation results indicate that this method can effectively assess the economic losses of voltage sags under the combined influence of multiple factors. Compared to the original economic loss assessment method, it improves quantitative accuracy by approximately 3.72%. Moreover, the method reduces the computational complexity of loss assessment through the consolidation of intervals with similar sensitivity parameters.
Open AccessResearch on Voltage Sag Loss Assessment Based on a Two-Stage Taguchi Quality Perspective Method
Voltage sags resulting from symmetrical or asymmetrical faults pose a significant threat to power quality. In response to this challenge, a voltage sag loss assessment method based on a two-stage Taguchi quality perspective approach is proposed to address the quantitative analysis of voltage sag economic losses. Initially, using the Taguchi quality perspective method, single-index quality loss functions are separately established for voltage sag magnitude and fault duration. Subsequently, by introducing a comprehensive load tolerance curve, sensitivity parameters within the quality loss function are accurately calculated. This yields a deterministic model for voltage sag assessment. Building upon this, the relative impact of the two indices on voltage sag loss is evaluated using the quality loss function. Consequently, a comprehensive loss model under the influence of multiple indices is formed by integrating two single-index evaluation models. The simulation results indicate that this method can effectively assess the economic losses of voltage sags under the combined influence of multiple factors. Compared to the original economic loss assessment method, it improves quantitative accuracy by approximately 3.72%. Moreover, the method reduces the computational complexity of loss assessment through the consolidation of intervals with similar sensitivity parameters.
- Open Access
A New Method for the Analysis of Broadband Oscillation Mode of New Energy Stations
The accurate identification of the broadband oscillation mode is the premise of solving the resonance risk of new energy stations. Reviewing the traditional Prony algorithm, the problems of the high model order and poor noise immunity in broadband oscillation mode are identified. The accuracy and running time of the Variational mode decomposition (VMD) is a symmetric trade-off problem. An improved strategy based on VMD is proposed. Firstly, the optimal value of the number of modes and penalty factors obtained by a particle swarm optimization algorithm is input into VMD to decompose the signal into multiple modes. Then, combined with the energy threshold method, the denoising and signal reconstruction of each mode component after decomposition are carried out. Finally, the Prony algorithm is used to identify the oscillation mode of the original signal and the reconstructed signal, respectively. The Signal-to-noise ratio (SNR) and model order are compared and analyzed. Through the analysis of the example and simulation data, it is shown that the proposed method effectively solves the problem of poor engineering adaptability of the traditional Prony algorithm. It also can accurately obtain the time-domain characteristics of broadband oscillation, which has a promising future in the engineering application.
Open AccessA New Method for the Analysis of Broadband Oscillation Mode of New Energy Stations
The accurate identification of the broadband oscillation mode is the premise of solving the resonance risk of new energy stations. Reviewing the traditional Prony algorithm, the problems of the high model order and poor noise immunity in broadband oscillation mode are identified. The accuracy and running time of the Variational mode decomposition (VMD) is a symmetric trade-off problem. An improved strategy based on VMD is proposed. Firstly, the optimal value of the number of modes and penalty factors obtained by a particle swarm optimization algorithm is input into VMD to decompose the signal into multiple modes. Then, combined with the energy threshold method, the denoising and signal reconstruction of each mode component after decomposition are carried out. Finally, the Prony algorithm is used to identify the oscillation mode of the original signal and the reconstructed signal, respectively. The Signal-to-noise ratio (SNR) and model order are compared and analyzed. Through the analysis of the example and simulation data, it is shown that the proposed method effectively solves the problem of poor engineering adaptability of the traditional Prony algorithm. It also can accurately obtain the time-domain characteristics of broadband oscillation, which has a promising future in the engineering application.
- Open Access
Multi-Objective Optimal Scheduling for Multi-Renewable Energy Power System Considering Flexibility Constraints
As renewable energy penetration increases, the lack of flexibility in a multi-renewable power system can seriously affect its own economics and reliability. To address this issue, three objectives are considered in this study: power fluctuations on tie-line, operating cost, and curtailment rate of renewable energy. Presented also is an optimal day-ahead scheduling model based on the MREPS for distributed generations with flexibility constraints. The multi-objective particle swarm optimization (MOPSO) algorithm can be applied to obtain a set of Pareto non-dominated solutions for the day-ahead scheduling strategy with the proposed model. By using fuzzy comprehensive evaluation, the optimal compromise solution is determined in the set. The presented method sacrifices a small amount of economy and power fluctuation, but it can reduce the deviation between forecast and realized power fluctuations on the tie-line, while improving the utilization of renewable energy.
Open AccessMulti-Objective Optimal Scheduling for Multi-Renewable Energy Power System Considering Flexibility Constraints
As renewable energy penetration increases, the lack of flexibility in a multi-renewable power system can seriously affect its own economics and reliability. To address this issue, three objectives are considered in this study: power fluctuations on tie-line, operating cost, and curtailment rate of renewable energy. Presented also is an optimal day-ahead scheduling model based on the MREPS for distributed generations with flexibility constraints. The multi-objective particle swarm optimization (MOPSO) algorithm can be applied to obtain a set of Pareto non-dominated solutions for the day-ahead scheduling strategy with the proposed model. By using fuzzy comprehensive evaluation, the optimal compromise solution is determined in the set. The presented method sacrifices a small amount of economy and power fluctuation, but it can reduce the deviation between forecast and realized power fluctuations on the tie-line, while improving the utilization of renewable energy.
- Open Access
- 1 April 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1894 (1) , 012022
Measurement method of adjacent harmonics or interharmonics based on Gaussian radial basis function frequency domain approximation
Interpolated FFT method based on window function is a common method to measure harmonics or interharmonics in power systems. When the frequency resolution is insufficient or the main lobe of the window function is wide, the spectrum of adjacent harmonics or interharmonics may have aliasing of the main lobe, and it is difficult to accurately measure the parameters of harmonics or interharmonics. This paper proposes a modeling method for adjacent harmonics or adjacent interharmonics. The Fourier transform (FT) of the Gaussian function is still a Gaussian function. According to this feature, after adding a Gaussian window in the time domain and calculating the FFT spectrum, the real and imaginary parts of the aliased spectrum are decomposed into a series of linear superpositions of Gaussian radial basis functions (RBF). The center of the RBF is the frequency of the harmonic or interharmonic, and the amplitude and phase can also be calculated by the superposition coefficient of the RBF. The simulation verifies the effectiveness of the method.
- 1 April 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1894 (1) , 012022
Open AccessMeasurement method of adjacent harmonics or interharmonics based on Gaussian radial basis function frequency domain approximation
Interpolated FFT method based on window function is a common method to measure harmonics or interharmonics in power systems. When the frequency resolution is insufficient or the main lobe of the window function is wide, the spectrum of adjacent harmonics or interharmonics may have aliasing of the main lobe, and it is difficult to accurately measure the parameters of harmonics or interharmonics. This paper proposes a modeling method for adjacent harmonics or adjacent interharmonics. The Fourier transform (FT) of the Gaussian function is still a Gaussian function. According to this feature, after adding a Gaussian window in the time domain and calculating the FFT spectrum, the real and imaginary parts of the aliased spectrum are decomposed into a series of linear superpositions of Gaussian radial basis functions (RBF). The center of the RBF is the frequency of the harmonic or interharmonic, and the amplitude and phase can also be calculated by the superposition coefficient of the RBF. The simulation verifies the effectiveness of the method.