Bo Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Guo
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Jianbo Dai
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
2 shared publications - Hang Zhou
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Jing Dai
Faculty of Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Ke Yin
Beijing Xinleineng Technology Co., Ltd., Chengdu Branch, Chengdu 610213, China
1 shared publication - Ketong Lu
Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication
Latest Publications
- Open Access
A Fault Identification Method for Ferroresonance Based on a Gramian Angular Summation Field and an Improved Cloud Model
Due to the broad frequency domain and nonlinear characteristics of ferroresonance signals, traditional time–frequency analysis methods often face challenges such as misjudgment, difficulty in threshold setting, and noise interference when extracting features from ferroresonance overvoltage signals. A fault identification method for ferroresonance based on the Gramian Angular Summation Field (GASF) and an improved cloud model is proposed to address the identified problems. Firstly, this paper employs Symplectic Geometric Mode Decomposition (SGMD) to denoise the ferroresonance overvoltage signal, extract its characteristic modal components, and reconstruct the signal. Secondly, the reconstructed one-dimensional signal is transformed into a two-dimensional image using GASF. Subsequently, we extract texture features of GASF images with different resonance types by grey-level co-occurrence matrix (GLCM) and establish the corresponding cloud distribution model to characterize these textures. Finally, we calculate the membership degree between the standard cloud for the signal to be identified and the index cloud in the cloud distribution model, enabling accurate identification of the type of ferroresonance based on this membership degree. Simulation and actual measurement data analyses validate the feasibility and effectiveness of the proposed method.
Open AccessA Fault Identification Method for Ferroresonance Based on a Gramian Angular Summation Field and an Improved Cloud Model
Due to the broad frequency domain and nonlinear characteristics of ferroresonance signals, traditional time–frequency analysis methods often face challenges such as misjudgment, difficulty in threshold setting, and noise interference when extracting features from ferroresonance overvoltage signals. A fault identification method for ferroresonance based on the Gramian Angular Summation Field (GASF) and an improved cloud model is proposed to address the identified problems. Firstly, this paper employs Symplectic Geometric Mode Decomposition (SGMD) to denoise the ferroresonance overvoltage signal, extract its characteristic modal components, and reconstruct the signal. Secondly, the reconstructed one-dimensional signal is transformed into a two-dimensional image using GASF. Subsequently, we extract texture features of GASF images with different resonance types by grey-level co-occurrence matrix (GLCM) and establish the corresponding cloud distribution model to characterize these textures. Finally, we calculate the membership degree between the standard cloud for the signal to be identified and the index cloud in the cloud distribution model, enabling accurate identification of the type of ferroresonance based on this membership degree. Simulation and actual measurement data analyses validate the feasibility and effectiveness of the proposed method.
- Open Access
A New Method for the Analysis of Broadband Oscillation Mode of New Energy Stations
The accurate identification of the broadband oscillation mode is the premise of solving the resonance risk of new energy stations. Reviewing the traditional Prony algorithm, the problems of the high model order and poor noise immunity in broadband oscillation mode are identified. The accuracy and running time of the Variational mode decomposition (VMD) is a symmetric trade-off problem. An improved strategy based on VMD is proposed. Firstly, the optimal value of the number of modes and penalty factors obtained by a particle swarm optimization algorithm is input into VMD to decompose the signal into multiple modes. Then, combined with the energy threshold method, the denoising and signal reconstruction of each mode component after decomposition are carried out. Finally, the Prony algorithm is used to identify the oscillation mode of the original signal and the reconstructed signal, respectively. The Signal-to-noise ratio (SNR) and model order are compared and analyzed. Through the analysis of the example and simulation data, it is shown that the proposed method effectively solves the problem of poor engineering adaptability of the traditional Prony algorithm. It also can accurately obtain the time-domain characteristics of broadband oscillation, which has a promising future in the engineering application.
Open AccessA New Method for the Analysis of Broadband Oscillation Mode of New Energy Stations
The accurate identification of the broadband oscillation mode is the premise of solving the resonance risk of new energy stations. Reviewing the traditional Prony algorithm, the problems of the high model order and poor noise immunity in broadband oscillation mode are identified. The accuracy and running time of the Variational mode decomposition (VMD) is a symmetric trade-off problem. An improved strategy based on VMD is proposed. Firstly, the optimal value of the number of modes and penalty factors obtained by a particle swarm optimization algorithm is input into VMD to decompose the signal into multiple modes. Then, combined with the energy threshold method, the denoising and signal reconstruction of each mode component after decomposition are carried out. Finally, the Prony algorithm is used to identify the oscillation mode of the original signal and the reconstructed signal, respectively. The Signal-to-noise ratio (SNR) and model order are compared and analyzed. Through the analysis of the example and simulation data, it is shown that the proposed method effectively solves the problem of poor engineering adaptability of the traditional Prony algorithm. It also can accurately obtain the time-domain characteristics of broadband oscillation, which has a promising future in the engineering application.