Christian Aurup
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian Aurup has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Elisa Evgenia Konofagou
Department of Biomedical Engineering, Columbia University, New York, USA
9 shared publications - Hermes Arytto Salles Kamimura
Columbia University
7 shared publications - Julien Grondin
Department of Biomedical Engineering, Columbia University, New York, New York, USA
2 shared publications Shih-Ying Wu
Department of Biomedical Engineering, Columbia University, New York, NY, USA
2 shared publications- Stephen Alexander Lee
Department of Engineering Physics, Polytechnique Montréal, Montreal, QC, Canada
2 shared publications - Wenlan Zheng
Department of Biomedical Engineering, Columbia University, New York, NY, USA
2 shared publications
Latest Publications
- Open Access
Transcranial Functional Ultrasound Imaging Detects Focused Ultrasound Neuromodulation Induced Hemodynamic Changes In Vivo
Background: Focused ultrasound (FUS) is an emerging non-invasive technique for neuromodulation in the central nervous system (CNS). Functional ultrasound imaging (fUSI) leverages ultrafast Power Doppler Imaging (PDI) to detect changes in cerebral blood volume (CBV), which correlate well with neuronal activity and thus hold promise to monitor brain responses to FUS. Objective: Investigate the immediate and short-term effects of transcranial FUS neuromodulation in the brain with fUSI by characterizing hemodynamic responses. Methods: We designed a setup that aligns a FUS transducer with a linear array to allow immediate subsequent monitoring of the hemodynamic response with fUSI during and after FUS neuromodulation (FUS-fUSI) in lightly anesthetized mice. We investigated the effects of varying pressures and transducer positions on the hemodynamic responses. Results: We found that higher FUS pressures increase the size of the activated brain area, as well as the magnitude of change in CBV and could show that sham sonications did not produce hemodynamic responses. Unilateral sonications resulted in bilateral hemodynamic changes with a significantly stronger response on the ipsilateral side. FUS neuromodulation in mice with a cranial window showed distinct activation patterns that were frequency-dependent and different from the activation patterns observed in the transcranial model. Conclusion: fUSI is hereby shown capable of transcranially monitoring online and short-term hemodynamic effects in the brain during and following FUS neuromodulation
Open AccessTranscranial Functional Ultrasound Imaging Detects Focused Ultrasound Neuromodulation Induced Hemodynamic Changes In Vivo
Background: Focused ultrasound (FUS) is an emerging non-invasive technique for neuromodulation in the central nervous system (CNS). Functional ultrasound imaging (fUSI) leverages ultrafast Power Doppler Imaging (PDI) to detect changes in cerebral blood volume (CBV), which correlate well with neuronal activity and thus hold promise to monitor brain responses to FUS. Objective: Investigate the immediate and short-term effects of transcranial FUS neuromodulation in the brain with fUSI by characterizing hemodynamic responses. Methods: We designed a setup that aligns a FUS transducer with a linear array to allow immediate subsequent monitoring of the hemodynamic response with fUSI during and after FUS neuromodulation (FUS-fUSI) in lightly anesthetized mice. We investigated the effects of varying pressures and transducer positions on the hemodynamic responses. Results: We found that higher FUS pressures increase the size of the activated brain area, as well as the magnitude of change in CBV and could show that sham sonications did not produce hemodynamic responses. Unilateral sonications resulted in bilateral hemodynamic changes with a significantly stronger response on the ipsilateral side. FUS neuromodulation in mice with a cranial window showed distinct activation patterns that were frequency-dependent and different from the activation patterns observed in the transcranial model. Conclusion: fUSI is hereby shown capable of transcranially monitoring online and short-term hemodynamic effects in the brain during and following FUS neuromodulation
- 30 November 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (3) , 908-917
Evaluation of Non-invasive Optogenetic Stimulation with Transcranial Functional Ultrasound Imaging
- 30 November 2022
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (3) , 908-917
Evaluation of Non-invasive Optogenetic Stimulation with Transcranial Functional Ultrasound Imaging
- 23 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (1) , 164-177
Real-Time Passive Acoustic Mapping Using Sparse Matrix Multiplication
Passive acoustic mapping enables the spatiotemporal monitoring of cavitation with circulating microbubbles during focused ultrasound (FUS)-mediated blood-brain barrier opening. However, the computational load for processing large data sets of cavitation maps or more complex algorithms limit the visualization in real-time for treatment monitoring and adjustment. In this study, we implemented a graphical processing unit (GPU)-accelerated sparse matrix-based beamforming and time exposure acoustics in a neuronavigation-guided ultrasound system for real-time spatiotemporal monitoring of cavitation. The system performance was tested in silico through benchmarking, in vitro using nonhuman primate (NHP) and human skull specimens, and demonstrated in vivo in NHPs. We demonstrated the stability of the cavitation map for integration times longer than 62.5 μs. A compromise between real-time displaying and cavitation map quality obtained from beamformed RF data sets with a size of 2000×128×30 (axial pixels × lateral pixels × samples) was achieved for an integration time of 1.44 μs, which required a computational time of 0.27 s (frame rate of 3.7 Hz) and could be displayed in real-time between pulses at PRF = 2 Hz. Our benchmarking tests show that the GPU sparse-matrix algorithm processed the RF data set at a computational rate of 0.03 ± 0.01 μs/pixel/sample, which enables adjusting the frame rate and the integration time as needed. The neuronavigation system with real-time implementation of cavitation mapping facilitated the localization of the cavitation activity and helped to identify distortions due to FUS phase aberration. The in vivo test of the method demonstrated the feasibility of GPU-accelerated sparse matrix computing in a close to a clinical condition, where focus distortions exemplify problems during treatment. These experimental conditions show the need for spatiotemporal monitoring of cavitation with real-time capability that enables the operator to correct or halt the sonication in case substantial aberrations are observed.
- 23 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (1) , 164-177
Real-Time Passive Acoustic Mapping Using Sparse Matrix Multiplication
Passive acoustic mapping enables the spatiotemporal monitoring of cavitation with circulating microbubbles during focused ultrasound (FUS)-mediated blood-brain barrier opening. However, the computational load for processing large data sets of cavitation maps or more complex algorithms limit the visualization in real-time for treatment monitoring and adjustment. In this study, we implemented a graphical processing unit (GPU)-accelerated sparse matrix-based beamforming and time exposure acoustics in a neuronavigation-guided ultrasound system for real-time spatiotemporal monitoring of cavitation. The system performance was tested in silico through benchmarking, in vitro using nonhuman primate (NHP) and human skull specimens, and demonstrated in vivo in NHPs. We demonstrated the stability of the cavitation map for integration times longer than 62.5 μs. A compromise between real-time displaying and cavitation map quality obtained from beamformed RF data sets with a size of 2000×128×30 (axial pixels × lateral pixels × samples) was achieved for an integration time of 1.44 μs, which required a computational time of 0.27 s (frame rate of 3.7 Hz) and could be displayed in real-time between pulses at PRF = 2 Hz. Our benchmarking tests show that the GPU sparse-matrix algorithm processed the RF data set at a computational rate of 0.03 ± 0.01 μs/pixel/sample, which enables adjusting the frame rate and the integration time as needed. The neuronavigation system with real-time implementation of cavitation mapping facilitated the localization of the cavitation activity and helped to identify distortions due to FUS phase aberration. The in vivo test of the method demonstrated the feasibility of GPU-accelerated sparse matrix computing in a close to a clinical condition, where focus distortions exemplify problems during treatment. These experimental conditions show the need for spatiotemporal monitoring of cavitation with real-time capability that enables the operator to correct or halt the sonication in case substantial aberrations are observed.
- 1 April 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (2) , 026026
Image-guided focused ultrasound modulates electrically evoked motor neuronal activity in the mouse peripheral nervous system in vivo
Objective . Focused ultrasound (FUS) has recently been demonstrated capable of exciting motor neuronal activity. However, comprehensive understanding of elucidated excitatory and inhibitory effects is required to better assess FUS-mediated modulation. In this study, we demonstrate that image-guided FUS can selectively modulate motor neuron activity in the mouse sciatic nerve in vivo and attribute motor responses to thermal effects . Approach . FUS was applied on the sciatic nerve of anesthetized mice in vivo through the intact skin and muscle using ultrasound imaging for targeting. Both excitatory and inhibitory effects were recorded using electromyography (EMG) along with muscle response of the hind limb. The effects of FUS modulation versus heating by invasive alternative heating source (AHS) on electrically evoked EMG responses in the sciatic nerve in vivo were also investigated. The safety and reversibility of the technique were validated using histology and EMG recovery. Main results . The FUS was capable of eliciting motor neuronal activity comparable to electrical stimulation ES, and facilitating motor neuronal response on electrically evoked potentials with temperature elevation up to 11.5 °C ± 0.3 °C (PRF ⩽ 40 Hz). On the other hand, FUS-induced temperature elevations above 15.1 °C ± 1.6 °C (PRF ⩾ 100 Hz) resulted in the suppression of electrically-evoked motor neuronal activity along with a decrease in EMG latency and area under the curve (AUC), which was validated against the invasive AHS with temperature elevation of 18.1 °C ± 8.5 °C. Histological findings along with EMG responses after FUS modulation demonstrated a reversible or irreversible modulation. Significance . The findings reported herein indicate that image-guided FUS (PRF ⩽ 100 Hz) induces safe and controllable modulation of involuntarily evoked motor neuron activity in vivo .
- 1 April 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (2) , 026026
Image-guided focused ultrasound modulates electrically evoked motor neuronal activity in the mouse peripheral nervous system in vivo
Objective . Focused ultrasound (FUS) has recently been demonstrated capable of exciting motor neuronal activity. However, comprehensive understanding of elucidated excitatory and inhibitory effects is required to better assess FUS-mediated modulation. In this study, we demonstrate that image-guided FUS can selectively modulate motor neuron activity in the mouse sciatic nerve in vivo and attribute motor responses to thermal effects . Approach . FUS was applied on the sciatic nerve of anesthetized mice in vivo through the intact skin and muscle using ultrasound imaging for targeting. Both excitatory and inhibitory effects were recorded using electromyography (EMG) along with muscle response of the hind limb. The effects of FUS modulation versus heating by invasive alternative heating source (AHS) on electrically evoked EMG responses in the sciatic nerve in vivo were also investigated. The safety and reversibility of the technique were validated using histology and EMG recovery. Main results . The FUS was capable of eliciting motor neuronal activity comparable to electrical stimulation ES, and facilitating motor neuronal response on electrically evoked potentials with temperature elevation up to 11.5 °C ± 0.3 °C (PRF ⩽ 40 Hz). On the other hand, FUS-induced temperature elevations above 15.1 °C ± 1.6 °C (PRF ⩾ 100 Hz) resulted in the suppression of electrically-evoked motor neuronal activity along with a decrease in EMG latency and area under the curve (AUC), which was validated against the invasive AHS with temperature elevation of 18.1 °C ± 8.5 °C. Histological findings along with EMG responses after FUS modulation demonstrated a reversible or irreversible modulation. Significance . The findings reported herein indicate that image-guided FUS (PRF ⩽ 100 Hz) induces safe and controllable modulation of involuntarily evoked motor neuron activity in vivo .
- 11 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (1) , 70-80
Iterative Curve Fitting of the Bioheat Transfer Equation for Thermocouple-Based Temperature Estimation $In~ Vitro$ and $In~ Vivo$Temperature measurements with thin thermocouples embedded in ultrasound fields are strongly subjected to a viscous heating artifact (VHA). The artifact contribution decays over time; therefore, it can be minimized at late temperature readings. However, previous studies have failed to demonstrate a rigorous method for determining the optimal time point at which the artifact contribution is negligible. In this study, we present an iterative processing method based on successive curve fittings using an artifact-independent model. The fitting starting point moves at each iteration until the maximum R2 indicates where the viscous heating is minimum. A solution of the bioheat transfer equation is used to account for blood perfusion, thus enabling in vivo measurements. Three T-type thermocouples with different diameters and sensitivities were assessed in an excised canine liver and in the mouse brain in vivo. We found that the artifact constitutes up to 81% ± 5% of wire thermocouple readings. The best-fit time varied in the liver samples (n = 3) from 0 to 3.335 ± 0.979 s and in the mouse brain (n = 5) from 0 to 0.498 ± 0.457 s at variable experimental conditions, which clearly demonstrates the need of the method for finding the appropriate starting time point of the fit. This study introduces a statistical method to determine the best time to fit a curve that can back-estimate temperature in tissues under ultrasound exposure using thermocouples. This method allows temperature evaluation in vivo and in vitro during a validation and safety assessment of a wide range of therapeutic and diagnostic ultrasound modalities.
- 11 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (1) , 70-80
Iterative Curve Fitting of the Bioheat Transfer Equation for Thermocouple-Based Temperature Estimation $In~ Vitro$ and $In~ Vivo$Temperature measurements with thin thermocouples embedded in ultrasound fields are strongly subjected to a viscous heating artifact (VHA). The artifact contribution decays over time; therefore, it can be minimized at late temperature readings. However, previous studies have failed to demonstrate a rigorous method for determining the optimal time point at which the artifact contribution is negligible. In this study, we present an iterative processing method based on successive curve fittings using an artifact-independent model. The fitting starting point moves at each iteration until the maximum R2 indicates where the viscous heating is minimum. A solution of the bioheat transfer equation is used to account for blood perfusion, thus enabling in vivo measurements. Three T-type thermocouples with different diameters and sensitivities were assessed in an excised canine liver and in the mouse brain in vivo. We found that the artifact constitutes up to 81% ± 5% of wire thermocouple readings. The best-fit time varied in the liver samples (n = 3) from 0 to 3.335 ± 0.979 s and in the mouse brain (n = 5) from 0 to 0.498 ± 0.457 s at variable experimental conditions, which clearly demonstrates the need of the method for finding the appropriate starting time point of the fit. This study introduces a statistical method to determine the best time to fit a curve that can back-estimate temperature in tissues under ultrasound exposure using thermocouples. This method allows temperature evaluation in vivo and in vitro during a validation and safety assessment of a wide range of therapeutic and diagnostic ultrasound modalities.
- 20 May 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (20) , 203702
Numerical modeling of ultrasound heating for the correction of viscous heating artifacts in soft tissue temperature measurements
Measuring temperature during focused ultrasound (FUS) procedures is critical for characterization, calibration, and monitoring to ultimately ensure safety and efficacy. Despite the low cost and the high spatial and temporal resolutions of temperature measurements using thermocouples, the viscous heating (VH) artifact at the thermocouple-tissue interface requires reading corrections for correct thermometric analysis. In this study, a simulation pipeline is proposed to correct the VH artifact arising from temperature measurements using thermocouples in FUS fields. The numerical model consists of simulating a primary source of heating due to ultrasound absorption and a secondary source of heating from viscous forces generated by the thermocouple in the FUS field. Our numerical validation found that up to 90% of the measured temperature rise was due to VH effects. Experimental temperature measurements were performed using thermocouples embedded in fresh chicken breast samples. Temperature corrections were demonstrated for single high-intensity FUS pulses at 3.1 MHz and for multiple pulses (3.1 MHz, 100 Hz, and 500 Hz pulse repetition frequency). The VH accumulated during sonications and produced a temperature increase of 3.1 °C and 15.3 °C for the single and multiple pulse sequences, respectively. The methodology presented here enables the decoupling of the temperature increase generated by absorption and VH. Thus, more reliable temperature measurements can be extracted from thermocouple measurements by correcting for VH.
- 20 May 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 114 (20) , 203702
Numerical modeling of ultrasound heating for the correction of viscous heating artifacts in soft tissue temperature measurements
Measuring temperature during focused ultrasound (FUS) procedures is critical for characterization, calibration, and monitoring to ultimately ensure safety and efficacy. Despite the low cost and the high spatial and temporal resolutions of temperature measurements using thermocouples, the viscous heating (VH) artifact at the thermocouple-tissue interface requires reading corrections for correct thermometric analysis. In this study, a simulation pipeline is proposed to correct the VH artifact arising from temperature measurements using thermocouples in FUS fields. The numerical model consists of simulating a primary source of heating due to ultrasound absorption and a secondary source of heating from viscous forces generated by the thermocouple in the FUS field. Our numerical validation found that up to 90% of the measured temperature rise was due to VH effects. Experimental temperature measurements were performed using thermocouples embedded in fresh chicken breast samples. Temperature corrections were demonstrated for single high-intensity FUS pulses at 3.1 MHz and for multiple pulses (3.1 MHz, 100 Hz, and 500 Hz pulse repetition frequency). The VH accumulated during sonications and produced a temperature increase of 3.1 °C and 15.3 °C for the single and multiple pulse sequences, respectively. The methodology presented here enables the decoupling of the temperature increase generated by absorption and VH. Thus, more reliable temperature measurements can be extracted from thermocouple measurements by correcting for VH.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
High-Resolution, Focused Ultrasound-Mediated Neuromodulation and Detailed Analysis of Electromyography Characteristics Reveals a High Degree of Spatial Specificity in Elicited Responses in Mice in Vivo
Focused ultrasound (FUS) has demonstrated the ability to modulate nervous system activity in animals. Recently, higher frequency focused transducers have been used to successfully elicit motor responses in mice in vivo. Despite this success, quantitative analyses of the temporal and magnitude-related characteristics of FUS elicited motor responses measured with electromyography (EMG) and the spatial specificity of those responses have been poorly described. In this study, we use a focused transducer with high spatial resolution (1mm lateral focal diameter) and EMG to evaluate six quantitative EMG response characteristics. Results demonstrate that these responses are highly specific to the brain volume acted upon by the FUS.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
High-Resolution, Focused Ultrasound-Mediated Neuromodulation and Detailed Analysis of Electromyography Characteristics Reveals a High Degree of Spatial Specificity in Elicited Responses in Mice in Vivo
Focused ultrasound (FUS) has demonstrated the ability to modulate nervous system activity in animals. Recently, higher frequency focused transducers have been used to successfully elicit motor responses in mice in vivo. Despite this success, quantitative analyses of the temporal and magnitude-related characteristics of FUS elicited motor responses measured with electromyography (EMG) and the spatial specificity of those responses have been poorly described. In this study, we use a focused transducer with high spatial resolution (1mm lateral focal diameter) and EMG to evaluate six quantitative EMG response characteristics. Results demonstrate that these responses are highly specific to the brain volume acted upon by the FUS.
- Open Access
- 22 May 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-11
Efficient Blood-Brain Barrier Opening in Primates with Neuronavigation-Guided Ultrasound and Real-Time Acoustic Mapping
Brain diseases including neurological disorders and tumors remain under treated due to the challenge to access the brain, and blood-brain barrier (BBB) restricting drug delivery which, also profoundly limits the development of pharmacological treatment. Focused ultrasound (FUS) with microbubbles is the sole method to open the BBB noninvasively, locally, and transiently and facilitate drug delivery, while translation to the clinic is challenging due to long procedure, targeting limitations, or invasiveness of current systems. In order to provide rapid, flexible yet precise applications, we have designed a noninvasive FUS and monitoring system with the protocol tested in monkeys (from in silico preplanning and simulation, real-time targeting and acoustic mapping, to post-treatment assessment). With a short procedure (30 min) similar to current clinical imaging duration or radiation therapy, the achieved targeting (both cerebral cortex and subcortical structures) and monitoring accuracy was close to the predicted 2-mm lower limit. This system would enable rapid clinical transcranial FUS applications outside of the MRI system without a stereotactic frame, thereby benefiting patients especially in the elderly population.
- 22 May 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-11
Open AccessEfficient Blood-Brain Barrier Opening in Primates with Neuronavigation-Guided Ultrasound and Real-Time Acoustic Mapping
Brain diseases including neurological disorders and tumors remain under treated due to the challenge to access the brain, and blood-brain barrier (BBB) restricting drug delivery which, also profoundly limits the development of pharmacological treatment. Focused ultrasound (FUS) with microbubbles is the sole method to open the BBB noninvasively, locally, and transiently and facilitate drug delivery, while translation to the clinic is challenging due to long procedure, targeting limitations, or invasiveness of current systems. In order to provide rapid, flexible yet precise applications, we have designed a noninvasive FUS and monitoring system with the protocol tested in monkeys (from in silico preplanning and simulation, real-time targeting and acoustic mapping, to post-treatment assessment). With a short procedure (30 min) similar to current clinical imaging duration or radiation therapy, the achieved targeting (both cerebral cortex and subcortical structures) and monitoring accuracy was close to the predicted 2-mm lower limit. This system would enable rapid clinical transcranial FUS applications outside of the MRI system without a stereotactic frame, thereby benefiting patients especially in the elderly population.
- 9 May 2018
- Published by Springer Nature in Current Behavioral Neuroscience Reports
- Vol. 5 (2) , 153-164
Modulation of Brain Function and Behavior by Focused Ultrasound
Purpose of Review The past decade has seen rapid growth in the application of focused ultrasound (FUS) as a tool for basic neuroscience research and potential treatment of brain disorders. Here, we review recent developments in our understanding of how FUS can alter brain activity, perception, and behavior when applied to the central nervous system, either alone or in combination with circulating agents. Recent Findings Focused ultrasound in the central nervous system can directly excite or inhibit neuronal activity, as well as affect perception and behavior. Combining FUS with intravenous microbubbles to open the blood-brain barrier also affects neural activity and behavior, and the effects may be more sustained than FUS alone. Opening the BBB also allows delivery of drugs that do not cross the intact BBB including viral vectors for gene delivery. Summary While further research is needed to elucidate the biophysical mechanisms, focused ultrasound, alone or in combination with other factors, is rapidly maturing as an effective technology for altering brain activity. Future challenges include refining control over targeting specificity, the volume of affected tissue, cell-type specificity (excitatory or inhibitory), and the duration of neural and behavioral effects.
- 9 May 2018
- Published by Springer Nature in Current Behavioral Neuroscience Reports
- Vol. 5 (2) , 153-164
Modulation of Brain Function and Behavior by Focused Ultrasound
Purpose of Review The past decade has seen rapid growth in the application of focused ultrasound (FUS) as a tool for basic neuroscience research and potential treatment of brain disorders. Here, we review recent developments in our understanding of how FUS can alter brain activity, perception, and behavior when applied to the central nervous system, either alone or in combination with circulating agents. Recent Findings Focused ultrasound in the central nervous system can directly excite or inhibit neuronal activity, as well as affect perception and behavior. Combining FUS with intravenous microbubbles to open the blood-brain barrier also affects neural activity and behavior, and the effects may be more sustained than FUS alone. Opening the BBB also allows delivery of drugs that do not cross the intact BBB including viral vectors for gene delivery. Summary While further research is needed to elucidate the biophysical mechanisms, focused ultrasound, alone or in combination with other factors, is rapidly maturing as an effective technology for altering brain activity. Future challenges include refining control over targeting specificity, the volume of affected tissue, cell-type specificity (excitatory or inhibitory), and the duration of neural and behavioral effects.
- Open Access
- 29 September 2016
- Published by Wiley in Medical Physics
- Vol. 43 (10) , 5730-5735
Focused ultrasound neuromodulation of cortical and subcortical brain structures using 1.9 MHz
Purpose: Ultrasound neuromodulation is a promising noninvasive technique for controlling neural activity. Previous small animal studies suffered from low targeting specificity because of the low ultrasound frequencies (<690 kHz) used. In this study, the authors demonstrated the capability of focused ultrasound (FUS) neuromodulation in the megahertz‐range to achieve superior targeting specificity in the murine brain as well as demonstrate modulation of both motor and sensory responses.Methods: FUS sonications were carried out at 1.9 MHz with 50% duty cycle, pulse repetition frequency of 1 kHz, and duration of 1 s. The robustness of the FUS neuromodulation was assessed first in sensorimotor cortex, where elicited motor activities were observed and recorded on videos and electromyography. Deeper brain regions were then targeted where pupillary dilation served as an indicative of successful modulation of subcortical brain structures.Results: Contralateral and ipsilateral movements of the hind limbs were repeatedly observed when the FUS was targeted at the sensorimotor cortex. Induced trunk and tail movements were also observed at different coordinates inside the sensorimotor cortex. At deeper targeted‐structures, FUS induced eyeball movements (superior colliculus) and pupillary dilation (pretectal nucleus, locus coeruleus, and hippocampus). Histological analysis revealed no tissue damage associated with the FUS sonications.Conclusions: The motor movements and pupillary dilation observed in this study demonstrate the capability of FUS to modulate cortical and subcortical brain structures without inducing any damage. The variety of responses observed here demonstrates the capability of FUS to perform functional brain mapping.
- 29 September 2016
- Published by Wiley in Medical Physics
- Vol. 43 (10) , 5730-5735
Open AccessFocused ultrasound neuromodulation of cortical and subcortical brain structures using 1.9 MHz
Purpose: Ultrasound neuromodulation is a promising noninvasive technique for controlling neural activity. Previous small animal studies suffered from low targeting specificity because of the low ultrasound frequencies (<690 kHz) used. In this study, the authors demonstrated the capability of focused ultrasound (FUS) neuromodulation in the megahertz‐range to achieve superior targeting specificity in the murine brain as well as demonstrate modulation of both motor and sensory responses.Methods: FUS sonications were carried out at 1.9 MHz with 50% duty cycle, pulse repetition frequency of 1 kHz, and duration of 1 s. The robustness of the FUS neuromodulation was assessed first in sensorimotor cortex, where elicited motor activities were observed and recorded on videos and electromyography. Deeper brain regions were then targeted where pupillary dilation served as an indicative of successful modulation of subcortical brain structures.Results: Contralateral and ipsilateral movements of the hind limbs were repeatedly observed when the FUS was targeted at the sensorimotor cortex. Induced trunk and tail movements were also observed at different coordinates inside the sensorimotor cortex. At deeper targeted‐structures, FUS induced eyeball movements (superior colliculus) and pupillary dilation (pretectal nucleus, locus coeruleus, and hippocampus). Histological analysis revealed no tissue damage associated with the FUS sonications.Conclusions: The motor movements and pupillary dilation observed in this study demonstrate the capability of FUS to modulate cortical and subcortical brain structures without inducing any damage. The variety of responses observed here demonstrates the capability of FUS to perform functional brain mapping.