Yue Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yue Yang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jinjun Liu
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
6 shared publications - Shaodi Ouyang
School of Electrical Engineering, Xi'an Jiaotong University, Xi'an China 710049
4 shared publications - Xingxing Chen
School of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
4 shared publications - Hongda Wu
School of electrical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi China
3 shared publications - Shuguang Song
The Hong Kong Polytechnic University
3 shared publications - Yan Zhang
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications
Latest Publications
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (12) , 14220-14236
Capacitors Voltage Ripple Complementary Control on Three-Level Boost Fed Single-Phase VSI With Enhanced Power Decoupling Capability
Power decoupling is always a strong desire for single-phase voltage source inverter (VSI) due to the inherent double-line (2ω) frequency ripple caused by the instantaneous power unbalance between dc- and ac-side. The existing solutions either apply a large capacitor or employ a small power converter to compensate it, which inevitably increases the system cost and control complexity. To overcome these drawbacks, this article performs the transient modeling analysis and it reveals that 2ω frequency power component in the converter achieves minimum value when the inductor current ripple is minimized. A novel capacitors' voltage ripple complementary control algorithm based on three-level boost fed single-phase VSI is proposed. By mitigating the 2ω power component from the inductor and redistributing the stored energy between two intermediate series-connected capacitors, the oscillating power is absorbed with notably eliminated input current ripple and significantly reduced dc-link voltage ripple. Thus, the good power quality of both dc- and ac-side is guaranteed. Furthermore, the total capacitance requirement is minimized under the given dc-link ripple tolerance without any more electric stress increment and lifetime reduction. Simulation and experiment results verify the theoretical analysis and proposed control method. It is promising in applications, where both input current ripple is strictly limited and ac output voltage quality is highly required with small dc-link capacitance.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (12) , 14220-14236
Capacitors Voltage Ripple Complementary Control on Three-Level Boost Fed Single-Phase VSI With Enhanced Power Decoupling Capability
Power decoupling is always a strong desire for single-phase voltage source inverter (VSI) due to the inherent double-line (2ω) frequency ripple caused by the instantaneous power unbalance between dc- and ac-side. The existing solutions either apply a large capacitor or employ a small power converter to compensate it, which inevitably increases the system cost and control complexity. To overcome these drawbacks, this article performs the transient modeling analysis and it reveals that 2ω frequency power component in the converter achieves minimum value when the inductor current ripple is minimized. A novel capacitors' voltage ripple complementary control algorithm based on three-level boost fed single-phase VSI is proposed. By mitigating the 2ω power component from the inductor and redistributing the stored energy between two intermediate series-connected capacitors, the oscillating power is absorbed with notably eliminated input current ripple and significantly reduced dc-link voltage ripple. Thus, the good power quality of both dc- and ac-side is guaranteed. Furthermore, the total capacitance requirement is minimized under the given dc-link ripple tolerance without any more electric stress increment and lifetime reduction. Simulation and experiment results verify the theoretical analysis and proposed control method. It is promising in applications, where both input current ripple is strictly limited and ac output voltage quality is highly required with small dc-link capacitance.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (12) , 12396-12407
A Universal ZVS Circuit Design Method for a Family of Interleaved High Step-Up Converters With Least Device Requirement
This article proposes a universal zero-voltage switching (ZVS) circuit design method for a family of interleaved dual boost diode-capacitor (IDBD) step-up converters with different voltage multiplier cell (VMC) structure and number. By utilizing one small inductor and two resonant capacitors, all the power devices in the hard-switching (HS) IDBD converters can achieve soft-switching. Besides, the increment of voltage and current stresses imposed on the semiconductor devices and passive components is minimized in comparison to the HS counterparts with the conventional SS design. Due to the voltage-clamped ability of the diode-capacitor network, the voltage stress of one switch in the constructed topologies is less than the output voltage and decreases further when the VMC number increases. Hence, the low on-state resistance switches can be used to further reduce the conduction loss. Consequently, the constructed ZVS topologies demonstrate improved efficiency with low cost and small volume. Furthermore, the high voltage gain, low-input current ripple, and low-voltage stress characteristics of the HS IDBD converters are also conserved. Finally, a 320 W prototype is built and tested to verify the theoretical analysis and efficiency improvement.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (12) , 12396-12407
A Universal ZVS Circuit Design Method for a Family of Interleaved High Step-Up Converters With Least Device Requirement
This article proposes a universal zero-voltage switching (ZVS) circuit design method for a family of interleaved dual boost diode-capacitor (IDBD) step-up converters with different voltage multiplier cell (VMC) structure and number. By utilizing one small inductor and two resonant capacitors, all the power devices in the hard-switching (HS) IDBD converters can achieve soft-switching. Besides, the increment of voltage and current stresses imposed on the semiconductor devices and passive components is minimized in comparison to the HS counterparts with the conventional SS design. Due to the voltage-clamped ability of the diode-capacitor network, the voltage stress of one switch in the constructed topologies is less than the output voltage and decreases further when the VMC number increases. Hence, the low on-state resistance switches can be used to further reduce the conduction loss. Consequently, the constructed ZVS topologies demonstrate improved efficiency with low cost and small volume. Furthermore, the high voltage gain, low-input current ripple, and low-voltage stress characteristics of the HS IDBD converters are also conserved. Finally, a 320 W prototype is built and tested to verify the theoretical analysis and efficiency improvement.
- 7 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (9) , 8555-8573
Control Strategy for Single-Phase Open-Circuit Operation of a Modular Solid-State Transformer
The solid-state transformer (SST) has the ability to operate with only two input phases which can be called single-phase open-circuit (SPO) operation. With this ability, the SST can maintain operation under permanent single-phase-to-ground faults where the fault phase must be isolated, providing a better power supply sustainability than that of the conventional low frequency transformer (LFT). In the absence of research on the SPO operation of an SST, this paper presents a study of it. The influence of SPO operation on the grid and the SST itself is analyzed. Under SPO state, the SST will inject negative-sequence current to the grid meanwhile the maximum load power will decline, thus the optimized power factor under SPO state is unity. The maximum power of Δ-SST is higher than that of the Y-SST under the SPO state owing to the Δ connection. A control strategy for the SST medium-voltage cascaded H-bridge stage is proposed. SPO current control can be achieved by controlling the positive-sequence current. A proper negative-sequence voltage can be injected to synchronize the cluster voltages to obtain a lower current total harmonic distortion and smaller DC voltage ripple. In the Δ-SST, a proper zero-sequence current can be injected to fully use the power rating of the double-cluster branch.
- 7 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (9) , 8555-8573
Control Strategy for Single-Phase Open-Circuit Operation of a Modular Solid-State Transformer
The solid-state transformer (SST) has the ability to operate with only two input phases which can be called single-phase open-circuit (SPO) operation. With this ability, the SST can maintain operation under permanent single-phase-to-ground faults where the fault phase must be isolated, providing a better power supply sustainability than that of the conventional low frequency transformer (LFT). In the absence of research on the SPO operation of an SST, this paper presents a study of it. The influence of SPO operation on the grid and the SST itself is analyzed. Under SPO state, the SST will inject negative-sequence current to the grid meanwhile the maximum load power will decline, thus the optimized power factor under SPO state is unity. The maximum power of Δ-SST is higher than that of the Y-SST under the SPO state owing to the Δ connection. A control strategy for the SST medium-voltage cascaded H-bridge stage is proposed. SPO current control can be achieved by controlling the positive-sequence current. A proper negative-sequence voltage can be injected to synchronize the cluster voltages to obtain a lower current total harmonic distortion and smaller DC voltage ripple. In the Δ-SST, a proper zero-sequence current can be injected to fully use the power rating of the double-cluster branch.
- 21 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (8) , 7310-7325
Modified Increased-Level Model Predictive Control Methods With Reduced Computation Load for Modular Multilevel Converter
- 21 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (8) , 7310-7325
Modified Increased-Level Model Predictive Control Methods With Reduced Computation Load for Modular Multilevel Converter
- 23 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (6) , 5294-5311
Control Strategy for Arc-Suppression-Coil-Grounded Star-Connected Power Electronic Transformers
The grounding of low frequency distribution transformer is a critical concern which ensures the proper operation and protection of the distribution system. The power electronic transformer (PET), as a future alternative of low frequency distribution transformer, also needs to consider the grounding. This paper is studying the operation of PET with arc suppression coil(ASC) grounding in the Y-connected medium-voltage(MV) stage. The study focus on two aspects: 1. The MV stage current stress brought by ASC is analyzed and a negative sequence current compensation method is proposed to reduce the MV stage current stress; 2. The ASC impedance adjustment range that MV stage can provide is analyzed and a virtual impedance method is proposed to achieve this adjustment. The effectiveness of the proposed ASC-PET as well as its control strategy is verified by both simulation and experiment results.
- 23 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (6) , 5294-5311
Control Strategy for Arc-Suppression-Coil-Grounded Star-Connected Power Electronic Transformers
The grounding of low frequency distribution transformer is a critical concern which ensures the proper operation and protection of the distribution system. The power electronic transformer (PET), as a future alternative of low frequency distribution transformer, also needs to consider the grounding. This paper is studying the operation of PET with arc suppression coil(ASC) grounding in the Y-connected medium-voltage(MV) stage. The study focus on two aspects: 1. The MV stage current stress brought by ASC is analyzed and a negative sequence current compensation method is proposed to reduce the MV stage current stress; 2. The ASC impedance adjustment range that MV stage can provide is analyzed and a virtual impedance method is proposed to achieve this adjustment. The effectiveness of the proposed ASC-PET as well as its control strategy is verified by both simulation and experiment results.