Distributions dose analysis for 6 MV photon beams using Monte Carlo-GEANT4 simulation
Open Access
- 7 November 2019
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2169 (1) , 030006
Abstract
Monte Carlo is a method that widely used for calculation of particle transport in radiotherapy dose distribution. This study was devoted to develop a linear accelerator head geometry model (LINAC) using GEANT4 simulation for 6 MeV photon beam. The geometric model of the accelerator head consists of electron sources, target, primary collimator, flattening filter, jaws, and MLC (multi-leaf collimator). The homogeneous water phantom size of 40 × 40 × 40 cm3 was used in the simulation, 100 cm SSD (source-skin distance), and field size are 5 cm × 5 cm, 10 cm × 10 cm, 20 cm × 20 cm, and 30 cm × 30 cm. The simulation results show the peak curve energy positions are in the range 0.3 MeV – 0.4 MeV and the maximum absorbed energy is about 5.9 MeV. According to the landau curve fitting the mean energy is about 0.385 MeV. The results of GEANT4 simulation show the energy spectrum has the same pattern as an energy spectrum from several experiments of LINAC head geometry. The simulation results also show the dose distribution based on beam profile and depth profile of water phantom with different fields.Keywords
This publication has 9 references indexed in Scilit:
- Monte Carlo simulation of Novalis Classic 6 MV accelerator using phase space generation in GATE/Geant4 codeProgress in Nuclear Energy, 2019
- Assessment of Monte Carlo Geant4 capabilities in prediction of photon beam dose distribution in a heterogeneous mediumPhysics in Medicine, 2018
- Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo StudyJournal of Radiation Protection and Research, 2018
- VARIAN CLINAC 6 MeV Photon Spectra Unfolding using a Monte Carlo Meshed ModelEPJ Web of Conferences, 2017
- A Monte Carlo Study of the Photon Spectrum due to the Different Materials Used in the Construction of Flattening Filters of LINACComputational and Mathematical Methods in Medicine, 2017
- Validation of Monte Carlo Geant4 code for a 6 MV Varian linacJournal of King Saud University – Science, 2017
- Monte Carlo simulation approaches to dose distributions for 6MV photon beams in clinical linear acceleratorBiocybernetics and Biomedical Engineering, 2014
- Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4Physics in Medicine & Biology, 2011
- Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer codeReports of Practical Oncology and Radiotherapy, 2010