NQNurul Qomariyah

Nurul Qomariyah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nurul Qomariyah has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimizing bladder volume to minimize OAR dose in cervical cancer HDR intracavitary brachytherapy: an experimental and analytical dosimetric investigation

    by Tami Oktavia Ariani, Rahadi Wirawan, Marzuki Marzuki, Rinarto Subroto, I Wayan Ari Makmur, Nurul Qomariyah

    This study aims to determine the optimal bladder volume that can balance the dose distribution to the organs-at-risk (OARs), specifically the bladder and rectum, and to analyze the relationship between variations in bladder volume and the dose received by these two organs during high-dose-rate (HDR) brachytherapy. Six bladder volume variations, namely empty, 100 cc, 150 cc, 200 cc, 250 cc, and 300 cc, were used to analyze the correlation between bladder volume and the radiation dose received by the bladder and rectum. An experimental approach was employed by observing the dose point distribution and the D2cc dose to both organs based on calculations from the Treatment Planning System (TPS), which were then compared with analytical calculations using a quadratic polynomial regression model via the Ordinary Least Squares (OLS) method. In general, the bladder point dose and D2cc dose increased with increasing bladder volume; however, the rectal dose demonstrated very high stability (90-100 cGy). Based on the variations in bladder volume, the optimal volume was 100 cc, as it protects the bladder by minimizing dose distribution and stabilizes the dose to the rectum. The statistical analysis results showed that the quadratic regression model had a high goodness-of-fit to the experimental data, with a coefficient of determination (R²) value of 0.92.

  • Open Access

    Design and Development of a 3D-Printed Tissue Equivalent Phantom for Cobalt-60 HDR Brachytherapy

    by Nurul Qomariyah, Abdul Waris, Rahadi Wirawan, Heru Prasetio, Freddy Haryanto

    The use of 3D phantoms represents patient anatomy, enabling more effective treatment planning optimization. This study aims to develop a tissue-equivalent 3D-printed phantom as a dosimetry application for the HDR-BT Cobalt-60 source. Polylactic Acid (PLA) with a single infill density of 85% was used to achieve tissue-equivalent characteristics. The phantom features a 200 mm diameter spherical structure composed of three distinct components, including an applicator channel and cavities in each layer to accommodate the HDR-BT source dose measurement detector. The characteristics of the 3D-PLA phantom were analyzed and compared with soft tissue, muscle, and water based on ICRU-44 reports, as well as with the RW3 phantom (PTW, Germany) as a standard phantom. The resulting 3D-PLA phantom density of 1.05 g/cm3 was in good agreement with muscle, RW3 phantom, soft tissue, and water, respectively. The linear attenuation coefficient of the 3D-PLA phantom at energies >0.1 MeV and its effective atomic number (Zeff) ≈ 8.26 closely resemble soft tissue properties. The HU value of the 3D-PLA phantom is −116.6 ± 7.5 HU, also within the soft tissue HU values range. These findings confirm that the developed 3D-PLA phantom exhibits the necessary characteristics for dosimetry applications.

  • Monte Carlo investigation of beam characteristics for HDR-BT Bebig Co0.A86

    by Nurul Qomariyah, Freddy Haryanto, Abdur Waris, Rahadi Wirawan

    In recent years, the use of radioactive Co-60 in high-dose level brachytherapy (HDR-BT) has grown rapidly. This study aims to model the HDR-BT source, precisely In recent years, the use of radioactive Co-60 in high-dose level brachytherapy (HDR-BT) has grown rapidly. This study aims to model the HDR-BT source, precisely

  • Open Access

    Radiation shielding potential analyze of iron sand-pumice composite based on GEANT4 simulations

    by Rahadi Wirawan, Nurul Qomariyah, Teguh Ardianto, Dian Wijaya Kurniawidi

    In this study, we investigated the effect of the iron sand content in a composite block of radiation shielding on the linear attenuation coefficient and radiation protection effectiveness parameters. The composite block is made of pumice, iron sand, and cement. GEANT4 simulation approaches were carried out for transmitting gamma photons of 133Ba (0.356 MeV), 137Cs (0.662 MeV), and 60Co (1.173 MeV; 1.333 MeV) sources through the composite block (10cm × 10cm × 2cm). The composite block consists of five different mass fractions of iron sand-pumice (75%) with a 25% mass fraction of Portland concrete. Attenuation of gamma full-peak energies was evaluated based on Gaussian fitting in the energy spectrum distribution detected by NaI(Tl) scintillation detector. There is a decrease in the full-peak height of the gamma energy due to the addition of iron sand fraction mass. The addition of iron sand composition increases the linear attenuation coefficient value and radiation protection efficiency (RPE). For a composite thickness of 2 cm and small photon energies such as 133Ba, the RPE of composite blocks can reach 40%. Meanwhile, for the 60Co energies, RPE can reach 25%.

  • Open Access

    Koreksi: Karakteristik Gaharu Grynops Vertegii (Gilg.) Domke Berdasarkan Analisis Sebaran Gray Scale Level

    by Nurul Qomariyah, Rahadi Wirawan, Ni Kadek Nova Anggarani, Laili Mardiana, Kasnasi Al Hadi

    Pernyataan koreksi untuk artikel : https://doi.org/10.29303/emj.v1i1.27

  • Open Access

    Distributions dose analysis for 6 MV photon beams using Monte Carlo-GEANT4 simulation

    by Nurul Qomariyah, Rahadi Wirawan, Laili Mardiana, Kasnawi Al Hadi

    Monte Carlo is a method that widely used for calculation of particle transport in radiotherapy dose distribution. This study was devoted to develop a linear accelerator head geometry model (LINAC) using GEANT4 simulation for 6 MeV photon beam. The geometric model of the accelerator head consists of electron sources, target, primary collimator, flattening filter, jaws, and MLC (multi-leaf collimator). The homogeneous water phantom size of 40 × 40 × 40 cm3 was used in the simulation, 100 cm SSD (source-skin distance), and field size are 5 cm × 5 cm, 10 cm × 10 cm, 20 cm × 20 cm, and 30 cm × 30 cm. The simulation results show the peak curve energy positions are in the range 0.3 MeV – 0.4 MeV and the maximum absorbed energy is about 5.9 MeV. According to the landau curve fitting the mean energy is about 0.385 MeV. The results of GEANT4 simulation show the energy spectrum has the same pattern as an energy spectrum from several experiments of LINAC head geometry. The simulation results also show the dose distribution based on beam profile and depth profile of water phantom with different fields.


  • Open Access

    Karakteristik Gaharu Grynops Vertegii (Gilg.) Domke Berdasarkan Analisis Sebaran Gray Scale Level

    by Nurul Qomariyah, Rahadi Wirawan, Ni Kadek Nova Anggarani, Laili Mardiana, Kasnawi Alhadi

    Gaharu Gyrinops Vertegii (Gilg.) Domke merupakan jenis gaharu yang banyak di ekploitasi di daerah NTB. Nilai ekonomis Gaharu berbanding lurus terhadap kualitasnya, warna merupakan salah satu parameter fisis untuk menentukan kualitas gaharu. Tujuan dari penelitian ini adalah untuk mengklasifikasikan Gaharu Gyrinops Vertegii (Gilg.) berdasarkan sebaran nilai derajat keabuan menggunakan pengolahan citra gaharu. Metode yang digunakan adalah pengolahan citra gaharu berdasarkan gray scale level, Gaharu dibagi menjadi empat kelas berdasarkan warna dominan, dalam penelitian ini dibagi menjadi kelas A, B, C, dan D. Dari citra gaharu dalam bentuk RGB dikonversi dalam bentuk gray scale kemudian diolah dalam bentuk histogram citra untuk mengetahui sebaran derajat keabuan dan intensitasnya. Dari hasil pengolahan gambar dapat dilihat bahwa terjadi pergeseran posisi puncak, perbedaan nilai skala keabuan, dan lebar kurva. Nilai skala keabuan pada masing-masing kelas A, B, C, dan D berada pada nilai derajat keabuan dan intensitas berturut turut 26, 35, 62 dan 121 dengan posisi puncaknya berturut-turut 43.300, 42400, 30350, 31750. Nilai skala keabuan yang kecil menunjukkan kayu gaharu memiliki warna hitam dan sebaliknya, sedangkan posisi puncak menunjukkan nilai gray scale dominan pada masing-masing kelas. Artikel ini sudah dikoreksi berdasarkan pernyataan koreksi di link : https://doi.org/10.29303/emj.v1i1.59


  • Open Access

    PEMETAAN BATUAN MENGANDUNG BIJIH BESI MENGGUNAKAN METODE IT (Intercept Time) DAN MASW (Multichannel Analisis of Surface Wave)

    by Helfifizoh Rotin Komariah, Nurul Qomariyah, Teguh Ardianto

    PEMETAAN BATUAN MENGANDUNG BIJIH BESI MENGGUNAKAN METODE IT (Intercept Time) DAN MASW (Multichannel Analisis of Surface Wave)

  • Open Access

    Peningkatan Kompetensi Guru Dalam Pembelajaran Fisika Berbasis Metode Eksperimen

    by Nurul Qomariyah, Rahadi Wirawan, Lily M Angraini, Ni Kadek Nova Anggarani

    Pembelajaran fisika pada hakikatnya merupakan pembelajaran yang harus berpusat pada siswa, dengan konsep pembelajaran konstruktivisme. Ketepatan metode pengajaran serta keterampilan mengajar guru merupakan faktor penentu dalam meningkatkan motivasi dan kognitif siswa. Oleh karena itu, guru hendaknya memiliki keterampilan tersebut. Metode eksperimen merupakan salah satu metode yang bisa mengimplementasikan konsep konstrutivisme tersebut. Akan tetapi, kendala yang umum dihadapi oleh guru dalam penerapan metode tersebut adalah kurangnya ketersediaan alat-alat praktikum penunjang pembelajaran. Berdasarkan permasalahan tersebut, maka kegiatan pengabdian ini dilaksanakan dengan tujuan pemperkuat konsep metode pembelajaran eksperimen dengan mengembangkan media pembelajaran sebagai solusi ketidaktersediaannya alat praktikum dan sekaligus untuk meningkatkan keterampilan mengajar guru fisika SMA se-kabupaten Lombok Utara. Kegiatan ini dilaksanakan di SMA Negeri 1 Tanjung Kabupaten Lombok Utara, dengan peserta guru-guru fisika yang tergabung dalam MGMP mata pelajaran fisika SMA kabupaten Lombok Utaran. Metode yang digunakan dalam kegiatan ini adalah (1) metode FGD dan Direct Instruction, (2) Metode Demonstrasi dan (3) Metode Problem Based Learning (PBL). Adapun perancangan alat peraga pada kegiatan ini berbasis mikrokontroler menggunakan Arduino Uno. Hasil kegiatan ini (1) tersusunnya perencanaan pembelajaran fisika menggunakan metode eksperimen, (2) Terinstalasinya program Arduino Uno di laptop masing-masing peserta, (3) terbangunnya sebuah prototype sistem pengukuran jarak menggunakan sensor ultrasonic BMP05 dari kerja masing-masing kelompok, (4) meningkatnya keterampilan guru mengajar fisika dengan metode eksperimen.